Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 10 de 10
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
1.
Phys Rev Lett ; 130(10): 101001, 2023 Mar 10.
Artigo em Inglês | MEDLINE | ID: mdl-36962014

RESUMO

Dark matter elastic scattering off nuclei can result in the excitation and ionization of the recoiling atom through the so-called Migdal effect. The energy deposition from the ionization electron adds to the energy deposited by the recoiling nuclear system and allows for the detection of interactions of sub-GeV/c^{2} mass dark matter. We present new constraints for sub-GeV/c^{2} dark matter using the dual-phase liquid argon time projection chamber of the DarkSide-50 experiment with an exposure of (12 306±184) kg d. The analysis is based on the ionization signal alone and significantly enhances the sensitivity of DarkSide-50, enabling sensitivity to dark matter with masses down to 40 MeV/c^{2}. Furthermore, it sets the most stringent upper limit on the spin independent dark matter nucleon cross section for masses below 3.6 GeV/c^{2}.

2.
Nature ; 602(7895): 63-67, 2022 02.
Artigo em Inglês | MEDLINE | ID: mdl-35110756

RESUMO

Electrically charged particles can be created by the decay of strong enough electric fields, a phenomenon known as the Schwinger mechanism1. By electromagnetic duality, a sufficiently strong magnetic field would similarly produce magnetic monopoles, if they exist2. Magnetic monopoles are hypothetical fundamental particles that are predicted by several theories beyond the standard model3-7 but have never been experimentally detected. Searching for the existence of magnetic monopoles via the Schwinger mechanism has not yet been attempted, but it is advantageous, owing to the possibility of calculating its rate through semi-classical techniques without perturbation theory, as well as that the production of the magnetic monopoles should be enhanced by their finite size8,9 and strong coupling to photons2,10. Here we present a search for magnetic monopole production by the Schwinger mechanism in Pb-Pb heavy ion collisions at the Large Hadron Collider, producing the strongest known magnetic fields in the current Universe11. It was conducted by the MoEDAL experiment, whose trapping detectors were exposed to 0.235 per nanobarn, or approximately 1.8 × 109, of Pb-Pb collisions with 5.02-teraelectronvolt center-of-mass energy per collision in November 2018. A superconducting quantum interference device (SQUID) magnetometer scanned the trapping detectors of MoEDAL for the presence of magnetic charge, which would induce a persistent current in the SQUID. Magnetic monopoles with integer Dirac charges of 1, 2 and 3 and masses up to 75 gigaelectronvolts per speed of light squared were excluded by the analysis at the 95% confidence level. This provides a lower mass limit for finite-size magnetic monopoles from a collider search and greatly extends previous mass bounds.

3.
Phys Rev Lett ; 126(7): 071801, 2021 Feb 19.
Artigo em Inglês | MEDLINE | ID: mdl-33666471

RESUMO

The MoEDAL trapping detector consists of approximately 800 kg of aluminum volumes. It was exposed during run 2 of the LHC program to 6.46 fb^{-1} of 13 TeV proton-proton collisions at the LHCb interaction point. Evidence for dyons (particles with electric and magnetic charge) captured in the trapping detector was sought by passing the aluminum volumes comprising the detector through a superconducting quantum interference device (SQUID) magnetometer. The presence of a trapped dyon would be signaled by a persistent current induced in the SQUID magnetometer. On the basis of a Drell-Yan production model, we exclude dyons with a magnetic charge ranging up to five Dirac charges (5g_{D}) and an electric charge up to 200 times the fundamental electric charge for mass limits in the range 870-3120 GeV and also monopoles with magnetic charge up to and including 5g_{D} with mass limits in the range 870-2040 GeV.

4.
Phys Rev Lett ; 123(2): 021802, 2019 Jul 12.
Artigo em Inglês | MEDLINE | ID: mdl-31386510

RESUMO

MoEDAL is designed to identify new physics in the form of stable or pseudostable highly ionizing particles produced in high-energy Large Hadron Collider (LHC) collisions. Here we update our previous search for magnetic monopoles in Run 2 using the full trapping detector with almost four times more material and almost twice more integrated luminosity. For the first time at the LHC, the data were interpreted in terms of photon-fusion monopole direct production in addition to the Drell-Yan-like mechanism. The MoEDAL trapping detector, consisting of 794 kg of aluminum samples installed in the forward and lateral regions, was exposed to 4.0 fb^{-1} of 13 TeV proton-proton collisions at the LHCb interaction point and analyzed by searching for induced persistent currents after passage through a superconducting magnetometer. Magnetic charges equal to or above the Dirac charge are excluded in all samples. Monopole spins 0, ½, and 1 are considered and both velocity-independent and-dependent couplings are assumed. This search provides the best current laboratory constraints for monopoles with magnetic charges ranging from two to five times the Dirac charge.

5.
Phys Rev Lett ; 118(6): 061801, 2017 Feb 10.
Artigo em Inglês | MEDLINE | ID: mdl-28234515

RESUMO

MoEDAL is designed to identify new physics in the form of long-lived highly ionizing particles produced in high-energy LHC collisions. Its arrays of plastic nuclear-track detectors and aluminium trapping volumes provide two independent passive detection techniques. We present here the results of a first search for magnetic monopole production in 13 TeV proton-proton collisions using the trapping technique, extending a previous publication with 8 TeV data during LHC Run 1. A total of 222 kg of MoEDAL trapping detector samples was exposed in the forward region and analyzed by searching for induced persistent currents after passage through a superconducting magnetometer. Magnetic charges exceeding half the Dirac charge are excluded in all samples and limits are placed for the first time on the production of magnetic monopoles in 13 TeV pp collisions. The search probes mass ranges previously inaccessible to collider experiments for up to five times the Dirac charge.

6.
Rev Sci Instrum ; 84(5): 053706, 2013 May.
Artigo em Inglês | MEDLINE | ID: mdl-23742557

RESUMO

The image quality and resolution of the Atomic Force Microscope (AFM) operating in tapping mode is dependent on the quality (Q) factor of the sensing micro-cantilever. Increasing the cantilever Q factor improves image resolution and reduces the risk of sample and cantilever damage. Active piezoelectric shunt control is introduced in this work as a new technique for modifying the Q factor of a piezoelectric self-actuating AFM micro-cantilever. An active impedance is placed in series with the tip oscillation voltage source to modify the mechanical dynamics of the cantilever. The benefit of using this control technique is that it removes the optical displacement sensor from the Q control feedback loop to reduce measurement noise in the loop and allows for a reduction in instrument size.

7.
Rev Sci Instrum ; 83(8): 083708, 2012 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-22938304

RESUMO

Active Q control may be used to modify the effective quality (Q) factor of an atomic force microscope (AFM) micro-cantilever when operating in tapping mode. The control system uses velocity feedback to obtain an effective cantilever Q factor to achieve optimal scan speed and image resolution for the imaging environment and sample type. Time delay of the cantilever displacement signal is the most common method of cantilever velocity estimation. Spill-over effects from unmodeled dynamics may degrade the closed loop system performance, possibly resulting in system instability, when time delay velocity estimation is used. A resonant controller is proposed in this work as an alternate method of velocity estimation. This new controller has guaranteed closed loop stability, is easy to tune, and may be fitted into existing commercial AFMs with minimal modification. Images of a calibration grating are obtained using this controller to demonstrate its effectiveness.

8.
Anaesthesia ; 41(6): 637-40, 1986 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-3728936

RESUMO

Fifty patients undergoing microsurgery of the ear were anaesthetised using thiopentone, nitrous oxide, oxygen and either halothane or isoflurane, via a low flow circle system with carbon dioxide absorption. Systolic blood pressure was reduced to approximately 70 mmHg by the additional use of increments of labetalol; the patients breathed spontaneously. The degree of haemostasis was assessed by the surgeon who was unaware which volatile agent was being used to supplement anaesthesia. Isoflurane, although it is a potent vasodilator produced operating conditions which were indistinguishable from halothane. Isoflurane is thus a safe and reliable alternative to halothane as a volatile agent used to supplement anaesthesia when using induced hypotension for middle ear surgery.


Assuntos
Anestesia por Inalação , Orelha Média/cirurgia , Halotano , Hipotensão Controlada , Isoflurano , Éteres Metílicos , Adolescente , Adulto , Idoso , Criança , Feminino , Humanos , Labetalol/administração & dosagem , Masculino , Microcirurgia , Pessoa de Meia-Idade
9.
Anaesthesia ; 37(10): 1028-32, 1982 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-7137550

RESUMO

One hundred patients undergoing microsurgery of the ear were anaesthetised using thiopentone, nitrous oxide, oxygen and either halothane or enflurane with spontaneous respiration. Blood pressure was reduced to approximately 70 mmHg by the use of hypotensive agents. The efficacy of halothane and enflurane in producing good operating conditions was compared during this technique. Haemostasis was assessed by the surgeon who was unaware which volatile agent was being used. Both agents were found to be satisfactory and enflurane was shown to be a safe and reliable agent with this technique should an alternative to halothane be required. No impairment of renal function was seen with either agent in combination with hypotension.


Assuntos
Anestesia por Inalação , Orelha Média/cirurgia , Enflurano , Halotano , Hipotensão Controlada/métodos , Adolescente , Adulto , Idoso , Criança , Feminino , Hemostasia Cirúrgica/métodos , Humanos , Masculino , Microcirurgia , Pessoa de Meia-Idade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA