Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
1.
Diabet Med ; 34(8): 1061-1066, 2017 08.
Artigo em Inglês | MEDLINE | ID: mdl-28430372

RESUMO

AIMS: To investigate retinal nerve fibre layer (RNFL) thickness in people with metabolic syndrome (MetS) and healthy controls. METHODS: A cross-sectional study was performed from March 2014 to January 2016. All participants underwent anthropometric and serological biochemical measurements, ophthalmological examination, and spectral-domain optical coherence tomography (SD-OCT). Individuals with elevated intraocular pressure, glaucoma, diabetic retinopathy and other ocular disorders were excluded. T-test, Chi square and general linear models were used to analyse the data. RESULTS: In total, 278 eyes from 139 participants were investigated [median (interquartile range) age: 37 (32-43) years]. RNFL thickness was lower in the nasal superior (107.8 ± 19.5µm) and temporal superior (135.7 ± 18.9µm) sectors in MetS group compared with the control group (114.6 ± 22.4 µm, P = 0.013 and 140.7 ± 18.2 µm, P = 0.027, respectively). After multiple adjustments for age, gender and the side of the examined [right (OD)/left (OS)] eye, MetS was independently associated with a lower RFNL thickness in the nasal superior (ß = 0.20, P = 0.009) and temporal superior (ß = 0.14, P = 0.048) sectors. RNFL thickness was significantly reduced in participants with higher numbers of metabolic abnormalities, independent of age, gender and the side of the examined eye (P = 0.043). CONCLUSION: Our findings demonstrate that MetS is independently associated with reduced RNFL thickness, suggesting that neurodegeneration is implicated in pathogenesis of MetS.


Assuntos
Síndrome Metabólica/fisiopatologia , Fibras Nervosas Amielínicas/patologia , Doenças Neurodegenerativas/etiologia , Nervo Óptico/diagnóstico por imagem , Retina/diagnóstico por imagem , Adulto , Índice de Massa Corporal , Distribuição de Qui-Quadrado , Estudos de Coortes , Estudos Transversais , Feminino , Hospitais de Ensino , Humanos , Irã (Geográfico) , Modelos Lineares , Masculino , Síndrome Metabólica/complicações , Doenças Neurodegenerativas/diagnóstico por imagem , Doenças Neurodegenerativas/patologia , Obesidade Abdominal/complicações , Obesidade Mórbida/complicações , Nervo Óptico/patologia , Tamanho do Órgão , Retina/patologia , Índice de Gravidade de Doença , Tomografia de Coerência Óptica , Circunferência da Cintura
2.
Eye (Lond) ; 29(11): 1469-76, 2015 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-26228292

RESUMO

PURPOSE: To evaluate intraocular pressure (IOP) change after cataract surgery in non-glaucomatous eyes with narrow and open angles (OAs) and its relation to novel lens parameters measured by anterior segment optical coherence tomography (AS-OCT). SETTING: University affiliated hospital, Farabi Eye Hospital, Tehran, Iran. DESIGN: Prospective interventional case series. METHODS: In this prospective study, 85 non-glaucomatous eyes underwent phacoemulsification and lens implantation. Thirty-nine eyes had OAs and 46 eyes had narrow angles (NAs). IOP and biometric parameters were measured by AS-OCT preoperatively and 3 months after surgery. Change in IOP and its relation to biometric parameters, including lens vault (LV), anterior vault (AV), defined as the sum of the LV and the ACD, and relative LV (rLV), defined as the ratio of the LV to the AV, were evaluated. The main outcome measure was degree of IOP change after phacoemulsification. RESULTS: Of the 85 patients included in the analysis, 35 were male and 50 were female with an overall mean age of 62.2 ± 8.9 years. The average IOP reduction was -4.95 ± 2.26 mm Hg, from a preoperative mean of 17.12 ± 2.47 mm Hg, at 3 months after cataract surgery. The amount of IOP reduction was significantly greater in the NA compared with the OA group. In multivariate linear regression analysis, preoperative IOP and AV were significantly associated with IOP decrease (all ≤ 0.03). CONCLUSION: Cataract surgery results in IOP reduction in both OA and NA eyes. The amount of IOP reduction is related to AV.


Assuntos
Pressão Intraocular/fisiologia , Implante de Lente Intraocular , Facoemulsificação , Pseudofacia/fisiopatologia , Adulto , Idoso , Idoso de 80 Anos ou mais , Câmara Anterior/anatomia & histologia , Biometria , Feminino , Gonioscopia , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Tomografia de Coerência Óptica , Tonometria Ocular , Malha Trabecular/anatomia & histologia , Acuidade Visual/fisiologia
3.
Eye (Lond) ; 28(3): 337-43, 2014 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-24406416

RESUMO

PURPOSE: The purpose of this study is to quantify anterior chamber (AC) parameters and to determine the proportion of eyes with exaggerated lens vault (LV) in different subtypes of angle closure disease using anterior segment optical coherence tomography (AS-OCT). PATIENTS AND METHODS: In this prospective study, 115 eyes of 115 Iranian patients with angle closure disease were included and categorized into three groups: (1) fellow eyes of acute angle closure (AAC; 40 eyes); (2) primary angle closure glaucoma (PACG; 39 eyes); and (3) primary angle closure suspect (PACS; 36 eyes). Complete ophthalmic examination including gonioscopy, A-scan biometry, and AS-OCT were performed. Angle parameters, LV, and iris thickness (IT) were measured using AS-OCT. An exaggerated LV was defined as LV more than one-third the distance between the corneal endothelium and a line drawn to connect the nasal and temporal scleral spurs. RESULTS: Fellow eyes of AAC had the shallower AC (P=0.01), greater iris curvature (I-curve; P=0.01), and higher LV (P=0.02) as compared with PACS and PACG eyes. There was no statistically significant difference in the mean IT at 750 µm from scleral spur among the three groups (P=0.45). Exaggerated LV was found in 67.5, 35.9, and 40% of fellow eyes of AAC, PACG, and PACS, respectively, (P=0.008) with an odds ratio of 1.92 (P=0.005) for fellow vs PACG and 1.68 (P=0.01) for fellow vs PACS. CONCLUSIONS: Exaggerated LV is highly prevalent in fellow eyes of AAC. These eyes have shallower AC depth, greater I-curve, and higher LV when compared with PACG and PACS.


Assuntos
Câmara Anterior/fisiopatologia , Glaucoma de Ângulo Fechado/fisiopatologia , Doenças da Íris/fisiopatologia , Doenças do Cristalino/fisiopatologia , Biometria , Estudos Transversais , Feminino , Glaucoma de Ângulo Fechado/classificação , Gonioscopia , Humanos , Pressão Intraocular/fisiologia , Irã (Geográfico) , Doenças da Íris/diagnóstico , Doenças do Cristalino/diagnóstico , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Tomografia de Coerência Óptica , Tonometria Ocular
4.
Eye (Lond) ; 23(12): 2182-6, 2009 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-19229266

RESUMO

PURPOSE: To compare the ability of scanning laser polarimetry (GDx VCC) and optical coherence tomography (OCT) to discriminate eyes with juvenile glaucoma from normal eyes and to assess the relationship between their parameters. METHODS: A total of 24 glaucomatous eyes of 24 patients and 24 normal eyes were enrolled. The age range of the patient was 11-40 years with a mean age of 25.1+/-8.2 years. Control groups consisted 24 eyes of 24 individuals without glaucoma with a mean age of 33.2+/-8.2 years. All subjects underwent a full ophthalmic examination, automated perimetry, GDx VCC, and OCT. Correlation coefficients between the parameters of OCT and GDx VCC were calculated. We calculated the area under the receiver operating characteristic curve (AROC) for the main parameters of GDx VCC and OCT. RESULTS: Statistically significant correlations were observed between GDx VCC and OCT parameters. Pearson coefficients ranged from 0.75 for inferior average to 0.86 for nerve fibre indicator (NFI)/average thickness OCT. The greatest AROC parameter in OCT (inferior average: 0.92) had a lower area than that in GDx VCC (NFI: 0.99). There was a significant statistical significance in all visual field, GDx VCC, and OCT variables between two groups (P<0.05). CONCLUSIONS: Many GDx VCC parameters were significantly correlated with those of the OCT in patients with juvenile glaucoma. Inferior average and NFI had the greatest AROC parameter in OCT and GDx VCC, respectively. NFI had high sensitivity and specificity for the diagnosis of JOAG.


Assuntos
Glaucoma/diagnóstico , Polarimetria de Varredura a Laser/métodos , Tomografia de Coerência Óptica , Adolescente , Adulto , Criança , Técnicas de Diagnóstico Oftalmológico , Feminino , Humanos , Masculino , Disco Óptico/patologia , Retina/patologia , Sensibilidade e Especificidade , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA