Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
1.
Methods ; 230: 21-31, 2024 Jul 27.
Artigo em Inglês | MEDLINE | ID: mdl-39074539

RESUMO

Envisaging to improve the evaluation of ophthalmic drug products while minimizing the need for animal testing, our group developed the OphthalMimic device, a 3D-printed device that incorporates an artificial lacrimal flow, a cul-de-sac area, a moving eyelid, and a surface that interacts effectively with ophthalmic formulations, thereby providing a close representation of human ocular conditions. An important application of such a device would be its use as a platform for dissolution/release tests that closely mimic in vivo conditions. However, the surface that artificially simulates the cornea should have a higher resistance (10 min) than the previously described polymeric films (5 min). For this key assay upgrade, we describe the process of obtaining and thoroughly characterizing a hydrogel-based hybrid membrane to be used as a platform base to simulate the cornea artificially. Also, the OphthalMimic device suffered design improvements to fit the new membrane and incorporate the moving eyelid. The results confirmed the successful synthesis of the hydrogel components. The membrane's water content (86.25 ± 0.35 %) closely mirrored the human cornea (72 to 85 %). Furthermore, morphological analysis supported the membrane's comparability to the natural cornea. Finally, the performance of different formulations was analysed, demonstrating that the device could differentiate their drainage profile through the viscosity of PLX 14 (79 ± 5 %), PLX 16 (72 ± 4 %), and PLX 20 (57 ± 14 %), and mucoadhesion of PLXCS0.5 (69 ± 1 %), PLX16CS1.0 (65 ± 3 %), PLX16CS1.25 (67 ± 3 %), and the solution (97 ± 8 %). In conclusion, using the hydrogel-based hybrid membrane in the OphthalMimic device represents a significant advancement in the field of ophthalmic drug evaluation, providing a valuable platform for dissolution/release tests. Such a platform aligns with the ethical mandate to reduce animal testing and promises to accelerate the development of safer and more effective ophthalmic drugs.

2.
Methods ; 228: 1-11, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-38759909

RESUMO

The necessity of animal-free performance tests for novel ophthalmic formulation screening is challenging. For this, we developed and validated a new device to simulate the dynamics and physical-chemical barriers of the eye for in vitro performance tests of topic ophthalmic formulations. The OphthalMimic is a 3D-printed device with an artificial lacrimal flow, a cul-de-sac area, a support base, and a simulated cornea comprised of a polymeric membrane containing poly-vinyl alcohol 10 % (w/v), gelatin 2.5 % (w/v), and different proportions of mucin and poloxamer, i.e., 1:1 (M1), 1:2 (M2), and 2:1 (M3) w/v, respectively. The support base is designed to move between 0° and 50° to replicate the movement of an eyelid. We challenged the model by testing the residence performance of poloxamer®407 16 % and poloxamer®407 16 % + chitosan 1 % (PLX16CS10) gels containing fluconazole. The test was conducted with a simulated tear flow of 1.0 mL.min-1 for 5 min. The OphthalMimic successfully distinguished PLX16 and PLX16C10 formulations based on their fluconazole drainage (M1: 65 ± 14 % and 27 ± 10 %; M2: 58 ± 6 % and 38 ± 9 %; M3: 56 ± 5 % and 38 ± 18 %). In conclusion, the OphthalMimic is a promising tool for comparing the animal-free performance of ophthalmic formulations.


Assuntos
Soluções Oftálmicas , Poloxâmero , Poloxâmero/química , Soluções Oftálmicas/química , Administração Oftálmica , Fluconazol/administração & dosagem , Impressão Tridimensional , Córnea/efeitos dos fármacos , Córnea/metabolismo , Animais , Quitosana/química , Alternativas aos Testes com Animais/métodos , Lágrimas/química , Humanos , Gelatina/química
3.
Pharmaceutics ; 15(9)2023 Sep 15.
Artigo em Inglês | MEDLINE | ID: mdl-37765293

RESUMO

Animal models are still used in the research and development of ophthalmic drug products, mainly due to the difficulty in simulating natural physiological conditions with in vitro models, as there is a lack of dynamic protection mechanisms. Therefore, developing alternative ophthalmic models that evaluate drug penetration in the cornea while applying dynamic protection barriers is a contemporary challenge. This study aimed to develop a dynamic ex vivo model using porcine eyes with a simulated lacrimal flow to evaluate the performance of pharmaceutical drug products. A glass donor cell to support a simulated tear flow was designed, optimized, and custom-made. The system was challenged with different formulations (with fluconazole) including excipients with different viscosities (poloxamer 407) and mucoadhesive properties (chitosan). The results were compared to those obtained from a conventional excised cornea model mounted in Franz-type diffusion cells. The dynamic model could differentiate formulations, while the static model did not, overestimating ex vivo drug penetrated amounts. Hence, the dynamic model with simulated tear flow showed to be a simple and promising new alternative method for the drug penetration of ophthalmic formulations that ultimately can reduce the number of animals used in research.

4.
Gels ; 9(4)2023 Mar 24.
Artigo em Inglês | MEDLINE | ID: mdl-37102881

RESUMO

There is a growing interest in innovative products for eyebrow hair loss treatment with fewer adverse effects. Nevertheless, a fundamental formulation aspect of preventing the fragile skin from the ocular region from being irritated is that the formulations remain restricted to the application region and do not run off. Consequently, the methods and protocols in drug delivery scientific research must be adapted to fulfill such performance analysis demand. Thus, this work aimed to propose a novel protocol to evaluate the in vitro performance of a topical gel formulation with a reduced runoff for minoxidil (MXS) delivery to eyebrows. MXS was formulated with 16% poloxamer 407 (PLX) and 0.4% of hydroxypropyl methylcellulose (HPMC). The sol/gel transition temperature, viscosity at 25 °C, and formulation runoff distance on the skin were evaluated to characterize the formulation. The release profile and skin permeation were evaluated in Franz vertical diffusion cells for 12 h and compared to a control formulation (4% PLX and 0.7% HPMC). Then, the formulation's performance at promoting minoxidil skin penetration with minimum runoff was evaluated in a vertical custom-made permeation template (divided into three areas: superior, middle, and inferior). The MXS release profile from the test formulation was comparable to that from the MXS solution and the control formulation. There was also no difference in the MXS amount that penetrated the skin in the permeation experiments in Franz diffusion cells using the different formulations (p > 0.05). However, the test formulation demonstrated a localized MXS delivery at the application site in the vertical permeation experiment. In conclusion, the proposed protocol could differentiate the test formulation from the control, attesting to its better performance in efficiently delivering MXS to the site of interest (middle third of application). The vertical protocol can be easily employed to evaluate other gels with a drip-free appeal.

5.
J Sep Sci ; 38(17): 3038-46, 2015 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-26140379

RESUMO

The Baccharis genus has more than 400 species of aromatic plants. However, only approximately 50 species have been studied in oil composition to date. From these studies, very few take into consideration differences between male and female plants, which is a significant and distinctive factor in Baccharis in the Asteraceae family. Baccharis articulata is a common shrub that grows wild in south Brazil, northern and central Argentina, Bolivia, Paraguay and Uruguay. It is considered to be a medicinal plant and is employed in traditional medicine. We report B. articulata male and female volatile composition obtained by simultaneous distillation-extraction technique and analyzed by gas chromatography with mass spectrometry. Also, an assessment of aromatic differences between volatile extracts was evaluated by gas chromatography with olfactometry. The results show a very similar chemical composition between male and female extracts, with a high proportion of terpene compounds of which ß-pinene, limonene and germacrene D are the main components. Despite the chemical similarity, great differences in aromatic profile were found: male plant samples exhibited the strongest odorants in number and intensity of aromatic attributes. These differences explain field observations which indicate differences between male and female flower aroma, and might be of ecological significance in the attraction of pollinating insects.


Assuntos
Baccharis/química , Cromatografia Gasosa-Espectrometria de Massas/métodos , Olfatometria/métodos , Extratos Vegetais/análise , Baccharis/fisiologia , Monoterpenos Bicíclicos , Compostos Bicíclicos com Pontes/análise , Cromatografia em Camada Fina , Cicloexenos/análise , Destilação , Limoneno , Monoterpenos/análise , Odorantes/análise , Óleos Voláteis/análise , Plantas Medicinais/química , Plantas Medicinais/fisiologia , Sesquiterpenos de Germacrano/análise , Temperatura , Terpenos/análise , Compostos Orgânicos Voláteis/análise
6.
Retina ; 35(2): 294-302, 2015 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-25118827

RESUMO

PURPOSE: Progression of diabetic macular edema has been reported as a common cause of poor visual acuity recovery after cataract surgery in patients with diabetes. Despite being responsible for the blood supply to the outer retina, the role of the choroidal layer in the pathogenesis of diabetic retinopathy (DR) is not yet understood. Our objective is to characterize macular and subfoveal choroidal thickness changes after cataract surgery in eyes with DR. METHODS: Thirty-five eyes with clinically significant cataract of patients with DR were divided into three groups based on clinical and optical coherence tomography findings: patients with DR without macular edema, patients with DR and macular thickening detected on optical coherence tomography, and finally patients with clinically significant macular edema. All cases were submitted to ophthalmologic examination and spectral domain optical coherence tomography 1 week before cataract surgery and repeated 1 month after surgery. Patients with preoperative clinically significant macular edema were treated with intravitreal bevacizumab at the time of surgery. RESULTS: All groups showed a significant increase in visual acuity 1 month after surgery (P < 0.001). Mean foveal thickness increased significantly in all groups, including controls (P = 0.013), except in patients who were simultaneously treated with intravitreal bevacizumab (P = 0.933). An increase of maximum macular thickness of at least 11% was found in 25.7% of the DR eyes, but no such increase occurred in the control eyes. No significant change was verified for subfoveal choroidal thickness in any of the studied groups. CONCLUSION: Surgical inflammation associated with cataract surgery caused a significant increase of macular thickness in control and DR eyes that were not treated with intravitreous bevacizumab. Such macular changes were not accompanied by subfoveal choroidal thickness changes in any of the study groups, suggesting that the changes in macular thickness associated with the surgery are not related to changes in choroidal thickness and that there is no relation between inner blood-retinal barrier status and diabetic choroidal angiopathy.


Assuntos
Catarata/fisiopatologia , Corioide/patologia , Retinopatia Diabética/fisiopatologia , Macula Lutea/patologia , Facoemulsificação , Acuidade Visual/fisiologia , Idoso , Barreira Hematorretiniana , Catarata/complicações , Retinopatia Diabética/complicações , Retinopatia Diabética/diagnóstico , Feminino , Angiofluoresceinografia , Humanos , Implante de Lente Intraocular , Masculino , Tamanho do Órgão , Estudos Prospectivos , Tomografia de Coerência Óptica
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA