Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 60
Filtrar
1.
Phys Rev Lett ; 133(7): 071501, 2024 Aug 16.
Artigo em Inglês | MEDLINE | ID: mdl-39213544

RESUMO

On 9 October 2022, the Large High Altitude Air Shower Observatory (LHAASO) reported the observation of the very early TeV afterglow of the brightest-of-all-time gamma-ray burst 221009A, recording the highest photon statistics in the TeV band ever obtained from a gamma-ray burst. We use this unique observation to place stringent constraints on the energy dependence of the speed of light in vacuum, a manifestation of Lorentz invariance violation (LIV) predicted by some quantum gravity (QG) theories. Our results show that the 95% confidence level lower limits on the QG energy scales are E_{QG,1}>10 times the Planck energy E_{Pl} for the linear LIV effect, and E_{QG,2}>6×10^{-8}E_{Pl} for the quadratic LIV effect. Our limits on the quadratic LIV case improve previous best bounds by factors of 5-7.

2.
Phys Rev Lett ; 133(6): 061001, 2024 Aug 09.
Artigo em Inglês | MEDLINE | ID: mdl-39178452

RESUMO

In this Letter we try to search for signals generated by ultraheavy dark matter at the Large High Altitude Air Shower Observatory (LHAASO) data. We look for possible γ rays by dark matter annihilation or decay from 16 dwarf spheroidal galaxies in the field of view of the LHAASO. Dwarf spheroidal galaxies are among the most promising targets for indirect detection of dark matter that have low fluxes of astrophysical γ-ray background while having large amount of dark matter. By analyzing more than 700 days of observational data at LHAASO, no significant dark matter signal from 1 TeV to 1 EeV is detected. Accordingly we derive the most stringent constraints on the ultraheavy dark matter annihilation cross section up to EeV. The constraints on the lifetime of dark matter in decay mode are also derived.

3.
Phys Rev Lett ; 132(13): 131002, 2024 Mar 29.
Artigo em Inglês | MEDLINE | ID: mdl-38613275

RESUMO

We present the measurements of all-particle energy spectrum and mean logarithmic mass of cosmic rays in the energy range of 0.3-30 PeV using data collected from LHAASO-KM2A between September 2021 and December 2022, which is based on a nearly composition-independent energy reconstruction method, achieving unprecedented accuracy. Our analysis reveals the position of the knee at 3.67±0.05±0.15 PeV. Below the knee, the spectral index is found to be -2.7413±0.0004±0.0050, while above the knee, it is -3.128±0.005±0.027, with the sharpness of the transition measured with a statistical error of 2%. The mean logarithmic mass of cosmic rays is almost heavier than helium in the whole measured energy range. It decreases from 1.7 at 0.3 PeV to 1.3 at 3 PeV, representing a 24% decline following a power law with an index of -0.1200±0.0003±0.0341. This is equivalent to an increase in abundance of light components. Above the knee, the mean logarithmic mass exhibits a power law trend towards heavier components, which is reversal to the behavior observed in the all-particle energy spectrum. Additionally, the knee position and the change in power-law index are approximately the same. These findings suggest that the knee observed in the all-particle spectrum corresponds to the knee of the light component, rather than the medium-heavy components.

4.
Phys Rev Lett ; 131(15): 151001, 2023 Oct 13.
Artigo em Inglês | MEDLINE | ID: mdl-37897763

RESUMO

The diffuse Galactic γ-ray emission, mainly produced via interactions between cosmic rays and the interstellar medium and/or radiation field, is a very important probe of the distribution, propagation, and interaction of cosmic rays in the Milky Way. In this Letter, we report the measurements of diffuse γ rays from the Galactic plane between 10 TeV and 1 PeV energies, with the square kilometer array of the Large High Altitude Air Shower Observatory (LHAASO). Diffuse emissions from the inner (15°10 TeV). The energy spectrum in the inner Galaxy regions can be described by a power-law function with an index of -2.99±0.04, which is different from the curved spectrum as expected from hadronic interactions between locally measured cosmic rays and the line-of-sight integrated gas content. Furthermore, the measured flux is higher by a factor of ∼3 than the prediction. A similar spectrum with an index of -2.99±0.07 is found in the outer Galaxy region, and the absolute flux for 10≲E≲60 TeV is again higher than the prediction for hadronic cosmic ray interactions. The latitude distributions of the diffuse emission are consistent with the gas distribution, while the longitude distributions show clear deviation from the gas distribution. The LHAASO measurements imply that either additional emission sources exist or cosmic ray intensities have spatial variations.

5.
Science ; 380(6652): 1390-1396, 2023 Jun 30.
Artigo em Inglês | MEDLINE | ID: mdl-37289911

RESUMO

Some gamma-ray bursts (GRBs) have a tera-electron volt (TeV) afterglow, but the early onset of this has not been observed. We report observations with the Large High Altitude Air Shower Observatory (LHAASO) of the bright GRB 221009A, which serendipitously occurred within the instrument's field of view. More than 64,000 photons >0.2 TeV were detected within the first 3000 seconds. The TeV flux began several minutes after the GRB trigger and then rose to a peak ~10 seconds later. This was followed by a decay phase, which became more rapid ~650 seconds after the peak. We interpret the emission using a model of a relativistic jet with half-opening angle of ~0.8°. This is consistent with the core of a structured jet and could explain the high isotropic energy of this GRB.

6.
Zhonghua Liu Xing Bing Xue Za Zhi ; 44(5): 845-850, 2023 May 10.
Artigo em Chinês | MEDLINE | ID: mdl-37221077

RESUMO

Objective: To establish a dynamic syndromic surveillance system in the border areas of Yunnan Province based on information technology, evaluate its effectiveness and timeliness in the response to common communicable disease epidemics and improve the communicable disease prevention and control in border areas. Methods: Three border counties were selected for full coverage as study areas, and dynamic surveillance for 14 symptoms and 6 syndromes were conducted in medical institutions, the daily collection of information about students' school absence in primary schools and febrile illness in inbound people at border ports were conducted in these counties from January 2016 to February 2018 to establish an early warning system based on mobile phone and computer platform for a field experimental study. Results: With syndromes of rash, influenza-like illness and the numbers of primary school absence, the most common communicable disease events, such as hand foot and mouth disease, influenza and chickenpox, can be identified 1-5 days in advance by using EARS-3C and Kulldorff time-space scanning models with high sensitivity and specificity. The system is easy to use with strong security and feasibility. All the information and the warning alerts are released in the form of interactive charts and visual maps, which can facilitate the timely response. Conclusions: This system is highly effective and easy to operate in the detection of possible outbreaks of common communicable diseases in border areas in real time, so the timely and effective intervention can be conducted to reduce the risk of local and cross-border communicable disease outbreaks. It has practical application value.


Assuntos
Telefone Celular , Influenza Humana , Humanos , Vigilância de Evento Sentinela , Síndrome , China
7.
Zhonghua Zhong Liu Za Zhi ; 45(4): 358-367, 2023 Apr 23.
Artigo em Chinês | MEDLINE | ID: mdl-37078218

RESUMO

Objective: To investigate the response characteristics of patients with locally advanced/metastatic non-squamous non-small cell lung cancer (nsq-NSCLC) treated with tislelizumab in combination with chemotherapy in the first line. Methods: Patients with nsq-NSCLC who achieved complete or partial remission after treatment with tislelizumab in combination with chemotherapy or chemotherapy alone in the RATIONALE 304 study, as assessed by an independent review board, were selected to analyze the response characteristics and safety profile of the responders. Time to response (TTR) was defined as the time from randomization to the achievement of first objective response. Depth of response (DpR) was defined as the maximum percentage of tumor shrinkage compared with the sum of the baseline target lesion length diameters. Results: As of January 23, 2020, 128 patients treated with tislelizumab in combination with chemotherapy achieved objective tumor response (responders), representing 57.4%(128/223) of the intention-to-treat population, with a TTR of 5.1 to 33.3 weeks and a median TTR of 7.9 weeks. Of the responders (128), 50.8%(65) achieved first remission at the first efficacy assessment (week 6), 31.3%(40) at the second efficacy assessment (week 12), and 18.0%(23) at the third and subsequent tumor assessments. The percentages of responders who achieved a depth of tumor response of 30% to <50%, 50% to <70% and 70% to 100% were 45.3%(58/128), 28.1%(36/128) and 26.6%(34/128), respectively, with median progression-free survival (PFS) of 9.0 months (95% CI: 7.7 to 9.9 months), 11.5 months (95% CI: 7.7 months to not reached) and not reached (95% CI: 11.8 months to not estimable), respectively. Tislelizumab plus chemotherapy were generally well tolerated in responders with similar safety profile to the overall safety population. Conclusion: Among responders to tislelizumab in combination with chemotherapy for nsq-NSCLC, 82.0%(105/128) achieves response within the first two tumor assessments (12 weeks) and 18.0%(23/128) achieves response at later (18 to 33 weeks) assessments, and there is a trend toward prolonged PFS in responders with deeper tumor response.


Assuntos
Carcinoma Pulmonar de Células não Pequenas , Neoplasias Pulmonares , Humanos , Anticorpos Monoclonais Humanizados/uso terapêutico , Protocolos de Quimioterapia Combinada Antineoplásica/efeitos adversos , Carcinoma Pulmonar de Células não Pequenas/patologia , Neoplasias Pulmonares/patologia , Resultado do Tratamento
8.
Zhonghua Yi Xue Za Zhi ; 103(3): 199-204, 2023 Jan 17.
Artigo em Chinês | MEDLINE | ID: mdl-36649991

RESUMO

Objective: According to the formula provided by the TG43 report [AAPM TG43 (2004)] proposed by the American Association of Physicists in Medicine (AAPM) in 2004, we calculated the dose distribution around the radioactive iodine-125 particles, and verified the calculation accuracy of the radioactive iodine-125 particles treatment planning system. Methods: AAPM TG43 (2004) report provides two calculation methods when calculating the dose around a single radioactive source. The calculation method that does not consider the geometric structure of the radioactive source is called point source calculation method, and the calculation method that considers the geometric structure of the radioactive source is called line source calculation method. Assuming a single Amersham 6711 radioactive iodine-125 particle with an activity of 100 U, the following point doses were calculated according to the two calculation methods provided by AAPM TG43 (2004) report, at 0°, 90° directions, distances 0.5, 1, 1.5, 2, 2.5, 3, 3.5, 4, 4.5, 5, 5.5 and 6 cm; In the direction of 45°, the doses at 0.71, 1.41, 2.12, 2.83, 3.54, 4.24, 4.95, 5.66, 6.36, 7.07, 7.78 and 8.49 cm. On the clinically used brachytherapy planning system variseeds 8.0, the above two calculation methods are used to calculate the corresponding activity and the dose around the corresponding type of radioactive iodine-125 particles, and the function of capturing points to templates built in the planning system is used to accurately find the above corresponding point position, using a single measurement of the above corresponding point dose; and comparation of the results were performed to see if there is a statistical difference. Results: The AAPM TG43 report uses point source calculation method to calculate the dose of single Amersham 6711 radioactive iodine-125 particles with activity of 100 U at 0° and 90° directions. The points with the same distance and the same dose are 8 082.18, 1 870.08, 756.58, 381.47, 217.11, 131.91, 86.55, 58.32, 39.97, 27.42, 19.74, 14.13 Gy, respectively, at 0.5, 1, 1.5, 2, 2.5, 3, 3.5, 4, 4.5, 5, 5.5 and 6 cm away from them. In the 45° direction, the doses at the distances of 0.71, 1.41, 2.12, 2.83, 3.54, 4.24, 4.95, 5.66, 6.36, 7.07, 7.78 and 8.49 cm are 3 957.37, 865.83, 329.99, 155.69, 84.10, 48.50, 28.49, 17.80, 11.37, 7.38, 4.98 and 3.39 Gy, respectively; For line source calculation method, radioactive particles are at the same distance as above. The doses at each point in the direction of 0° are 3 128.71, 755.44, 330.30, 180.53, 107.74, 68.56, 46.40, 32.22, 22.70, 16.00, 11.51, 8.24 Gy, respectively. The doses at each point in the direction of 90° are 8 306.46, 1 981.01, 802.74, 405.38, 230.60, 140.03, 91.83, 61.84, 42.36, 29.05, 20.91, 14.97 Gy; In the 45° direction, the dose at the corresponding distance as above is 4 020.78, 877.43, 333.49, 156.93, 84.69, 48.81, 28.65, 17.89, 11.42, 7.41, 4.99 and 3.40 Gy, respectively. The maximum dose difference (0.3%) between the two methods is 7.78 cm in the 45° direction, the maximum difference (-0.3%) between the two methods is 8.49 cm in the 45° direction, and the value of other sampling points is less than 0.3%. The closer the Amersham 6711 iodine-125 particles are to the source in the directions of 0°, 45°, and 90°, the faster the dose will drop, and the dose will drop gradually as the distance increases. Conclusion: The brachytherapy planning system variseeds 8.0 and the AAPM TG43 report calculate a maximum dose difference of 0.3%, which can accurately calculate the dose distribution around radioactive iodine-125 seeds, and provide a reliable tool for the clinical implementation of radioactive iodine-125 particles implantation for tumor treatment.


Assuntos
Braquiterapia , Neoplasias da Glândula Tireoide , Humanos , Radioisótopos do Iodo , Dosagem Radioterapêutica , Método de Monte Carlo , Planejamento da Radioterapia Assistida por Computador/métodos , Radiometria/métodos
9.
Phys Rev Lett ; 128(5): 051102, 2022 Feb 04.
Artigo em Inglês | MEDLINE | ID: mdl-35179919

RESUMO

Recently, the LHAASO Collaboration published the detection of 12 ultrahigh-energy γ-ray sources above 100 TeV, with the highest energy photon reaching 1.4 PeV. The first detection of PeV γ rays from astrophysical sources may provide a very sensitive probe of the effect of the Lorentz invariance violation (LIV), which results in decay of high-energy γ rays in the superluminal scenario and hence a sharp cutoff of the energy spectrum. Two highest energy sources are studied in this work. No signature of the existence of the LIV is found in their energy spectra, and the lower limits on the LIV energy scale are derived. Our results show that the first-order LIV energy scale should be higher than about 10^{5} times the Planck scale M_{Pl} and that the second-order LIV scale is >10^{-3}M_{Pl}. Both limits improve by at least one order of magnitude the previous results.

10.
Phys Rev Lett ; 129(26): 261103, 2022 Dec 23.
Artigo em Inglês | MEDLINE | ID: mdl-36608208

RESUMO

The kilometer square array (KM2A) of the large high altitude air shower observatory (LHAASO) aims at surveying the northern γ-ray sky at energies above 10 TeV with unprecedented sensitivity. γ-ray observations have long been one of the most powerful tools for dark matter searches, as, e.g., high-energy γ rays could be produced by the decays of heavy dark matter particles. In this Letter, we present the first dark matter analysis with LHAASO-KM2A, using the first 340 days of data from 1/2-KM2A and 230 days of data from 3/4-KM2A. Several regions of interest are used to search for a signal and account for the residual cosmic-ray background after γ/hadron separation. We find no excess of dark matter signals, and thus place some of the strongest γ-ray constraints on the lifetime of heavy dark matter particles with mass between 10^{5} and 10^{9} GeV. Our results with LHAASO are robust, and have important implications for dark matter interpretations of the diffuse astrophysical high-energy neutrino emission.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA