Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
1.
Sensors (Basel) ; 24(15)2024 Aug 05.
Artigo em Inglês | MEDLINE | ID: mdl-39124120

RESUMO

Weak magnetic detection technology can detect stress concentration areas in ferromagnetic materials. However, the stress non-uniform characteristics of pipeline welds lead to significant differences in stress distribution range and values between inner wall welds and outer wall welds. This discrepancy makes it crucial to further evaluate the impact of stress non-uniformity on magnetic signals. To study the magnetic signal characteristics under the influence of residual stress in weld seams, a magneto-mechanical analytical model was established based on the magnetic charge theory and the distribution characteristics of residual stress in the weld seam. The magneto-mechanical relationship and magnetic signal distribution characteristics at the inner and outer wall welds of the pipeline are calculated. Furthermore, the effects of different excitation intensities on the amplitude growth characteristics of magnetic signals are analyzed and compared. To verify the analysis model, weld detection experiments with different excitation intensities were designed. The results show that both the peak-to-valley values of the normal component and the peak values of the tangential component of the outer wall weld are lower than those of the inner wall weld. Conversely, the peak-to-valley width of the normal component and the peak width of the tangential component are greater than those of the inner wall weld. Additionally, the rate of increase in weak magnetic signal amplitude decreases in a first-order exponential relationship with increasing excitation intensity. The average decay rates of the normal and tangential component amplitude growth rates for the inner wall weld are 34.03% and 27.9%, respectively, while for the outer wall weld, they are 31.75% and 28.01%, respectively. This study contributes to the identification and quantitative assessment of weak magnetic signals in inner and outer wall welds.

2.
Foods ; 12(6)2023 Mar 22.
Artigo em Inglês | MEDLINE | ID: mdl-36981269

RESUMO

This study investigated the effect of edible coating (EC), modified atmosphere packaging (MAP), and edible coating + modified atmosphere packaging (EC + MAP) treatments on the quality of fresh-cut pineapples during storage at 4 °C. The quality differences were analyzed by measuring the quality, physiological indicators, and total microbial counts. After 8 d of storage, the brightness (L*) values of the EC + MAP and control samples were 72.76 and 60.83, respectively. The water loss and respiratory rate of the EC + MAP were significantly inhibited from 0% and 29.33 mg CO2 kg-1 h-1 to 4.13% and 43.84 mg CO2 kg-1 h-1, respectively. Furthermore, the fresh-cut pineapples treated with EC + MAP presented a good appearance, with lower total soluble solids (TSS) and relative conductivity and higher titratable acid (TA), ascorbic acid (AA), total phenol content, and firmness compared to the other treatment groups. At the end of storage, the EC + MAP samples exhibited the lowest polyphenol oxidase (PPO) activity, peroxidase (POD) activity, and malondialdehyde (MDA) content at 28.53 U, 60.37 U, and 1.47 nmol·g-1, respectively. Furthermore, the efficiency of EC + MAP treatment exceeded that of EC or MAP alone, preventing key problems involving the surface browning and microbiological safety of the fresh-cut pineapples. The results showed that EC + MAP treatment was more successful in maintaining the storage quality and extending the shelf life of fresh-cut pineapples.

3.
J Food Sci ; 88(1): 328-340, 2023 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-36510379

RESUMO

This study synthesized titanium dioxide (TiO2 ) nanoparticles (NPs) from mango leaf extract and investigated the features and antibacterial capabilities of three different. The microscopic morphological observation, scanning electron microscopy, and transmission electron microscopy results showed that all three NPs showed agglomeration phenomenon, and the TN-1 sample existed as large agglomerates, whereas the agglomeration phenomenon of TN-3 sample was improved by the modified, without large agglomerates. The biosynthetic TN-2 and TN-3 NPs were spherical and uniform in size, whereas those of the TN-3 sample was the smallest, ranging from 10 to 30 nm. X-ray diffraction and Raman spectroscopy results exhibited that these were highly pure anatase NPs. The result of ultraviolet (UV)-visible-near-infrared spectral analysis showed that the TN-2 and TN-3 samples displayed higher UV absorption properties than the TN-1 samples and were highest in the modified NPs, which was more suitable for preparing chitosan-based nanocomposite material in future experiments and studies. The colony diameters of the TN-1, TN-2, and TN-3 treatment groups were 7.99, 7.80, and 6.86 mm, respectively, after 120 min of UV light induction at a wavelength of 365 nm. Significant differences were evident between the TN-3 and the other two groups (p < 0.05), indicating that the TN-3 sample more effectively inhibited Penicillium steckii than the other TiO2 NPs. PRACTICAL APPLICATION: Nanomaterials coated film preservation is widely used in fruit and vegetable preservation. In this paper, TiO2 nanomaterials will be green synthesized using mango leaf and structurally characterized, whereas antibacterial tests will be conducted against the mango fruit-specific bacterium Penicillium steckii, which will provide a theoretical basis for the storage and preservation of mango.


Assuntos
Nanopartículas Metálicas , Nanopartículas , Antifúngicos/farmacologia , Nanopartículas/química , Titânio/farmacologia , Titânio/química , Antibacterianos/farmacologia , Antibacterianos/química , Difração de Raios X , Nanopartículas Metálicas/química
4.
J Food Sci ; 87(7): 2980-2998, 2022 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-35638346

RESUMO

This experiment aimed to investigate the effects of four drying methods, namely, hot air drying (HAD), microwave drying (MD), vacuum drying (VD), and microwave vacuum drying (MVD), on the quality of lemon slices. The relevant indicators, including total phenolic content, ascorbic acid content, browning, color, reducing sugar content, volatile component measurements, and principal component analysis of 0 and 30 days storage, were compared after exposure to the four drying methods. The shortest time of 64 min was used to treat the lemon slices via MVD at 1 KW. These samples displayed the least damage after drying and the highest rehydration ratio of 4.12. The contents of VC, reducing sugars, and total phenols of MVD samples were significantly higher than those in the HAD, VD, and MD groups, retaining 105.94 mg/100 g, 21.35 g/100 g, and 77.81 mg GAE/g, respectively, while their color difference values were also the smallest, with a browning degree of 3.55, significantly lower than those in the other treatment groups (p < 0.05), and the degree of browning of the samples in the HAD treatment group was the most serious; in terms of volatile flavor substances, the lemon slice samples in the MVD and HAD treatment groups were more diverse and of better quality. The order of product sensory evaluation was: MVD > VD > HAD > MD. The final scores after comprehensive analysis revealed the order of the four drying methods as MVD, HAD, VD, and MD. Therefore, MVD had a better effect on the sensory perception and nutritional properties of the lemon slices, providing a useful alternative to the conventional drying method. PRACTICAL APPLICATION: Lemon slices during drying are affected by various aspects, leading to changes in its color, aroma substances, and nutrient composition. The results of this work will not only provide a technical reference for the future production of high-quality dried lemon slices, but also have important implications for fresh-cut lemons in processing and storage. It also generates important implications for fresh-cut lemons in processing and storage.


Assuntos
Dessecação , Micro-Ondas , Ácido Ascórbico/análise , Dessecação/métodos , Fenóis/análise , Vácuo
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA