RESUMO

Energy consumption is the main performance indicator of reclaimed water plant (RWP) operation. Methods of specific energy consumption analysis, unit energy consumption analysis and redundancy analysis were applied to investigate the composition and spatio-temporal distribution of energy consumption in Qinghe RWP with inverted A2/O, A2/O and A2/O-MBR processes. And the A2/ O-MBR process was mainly analyzed to identify the main nodes and causes for high energy consumption, approaches for energy saving were explored, and the energy consumption before and after upgrading for energy saving was compared. The results showed that aeration was the key factor affecting energy consumption in both conventional and A2/O-MBR processes, accounting for 42.97% and 50.65% of total energy consumption, respectively. A pulsating aeration allowed an increasing membrane flux and remarkably reduced the energy consumption of the A2/O-MBR process while still meeting the effluent standard, e.g., the membrane flux was increased by 20%, and the energy consumptions per kiloton wastewater and kilogram COD(removed) were decreased by 42.39% to 0.53 kW-h-kg-3 and by 54.74% to 1.29 kW x h x kg(-1), respectively. The decrease of backflow ratio in the A2/O-MBR process within a certain range would not deteriorate the effluent quality due to its insignificant correlation with the effluent quality, and therefore may be considered as one of the ways for further energy saving.


Assuntos
Conservação de Recursos Energéticos , Eliminação de Resíduos Líquidos/métodos , Águas Residuárias , Membranas Artificiais , Purificação da Água
2.
Huan Jing Ke Xue ; 30(8): 2332-41, 2009 Aug 15.
Artigo em Chinês | MEDLINE | ID: mdl-19799297

RESUMO

A novel grille form complex membrane module composed of glass fiber covered with organic membrane and the dynamic membrane bioreactor (DMBR) with this complex membrane were studied. The results showed that the flux of the dynamic membrane of glass fiber tube without covering with organic membrane solution was only 4 L/(m2 x h) at a trans-membrane pressure (TMP) of 0.02 MPa. After the modification of covering with the organic membrane solution, the complex dynamic membrane flux could reach to a level of 16 L/(m2 x h) at a TMP of 0.01 MPa in operation, and after a hydraulic and chemical cleaning, the membrane flux was up to 17.1 L/(m2 x h) at a lower TMP of 0.003 MPa. When the glass fiber tube was coated with a membrane solution with a concentration of 1:4 (membrane materials/solution in volume ratio), the flux of the complex membrane worked steadily at 14.29 L/(m2 x h) more than 51 days, and according to calculation by TMP rising, the flux could maintain for almost 275 d. The average removal rates of COD and NH4+ -N were 81.96% and 83.66% respectively by the DMBR, and that were 21.01% and 3.61% only by the complex dynamic membrane. Moreover, the cost of complex membrane was approximately 40-60 yuan/m2, which was lower than the traditional organic membrane.


Assuntos
Reatores Biológicos , Vidro/química , Membranas Artificiais , Eliminação de Resíduos Líquidos/instrumentação , Poluentes Químicos da Água/isolamento & purificação , Biodegradação Ambiental , Desenho de Equipamento , Nitrogênio/isolamento & purificação , Nitrogênio/metabolismo , Compostos Orgânicos/isolamento & purificação , Compostos Orgânicos/metabolismo , Compostos de Amônio Quaternário/isolamento & purificação , Compostos de Amônio Quaternário/metabolismo , Eliminação de Resíduos Líquidos/métodos , Poluentes Químicos da Água/metabolismo
3.
J Environ Sci (China) ; 19(1): 12-7, 2007.
Artigo em Inglês | MEDLINE | ID: mdl-17913147

RESUMO

Removal of inorganic nitrogen (inorganic-N) from toilet wastewater, using a pilot-scale airlift external circulation membrane bioreactor (AEC-MBR) was studied. The results showed that the use of AEC-MBR with limited addition of alkaline reagents and volumetric loading rates of inorganic-N of 0.19-0.40 kg inorganic-N/(m3 x d) helped achieve the desired nitrification and denitrification. Furthermore, the effects of pH and dissolved oxygen (DO) on inorganic-N removal were examined. Under the condition of MLSS at 1.56-2.35 g/L, BOD5/ammonia nitrogen (NH4+ -N) at 1.0, pH at 7.0-7.5, and DO at 1.0-2.0 mg/L, the removal efficiencies of NH4+ -N and inorganic-N were 91.5% and 70.0%, respectively, in the AEC-MBR. The cost of addition of alkaline reagent was approximately 0.5-1.5 RMB yuan/m3, and the energy consumption was approximately 0.72 kWh/m3 at the flux of 8 L/(m2 x h).


Assuntos
Reatores Biológicos , Membranas Artificiais , Nitrogênio/isolamento & purificação , Água/química , Concentração de Íons de Hidrogênio
4.
J Environ Sci (China) ; 19(7): 811-7, 2007.
Artigo em Inglês | MEDLINE | ID: mdl-17966868

RESUMO

Using the surface of poly (sulfone) hollow fiber membrane segments as grafted layer, the hydrophilic acrylamide chain was grafted on by UV-photoinduced grafting polymerization. The gained improvement of surface wettability for the modified membrane was tested by measuring the contact-angle as well as FTIR spectra. Then correlation between the hydrophilic ability of support material and the biofilm adherence ability was demonstrated by comparing the pollutant removal rates from urban wastewater via two identical lab-scale up-flow biological aerated filters, one employed the surface wettability modified poly (sulfone) hollow fiber membrane segment as biofilm carrier and the other employed unmodified membrane segment as biofilm carrier. The experimental results showed that under the conditions of influent flux 5 L/h, hydraulic retention time 9 h and gas to liquid ratio (G/L) 10:1, the removal rates of chemical oxygen demand (COD) and ammonium nitrogen (NH4(+)-N) for the modified packing filter and the unmodified packing filter was averaged at 83.64% and 96.25%, respectively, with the former filter being 5%-20% more than the latter. The effluent concentration of COD, NH4(+)-N and turbidity for the modified packing filter was 25.25 mg/L, 2 mg/L and 8 NTU, respectively. Moreover, the ammonium nitrogen removal performance of the filter packing the modified PSF was compared with the other bioreactor packing of an efficient floating medium. The biomass test indicated that the modified membrane matrixes provided better specific adhesion (3310-5653 mg TSS/L support), which gave a mean of 1000 mg TSS/L more than the unmodified membrane did. In addition, the phenomenon of simultaneous denitrification on the inner surface of the support and nitrification on the outer surface was found in this work.


Assuntos
Nitratos/metabolismo , Nitrogênio/metabolismo , Compostos de Amônio Quaternário/metabolismo , Eliminação de Resíduos Líquidos/instrumentação , Poluentes Químicos da Água/metabolismo , Bactérias/metabolismo , Biofilmes , Polímeros , Sulfonas , Eliminação de Resíduos Líquidos/métodos
5.
Huan Jing Ke Xue ; 28(4): 747-53, 2007 Apr.
Artigo em Chinês | MEDLINE | ID: mdl-17639931

RESUMO

A new type of fiberglass tubular self-forming dynamic membrane bioreactor (DMBR) and its application for treatment of landfill leachate on laboratory scale were studied. The results showed that the system worked with a average membrane flux 3.75 L/m2 x h) maintained by gravity filtration at a trans-membrane pressure (TMP) of 2 900 Pa for near 80 days. After the modification of membrane module, a higher membrane flux was achieved at a TMP of 1 450 Pa and the membrane flux could be maintained steadily at 6 L/(m2 x h) for a long time. At the same time, the formation and filtration performance of dynamic membrane (DM) was tested. The effluent turbidity was blow 1.0 NTU and the average removal of COD, BOD5 and NH4(+) -N in this system exceeded 71%, 96% and 98% respectively. Moreover, COD removal from the supernatant on an average of 19.34% was made only by the dynamic membrane.


Assuntos
Reatores Biológicos , Eliminação de Resíduos Líquidos/instrumentação , Filtração , Membranas Artificiais , Reprodutibilidade dos Testes , Eliminação de Resíduos Líquidos/métodos
6.
J Environ Sci (China) ; 17(5): 842-5, 2005.
Artigo em Inglês | MEDLINE | ID: mdl-16313015

RESUMO

A water quality model for water reuse was made by mathematics induction. The relationship among the reuse rate of treated wastewater (R), pollutant concentration of reused water (Cs), pollutant concentration of influent (C0), removal efficiency of pollutant in wastewater (E), and the standard of reuse water were discussed in this study. According to the experiment result of a toilet wastewater treatment and reuse with membrane bioreactors, R would be set at less than 40%, on which all the concemed parameters could meet with the reuse water standards. To raise R of reuse water in the toilet, an important way was to improve color removal of the wastewater.


Assuntos
Reatores Biológicos , Modelos Teóricos , Eliminação de Resíduos Líquidos/métodos , Poluentes Químicos da Água/análise , Purificação da Água/métodos , Abastecimento de Água/análise , Abastecimento de Água/normas
7.
Huan Jing Ke Xue ; 26(1): 76-83, 2005 Jan.
Artigo em Chinês | MEDLINE | ID: mdl-15859413

RESUMO

Reducing excess sludge production induced by Oligochaete is carried out in a pilot scale of conventional activated sludge (CAS) reactor for 345 days. Worms occurred for nearly whole operating period except for the first 20 days, and continuously maintained at high density (over 30 total worms/mgVSS in aeration tank) for 172 days. Three types of worm were found, Aeolosoma hemprichicii and Nais elinguis alternatively dominated, but Pristina aequiseta occasionally presented. High worm density greatly contributes to both reducing sludge production and improving the sludge settling characteristics, and Nais elinguis had more potential for sludge reduction than Aeolosoma. Worm growth had impacts on effluent quality, and Nais elinguis growth affected effluent quality much more than Aeolosoma. Worm growth does not disturb the nitrification process, but PO4(3-) -P release into effluent occurres as Nais elinguis dominated. Analysis of factors affecting worm growth show that only SRT has no any impact on neither Aeolosoma nor Nais, however, both temperature and HRT can affect their growth very much.


Assuntos
Poluição Ambiental/prevenção & controle , Oligoquetos/metabolismo , Esgotos/análise , Eliminação de Resíduos Líquidos/métodos , Purificação da Água/métodos , Animais , Biodegradação Ambiental , Oligoquetos/crescimento & desenvolvimento , Temperatura
8.
Huan Jing Ke Xue ; 25(3): 78-83, 2004 May.
Artigo em Chinês | MEDLINE | ID: mdl-15327259

RESUMO

An enhanced mechanical-cleaning membrane module M1 and a mechanical-cleaning membrane module M2 were designed in this research. An orthogonal array design was adopted to investigate effects of operational parameters including aeration intensity, membrane flux, MLSS, ratio of suction time and non-suction time on membrane filtration of two membrane module of M1 and M2. The results showed that M1 could weaken the negative influence of disadvantage parameters including high MLSS, high membrane flux, and low aeration intensity on membrane flux. M1 and M2 module both maintained a high flux of 40 L/(h x m2) under the conditions of MLSS 6 g/L, aeration 0.5 m3/h, ratio of suction time and non-suction time of 12/1, which was selected by the study of orthogonal array. Resistance distribution showed that the mechanism of mechanical-cleaning help to remove the sludge cake pollution on membrane surface.


Assuntos
Reatores Biológicos , Eliminação de Resíduos Líquidos/instrumentação , Purificação da Água/instrumentação , Filtração
9.
J Environ Sci (China) ; 15(4): 449-55, 2003 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-12974303

RESUMO

A pilot-scale (10 m3/d) anoxic/oxic membrane bioreactor (A/O MBR) was tested for dyeing wastewater treatment of woolen mill without wasting sludge in 125 days operation. Results showed that the effluent quality was excellent, i.e. effluent COD less than 25 mg/L, BOD5 under 5 mg/L, turbidity lower than 0.65 NTU, and colour less than 30 DT, and met with the reuse water standard of China. The removal rates of COD, BOD5, colour, and turbidity were 92.4%, 98.4%, 74% and 98.9%, respectively. Constant-flux operation mode was carried out in this study, and backwash was effective for reducing membrane fouling and maintaining constant flux. Membrane fouling had heavy impact on energy consumption. More attention should be paid on pipe selection and design for the sidestream MBR system, too.


Assuntos
Reatores Biológicos , Eliminação de Resíduos Líquidos/métodos , Purificação da Água/métodos , Corantes/isolamento & purificação , Resíduos Industriais , Membranas Artificiais , Oxigênio/metabolismo , Indústria Têxtil , Poluição da Água/prevenção & controle
10.
J Environ Sci (China) ; 14(4): 501-7, 2002 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-12491724

RESUMO

Based on the microorganism kinetic model, the formula for computing hydraulic retention time in a membrane bioreactor system (MBR) is derived. With considering HRT as an evaluation index a combinational approach was used to discuss factors which have an effect on MBR. As a result, the influencing factors were listed in order from strength to weakness as: maximum specific removal rate K, saturation constant Ks, maintenance coefficient m, maximum specific growth rate mu m and observed yield coefficient Yobs. Moreover, the formula was simplified, whose parameters were experimentally determined in petrochemical wastewater treatment. The simplified formula is theta = 1.1(1/beta-1) (Ks + S)/KX0, for petrochemical wastewater treatment K and Ks equaled 0.185 and 154.2, respectively.


Assuntos
Reatores Biológicos , Modelos Teóricos , Purificação da Água/métodos , Resíduos Industriais , Cinética , Análise Numérica Assistida por Computador , Petróleo/metabolismo , Poluentes Químicos da Água/metabolismo , Purificação da Água/instrumentação