Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 60
Filtrar
1.
BMJ Open ; 14(6): e081933, 2024 Jun 12.
Artigo em Inglês | MEDLINE | ID: mdl-38866577

RESUMO

INTRODUCTION: Hepatic artery complications (HACs), such as a thrombosis or stenosis, are serious causes of morbidity and mortality after paediatric liver transplantation (LT). This study will investigate the incidence, current management practices and outcomes in paediatric patients with HAC after LT, including early and late complications. METHODS AND ANALYSIS: The HEPatic Artery stenosis and Thrombosis after liver transplantation In Children (HEPATIC) Registry is an international, retrospective, multicentre, observational study. Any paediatric patient diagnosed with HAC and treated for HAC (at age <18 years) after paediatric LT within a 20-year time period will be included. The primary outcomes are graft and patient survivals. The secondary outcomes are technical success of the intervention, primary and secondary patency after HAC intervention, intraprocedural and postprocedural complications, description of current management practices, and incidence of HAC. ETHICS AND DISSEMINATION: All participating sites will obtain local ethical approval and (waiver of) informed consent following the regulations on the conduct of observational clinical studies. The results will be disseminated through scientific presentations at conferences and through publication in peer-reviewed journals. TRIAL REGISTRATION NUMBER: The HEPATIC registry is registered at the ClinicalTrials.gov website; Registry Identifier: NCT05818644.


Assuntos
Artéria Hepática , Transplante de Fígado , Complicações Pós-Operatórias , Sistema de Registros , Trombose , Humanos , Transplante de Fígado/efeitos adversos , Estudos Retrospectivos , Criança , Incidência , Complicações Pós-Operatórias/epidemiologia , Complicações Pós-Operatórias/etiologia , Trombose/etiologia , Trombose/epidemiologia , Adolescente , Pré-Escolar , Feminino , Masculino , Constrição Patológica/etiologia , Lactente , Estudos Multicêntricos como Assunto
2.
World J Transplant ; 14(1): 88734, 2024 Mar 18.
Artigo em Inglês | MEDLINE | ID: mdl-38576759

RESUMO

BACKGROUND: Biliary atresia (BA) is the most common indication for pediatric liver trans plantation, although portoenterostomy is usually performed first. However, due to the high failure rate of portoenterostomy, liver transplantation has been advocated as the primary procedure for patients with BA. It is still unclear if a previous portoenterostomy has a negative impact on liver transplantation outcomes. AIM: To investigate the effect of prior portoenterostomy in infants un dergoing liver transplantation for BA. METHODS: This was a retrospective cohort study of 42 pediatric patients with BA who underwent primary liver transplantation from 2013 to 2023 at a single tertiary center in Brazil. Patients with BA were divided into two groups: Those under going primary liver transplantation without portoenterostomy and those undergoing liver transplantation with prior portoenterostomy. Continuous variables were compared using the Student's t-test or the Kruskal-Wallis test, and categorical variables were compared using the χ2 or Fisher's exact test, as appropriate. Multivariable Cox regression analysis was performed to determine risk factors for portal vein thrombosis. Patient and graft survival analyses were conducted with the Kaplan-Meier product-limit estimator, and patient subgroups were compared using the two-sided log-rank test. RESULTS: Forty-two patients were included in the study (25 [60%] girls), 23 undergoing liver transplantation without prior portoenterostomy, and 19 undergoing liver transplantation with prior portoenterostomy. Patients with prior portoenterostomy were older (12 vs 8 months; P = 0.02) at the time of liver transplantation and had lower Pediatric End-Stage Liver Disease scores (13.2 vs 21.4; P = 0.01). The majority of the patients (35/42, 83%) underwent living-donor liver transplantation. The group of patients without prior portoenterostomy appeared to have a higher incidence of portal vein thrombosis (39 vs 11%), but this result did not reach statistical significance. Prior portoenterostomy was not a protective factor against portal vein thrombosis in the multivariable analysis after adjusting for age at liver transplantation, graft-to-recipient weight ratio, and use of vascular grafts. Finally, the groups did not significantly differ in terms of post-transplant survival. CONCLUSION: In our study, prior portoenterostomy did not significantly affect the outcomes of liver transplantation.

3.
Eur J Ophthalmol ; : 11206721241236919, 2024 Mar 05.
Artigo em Inglês | MEDLINE | ID: mdl-38444247

RESUMO

BACKGROUND: recently much studies evidenced the potential role of photo-biomodulation (PBM) in patients affected by Age-related Macular Degeneration (AMD). We designed a new wearable device for self-medication that employs the same broadband red light described in literature, but with extremely low irradiance. AIM: to demonstrate the safety and effectiveness of low-fluence light stimulations emitted by a LED source with appropriate wavelengths through our new device in improving short-term visual function in patients affected by severe non neovascular AMD. MATERIALS AND METHODS: we prospectively enrolled patients affected by severe non-neovascular AMD with a relative sparing of the foveal region. All the patients were randomly assigned in placebo or in treatment group. The treatment consisted of 10 sessions of 10-min each, using the new device comprised of micro-LEDs that emitted light onto an amorphous support assembled within Metallic eyeglasses. The placebo group blindly underwent the same number of PBM sessions with the micro-LED turned off. Before and after each placebo/treatment sessions all the patients received: optical coherence tomography (OCT), Best-Corrected Visual Acuity (BCVA) and Microperimetry (MP). RESULTS: no significant differences in the anatomical parameters were observed in the two groups. The MP mean sensitivity and the central visual function both far and near significantly improved in the treated group (respectively p < 0.001, p < 0.001). CONCLUSIONS: our pivotal demonstrated that the LED PBM delivered through our new device is a safe and effective tool for improving short-term visual function in patients affected by severe non-neovascular AMD.

4.
Phys Eng Sci Med ; 47(2): 385-401, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38231358

RESUMO

The power consumption of portable gadgets, implantable medical devices (IMDs) and wireless sensor nodes (WSNs) has reduced significantly with the ongoing progression in low-power electronics and the swift advancement in nano and microfabrication. Energy harvesting techniques that extract and convert ambient energy into electrical power have been favored to operate such low-power devices as an alternative to batteries. Due to the expanded availability of radio frequency (RF) energy residue in the surroundings, radio frequency energy harvesters (RFEHs) for low-power devices have garnered notable attention in recent times. This work establishes a review study of RFEHs developed for the utilization of low-power devices. From the modest single band to the complex multiband circuitry, the work reviews state of the art of required circuitry for RFEH that contains a receiving antenna, impedance matching circuit, and an AC-DC rectifier. Furthermore, the advantages and disadvantages associated with various circuit architectures are comprehensively discussed. Moreover, the reported receiving antenna, impedance matching circuit, and an AC-DC rectifier are also compared to draw conclusions towards their implementations in RFEHs for sensors and biomedical devices applications.


Assuntos
Fontes de Energia Elétrica , Ondas de Rádio , Tecnologia sem Fio , Desenho de Equipamento , Tecnologia sem Fio/instrumentação
5.
RSC Adv ; 13(31): 21277-21282, 2023 Jul 12.
Artigo em Inglês | MEDLINE | ID: mdl-37456547

RESUMO

This paper presents the analytical derivation of spreading resistance expressions for diverse geometries of a conducting probe submerged in a lossy medium. Resulting equations can be used to calibrate scanning impedance/scanning microwave microscopes operating in liquid. The expressions are systematically validated through numerical and experimental methods for the calibration of an inverted Scanning Microwave Microscope (iSMM) when operating in a lossy saline medium, such as Dulbecco's Modified Eagle Medium (DMEM), a widely used medium for supporting the growth of biological cells. The calibration process within DMEM plays an important role in the quantitative local evaluation of electromagnetic properties of biological samples under physiological conditions. Additionally, measurements are performed in distilled water for comparative analysis.

6.
BMJ Open ; 13(7): e066343, 2023 07 27.
Artigo em Inglês | MEDLINE | ID: mdl-37500271

RESUMO

INTRODUCTION: Portal vein obstruction (PVO) consists of anastomotic stenosis and thrombosis, which occurs due to a progression of the former. The aim of this large-scale international study is to assess the prevalence, current management practices and efficacy of treatment in patients with PVO. METHODS AND ANALYSIS: The Portal vein Obstruction Revascularisation Therapy After Liver transplantation registry will facilitate an international, retrospective, multicentre, observational study, with 25 centres around the world already actively involved. Paediatric patients (aged <18 years) with a diagnosed PVO between 1 January 2001 and 1 January 2021 after liver transplantation will be eligible for inclusion. The primary endpoints are the prevalence of PVO, primary and secondary patency after PVO intervention and current management practices. Secondary endpoints are patient and graft survival, severe complications of PVO and technical success of revascularisation techniques. ETHICS AND DISSEMINATION: Medical Ethics Review Board of the University Medical Center Groningen has approved the study (METc 2021/072). The results of this study will be disseminated via peer-reviewed publications and scientific presentations at national and international conferences. TRIAL REGISTRATION NUMBER: Netherlands Trial Register (NL9261).


Assuntos
Hepatopatias , Transplante de Fígado , Doenças Vasculares , Humanos , Criança , Transplante de Fígado/efeitos adversos , Veia Porta , Estudos Retrospectivos , Prevalência , Doenças Vasculares/epidemiologia , Doenças Vasculares/etiologia , Doenças Vasculares/cirurgia , Sistema de Registros , Estudos Observacionais como Assunto , Estudos Multicêntricos como Assunto
7.
Sensors (Basel) ; 23(9)2023 Apr 28.
Artigo em Inglês | MEDLINE | ID: mdl-37177559

RESUMO

Many skeletal muscle diseases such as muscular dystrophy, myalgic encephalomyelitis/chronic fatigue syndrome (ME/CFS), and sarcopenia share the dysregulation of calcium (Ca2+) as a key mechanism of disease at a cellular level. Cytosolic concentrations of Ca2+ can signal dysregulation in organelles including the mitochondria, nucleus, and sarcoplasmic reticulum in skeletal muscle. In this work, a treatment is applied to mimic the Ca2+ increase associated with these atrophy-related disease states, and broadband impedance measurements are taken for single cells with and without this treatment using a microfluidic device. The resulting impedance measurements are fitted using a single-shell circuit simulation to show calculated electrical dielectric property contributions based on these Ca2+ changes. From this, similar distributions were seen in the Ca2+ from fluorescence measurements and the distribution of the S-parameter at a single frequency, identifying Ca2+ as the main contributor to the electrical differences being identified. Extracted dielectric parameters also showed different distribution patterns between the untreated and ionomycin-treated groups; however, the overall electrical parameters suggest the impact of Ca2+-induced changes at a wider range of frequencies.


Assuntos
Fibras Musculares Esqueléticas , Músculo Esquelético , Ionomicina/farmacologia , Ionomicina/metabolismo , Músculo Esquelético/fisiologia , Linhagem Celular , Análise Espectral , Cálcio/metabolismo
8.
Pflugers Arch ; 475(6): 691-709, 2023 06.
Artigo em Inglês | MEDLINE | ID: mdl-37156970

RESUMO

Extracellular vesicles (EVs) enriched with bioactive molecules have gained considerable attention in nanotechnology because they are critical to intercellular communication while maintaining low immunological impact. Among biological matrices, urine has emerged as a noninvasive source of extracellular-contained liquid biopsy, currently of interest as a readout for physiological adaptations. Therefore, we aimed to evaluate chronic adaptations of endurance sport practice in terms of urinary EV parameters and evaluated by food consumption assessment. Two balanced groups of 13 inactive controls vs. triathlon athletes were enrolled; their urinary EVs were obtained by differential ultracentrifugation and analyzed by dynamic light scattering and transmission electron and atomic force microscopy. The cargo was analyzed by means of purine and miRNA content through HPLC-UV and qRT-PCR. Specific urinary EV signatures differentiated inactive versus endurance-trained in terms of peculiar shape. Particularly, a spheroid shape, smaller size, and lower roughness characterize EVs from triathletes. Metabolic and regulatory miRNAs often associated with skeletal muscle (i.e., miR378a-5p, miR27a-3p, miR133a, and miR206) also accounted for a differential signature. These miRNAs and guanosine in urinary EVs can be used as a readout for metabolic status along with the shape and roughness of EVs, novel informative parameters that are rarely considered. The network models allow scholars to entangle nutritional and exercise factors related to EVs' miRNA and purine content to depict metabolic signatures. All in all, multiplex biophysical and molecular analyses of urinary EVs may serve as promising prospects for research in exercise physiology.


Assuntos
Líquidos Corporais , Vesículas Extracelulares , MicroRNAs , Sistema Urinário , Humanos , MicroRNAs/metabolismo , Sistema Urinário/metabolismo , Vesículas Extracelulares/metabolismo , Líquidos Corporais/metabolismo , Purinas/metabolismo
10.
Nano Today ; 48: 101729, 2023 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-36536857

RESUMO

Reliable point-of-care (POC) rapid tests are crucial to detect infection and contain the spread of Severe Acute Respiratory Syndrome Coronavirus 2 (SARS-CoV-2). The emergence of several variants of concern (VOC) can reduce binding affinity to diagnostic antibodies, limiting the efficacy of the currently adopted tests, while showing unaltered or increased affinity for the host receptor, angiotensin converting enzyme 2 (ACE2). We present a graphene field-effect transistor (gFET) biosensor design, which exploits the Spike-ACE2 interaction, the crucial step for SARS-CoV-2 infection. Extensive computational analyses show that a chimeric ACE2-Fragment crystallizable (ACE2-Fc) construct mimics the native receptor dimeric conformation. ACE2-Fc functionalized gFET allows in vitro detection of the trimeric Spike protein, outperforming functionalization with a diagnostic antibody or with the soluble ACE2 portion, resulting in a sensitivity of 20 pg/mL. Our miniaturized POC biosensor successfully detects B.1.610 (pre-VOC), Alpha, Beta, Gamma, Delta, Omicron (i.e., BA.1, BA.2, BA.4, BA.5, BA.2.75 and BQ.1) variants in isolated viruses and patient's clinical nasopharyngeal swabs. The biosensor reached a Limit Of Detection (LOD) of 65 cps/mL in swab specimens of Omicron BA.5. Our approach paves the way for a new and reusable class of highly sensitive, rapid and variant-robust SARS-CoV-2 detection systems.

11.
Sensors (Basel) ; 22(24)2022 Dec 08.
Artigo em Inglês | MEDLINE | ID: mdl-36559977

RESUMO

Scanning microwave microscopy (SMM) is a novel metrological tool that advances the quantitative, nanometric, high-frequency, electrical characterization of a broad range of materials of technological importance. In this work, we report an inverted near-field scanning microwave microscopy (iSMM) investigation of a graphene oxide-based epoxy nanocomposite material at a nanoscopic level. The high-resolution spatial mapping of local conductance provides a quantitative analysis of the sample's electrical properties. In particular, the electrical conductivity in the order of ∼10-1 S/m as well as the mapping of the dielectric constant with a value of ∼4.7 ± 0.2 are reported and validated by the full-wave electromagnetic modeling of the tip-sample interaction.

12.
ACS Appl Mater Interfaces ; 13(45): 53986-53995, 2021 Nov 17.
Artigo em Inglês | MEDLINE | ID: mdl-34751024

RESUMO

Metal-organic frameworks (MOFs) are excellent platforms to design hybrid electrolytes for Li batteries with liquid-like transport and stability against lithium dendrites. We report on Li+ dynamics in quasi-solid electrolytes consisting in Mg-MOF-74 soaked with LiClO4-propylene carbonate (PC) and LiClO4-ethylene carbonate (EC)/dimethyl carbonate (DMC) solutions by combining studies of ion conductivity, nuclear magnetic resonance (NMR) characterization, and spin relaxometry. We investigate nanoconfinement of liquid inside MOFs to characterize the adsorption/solvation mechanism at the basis of Li+ migration in these materials. NMR supports that the liquid is nanoconfined in framework micropores, strongly interacting with their walls and that the nature of the solvent affects Li+ migration in MOFs. Contrary to the "free'' liquid electrolytes, faster ion dynamics and higher Li+ mobility take place in LiClO4-PC electrolytes when nanoconfined in MOFs demonstrating superionic conductor behavior (conductivity σrt > 0.1 mS cm-1, transport number tLi+ > 0.7). Such properties, including a more stable Li electrodeposition, make MOF-hybrid electrolytes promising for high-power and safer lithium-ion batteries.

13.
Small ; 17(29): e2101253, 2021 07.
Artigo em Inglês | MEDLINE | ID: mdl-34121314

RESUMO

Electrochemical microscopy techniques have extended the understanding of surface chemistry to the micrometer and even sub-micrometer level. However, fundamental questions related to charge transport at the solid-electrolyte interface, such as catalytic reactions or operation of individual ion channels, require improved spatial resolutions down to the nanoscale. A prerequisite for single-molecule electrochemical sensitivity is the reliable detection of a few electrons per second, that is, currents in the atto-Ampere (10-18 A) range, 1000 times below today's electrochemical microscopes. This work reports local cyclic voltammetry (CV) measurements at the solid-liquid interface on ferrocene self-assembled monolayer (SAM) with sub-atto-Ampere sensitivity and simultaneous spatial resolution < 80 nm. Such sensitivity is obtained through measurements of the charging of the local faradaic interface capacitance at GHz frequencies. Nanometer-scale details of different molecular organizations with a 19% packing density difference are resolved, with an extremely small dispersion of the molecular electrical properties. This is predicted previously based on weak electrostatic interactions between neighboring redox molecules in a SAM configuration. These results open new perspectives for nano-electrochemistry like the study of quantum mechanical resonance in complex molecules and a wide range of applications from electrochemical catalysis to biophysics.


Assuntos
Elétrons , Nanotecnologia , Capacitância Elétrica , Eletroquímica , Oxirredução
14.
Anal Chim Acta ; 1173: 338678, 2021 Aug 15.
Artigo em Inglês | MEDLINE | ID: mdl-34172152

RESUMO

Oxidative stress (OS) is one of the leading causes of cytotoxicity and is linked to many human physio-pathological conditions. In particular, myalgic encephalomyelitis/chronic fatigue syndrome (ME/CFS) induced by OS is debilitating to quality of life, while no clear biological markers have been identified for diagnostic measures. Recently, impedance measurements of peripheral blood cells of ME/CFS patients have been shown as a promising approach to diagnose the disease. Inspired by this study and aiming to interrogate muscle cells directly, we investigated if broadband measurements of single muscle cells could differentiate normal and oxidatively stressed cell populations. We first optimized a protocol through H2O2 treatment to introduce oxidative stress to cultured rat L6 skeletal muscle cells. The treated cells were further characterized through broadband impedance spectroscopy of single cells using a microfluidic lab-on-a-chip system. The resulting dielectric properties of cytoplasm permittivity and conductivity are electrically distinct from normally cultured cells. The reflection and transmission coefficients, ΔS11 and ΔS21, of the normal cells are tightly clustered and closely resemble those of the cell-free solution across the frequency range of 9 kHz to 9 GHz. On the other hand, dielectric properties of the oxidized cells have a wide distribution in the GHz range, deviating both in the positive and negative directions from the normally cultured cells. Simulation results guide our hypothesis that the dielectric differences could be linked to ion alterations, while calcium imaging directly supports the contribution of calcium flux to the observed deviation of S parameters. The unique electrical profile associated with oxidized cells in the GHz frequencies provide a framework for future development of technologies to diagnose oxidative-stress related diseases such as ME/CFS.


Assuntos
Síndrome de Fadiga Crônica , Qualidade de Vida , Impedância Elétrica , Humanos , Músculo Esquelético , Estresse Oxidativo
15.
J Opt Soc Am A Opt Image Sci Vis ; 38(3): 378-386, 2021 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-33690467

RESUMO

The present paper describes a novel implementation of the continuous phase shifting method (PSM), named heterodyne holography, in a scanning probe microscope configuration, able to retrieve the complex scattered field in on-axis configuration. This can be achieved by acquiring a continuous sequence of holograms at different wavelengths in just a single scan through the combination of scanning interference microscopy and a low-coherent signal acquired in the frequency domain. This method exploits the main advantages of the phase shifting technique and avoids some limits relative to off-axis holography in providing quantitative phase imaging.

16.
J Wound Care ; 29(12): 692-706, 2020 Dec 02.
Artigo em Inglês | MEDLINE | ID: mdl-33320742

RESUMO

OBJECTIVE: To report the clinical validation of an innovative, artificial intelligence (AI)-powered, portable and non-invasive medical device called Wound Viewer. The AI medical device uses dedicated sensors and AI algorithms to remotely collect objective and precise clinical data, including three-dimensional (3D) wound measurements, tissue composition and wound classification through the internationally recognised Wound Bed Preparation (WBP) protocol; this data can then be shared through a secure General Data Protection Regulation (GDPR)- and Health Insurance Portability and Accountability Act (HIPAA)-compliant data transfer system. This trial aims to test the reliability and precision of the AI medical device and its ability to aid health professionals in clinically evaluating wounds as efficiently remotely as at the bedside. METHOD: This non-randomised comparative clinical trial was conducted in the Clinica San Luca (Turin, Italy). Patients were divided into three groups: (i) patients with venous and arterial ulcers in the lower limbs; (ii) patients with diabetes and presenting with diabetic foot syndrome; and (iii) patients with pressure ulcers. Each wound was evaluated for area, depth, volume and WBP wound classification. Each patient was examined once and the results, analysed by the AI medical device, were compared against data obtained following visual evaluation by the physician and research team. The area and depth were compared with a Kruskal-Wallis one-way analysis of variations in the obtained distribution (expected p-value>0.1 for both tests). The WBP classification and tissue segmentation were analysed by directly comparing the classification obtained by the AI medical device against that of the testing physician. RESULTS: A total of 150 patients took part in the trial. The results demonstrated that the AI medical device's AI algorithm could acquire objective clinical parameters in a completely automated manner. The AI medical device reached 97% accuracy against the WBP classification and tissue segmentation analysis compared with that performed in person by the physician. Moreover, data regarding the measurements of the wounds, as analysed through the Kruskal-Wallis technique, showed that the data distribution proved comparable with the other methods of measurement previously clinically validated in the literature (p=0.9). CONCLUSION: These findings indicate that remote wound assessment undertaken by physicians is as effective through the AI medical device as bedside examination, and that the device was able to assess wounds and provide a precise WBP wound classification. Furthermore, there was no need for manual data entry, thereby reducing the risk of human error while preserving high-quality clinical diagnostic data.


Assuntos
Inteligência Artificial , Pé Diabético/diagnóstico , Telemedicina , Humanos , Itália , Reprodutibilidade dos Testes , Tecnologia , Estados Unidos
17.
Adv Healthc Mater ; 9(19): e2000670, 2020 10.
Artigo em Inglês | MEDLINE | ID: mdl-32864893

RESUMO

The current standard for cell encapsulation platforms is enveloping cells in semipermeable membranes that physically isolate transplanted cells from the host while allowing for oxygen and nutrient diffusion. However, long-term viability and function of encapsulated cells are compromised by insufficient oxygen and nutrient supply to the graft. To address this need, a strategy to achieve enhanced vascularization of a 3D-printed, polymeric cell encapsulation platform using platelet-rich plasma (PRP) and mesenchymal stem cells (MSCs) is investigated. The study is conducted in rats and, for clinical translation relevance, in nonhuman primates (NHP). Devices filled with PRP, MSCs, or vehicle hydrogel are subcutaneously implanted in rats and NHP and the amount and maturity of penetrating blood vessels assessed via histopathological analysis. In rats, MSCs drive the strongest angiogenic response at early time points, with the highest vessel density and endothelial nitric oxide synthase (eNOS) expression. In NHP, PRP and MSCs result in similar vessel densities but incorporation of PRP ensues higher levels of eNOS expression. Overall, enrichment with PRP and MSCs yields extensive, mature vascularization of subcutaneous cell encapsulation devices. It is postulated that the individual properties of PRP and MSCs can be leveraged in a synergistic approach for maximal vascularization of cell encapsulation platforms.


Assuntos
Transplante de Células-Tronco Mesenquimais , Células-Tronco Mesenquimais , Plasma Rico em Plaquetas , Animais , Encapsulamento de Células , Hidrogéis , Impressão Tridimensional , Ratos
18.
Biomaterials ; 257: 120232, 2020 10.
Artigo em Inglês | MEDLINE | ID: mdl-32768727

RESUMO

Cell encapsulation is an attractive transplantation strategy to treat endocrine disorders. Transplanted cells offer a dynamic and stimulus-responsive system that secretes therapeutics based on patient need. Despite significant advancements, a challenge in allogeneic cell encapsulation is maintaining sufficient oxygen and nutrient exchange, while providing protection from the host immune system. To this end, we developed a subcutaneously implantable dual-reservoir encapsulation system integrating in situ prevascularization and local immunosuppressant delivery, termed NICHE. NICHE structure is 3D-printed in biocompatible polyamide 2200 and comprises of independent cell and drug reservoirs separated by a nanoporous membrane for sustained local release of immunosuppressant. Here we present the development and characterization of NICHE, as well as efficacy validation for allogeneic cell transplantation in an immunocompetent rat model. We established biocompatibility and mechanical stability of NICHE. Further, NICHE vascularization was achieved with the aid of mesenchymal stem cells. Our study demonstrated sustained local elution of immunosuppressant (CTLA4Ig) into the cell reservoir protected transcutaneously-transplanted allogeneic Leydig cells from host immune destruction during a 31-day study, and reduced systemic drug exposure by 12-fold. In summary, NICHE is the first encapsulation platform achieving both in situ vascularization and immunosuppressant delivery, presenting a viable strategy for allogeneic cell transplantation.


Assuntos
Transplante de Células-Tronco Hematopoéticas , Preparações Farmacêuticas , Animais , Encapsulamento de Células , Imunossupressores , Masculino , Ratos , Transplante Homólogo
19.
Kidney Int Rep ; 5(5): 580-585, 2020 May.
Artigo em Inglês | MEDLINE | ID: mdl-32292866

RESUMO

The severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2), also known as coronavirus disease (COVID-19), is a major pandemic challenging health care systems around the world. The optimal management of patients infected with COVID-19 is still unclear, although the consensus is moving toward the need of a biphasic approach. During the first phase of the disease (from onset of the symptoms up to 7-10 days) viral-induced effects are prominent, with the opportunity to institute antiviral therapy. In the second inflammatory phase of the disease, immunosuppressive strategies (for example with glucocorticoids or anticytokine drugs) may be considered. This latter stage is characterized by the development of progressive lung involvement with increasing oxygen requirements and occasionally signs of the hemophagocytic syndrome. The management of the disease in patients with kidney disease is even more challenging, especially in those who are immunosuppressed or with severe comorbidities. Here we present the therapeutic approach used in Brescia (Italy) for managing patients infected with COVID-19 who underwent kidney transplantation and are receiving hemodialysis. Furthermore, we provide some clinical and physiopathological background, as well as preliminary outcome data of our cohort, to better clarify the pathogenesis of the disease and clinical management.

20.
G Ital Nefrol ; 37(2)2020 Apr 09.
Artigo em Italiano | MEDLINE | ID: mdl-32281754

RESUMO

We are in the midst of a health emergency that is totally new for us all and that requires a concerted effort, especially when it comes to safeguarding patients on hemodialysis, and kidney transplant recipients. Brescia is currently a very active cluster of infections (2918 cases on the 17/03/2020), second only to Bergamo. The way our structure is organised has allowed us to treat nephropathic patients directly within the Nephrology Unit, following of course a great deal of reshuffling; at the moment, we are treating 21 transplanted patients and 17 on hemodialysis. This has led us to adopt a systematic approach to handling this emergency, not only in managing inpatients, but also in researching the new disease. Our approach is mirrored in the guidelines attached to this article, originally intended for internal use only but potentially very useful to our colleagues, as they face the same exact problems. We have also started collecting data on our positive patients with the aim of understanding better the functioning of this disease and how best to manage it. If anyone is interested, we ask you to please get in touch with us, so we can coordinate our efforts.


Assuntos
Betacoronavirus , Infecções por Coronavirus/complicações , Falência Renal Crônica/terapia , Transplante de Rim , Pneumonia Viral/complicações , Diálise Renal , COVID-19 , Infecções por Coronavirus/epidemiologia , Humanos , Hospedeiro Imunocomprometido , Itália/epidemiologia , Falência Renal Crônica/virologia , Pandemias , Pneumonia Viral/epidemiologia , SARS-CoV-2
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA