Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
1.
J Am Heart Assoc ; 13(10): e034552, 2024 May 21.
Artigo em Inglês | MEDLINE | ID: mdl-38726901

RESUMO

BACKGROUND: Fractional flow reserve (FFR) is the ratio of blood pressure measured distal to a stenosis and pressure proximal to a stenosis. FFR can be estimated noninvasively using computed tomography (CT) although the usefulness of this technique remains controversial. This meta-analysis evaluated the agreement of FFR estimated by CT (FFR-CT) with invasively measured FFR. The study also evaluated the diagnostic accuracy of FFR-CT, defined as the ability of FFR-CT to classify lesions as hemodynamically significant (invasive FFR ≤0.8) or insignificant (invasive FFR >0.8). METHODS AND RESULTS: Forty-three studies reporting on 7291 blood vessels from 5236 patients were included. A moderate positive linear relationship between FFR-CT and invasively measured FFR was observed (Spearman correlation coefficient: 0.67). Agreement between the 2 measures increased as invasively measured FFR values approached 1. The overall diagnostic accuracy, sensitivity and specificity of FFR-CT were 82.2%, 80.9%, and 83.1%, respectively. Diagnostic accuracy of 90% could be demonstrated for FFR-CT values >0.90 and <0.49. The diagnostic accuracy of off-site tools was 79.4% and the diagnostic accuracy of on-site tools was 84.1%. CONCLUSIONS: The agreement between FFR-CT and invasive FFR is moderate although agreement is highest in vessels with FFR-CT >0.9. Diagnostic accuracy varies widely with FFR-CT value but is above 90% for FFR-CT values >0.90 and <0.49. Furthermore, on-site and off-site tools have similar performance. Ultimately, FFR-CT may be a useful adjunct to CT coronary angiography as a gatekeeper for invasive coronary angiogram.


Assuntos
Angiografia por Tomografia Computadorizada , Angiografia Coronária , Estenose Coronária , Reserva Fracionada de Fluxo Miocárdico , Reserva Fracionada de Fluxo Miocárdico/fisiologia , Humanos , Estenose Coronária/fisiopatologia , Estenose Coronária/diagnóstico por imagem , Estenose Coronária/diagnóstico , Angiografia Coronária/métodos , Angiografia por Tomografia Computadorizada/métodos , Valor Preditivo dos Testes , Cateterismo Cardíaco , Reprodutibilidade dos Testes , Doença da Artéria Coronariana/fisiopatologia , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/diagnóstico , Vasos Coronários/diagnóstico por imagem , Vasos Coronários/fisiopatologia , Índice de Gravidade de Doença , Tomografia Computadorizada por Raios X/métodos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA