RESUMO
Breastfeeding is the most appropriate source of a newborn's nutrition; among the plethora of its benefits, its modulation of circadian rhythmicity with melatonin as a potential neuroendocrine transducer has gained increasing interest. Transplacental transfer assures melatonin provision for the fetus, who is devoid of melatonin secretion. Even after birth, the neonatal pineal gland is not able to produce melatonin rhythmically for several months (with an even more prolonged deficiency following preterm birth). In this context, human breast milk constitutes the main natural source of melatonin: diurnal dynamic changes, an acrophase early after midnight, and changes in melatonin concentrations according to gestational age and during the different stages of lactation have been reported. Understudied thus far are the factors impacting on (changes in) melatonin content in human breast milk and their clinical significance in chronobiological adherence in the neonate: maternal as well as environmental aspects have to be investigated in more detail to guide nursing mothers in optimal feeding schedules which probably means a synchronized instead of mistimed feeding practice. This review aims to be thought-provoking regarding the critical role of melatonin in chrononutrition during breastfeeding, highlighting its potential in circadian entrainment and therefore optimizing (neuro)developmental outcomes in the neonatal setting.
Assuntos
Aleitamento Materno , Ritmo Circadiano , Lactação , Melatonina , Leite Humano , Humanos , Melatonina/metabolismo , Melatonina/administração & dosagem , Leite Humano/química , Leite Humano/metabolismo , Ritmo Circadiano/fisiologia , Feminino , Recém-Nascido , Lactação/fisiologia , Fenômenos Fisiológicos da Nutrição do Lactente/fisiologiaRESUMO
CASE REPORT: Herein we present the case of a 33-year nulliparous woman at 21 weeks of gestation with mitral valve vegetation resulting from infective endocarditis. Due to the mother's critical condition caused by consecutive thromboembolic events, surgery with cardiopulmonary bypass was indicated. During surgery the fetus was monitored by a specialized obstetrician who repetitively measured the Doppler indices of the umbilical artery, Ductus venosus and uterine artery. Right after CO2 was insufflated into the operating area, the Doppler monitoring showed an increased Pulsatility Index of the Umbilical artery right before fetal distress with bradycardia occurred. A subsequent maternal arterial blood gas analysis showed an acidosis with hypercapnia. Consequently, the CO2 insufflation was stopped and the gas flow on the Heart Lung Machine increased. After regaining homeostasis of acidosis, the Doppler Indices and fetal heart rate recovered. The remaining surgery and postoperative course were uneventful. At the 37 weeks of gestation a healthy boy was delivered by Cesarean section and at the age of two years, the neurodevelopment was assessed, which indicated normal development in mental cognition, language and motoric. This report presents a periodic Doppler examination of the maternal and fetal circulation during surgery on CPB while also discussing the possible impact of fetal monitoring in managing open cardiac surgery in pregnancy.
Assuntos
Acidose , Procedimentos Cirúrgicos Cardíacos , Gravidez , Humanos , Feminino , Pré-Escolar , Cesárea , Dióxido de Carbono , Ultrassonografia Doppler , Procedimentos Cirúrgicos Cardíacos/efeitos adversos , Artérias Umbilicais/diagnóstico por imagem , Ultrassonografia Pré-Natal , Idade Gestacional , Velocidade do Fluxo SanguíneoRESUMO
OBJECTIVE: Enhanced recovery after surgery (ERAS) recommendations for cesarean section (ERAC), likely the most common reason for laparotomy in women, were issued in 2018-19. We examined how current perioperative management at cesarean section in Austrian hospitals aligns with ERAS recommendations. STUDY DESIGN: We surveyed the 21 largest public obstetric units in Austria for alignment with 20 of the 31 strong ERAS recommendations regarding perioperative maternal care at cesarean section. We also looked at how the German-language clinical guideline for cesarean section (AWMF Guideline Sectio caesarea) aligns with ERAS recommendations. RESULTS: The 21 obstetric units cared for about 51% of all births in Austria in 2019. Cesarean section rates ranged from 17.7% to 50.4%. All 21 units implemented the five strong recommendations regarding patient information and counselling, regional anesthesia, euvolemia and multimodal analgesia. The least implemented strong recommendation was the one for the use of pneumatic compression stockings to prevent thromboembolic disease (0/21 units). Overall, all 21 units implemented ≥11 and 13 (62%) implemented ≥15 (≥75%) of the 20 strong recommendations; no unit implemented all 20 strong recommendations. There were no differences in the implementation of strong recommendations according to hospital volume. CONCLUSIONS: Even in the absence of formal adoption of ERAS program for cesarean section many perioperative ERAS recommendations are already implemented in Austria. The least implemented recommendations were the use of pneumatic compression stockings (0 of 21 units) and immediate catheter removal (4 of 21 units). Only 10 of the 20 ERAS recommendations we looked at are included in the current German-language clinical guideline for cesarean section.
Assuntos
Analgesia , Cesárea , Gravidez , Feminino , Humanos , Áustria , Assistência Perioperatória , Manejo da DorRESUMO
This overview analyzes the data on the controversial therapy of iron substitution during pregnancy, the diagnosis of iron deficiency anemia and the indication-related therapy, and is the first recommendation issued by the OEGGG on the appropriate therapy. The effects of anemia during pregnancy on postnatal outcomes have been intensively investigated with heterogeneous results. A final scientific conclusion with regards to the "optimal" maternal hemoglobin level is limited by the heterogeneous results of various studies, many of which were conducted in emerging nations (with different dietary habits and structural differences in the respective healthcare systems). The current literature even suggests that there may be a connection between both decreased and increased maternal serum hemoglobin concentrations and unfavorable short-term and long-term neonatal outcomes. In Austria, 67 percent of pregnant women take pharmacological supplements or use a variety of dietary supplements. Clinically, the prevalence of maternal anemia is often overestimated, leading to overtreatment of pregnant women (iron substitution without a medical indication). To obtain a differential diagnosis, a workup of the indications for treatment should be carried out prior to initiating any form of iron substitution during pregnancy. If treatment is medically indicated, oral iron substitution is usually sufficient. Because of the restricted approval and potential side effects, medical indications for intravenous iron substitution should be limited. Intravenous iron substitution without a prior detailed diagnostic workup is an off-label use and should only be used in very limited cases, and women should be advised accordingly.
RESUMO
BACKGROUND: Spontaneous vaginal twin delivery after 32nd week of gestation is safe when first twin presenting cephalic. Aim of this study is to identify obstetric factors influencing the condition of second twin and to verify whether non-cephalic presentation and vaginal breech delivery of the second twin is safe. METHODS: This is a retrospective case controlled cohort study of 717 uncomplicated twin deliveries ≥32 + 0 weeks of gestation from 2005 to 2014 in two tertiary perinatal centers. Obstetric parameters were evaluated in three groups with descriptive, univariate logistic regression analysis for perinatal outcome of second twins. RESULTS: The three groups included twins delivered by elective cesarean section ECS (n = 277, 38.6%), by unplanned cesarean section UPC (n = 233, 32.5%) and vaginally (n = 207, 28.9%). Serious adverse fetal outcome is rare and we found no differences between the groups. Second twins after ECS had significant better umbilical artery UA pH (p < 0.001) and better Apgar compared to UPC (p = 0.002). Variables for a fetal population "at risk" for adverse neonatal outcome after vaginal delivery (UA pH < 7.20, Apgar 5´ < 9) were associated with higher gestational age (p = 0.001), longer twin-twin interval (p = 0.05) and vacuum extraction of twin A (p = 0.04). Non-cephalic presentation of second twins was not associated (UA pH < 7.20 OR 1.97, CI 95% 0.93-4.22, p = 0.07, Apgar 5´ < 9 OR 1.63, CI 95% 0.70-3.77, p = 0.25, Transfer to neonatal intermediate care unit p = 0.48). Twenty-one second twins (2,9%) were delivered by cesarean section following vaginal delivery of the first twin. Even though non-cephalic presentation was overrepresented in this subgroup, outcome variables were not significantly different compared to cephalic presentation. CONCLUSIONS: Even though elective cesarean means reduced stress for second twins this seems not to be clinically relevant. Non-cephalic presentation of the second twin does not significantly influence the perinatal outcome of the second twin but might be a risk factor for vaginal-cesarean birth.
Assuntos
Cesárea/estatística & dados numéricos , Parto Obstétrico/métodos , Apresentação no Trabalho de Parto , Gravidez de Gêmeos , Gêmeos/estatística & dados numéricos , Adulto , Estudos de Casos e Controles , Feminino , Idade Gestacional , Humanos , Recém-Nascido , Gravidez , Estudos RetrospectivosRESUMO
OBJECTIVES: To assess the inter- and intraobserver reliability of different fetal MRI measurements in cases of fetal brain malformations and to examine the concordance between ultrasonography (US) and MRI findings. METHODS: Fetal brain MRIs and US findings of 56 pregnant women were retrieved from the institutional database. Standardized fetal brain MRI measurements were performed by 4 observers, and the inter- and intraobserver reliability was determined. Additionally, US and MRI findings were retrospectively compared. RESULTS: The interobserver intraclass correlation coefficient (ICC) was above 0.9 for the cerebellum and posterior horn of the lateral ventricle. The measurements regarding the third ventricle (0.50), the fourth ventricle (0.58), and the corpus callosum (0.63) showed poor reliability. Overall, the intraobserver reliability was greater than the interobserver reliability. US and MRI findings were discordant in 29% of the cases with MRI rendering an extended diagnosis in 18%, a change of diagnosis in 3.6%, and excluding pathological findings suspected on US in 7.1%. CONCLUSIONS: Fetal MRI is a valuable complement to US in the investigation of fetal brain malformations. The reliability of most parameters was high, except for the measurements of the third and fourth ventricles and the corpus callosum.