Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 41
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
1.
Artigo em Inglês | MEDLINE | ID: mdl-38648136

RESUMO

The development of high-temperature nondestructive testing (NDT) requires ultrasonic transducers with good temperature resistance and high sensitivity for improved detection efficiency. Piezoelectric composite can improve the performance of transducers because of its high electromechanical coupling coefficient and adjustable acoustic impedance. In this study, 1-3-2 composites and 1-3-2 high-temperature composite ultrasonic transducers (HTCUTs) based on 0.36BiScO3-0.64PbTiO3 (BSPT), which are preferred piezoelectric materials at 200°C-300°C, and high-temperature epoxy with a center frequency of 6 MHz were designed and fabricated. From 25°C to 250°C, 1-3-2 composites show a higher electromechanical coupling coefficient kt especially at high temperatures (~0.53 at 25°C, and ~0.64 at 250°C) than monolithic BSPT (~0.5). The signal of the pulse-echo response of 1-3-2 HTCUTs is distinguishable up to 250 °C and remains stable (Vpp~500 mV) below 150°C, exhibiting higher sensitivity (improved by 7 dB) than that of monolithic BSPT high-temperature ultrasonic transducers (HTUTs). Bandwidth has been greatly enhanced especially at high temperatures (~103250°C) compared with that of monolithic BSPT HTUTs(~30250°C). To verify the excellent performance, B-mode scanning imaging measurement of a stepped steel block and defect location detection of a steel block were performed, showing the potential for high-temperature NDT applications.

2.
Gels ; 10(2)2024 Feb 12.
Artigo em Inglês | MEDLINE | ID: mdl-38391471

RESUMO

Cellulose aerogels have great prospects for noise reduction applications due to their sustainable value and superior 3D interconnected porous structures. The drying principle is a crucial factor in the preparation process for developing high-performance aerogels, particularly with respect to achieving high acoustic absorption properties. In this study, multifunctional cellulose nanocrystal (CNC) aerogels were conveniently prepared using two distinct freeze-drying principles: refrigerator conventional freezing (RCF) and liquid nitrogen unidirectional freezing (LnUF). The results indicate that the rapid RCF process resulted in a denser CNC aerogel structure with disordered larger pores, causing a stronger compressive performance (Young's modulus of 40 kPa). On the contrary, the LnUF process constructed ordered structures of CNC aerogels with a lower bulk density (0.03 g/cm3) and smaller apertures, resulting in better thermal stability, higher diffuse reflection across visible light, and especially increased acoustic absorption performance at low-mid frequencies (600-3000 Hz). Moreover, the dissipation mechanism of sound energy in the fabricated CNC aerogels is predicted by a designed porous media model. This work not only paves the way for optimizing the performance of aerogels through structure control, but also provides a new perspective for developing sustainable and efficient acoustic absorptive materials for a wide range of applications.

3.
Sci Adv ; 10(7): eadl2232, 2024 Feb 16.
Artigo em Inglês | MEDLINE | ID: mdl-38354252

RESUMO

Optical imaging and phototherapy in deep tissues face notable challenges due to light scattering. We use encoded acoustic holograms to generate three-dimensional acoustic fields within the target medium, enabling instantaneous and robust modulation of the volumetric refractive index, thereby noninvasively controlling the trajectory of light. Through this approach, we achieved a remarkable 24.3% increase in tissue heating rate in vitro photothermal effect tests on porcine skin. In vivo photoacoustic imaging of mouse brain vasculature exhibits an improved signal-to-noise ratio through the intact scalp and skull. These findings demonstrate that our strategy can effectively suppress light scattering in complex biological tissues by inducing low-angle scattering, achieving an effective depth reaching the millimeter scale. The versatility of this strategy extends its potential applications to neuroscience, lithography, and additive manufacturing.


Assuntos
Técnicas Fotoacústicas , Camundongos , Animais , Suínos , Técnicas Fotoacústicas/métodos , Fototerapia , Crânio , Acústica , Refratometria
4.
IEEE Trans Biomed Eng ; 71(2): 524-530, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-37656645

RESUMO

Ultra-high frequency (>100 MHz) acoustic waves feature biocompatibility and high sensitivity and allow biomedical imaging and acoustic tweezers. Primarily, excellent spatial resolution and broad bandwidth at ultra-high frequency is the goal for pathological research and cell selection at the cellular level. Here, we propose an efficient approach to visualize mouse brain atrophy by self-focused ultrasonic sensors at ultra-high frequency with ultra-broad bandwidth. The numerical models of geometry and theoretically predicted acoustic parameters for half-concave piezoelectric elements are calculated by the differential method, which agrees with measured results (lateral resolution: 24 µm, and bandwidth: 115% at -6 dB). Compared with the brain slices of 2-month-old mouse, the atrophy visualization of the 6-month-old mouse brain was realized by C-mode imaging with an acoustic microscopy system, which is a potential prospect for diagnosis and treatment of Alzheimer's disease (AD) combined with neuroscience. Meanwhile, the acoustic properties of the brain slices were quantitatively measured by the acoustic microscopy. These encouraging results demonstrate the promising application for high-resolution imaging in vitro biological tissue with ultra-high frequency self-focusing ultrasonic sensors.


Assuntos
Diagnóstico por Imagem , Ultrassom , Camundongos , Animais , Acústica , Encéfalo/diagnóstico por imagem , Atrofia
5.
Micromachines (Basel) ; 14(6)2023 May 31.
Artigo em Inglês | MEDLINE | ID: mdl-37374762

RESUMO

Focused ultrasound featuring non-destructive and high sensitivity has attracted widespread attention in biomedical and industrial evaluation. However, most traditional focusing techniques focus on the design and improvement of single-point focusing, neglecting the need to carry more dimensions of multifocal beams. Here we propose an automatic multifocal beamforming method, which is implemented using a four-step phase metasurface. The metasurface composed of four-step phases improves the transmission efficiency of acoustic waves as a matching layer and enhances the focusing efficiency at the target focal position. The change in the number of focused beams does not affect the full width at half maximum (FWHM), revealing the flexibility of the arbitrary multifocal beamforming method. Phase-optimized hybrid lenses reduce the sidelobe amplitude, and excellent agreement is observed between the simulation and experiments for triple-focusing beamforming metasurface lenses. The particle trapping experiment further validates the profile of the triple-focusing beam. The proposed hybrid lens can achieve flexible focusing in three dimensions (3D) and arbitrary multipoint, which may have potential prospects for biomedical imaging, acoustic tweezers, and brain neural modulation.

6.
Comput Biol Med ; 163: 107157, 2023 09.
Artigo em Inglês | MEDLINE | ID: mdl-37352636

RESUMO

Inspired by the optical imaging algorithm, the Fourier Ptychography (FP) algorithm is adopted to improve the resolution of ultrasonic array imaging. In the FP algorithm, the steady-state spectrum is utilized to recover the high-resolution ultrasonic images. Meanwhile, the parameters of FP algorithm are empirical, which can affect the imaging quality of ultrasonic array. Then the particle swarm optimization (PSO) algorithm is used to optimize the parameters of FP algorithm to further improve the imaging quality of ultrasonic array. The tungsten imaging experiments and pig eye imaging experiments are conducted to demonstrate the feasibility and effectiveness of the developed algorithm. In addition, the proposed algorithm and the coherent wave superposition (CWS) algorithm are both based on single plane wave (SPW) algorithms and they are then compared. The results show that the CWS algorithm and FP algorithm have good longitudinal and lateral resolutions, respectively. The particle swarm optimization-based FP (PSOFP) imaging algorithm has both excellent lateral and longitudinal resolutions. The average lateral resolution of PSOFP imaging algorithm is improved by 34.47% compared with CWS imaging algorithm in the tungsten wires experiments, and the lateral boundary structure width of the lens is improved by 49.48% in the pig eye experiments. The proposed algorithm can effectively improve the ultrasonic imaging quality for medical application.


Assuntos
Tungstênio , Ultrassom , Animais , Suínos , Algoritmos , Imagem Óptica
7.
Heliyon ; 9(3): e14227, 2023 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-36950590

RESUMO

The sound velocity in a medium is closely related to its material properties, including its composition, structure, density, pressure, and temperature. Various methods have been developed to determine the sound velocity through materials. Among them, a strategy based on ultrasound resonance frequency has been most widely used due to the simplicity. However, it requires a transducer with a wide bandwidth to cover enough resonance frequencies to perform the consequent calculations. In this paper, we develop a resonance method for measuring sound velocity, using multi-frequency narrow-band transducers breaking through the limitation of transducer bandwidth on the utilization of the resonance method. We use different transducers at different center frequencies and with different bandwidth to measure the sound velocity in 100-µm and 400-µm thick steel pieces. The measurement results of different combinations are in good agreement, verifying that the use of multi-frequency narrow-band transducer combinations. Given that most therapeutic transducers have a narrow bandwidth, this method can be used during intracranial ultrasound stimulation to optimize targeting by non-invasively measuring the sound velocity in the skull, especially at thinner locations.

8.
Micromachines (Basel) ; 14(1)2023 Jan 14.
Artigo em Inglês | MEDLINE | ID: mdl-36677274

RESUMO

Acoustic microscopes and acoustic tweezers have great value in the application of microparticle manipulation, biomedical research and non-destructive testing. Ultrahigh frequency (UHF) ultrasonic transducers act as the key component in acoustic microscopes, and acoustic tweezers and acoustic lenses are essential parts of UHF ultrasonic transducers. Therefore, the preparation of acoustic lenses is crucial. Silicon is a suitable material for preparing acoustic lenses because of its high acoustic velocity, low acoustic attenuation and excellent machinability. In previous research, silicon lenses were mainly prepared by etching. However, etching has some drawbacks. The etching of large sizes is complex, time-consuming and expensive. Furthermore, vertical etching is preferred to spherical etching. Thus, a new method of ultra-precision machining was introduced to prepare silicon lenses. In this paper, silicon lenses with an aperture of 892 µm and a depth of 252 µm were prepared. Then, UHF ultrasonic transducers with a center frequency of 157 MHz and a -6-dB bandwidth of 52% were successfully prepared based on silicon lenses. The focal distance of the transducers was 736 µm and the F-number was about 0.82. The transducers had a lateral resolution of 11 µm and could distinguish the 13 µm slots on silicon wafers clearly.

9.
Brain Stimul ; 15(5): 1308-1317, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36130679

RESUMO

Sonogenetics refers to the use of genetically encoded, ultrasound-responsive mediators for noninvasive and selective control of neural activity. It is a promising tool for studying neural circuits. However, due to its infancy, basic studies and developments are still underway, including gauging key in vivo performance metrics such as spatiotemporal resolution, selectivity, specificity, and safety. In this paper, we summarize recent findings on sonogenetics to highlight technical hurdles that have been cleared, challenges that remain, and future directions for optimization.


Assuntos
Encéfalo , Encéfalo/diagnóstico por imagem , Ultrassonografia
10.
Micromachines (Basel) ; 13(8)2022 Aug 02.
Artigo em Inglês | MEDLINE | ID: mdl-36014168

RESUMO

Lead-free environmentally friendly piezoelectrical materials with enhanced piezoelectric properties are of great significance for high-resolution ultrasound imaging applications. In this paper, Na0.5Bi4.5Ti3.86Mn0.06Nb0.08O15+y (NBT-Nb-Mn) bismuth-layer-structured ceramics were prepared by solid-phase synthesis. The crystallographic structure, micromorphology, and piezoelectrical and electromechanical properties of NBT-Nb-Mn ceramics were examined, showing their enhanced piezoelectricity (d33 = 33 pC/N) and relatively high electromechanical coupling coefficient (kt = 0.4). The purpose of this article is to describe the development of single element ultrasonic transducers based on these piezoelectric ceramics. The as-prepared high-frequency tightly focused transducer (ƒ-number = 1.13) had an electromechanical coupling coefficient of 0.48. The center frequency was determined to be 37.4 MHz and the -6 dB bandwidth to be 47.2%. According to the B-mode imaging experiment of 25 µm tungsten wires, lateral resolution of the transducer was calculated as 56 µm. Additionally, the experimental results were highly correlated to the results simulated by COMSOL software. By scanning a coin, the imaging effect of the transducer was further evaluated, demonstrating the application advantages of the prepared transducer in the field of high-sensitivity ultrasound imaging.

11.
Front Neurosci ; 16: 893108, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35801172

RESUMO

Transcranial ultrasound stimulation (TUS) is a young neuromodulation technology, which uses ultrasound to achieve non-invasive stimulation or inhibition of deep intracranial brain regions, with the advantages of non-invasive, deep penetration, and high resolution. It is widely considered to be one of the most promising techniques for probing brain function and treating brain diseases. In preclinical studies, developing miniaturized transducers to facilitate neuromodulation in freely moving small animals is critical for understanding the mechanism and exploring potential applications. In this article, a miniaturized transducer with a half-concave structure is proposed. Based on the finite element simulation models established by PZFlex software, several ultrasound transducers with different concave curvatures were designed and analyzed. Based on the simulation results, half-concave focused ultrasonic transducers with curvature radii of 5 mm and 7.5 mm were fabricated. Additionally, the emission acoustic fields of the ultrasonic transducers with different structures were characterized at their thickness resonance frequencies of 1 MHz using a multifunctional ultrasonic test platform built in the laboratory. To verify the practical ability for neuromodulation, different ultrasound transducers were used to induce muscle activity in mice. As a result, the stimulation success rates were (32 ± 10)%, (65 ± 8)%, and (84 ± 7)%, respectively, by using flat, #7, and #5 transducers, which shows the simulation and experimental results have a good agreement and that the miniaturized half-concave transducer could effectively converge the acoustic energy and achieve precise and effective ultrasonic neuromodulation.

12.
Artigo em Inglês | MEDLINE | ID: mdl-35320097

RESUMO

Ultrasonic imaging has become a very promising technology, and it has been widely applied in biomedicine, geology, and other fields due to its advantages of safety, nondamaging, and real time. Especially, the portable high-frequency (>20 MHz) ultrasonic imaging system (UIS) has been generally used in biomedical detection and diagnosis. In the complex actual environment, the effect of integrated circuits (ICs) on the performance of portable high-frequency UIS is obvious. In the echo signal transmission link, the analog front end (AFE) and the analog-to-digital converter (ADC) are the two most critical modules, where AFE is used to receive and preprocess the analog ultrasonic echo signals and ADC to convert the analog signals from the AFE output to digital. The structure and performance of the ICs integrated into terminal equipment and in-probe for the portable high-frequency UIS are introduced and discussed. Some typical commercial ICs are also summarized. Based on the requirements and challenges of portable high-frequency UIS, the future development directions of ICs mainly include high integration, ultralow power consumption, high speed, and high precision, which can provide valuable reference and advice for the design of AFE and ADC for portable high-frequency UIS.


Assuntos
Processamento de Sinais Assistido por Computador , Ultrassom , Desenho de Equipamento , Ultrassonografia
13.
Micromachines (Basel) ; 13(2)2022 Jan 25.
Artigo em Inglês | MEDLINE | ID: mdl-35208301

RESUMO

Acoustic tweezers for microparticle non-contact manipulation have attracted attention in the biomedical engineering field. The key components of acoustic tweezers are piezoelectric materials, which convert electrical energy to mechanical energy. The most widely used piezoelectric materials are lead-based materials. Because of the requirement of environmental protection, lead-free piezoelectric materials have been widely researched in past years. In our previous work, textured lead-free (K, Na)NbO3 (KNN)-based piezoelectric ceramics with high piezoelectric performance were prepared. In addition, the acoustic impedance of the KNN-based ceramics is lower than that of lead-based materials. The low acoustic impedance could improve the transmission efficiency of the mechanical energy between acoustic tweezers and water. In this work, acoustic tweezers were prepared to fill the gap between lead-free piezoelectric materials research and applications. The tweezers achieved 13 MHz center frequency and 89% -6 dB bandwidth. The -6 dB lateral and axial resolution of the tweezers were 195 µm and 114 µm, respectively. Furthermore, the map of acoustic pressure measurement and acoustic radiation calculation for the tweezers supported the trapping behavior for 100 µm diameter polystyrene microspheres. Moreover, the trapping and manipulation of the microspheres was achieved. These results suggest that the KNN-based acoustic tweezers have a great potential for further applications.

14.
Micromachines (Basel) ; 13(1)2022 Jan 11.
Artigo em Inglês | MEDLINE | ID: mdl-35056279

RESUMO

As traditional ultrasonic imaging systems (UIS) are expensive, bulky, and power-consuming, miniaturized and portable UIS have been developed and widely utilized in the biomedical field. The performance of integrated circuits (ICs) in portable UIS obviously affects the effectiveness and quality of ultrasonic imaging. In the ICs for UIS, the analog-to-digital converter (ADC) is used to complete the conversion of the analog echo signal received by the analog front end into digital for further processing by a digital signal processing (DSP) or microcontroller unit (MCU). The accuracy and speed of the ADC determine the precision and efficiency of UIS. Therefore, it is necessary to systematically review and summarize the characteristics of different types of ADCs for UIS, which can provide valuable guidance to design and fabricate high-performance ADC for miniaturized high resolution UIS. In this paper, the architecture and performance of ADC for UIS, including successive approximation register (SAR) ADC, sigma-delta (Σ-∆) ADC, pipelined ADC, and hybrid ADC, have been systematically introduced. In addition, comparisons and discussions of different types of ADCs are presented. Finally, this paper is summarized, and presents the challenges and prospects of ADC ICs for miniaturized high resolution UIS.

15.
Artigo em Inglês | MEDLINE | ID: mdl-35020592

RESUMO

The high-frequency ultrasonic transducers with larger bandwidths yield excellent imaging performance in the biomedical field. However, achieving perfect acoustic impedance matching from the piezo-element to the target medium in the operating frequency spectrum is still a challenge. Conventional matching layers are mostly fabricated by only one or two uniform materials which are limited by their acoustic property. We propose a novel composite matching layer with gradient acoustic impedance based on a 1-3 gradient composite structure and multilevel matching theory. The proposed gradient-composite matching layer applied for ultrasonic transducer provides efficient impedance matching and ultrawide bandwidth which can significantly improve the quality of biomedical imaging. The active aperture size of the matching layer is 5× 5 mm2, and the overall thickness for five equivalent layers is 115 [Formula: see text]. The -6-dB bandwidth and the center frequency obtained by the ultrasonic transducer equipped with the 1-3 gradient composite matching layer are 141.7% and 22.3 MHz, respectively. The exceedingly good imaging performance of the fabricated ultrasonic transducer was demonstrated by the tungsten wire phantom and study on the biological tissues of a zebrafish and porcine eyeball. The theoretical and experimental results provide a novel train of thought for improving the quality of biomedical ultrasonic imaging.


Assuntos
Ultrassom , Peixe-Zebra , Acústica , Animais , Impedância Elétrica , Desenho de Equipamento , Suínos , Transdutores , Ultrassonografia/métodos
16.
Artigo em Inglês | MEDLINE | ID: mdl-34469292

RESUMO

The control of acoustic field has great potential in many applications such as medical treatment, neuro-modulation, and bio-imaging. Recently, acoustic lenses and phased arrays have become common ways of controlling acoustic fields. However, the shortcomings of the two ways are obvious. Acoustic lenses lack flexibility after design, and phased arrays have complicated structures and need to adjust the parameters of each array element. In this work, we propose an alternative for sound field control using a flexible and adjustable "acoustic projector," and two symmetric mirrors are used to change the direction of propagation of an acoustic wave produced by a piezoelectric element and realize acoustic focusing in the target region. The 2-D "acoustic projector" model was built in finite element simulation, and the feasibility was verified with an actual prototype. The sound intensity produced by the piezoelectric element at different horizontal and vertical positions along the target area can be accurately controlled by two adjustable mirrors. When the angle of the mirror ranges from 30° to 40°, the focal depth can change from 39 to 140 mm. Furthermore, the focus can be controlled in a sector with an angle of 60°. The "acoustic projector" demonstrates simple but precise control of acoustic fields and may broaden their applicability. To show its imaging ability, the three groups of target balls at different positions were imaged and their position information by scanning the mirrors in simulation was given.


Assuntos
Lentes , Ultrassom , Acústica , Transdutores , Ultrassonografia
17.
Artigo em Inglês | MEDLINE | ID: mdl-34847024

RESUMO

This study investigates the relationship between the composition segregation in lead magnesium niobate-lead titanate (PMN-PT; PMN-29%PT, PMN-29.5%PT, PMN-30%PT, PMN-30.5%PT, and PMN-31%PT) single crystals within morphotropic phase boundary (MPB) and the corresponding ultrasonic transducer performance through PiezoCAD modeling and real transducer testing. For five crystals with compositions distributed across the main body of a crystal ingot, the piezoelectric coefficient and free relative permittivity values were measured to vary by over 30%, whereas the transducer bandwidth and center frequency values were modeled to change by less than 10%. For the single-element ultrasonic transducers fabricated using those crystals without matching layers, the variations of -6-dB bandwidth, insertion loss, receiver-free field voltage response, and center frequency were measured to be 9.61%, -15.23%, 9.76%, and 1.41%, respectively, confirming the modeling results. Using the Mason and Krimholtz, Leedom, and Matthaei (KLM) models, it is found that the relatively stable transducer performance can be attributed to the relatively consistent electromechanical coupling coefficient, acoustic impedance, and clamped relative permittivity originated from the stable elastic compliance properties among the crystals of various compositions. It is expected that the relatively stable performance could be extended to multielement transducers with matching layers for the same contributing mechanisms. Our results suggest that it is possible to use crystal plates of different compositions within the MPB region, obtained from one and the same ingot, to fabricate a batch of ultrasonic transducers that will exhibit a similar performance, significantly reducing the cost of materials.


Assuntos
Transdutores , Ultrassom , Desenho de Equipamento
18.
Artigo em Inglês | MEDLINE | ID: mdl-34705642

RESUMO

( 1- x )BiScO3- x PbTiO3 (BS-PT) ceramics have excellent piezoelectricity and high Curie temperature at its morphotropic phase boundary (MPB) ( x = 0.64 ), so it is a promising piezoelectric material for fabricating high-temperature ultrasonic transducer (HTUT). Electric properties of 0.36BS-0.64PT ceramics were characterized at different temperatures, and an HTUT with the center frequency of about 15 MHz was designed by PiezoCAD based on the measuring results. The prepared HTUT was tested in a silicone oil bath at different temperatures systematically. The test results show that the HTUT can maintain a stable electrical resonance until 290 °C and get a clear echo response until 250 °C with slight changes of the center frequency. Then, a stepped metal block submerged in silicone oil was imaged by the HTUT until 250 °C. Velocity of silicone oil and axial resolution of the HTUT at different temperatures was calculated. The results verify the capability of 0.36BS-0.64PT-based HTUT for high-temperature ultrasonic imaging applications.


Assuntos
Transdutores , Ultrassom , Desenho de Equipamento , Análise de Falha de Equipamento , Temperatura
19.
IEEE Trans Biomed Eng ; 69(1): 475-481, 2022 01.
Artigo em Inglês | MEDLINE | ID: mdl-34288870

RESUMO

Ultrasonic transducers with broad bandwidth are considered to have high axial resolution and good ultrasound scanning flexibility for the clinical applications. The limitations of spatial resolution due to bandwidth are of great concern in ultrasound medical imaging. The method of acoustic impedance matching between the piezoelectric element and medium is commonly used to obtain broad bandwidth and high resolution. In this study, an optimized backing layer design was proposed to broaden the bandwidth by adding a tunable acoustic impedance matching layer of backing (AIMLB) between the backing layer and the piezoelectric ceramic element. The Mason equivalent circuit method was used to analyze the effect of the backing material composition and its structure on the bandwidth of the transducer. The optimized transducer was simulated using the finite-element method with the PZFlex software. Based on the PZFlex simulations, a 20-MHz ultrasonic transducer using the AIMLB with a bandwidth of approximately 92.29% was fabricated. The experimental results were in good agreement with the simulations. The ultrasonic imaging indicated that the designed ultrasonic transducer with an additional AIMLB had high performance with good imaging capability.


Assuntos
Transdutores , Ultrassom , Cerâmica , Desenho de Equipamento , Ultrassonografia
20.
Artigo em Inglês | MEDLINE | ID: mdl-34928795

RESUMO

In vivo imaging of skin is commonly used to investigate dynamic processes in the progression and treatment of psoriasis. Photoacoustic mesoscopy is a new non-invasive imaging modality widely used in bio-imaging, and has recently been applied to imaging skin in vivo. However, photoacoustic imaging has shortcomings. Although high-frequency ultrasonic transducers enable high-resolution photoacoustic imaging, the images may be bandwidth-limited. To overcome this limitation, we designed and fabricated a broadband ultrasonic transducer for photoacoustic mesoscopy. The center frequency of the transducer was 32 MHz (88% bandwidth at -6 dB). The transducer was used to visualize mouse and human skin morphology. Colocalization of high- and low-frequency components revealed information about both the skin surface and dermis. To explore dynamic structural changes in mouse back skin during psoriasis progression, we measured blood oxygen saturation and total hemoglobin in a mouse model using multiwavelength imaging without contrast agents. The results indicate that functional photoacoustic mesoscopy using a broadband high-frequency transducer has great potential for clinical imaging of skin disease.


Assuntos
Técnicas Fotoacústicas , Psoríase , Animais , Camundongos , Técnicas Fotoacústicas/métodos , Psoríase/diagnóstico por imagem , Pele , Transdutores , Ultrassom
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA