Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 11 de 11
Filtrar
1.
AJR Am J Roentgenol ; 218(6): 931-939, 2022 06.
Artigo em Inglês | MEDLINE | ID: mdl-35107311

RESUMO

Midgut volvulus in association with malrotation is a pediatric surgical emergency. Prompt and accurate diagnosis is necessary to avoid bowel ischemia and necrosis, thereby reducing morbidity and mortality. Historically, the fluoroscopic upper gastrointestinal series has been the preferred imaging modality for the evaluation of both midgut malrotation and volvulus, although the use of ultrasound (US) is increasing. In this Narrative Review, we describe the findings of midgut malrotation and volvulus on US, including practical tips for acquisition and interpretation; discuss the advantages and challenges of both imaging modalities; and propose a path and safeguards for possible transition to the use of US as the first-line modality for diagnosis based on our experience in imaging children with midgut malrotation and volvulus.


Assuntos
Anormalidades do Sistema Digestório , Volvo Intestinal , Criança , Diagnóstico por Imagem , Anormalidades do Sistema Digestório/diagnóstico por imagem , Anormalidades do Sistema Digestório/cirurgia , Humanos , Volvo Intestinal/diagnóstico por imagem , Ultrassonografia/métodos
2.
Med Phys ; 48(9): 4944-4954, 2021 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-34255871

RESUMO

PURPOSE: Inkjet printers can be used to fabricate anthropomorphic phantoms by the use of iodine-doped ink. However, challenges persist in implementing this technique. The calibration from grayscale to ink density is complex and time-consuming. The purpose of this work is to develop a printing methodology that requires a simpler calibration and is less dependent on printer characteristics to produce the desired range of x-ray attenuation values. METHODS: Conventional grayscale printing was substituted by single-tone printing; that is, the superposition of pure black layers of iodinated ink. Printing was performed with a consumer-grade inkjet printer using ink made of potassium-iodide (KI) dissolved in water at 1 g/ml. A calibration for the attenuation of ink was measured using a commercial x-ray system at 70 kVp. A neonate radiograph obtained at 70 kVp served as an anatomical model. The attenuation map of the neonate radiograph was processed into a series of single-tone images. Single-tone images were printed, stacked, and imaged at 70 kVp. The phantom was evaluated by comparing attenuation values between the printed phantom and the original radiograph; attenuation maps were compared using the structural similarity index measure (SSIM), while attenuation histograms were compared using the Kullback-Leibler (KL) divergence. A region of interest (ROI)-based analysis was also performed, where the attenuation distribution within given ROIs was compared between phantom and patient. The phantom sharpness was evaluated in terms of modulation transfer function (MTF) estimates and signal spread profiles of high spatial resolution features in the image. RESULTS: The printed phantom required 36 pages. The printing queue was automated and it took about 2 h to print the phantom. The radiograph of the printed phantom demonstrated a close resemblance to the original neonate radiograph. The SSIM of the phantom with respect to that of the patient was 0.53. Both patient and phantom attenuation histograms followed similar distributions, and the KL divergence between such histograms was 0.20. The ROI-based analysis showed that the largest deviations from patient attenuation values were observed at the higher and lower ends of the attenuation range. The limiting resolution of the proposed methodology was about 1 mm. CONCLUSION: A methodology to generate a neonate phantom for 2D imaging applications, using single-tone printing, was developed. This method only requires a single-value calibration and required less than 2 h to print a complete phantom.


Assuntos
Modelos Anatômicos , Impressão Tridimensional , Calibragem , Humanos , Recém-Nascido , Imagens de Fantasmas , Radiografia , Raios X
3.
J Pediatr Surg ; 54(1): 184-188, 2019 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-30414689

RESUMO

BACKGROUND/PURPOSE: We examined outcomes before and after implementing an enteral water-soluble contrast protocol for management of pediatric adhesive small bowel obstruction (ASBO). METHODS: Medical records were reviewed retrospectively for all children admitted with ASBO between November 2010 and June 2017. Those admitted between November 2010 and October 2013 received nasogastric decompression with decision for surgery determined by surgeon judgment (preprotocol). Patients admitted after October 2013 (postprotocol) received water-soluble contrast early after admission, were monitored with serial examinations and radiographs, and underwent surgery if contrast was not visualized in the cecum by 24 h. Group outcomes were compared. RESULTS: Twenty-six patients experienced 29 admissions preprotocol, and 11 patients experienced 12 admissions postprotocol. Thirteen (45%) patients admitted preprotocol underwent surgery, versus 2 (17%) postprotocol patients (p = 0.04). Contrast study diagnostic sensitivity as a predictor for ASBO resolution was 100%, with 90% specificity. Median overall hospital LOS trended shorter in the postprotocol group, though was not statistically significant (6.2 days (preprotocol) vs 3.6 days (postprotocol) p = 0.12). Pre- vs. postprotocol net operating cost per admission yielded a savings of $8885.42. CONCLUSIONS: Administration of water-soluble contrast after hospitalization for pediatric ASBO may play a dual diagnostic and therapeutic role in management with decreases in surgical intervention, LOS, and cost. TYPE OF STUDY: Retrospective comparative study. LEVEL OF EVIDENCE: Level III.


Assuntos
Meios de Contraste/uso terapêutico , Diatrizoato de Meglumina/uso terapêutico , Obstrução Intestinal/terapia , Aderências Teciduais/terapia , Adolescente , Criança , Pré-Escolar , Meios de Contraste/economia , Diatrizoato de Meglumina/economia , Feminino , Custos de Cuidados de Saúde/estatística & dados numéricos , Hospitalização , Humanos , Lactente , Obstrução Intestinal/diagnóstico por imagem , Intestino Delgado/diagnóstico por imagem , Intestino Delgado/efeitos dos fármacos , Intestino Delgado/patologia , Tempo de Internação/estatística & dados numéricos , Masculino , Estudos Retrospectivos , Aderências Teciduais/complicações , Aderências Teciduais/diagnóstico por imagem , Adulto Jovem
4.
Pediatr Radiol ; 48(2): 210-215, 2018 02.
Artigo em Inglês | MEDLINE | ID: mdl-29130139

RESUMO

BACKGROUND: Default pediatric protocols on many digital radiography systems are configured based on patient age. However, age does not adequately characterize patient size, which is the principal determinant of proper imaging technique. Use of default pediatric protocols by inexperienced technologists can result in patient overexposure, inadequate image quality, or repeated examinations. OBJECTIVE: To ensure diagnostic image quality at a well-managed patient radiation exposure by transitioning to thickness-based protocols for pediatric portable abdomen radiography. MATERIALS AND METHODS: We aggregated patient thickness data, milliamperes (mAs), kilovoltage peak (kVp), exposure index (EI), source-to-detector distance, and grid use for all portable abdomen radiographs performed in our pediatric hospital in a database with a combination of automated and manual data collection techniques. We then analyzed the database and used it as the basis to construct thickness-based protocols with consistent image quality across varying patient thicknesses, as determined by the EI. RESULTS: Retrospective analysis of pediatric portable exams performed at our adult-focused hospitals demonstrated substantial variability in EI relative to our pediatric hospital. Data collection at our pediatric hospital over 4 months accumulated roughly 800 portable abdomen exams, which we used to develop a thickness-based technique chart. CONCLUSION: Through automated retrieval of data in our systems' digital radiography exposure logs and recording of patient abdomen thickness, we successfully developed thickness-based techniques for portable abdomen radiography.


Assuntos
Abdome/anatomia & histologia , Abdome/diagnóstico por imagem , Sistemas Automatizados de Assistência Junto ao Leito , Radiografia Abdominal/instrumentação , Criança , Protocolos Clínicos , Feminino , Humanos , Masculino , Melhoria de Qualidade , Estudos Retrospectivos
5.
Pediatr Radiol ; 46(1): 112-8, 2016 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-26335424

RESUMO

BACKGROUND: There has been increasing interest in patient dose reduction in neonatal intensive care units. Removing comfort pads for radiography has been identified as a potential means to decrease patient dose. OBJECTIVE: To assess the effect of comfort pads and support trays on detector entrance exposure (DEE) and image quality for neonatal radiography, and its implication for patient dose. MATERIALS AND METHODS: Comfort pads and support trays from three incubator and warmer systems were examined. The attenuation of the primary beam by these structures was measured using a narrow beam geometry. Their effect on DEE and image quality was then assessed using typical neonatal chest radiography techniques with three configurations: 1) both the comfort pad and support included in the beam, 2) only the support tray included and 3) both the comfort pad and support tray removed. RESULTS: Comfort pads and support trays were found to attenuate the primary beam by 6-15%. Eliminating these structures from the X-ray beam's path was found to increase the detector entrance exposure by 28-36% and increase contrast-to-noise ratio by more than 21%, suggesting room for patient dose reduction when the same image quality is maintained. CONCLUSION: Comfort pads and tray support devices can have a considerable effect on DEE and image quality, with large variations among different incubator designs. Positioning the image detector directly underneath neonatal patients for radiography is a potential means for patient dose reduction. However, such benefit should be weighed against the risks of moving the patient.


Assuntos
Roupas de Cama, Mesa e Banho , Incubadoras para Lactentes , Exposição à Radiação/análise , Exposição à Radiação/prevenção & controle , Proteção Radiológica/instrumentação , Tomografia Computadorizada por Raios X/instrumentação , Desenho de Equipamento , Análise de Falha de Equipamento , Feminino , Humanos , Recém-Nascido , Masculino , Posicionamento do Paciente/instrumentação , Doses de Radiação , Proteção Radiológica/métodos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Tomografia Computadorizada por Raios X/métodos
6.
Pediatr Blood Cancer ; 60(3): 512-4, 2013 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-23129137

RESUMO

Outcome for the vast majority of high-risk neuroblastoma patients with refractory or relapsed disease is dismal. We report two high-risk patients who remain progression-free for more than 113 and 18 months following the diagnosis of refractory/relapsed disease who were treated with surgery alone. Complete resolution of a refractory thoracic mass and relapsed liver nodules was observed in one patient. The refractory/relapsed disease in the second patient has remained stable. In both cases, the tumor showed histologic evidence of neuroblastoma maturation. These cases demonstrate that refractory/relapsed neuroblastoma is clinically heterogeneous and highlight the need for better biomarkers to optimize patient care.


Assuntos
Recidiva Local de Neoplasia/mortalidade , Recidiva Local de Neoplasia/cirurgia , Neuroblastoma/mortalidade , Neuroblastoma/cirurgia , Protocolos de Quimioterapia Combinada Antineoplásica/uso terapêutico , Pré-Escolar , Terapia Combinada , Intervalo Livre de Doença , Feminino , Humanos , Lactente , Transplante de Células-Tronco
7.
J Clin Ultrasound ; 38(8): 409-19, 2010 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-20872936

RESUMO

PURPOSE: To evaluate reader variability of white matter lesions seen on cranial sonographic scans of extreme low gestational age neonates (ELGANs). METHODS: In 1,452 ELGANs, cranial sonographic scans were obtained in the first and second postnatal weeks, and between the third postnatal week and term. All sets of scans were read independently by two sonologists. We reviewed the use of four diagnostic labels: early periventricular leucomalacia, cystic periventricular leucomalacia, periventricular hemorrhagic infarction (PVHI), and other white matter diagnosis, by 16 sonologists at 14 institutions. We evaluated the association of these labels with location and laterality of hyperechoic and hypoechoic lesions, location of intraventricular hemorrhage, and characteristics of ventricular enlargement. RESULTS: Experienced sonologists differed substantially in their application of the diagnostic labels. Three readers applied early periventricular leucomalacia to more than one fourth of all the scans they read, whereas eight applied this label to ≤5% of scans. Five applied PVHI to ≥10% of scans, while three applied this label to ≤5% of scans. More than one third of scans labeled cystic periventricular leucomalacia had unilateral hypoechoic lesions. White matter abnormalities in PVHI were more extensive than in periventricular leucomalacia and were more anteriorly located. Hypoechoic lesions on late scans tended to be in the same locations, regardless of the diagnostic label applied. CONCLUSIONS: Experienced sonologists differ considerably in their tendency to apply diagnostic labels for white matter lesions. This is due to lack of universally agreed-upon definitions. We recommend reducing this variability to improve the validity of large multicenter studies.


Assuntos
Encéfalo/patologia , Ecoencefalografia/normas , Doenças do Prematuro/diagnóstico por imagem , Variações Dependentes do Observador , Ultrassonografia Pré-Natal/normas , Diagnóstico Diferencial , Ecoencefalografia/estatística & dados numéricos , Humanos , Recém-Nascido , Recém-Nascido Prematuro
9.
Eur Urol ; 53(1): 198-200, 2008 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-17292531

RESUMO

Large cystic abdominal masses can represent a diagnostic dilemma despite advanced diagnostic and imaging techniques. We report a case of a large cystic mass initially managed as a giant ureteropelvic junction obstruction, but ultimately found to be a congenital splenic cyst. Focus is placed on the diagnostic evaluation of large cystic abdominal masses.


Assuntos
Cisto Epidérmico/diagnóstico , Hidronefrose/diagnóstico , Esplenopatias/diagnóstico , Adolescente , Diagnóstico Diferencial , Cisto Epidérmico/cirurgia , Feminino , Humanos , Laparoscopia/métodos , Imageamento por Ressonância Magnética , Nefrostomia Percutânea/métodos , Esplenopatias/cirurgia , Urografia
10.
Pediatr Radiol ; 37(12): 1201-8, 2007 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-17901950

RESUMO

BACKGROUND: Neurosonography can assist clinicians and can provide researchers with documentation of brain lesions. Unfortunately, we know little about the reliability of sonographically derived diagnoses. OBJECTIVE: We sought to evaluate observer variability among experienced neurosonologists. MATERIALS AND METHODS: We collected all protocol US scans of 1,450 infants born before the 28th postmenstrual week. Each set of scans was read by two independent sonologists for the presence of intraventricular hemorrhage (IVH) and moderate/severe ventriculomegaly, as well as hyperechoic and hypoechoic lesions in the cerebral white matter. Scans read discordantly for any of these four characteristics were sent to a tie-breaking third sonologist. RESULTS: Ventriculomegaly, hypoechoic lesions and IVH had similar rates of positive agreement (68-76%), negative agreement (92-97%), and kappa values (0.62 to 0.68). Hyperechoic lesions, however, had considerably lower values of positive agreement (48%), negative agreement (84%), and kappa (0.32). No sonologist identified all abnormalities more or less often than his/her peers. Approximately 40% of the time, the tie-breaking reader agreed with the reader who identified IVH, ventriculomegaly, or a hypoechoic lesion in the white matter. Only about 25% of the time did the third party agree with the reader who reported a white matter hyperechoic lesion. CONCLUSION: Obtaining concordance seems to be an acceptable way to assure reasonably high-quality of images needed for clinical research.


Assuntos
Encéfalo/anormalidades , Ecoencefalografia , Doenças do Prematuro/diagnóstico por imagem , Hemorragias Intracranianas/diagnóstico por imagem , Ventrículos Cerebrais/anormalidades , Ventrículos Cerebrais/diagnóstico por imagem , Competência Clínica , Feminino , Humanos , Recém-Nascido , Masculino , Variações Dependentes do Observador , Valor Preditivo dos Testes
11.
Urology ; 67(5): 1085.e9-11, 2006 May.
Artigo em Inglês | MEDLINE | ID: mdl-16698386

RESUMO

Congenital posterior urethral polyps are rare, benign lesions of the posterior urethra. We report a 1-day-old newborn boy with a solitary fibroepithelial posterior urethral polyp who presented with a history of prenatal mild hydronephrosis, subsequently associated with bladder wall thickening on ultrasonography.


Assuntos
Hidronefrose/diagnóstico por imagem , Pólipos/diagnóstico , Doenças Uretrais/diagnóstico , Obstrução Uretral/etiologia , Cistoscopia , Técnicas de Diagnóstico Urológico , Humanos , Hidronefrose/etiologia , Recém-Nascido , Masculino , Pólipos/complicações , Ultrassonografia Pré-Natal , Doenças Uretrais/complicações
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA