Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 9 de 9
Filtrar
2.
Front Cardiovasc Med ; 10: 1256112, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-38028449

RESUMO

Introduction: Previous analyses have reported the outcomes of transcatheter aortic valve replacement (TAVR) for patients with low-flow, low-gradient (LFLG) aortic stenosis (AS), without stratifying according to the route of access. Differences in mortality rates among access routes have been established for high-gradient (HG) patients and hypothesized to be even more pronounced in LFLG AS patients. This study aims to compare the outcomes of patients with LFLG or HG AS following transfemoral (TF) or transapical (TA) TAVR. Methods: A total of 910 patients, who underwent either TF or TA TAVR with a median follow-up of 2.22 (IQR: 1.22-4.03) years, were included in this multicenter cohort study. In total, 146 patients (16.04%) suffered from LFLG AS. The patients with HG and LFLG AS were stratified according to the route of access and compared statistically. Results: The operative mortality rates of patients with HG and LFLG were found to be comparable following TF access. The operative mortality rate was significantly increased for patients who underwent TA access [odds ratio (OR): 2.91 (1.54-5.48), p = 0.001] and patients with LFLG AS [OR: 2.27 (1.13-4.56), p = 0.02], which could be corroborated in a propensity score-matched subanalysis. The observed increase in the risk of operative mortality demonstrated an additive effect [OR for TA LFLG: 5.45 (2.35-12.62), p < 0.001]. LFLG patients who underwent TA access had significantly higher operative mortality rates (17.78%) compared with TF LFLG (3.96%, p = 0.016) and TA HG patients (6.36%, p = 0.024). Conclusions: HG patients experienced a twofold increase in operative mortality rates following TA compared with TF access, while LFLG patients had a fivefold increase in operative mortality rates. TA TAVR appears suboptimal for patients with LFLG AS. Prospective studies should be conducted to evaluate alternative options in cases where TF is not possible.

3.
Front Cardiovasc Med ; 10: 1185518, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37265566

RESUMO

Introduction: The extent of the hemodynamic benefit from AV-synchronous pacing in patients with sinus rhythm and AV block is not completely understood. Thus, we systematically investigated the association of an array of echocardiographic and epidemiological parameters with the change in cardiac output depending on the stimulation mode (AV-synchronous or AV-asynchronous pacing). Methods: Patients in sinus rhythm after previous dual chamber pacemaker implantation underwent a thorough basic echocardiographic assessment of diastolic and systolic left ventricular function, and atrial function (26 echo parameters, including novel speckle tracking strain measurements). Then, stroke volume was measured with AV-synchronous (DDD) and AV-asynchronous (VVI) pacing. Each patient represented their own control, and the sequence of stroke volume measurements was randomized. Results: In this prospective single-center study (NCT04068233, registration August 22nd 2019), we recruited 40 individuals. The stroke volume was higher in all patients when applying AV-synchronous DDD pacing [median increase 12.8 ml (16.9%), P < 0.001]. No echo parameter under investigation was associated with the extent of stroke volume increase in a linear regression model. Of all epidemiological variables, a history of acute myocardial infarction (AMI) was associated with an attenuated stroke volume gain in a univariate and a multivariate regression model that adjusted for confounders. A- and S-wave velocities were reduced in the AMI group. Discussion: In our cohort of patients, each subject benefited from AV-synchronous DDD pacing. No single echo parameter could predict the amount of stroke volume increase. The beneficial effect of AV-synchronous pacing on stroke volume was attenuated after prior acute myocardial infarction.ClinicalTrials.gov identifier (NCT number): NCT04068233.

4.
JACC Cardiovasc Interv ; 14(24): 2723-2732, 2021 12 27.
Artigo em Inglês | MEDLINE | ID: mdl-34949397

RESUMO

OBJECTIVES: The aims of this study were to evaluate the rate and time course of delayed total atrioventricular block (DT-AVB) after transcatheter aortic valve replacement (TAVR) using continuous electrocardiographic monitoring by implantable loop recorders and to identify potential predictors. BACKGROUND: DT-AVB has been defined as onset more than 2 days after TAVR or after hospital discharge and is reported in 10% to 15% of patients at 30-day follow-up. To date, there is no standardized diagnostic and therapeutic algorithm to manage TAVR patients at risk for DT-AVB. METHODS: Consecutive patients undergoing TAVR and simultaneous electrophysiologic testing without persistent or recurrent total atrioventricular block within 48 hours after the procedure underwent loop recorder implantation for full disclosure of atrioventricular conduction during 12-month follow-up. RESULTS: DT-AVB occurred in 7 of 59 patients (11.9%), with onset between 2 days and 3 months after the procedure. Both prolongation of the PQ interval between baseline and day 2 after TAVR (OR: 1.04; 95% CI: 1.01-1.09); P = 0.032) and prolongation of the HV interval during the procedure (OR: 1.07; 95% CI: 1.02-1.14; P = 0.015) significantly predicted the onset of DT-AVB. CONCLUSIONS: TAVR was associated with a considerable rate of DT-AVB of nearly 12% in this series. Prolongation of the PQ interval between baseline and day 2 and intraprocedural prolongation of the HV interval were significant predictors of DT-AVB.


Assuntos
Estenose da Valva Aórtica , Bloqueio Atrioventricular , Substituição da Valva Aórtica Transcateter , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/etiologia , Estenose da Valva Aórtica/cirurgia , Bloqueio Atrioventricular/diagnóstico , Bloqueio Atrioventricular/etiologia , Bloqueio Atrioventricular/terapia , Eletrocardiografia , Humanos , Fatores de Risco , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento
5.
Clin Chem Lab Med ; 2021 Oct 19.
Artigo em Inglês | MEDLINE | ID: mdl-34664479

RESUMO

Biomarkers, such as troponin-T and troponin-I, are regarded as the gold standard laboratory parameter for diagnosing many cardiological diseases. These parameters have been approved for clinical use. Many cardiological guidelines recommend the analysis of troponins in the majority of cardiological disease diagnoses and to also gain prognostic information. Nonetheless, many medical circumstances could cause false troponin elevations. In this article, we focus on troponin artifacts, particularly macro-immune complex formation, as important interference factors. Therefore, we performed a literature search from 2006 to 06/2021.

6.
Heart Rhythm ; 18(3): 419-425, 2021 03.
Artigo em Inglês | MEDLINE | ID: mdl-33250391

RESUMO

BACKGROUND: Transcatheter aortic valve implantation (TAVI) is an established treatment for patients with severe aortic stenosis and high to intermediate surgical risk. However, the proximity of the conduction system to the prosthesis landing zone bears the risk of atrioventricular conduction disorders. The underlying pathophysiology is not fully understood. OBJECTIVE: The purpose of this study was to characterize the impact of TAVI on the conduction system as assessed by simultaneous electrophysiological testing. METHODS: AH and HV intervals and QRS duration were measured using a quadripolar His catheter and surface electrocardiogram in 108 patients at baseline (BL), after balloon predilation (timepoint 1 [T1]), after implantation of the valve prosthesis (T2), and after postdilation, if deemed necessary (T3). RESULTS: Between BL and T2, significant increases of HV interval and QRS duration were observed, with a mean delta of +12.4 ms and +32.7 ms, respectively. Both balloon predilation and valve implantation had an impact on infranodal conduction. No significant increase of AH intervals was documented. The increase of QRS duration led to left bundle branch block (LBBB) in 57 patients (52.8%). Implantation depth positively correlated with QRS prolongation (ρ = 0.21, P = .042) but not with changes of AH or HV interval (ρ = -0.03, P = .762; and ρ = 0.15, P = .130, respectively). CONCLUSION: Electrophysiological testing during TAVI shows impairment of infranodal atrioventricular conduction by balloon predilation and valve implantation. This impairment is positively correlated with valve implantation depth and results in an increase of QRS duration with mainly LBBB pattern on surface electrocardiogram.


Assuntos
Estenose da Valva Aórtica/cirurgia , Arritmias Cardíacas/diagnóstico , Eletrocardiografia , Sistema de Condução Cardíaco/fisiopatologia , Frequência Cardíaca/fisiologia , Monitorização Intraoperatória/métodos , Substituição da Valva Aórtica Transcateter/métodos , Idoso de 80 Anos ou mais , Estenose da Valva Aórtica/complicações , Estenose da Valva Aórtica/fisiopatologia , Arritmias Cardíacas/complicações , Arritmias Cardíacas/fisiopatologia , Fenômenos Eletrofisiológicos , Feminino , Seguimentos , Humanos , Masculino , Projetos Piloto , Estudos Prospectivos
7.
Am J Cardiol ; 140: 69-77, 2021 02 01.
Artigo em Inglês | MEDLINE | ID: mdl-33152317

RESUMO

Patients with symptomatic, drug-refractory atrial fibrillation (AF) are frequently treated with catheter ablation. Cryo-ablation has been established as an alternative to radiofrequency ablation but long-term outcome data are still limited. This study aimed at elucidating the influence of the left atrial volume index (LAVI), derived from cardiac computed tomography (cCT) data, on the long-term outcome of ablation-naïve AF patients, after their first cryo-ablation. 415 patients (n = 290 [69.90%] male, 60.00 [IQR: 53.00 to 68.00] years old) who underwent a cCT and subsequent cryo-ablation index procedure were included in this single centre retrospective data analysis. A composite end point was defined (AF on electrocardiogram and/or electric cardioversion and/or re-do). Patients were closely followed for a year and then contacted for long-term follow-up after a median of 53.00 months (IQR: 34.50 to 73.00). Statistical analyses of the outcome and predictors of AF recurrence were conducted. In 224 patients (53.98%) no evidence of AF recurrence could be found. LAVI differed significantly between the positive and adverse (AF recurrence) outcome group (49.96 vs 56.07 ml/m2, p < 0.001). Cox regression analyses revealed cCT LAVI (HR: 1.022, 95% CI: 1.013 to 1.031, p < 0.001), BMI (HR: 1.044, 95% CI: 1.005 to 1.084, p < 0.05) and the type of AF (HR: 1.838 for nonparoxysmal AF, 95% CI: 1.214 to 2.781, p < 0.01) to be effective predictors of AF recurrence. A prognostic cCT LAVI cut-off value of 51.99 ml/m2 was calculated and must be validated in future prospective studies. In conclusion, LAVI is an accurate, yet underutilized predictor of AF recurrence after pulmonary vein isolation with cryo-energy and scores for calculating AF recurrence or progression risks might underemphasize the importance of CT-derived LAVI as a predictive factor.


Assuntos
Fibrilação Atrial/diagnóstico , Função do Átrio Direito/fisiologia , Criocirurgia/métodos , Eletrocardiografia , Átrios do Coração/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Idoso , Fibrilação Atrial/fisiopatologia , Fibrilação Atrial/cirurgia , Volume Cardíaco , Feminino , Seguimentos , Átrios do Coração/fisiopatologia , Humanos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Estudos Retrospectivos , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento
8.
J Thromb Thrombolysis ; 50(2): 380-385, 2020 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-32215782

RESUMO

D-Dimer has a high sensitivity but a low specificity for the diagnosis of deep vein thrombosis (DVT) which limits its implementation as a general screening parameter. There is a demand for additional biomarkers to improve its diagnostic accuracy. Soluble platelet endothelial cell adhesion molecule 1 (sPECAM-1) is generated at the site of venous thrombosis, thus, represents a promising biomarker. Patients with clinically suspected DVT (N = 159) were prospectively recruited and underwent manual compression ultrasonography (CCUS) to confirm or exclude DVT. The diagnostic value of D-Dimer, sPECAM-1 and the combination of both was assessed. sPECAM-1 levels were significantly higher in patients with DVT (N = 44) compared to patients without DVT (N = 115) (85.9 [76.1/98.0] ng/mL versus 68.0 [50.1/86.0] ng/mL; p < 0.001) with a diagnostic sensitivity of 100% and a specificity of 28.7% at the cut point > 50.2 ng/mL. sPECAM-1 improved the diagnostic accuracy of D-Dimer: the combination of both biomarkers yielded a ROC-AUC of 0.925 compared to 0.905 for D-Dimer alone and 0.721 for sPECAM-1 alone with a reduction of false-positive D-Dimer cases 72- > 43 (Δ = - 31.9%). The discrimination mainly occurred in a subgroup of patients characterized by an inflammatory background (defined by c-reactive protein level > 1 mg/mL). sPECAM-1 represents a novel diagnostic biomarker for venous thrombosis. It does not qualify as a diagnostic biomarker alone but improves the diagnostic accuracy of D-Dimer in patients with suspected DVT.


Assuntos
Produtos de Degradação da Fibrina e do Fibrinogênio/análise , Molécula-1 de Adesão Celular Endotelial a Plaquetas/sangue , Trombose Venosa/diagnóstico , Adulto , Idoso , Idoso de 80 Anos ou mais , Biomarcadores/sangue , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Estudos Prospectivos , Reprodutibilidade dos Testes , Trombose Venosa/sangue
9.
Wien Klin Wochenschr ; 132(5-6): 155-160, 2020 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-32130522

RESUMO

BACKGROUND: In 2015 medical training regulations have been restructured for postgraduate medical training in Austria resulting in a significant shortening of the training period. Furthermore, a restriction of working hours for physicians to 48 h per week was implemented affecting the framework of postgraduate medical training. The aim of this study was to obtain a self-assessment of students and young physicians in Austria regarding their self-confidence in clinical skills and their working and learning environment. METHODS: In this study 6th year medical students, physicians in their basic training (common trunk), physicians in family medicine training, and residents in their first 18 months of training were asked to participate in a survey. Self-reported data were collected for five different prespecified domains (communication, motor skills, knowledge, documentation, and emergency). RESULTS: In all domains, self-confidence increased significantly during medical training. Analysis further revealed better results of residents compared with all other groups in all domains, whereas physicians in family medicine training only rated themselves better in the documentation domain (p = 0.010); however, the interest in family medicine was low, even among physicians in family medicine training. The workload significantly increased during medical education, with the highest stress levels for physicians in family medicine training and residents (p = 0.001). CONCLUSIONS: Self-confidence of young physicians but also their stress levels increased during the medical training. Further studies are needed to answer the question why the interest in family medicine was so unexpectedly low in this cohort.


Assuntos
Internato e Residência , Estudantes de Medicina , Adulto , Áustria , Competência Clínica , Feminino , Humanos , Masculino , Autoavaliação (Psicologia) , Estudantes de Medicina/psicologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA