Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 129
Filtrar
1.
JACC Cardiovasc Interv ; 17(6): 742-752, 2024 Mar 25.
Artigo em Inglês | MEDLINE | ID: mdl-38538170

RESUMO

BACKGROUND: Coronary obstruction (CO) is a potentially life-threatening complication of transcatheter aortic valve replacement (TAVR). Chimney stenting or leaflet laceration with transcatheter electrosurgery (Bioprosthetic or Native Aortic Scallop Intentional Laceration to Prevent Iatrogenic Coronary Artery Obstruction [BASILICA]) are 2 techniques developed to prevent CO. OBJECTIVES: The aim of the present study was to compare periprocedural and 1-year outcomes of chimney and BASILICA in TAVR patients at high risk of CO. METHODS: This multicenter observational registry enrolled consecutive TAVR patients at high risk of CO, undergoing either preventive chimney stenting or BASILICA. Clinical success was defined as successful performance of the chimney or BASILICA technique without clinically relevant ostial CO. The primary endpoint was major adverse cardiovascular events, a composite of death, myocardial infarction, stroke, or unplanned target lesion coronary revascularization at 1 year. RESULTS: A total of 168 patients were included: 71 (42.3%) received chimney stenting, and 97 (57.7%) underwent BASILICA. Patients undergoing BASILICA had higher preprocedural risk of CO, as indicated by lower sinotubular junction height (18.2 ± 4.8 mm vs 14.8 ± 3.4 mm; P < 0.001) and diameter (28.2 ± 4.5 vs 26.8 ± 3.4; P = 0.029). Rates of periprocedural complications were similar between the 2 groups. Clinical success was 97.2% and 96.9% in chimney and BASILICA, respectively (P = 0.92). At 1-year follow-up, the cumulative incidence of major adverse cardiovascular events was 18.7% (95% CI: 11%-30.6%) in the chimney group and 19.9% (95% CI: 12.1%-31.5%) in the BASILICA group (log-rank P = 0.848), whereas chimney was associated with a numerically higher cardiovascular mortality than BASILICA (6.7% vs 1.3%; log-rank P = 0.168). CONCLUSIONS: Chimney stenting and BASILICA effectively prevent TAVR-induced acute CO. Both techniques seem to have comparable acceptable periprocedural and 1-year outcomes.


Assuntos
Estenose da Valva Aórtica , Oclusão Coronária , Próteses Valvulares Cardíacas , Lacerações , Substituição da Valva Aórtica Transcateter , Humanos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/métodos , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Lacerações/complicações , Lacerações/cirurgia , Próteses Valvulares Cardíacas/efeitos adversos , Resultado do Tratamento , Oclusão Coronária/etiologia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/complicações , Desenho de Prótese
2.
Clin Res Cardiol ; 2024 Jan 03.
Artigo em Inglês | MEDLINE | ID: mdl-38170246

RESUMO

BACKGROUND: Cardiac allograft vasculopathy (CAV) is still the main drawback of heart transplantation (HTx) and percutaneous coronary intervention (PCI) is a palliative measure because of the high incidence of failure. OBJECTIVE: This study aimed to investigate the safety and efficacy of bioresorbable scaffolds (BRSs) as potential novel therapeutic tool for the treatment of coronary stenoses in CAV. METHODS: This is a multicenter, single-arm, prospective, open-label study (CART, NCT02377648), that included patients affected by advanced CAV treated with PCI and second-generation ABSORB BRS (Abbott Vascular). The primary endpoint was the incidence of 12-month angiographic in-segment scaffold restenosis (ISSR). Secondary endpoints were the incidence of major adverse cardiac events (MACEs) at 12- and 36-month follow-up and the incidence of ISSR at 36 months. A paired intracoronary imaging analysis at baseline and follow-up was also performed. RESULTS: Between 2015 and 2017 35 HTx patients were enrolled and treated for 44 coronary lesions with 51 BRSs. The primary endpoint occurred in 13.5% of the lesions (5/37), with a cumulative ISSR rate up to 3 years of 16.2% (6/37). Angiographic lumen loss was 0.40 ± 0.62 mm at 12 months and 0.53 ± 0.57 mm at 36 months. Overall survival rate was 91.4% and 74.3%, and MACEs incidence 14.2% and 31.4% at 12 and 36 months, respectively. At the paired intracoronary imaging analysis, a significant increase of the vessel external elastic membrane area in the treated segment and some progression of CAV proximally to the BRS were detected. CONCLUSIONS: BRS-based PCI for the treatment of CAV is feasible and safe, with an ISSR incidence similar to what reported in retrospective studies with drug-eluting stents.

3.
Int J Cardiol ; 397: 131659, 2024 Feb 15.
Artigo em Inglês | MEDLINE | ID: mdl-38101704

RESUMO

BACKGROUND: In patients with acute coronary syndromes (ACS), current guidelines recommend a low-density lipoprotein cholesterol (LDL-C) level < 1.4 mmol/L (<55 mg/dL). METHODS: The JET-LDL is a multicenter, observational, prospective registry created to investigate levels of LDL-C in consecutive patients with ACS undergoing PCI at 35 Italian hospitals, and to report their lipid lowering therapies (LLT). Follow-up was planned at 1 and 3 months. LDL-C reduction >50% from baseline or level < 55 mg/dL at 1-month was the primary endpoint. RESULTS: A total of 1095 patients were included: median age was 67 (58-75); 33.7% were already on LLT. Baseline LDL-C levels was 105 (76.5-137) mg/dL. At hospital discharge all patients were on LLT: 98.1% received statins (as mono or combination therapy), ezetimibe and PCSK9i were used in 60.1% and 8.5% of cases, respectively. Primary endpoint was achieved in 62% (95% CI 58-65) of cases. At 1-month LDL-C levels dropped to 53 (38-70) mg/dL (p < 0.001 vs baseline) and it was <55 mg/dL in 53% (95% CI 49-57) of patients; however, PCSK9i were added to 7 further cases. At 3-months 58% (95% CI 55-62) of patients achieved the target level, but PCSK9i was added to only 11 new patients. CONCLUSIONS: In this real-world registry of ACS patients undergoing PCI, recommend LDL-C levels were obtained in 62% of patients, but PCSK9i prescription was limited to 10% of cases. As LLT pattern appeared mainly improved at hospital discharge, an early and strong treatment should be considered.


Assuntos
Síndrome Coronariana Aguda , Anticolesterolemiantes , Inibidores de Hidroximetilglutaril-CoA Redutases , Intervenção Coronária Percutânea , Idoso , Humanos , Síndrome Coronariana Aguda/diagnóstico , Síndrome Coronariana Aguda/tratamento farmacológico , Síndrome Coronariana Aguda/cirurgia , Anticolesterolemiantes/uso terapêutico , LDL-Colesterol , Inibidores de Hidroximetilglutaril-CoA Redutases/uso terapêutico , Sistema de Registros , Resultado do Tratamento , Pessoa de Meia-Idade , Estudos Multicêntricos como Assunto , Estudos Observacionais como Assunto
5.
J Invasive Cardiol ; 35(11)2023 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-37992330

RESUMO

BACKGROUND: Transcatheter edge-to-edge repair (TEER) using the MitraClip (Abbott Vascular) system has emerged as a standard treatment for patients with symptomatic severe secondary or inoperable primary mitral regurgitation (MR). The relatively recent approval of the PASCAL Transcatheter Valve Repair System (Edwards Lifesciences) has expanded the options of TEER devices. However, evidence comparing PASCAL with MitraClip systems is still limited. METHODS: We conducted a systematic literature research and meta-analysis in PubMed, Medline, and EMBASE databases for studies comparing PASCAL and MitraClip systems. RESULTS: Four observational studies and 1 randomized controlled trial, involving 1315 patients total, were eligible for inclusion. All patients exhibited symptomatic (NYHA II-IV) MR grades 3+ or 4+. Baseline characteristics were comparable across all included studies. The clinical outcomes were assessed according to the Mitral Valve Academic Research Consortium consensus. The procedural success rates for the 2 devices were comparable in terms of achieving post-procedural MR grades of less than or equal to 2+ and less than or equal to 1+. Furthermore, most patients improved their clinical status, with no significant differences between patients treated with PASCAL and those treated with MitraClip. In terms of safety, both procedures exhibited low overall mortality rates and occurrence of major adverse events (MAE), without significant difference between the 2 devices. These findings remained consistent in both short- and long-term follow-up assessments. CONCLUSIONS: Our study revealed similar effectiveness and safety profiles between the PASCAL and MitraClip devices in patients experiencing significant symptomatic MR.


Assuntos
Procedimentos Cirúrgicos Cardíacos , Implante de Prótese de Valva Cardíaca , Insuficiência da Valva Mitral , Humanos , Cateterismo Cardíaco/métodos , Catéteres , Implante de Prótese de Valva Cardíaca/métodos , Valva Mitral/diagnóstico por imagem , Valva Mitral/cirurgia , Insuficiência da Valva Mitral/diagnóstico , Insuficiência da Valva Mitral/cirurgia , Insuficiência da Valva Mitral/etiologia , Resultado do Tratamento
6.
Medicina (Kaunas) ; 59(10)2023 Oct 11.
Artigo em Inglês | MEDLINE | ID: mdl-37893524

RESUMO

Background and Objectives. Recent guidelines have downgraded the routine use of the intra-aortic balloon pump (IABP) in patients with cardiogenic shock (CS) due to ST-elevation myocardial infarction (STEMI). Despite this, its use in clinical practice remains high. The aim of this study was to evaluate the prognostic impact of the IABP in patients with STEMI complicated by CS undergoing primary PCI (pPCI), focusing on patients with anterior MI in whom a major benefit has been previously hypothesized. Materials and Methods. We enrolled 2958 consecutive patients undergoing pPCI for STEMI in our department from 2005 to 2018. Propensity score matching and mortality analysis were performed. Results. CS occurred in 246 patients (8.3%); among these patients, 145 (60%) had anterior AMI. In the propensity-matched analysis, the use of the IABP was associated with a lower 30-day mortality (39.3% vs. 60.9%, p = 0.032) in the subgroup of patients with anterior STEMI. Conversely, in the whole group of CS patients and in the subgroup of patients with non-anterior STEMI, IABP use did not have a significant impact on mortality. Conclusions. The use of the IABP in cases of STEMI complicated by CS was found to improve survival in patients with anterior infarction. Prospective studies are needed before abandoning or markedly limiting the use of the IABP in this clinical setting.


Assuntos
Infarto do Miocárdio , Infarto do Miocárdio sem Supradesnível do Segmento ST , Intervenção Coronária Percutânea , Infarto do Miocárdio com Supradesnível do Segmento ST , Humanos , Choque Cardiogênico/cirurgia , Choque Cardiogênico/complicações , Infarto do Miocárdio com Supradesnível do Segmento ST/complicações , Infarto do Miocárdio com Supradesnível do Segmento ST/cirurgia , Intervenção Coronária Percutânea/métodos , Balão Intra-Aórtico/efeitos adversos , Balão Intra-Aórtico/métodos , Infarto do Miocárdio sem Supradesnível do Segmento ST/etiologia , Resultado do Tratamento
7.
Artigo em Inglês | MEDLINE | ID: mdl-37870421

RESUMO

Concomitant presence of atrial fibrillation and coronary artery disease requiring percutaneous coronary intervention is a frequent occurrence. The choice of optimal antithrombotic therapy, in this context, is still challenging. To offer the best protection both in terms of stroke and stent thrombosis, triple therapy with oral anticoagulation and dual antiplatelet therapy would be required. Several drug combinations have been tested in recent years, including direct oral anticoagulants, with the aim of balancing ischemic and bleeding risk. Both pharmacokinetic aspects of the molecules and patient's characteristics should be analyzed in choosing oral anticoagulation. Then, as suggested by guidelines, triple therapy should start with a seven-day duration and the aim to prolong to thirty days in high thrombotic risk patients. Dual therapy should follow to reach twelve months after coronary intervention. Even not fully discussed by the guidelines, in order to balance ischemic and bleeding risk it should also be considered: 1) integrated assessment of coronary artery disease and procedural complexity of coronary intervention; 2) appropriateness to maintain the anticoagulant drug dosage indicated in technical data sheet; the lack of data on the suspension of antiplatelet drugs one year after percutaneous intervention; 3) the possibility of combination therapy with ticagrelor; and 4) the need to treat the occurrence of paroxysmal atrial fibrillation during acute coronary syndrome. With data provided clinician should pursue a therapy as personalized as possible, both in terms of drug choice and treatment duration, in order to balance ischemic and bleeding risk.

8.
G Ital Cardiol (Rome) ; 24(10): 800-809, 2023 Oct.
Artigo em Italiano | MEDLINE | ID: mdl-37767832

RESUMO

The management of the patient with fever in the intensive cardiac care unit begins with a thorough evaluation of the patient, particularly symptoms, clinical history and physical examination, to provide information regarding the origin of the fever. The global evaluation of the patient should be integrated with blood and microbiological tests, in particular blood culture and swab. The laboratory, microbiologic or radiologic tests could be more or less detailed and targeted depending on the type of suspected infection and clinical conditions of the patient. When therapy is necessary, it is crucial to switch, as soon as possible, from broad spectrum antibiotic therapy to antibiotic therapy based on the results of the microbiological exams. Antibiotic therapy could be associated with antipyretic and specific organ support therapy when necessary.


Assuntos
Febre , Unidades de Terapia Intensiva , Humanos , Febre/etiologia , Febre/terapia , Antibacterianos/uso terapêutico
9.
Eur Heart J Cardiovasc Pharmacother ; 9(8): 709-721, 2023 Dec 14.
Artigo em Inglês | MEDLINE | ID: mdl-37634083

RESUMO

AIMS: To summarize the totality of evidence validating the Predicting Bleeding Complications in Patients Undergoing Stent Implantation and Subsequent Dual Antiplatelet Therapy (PRECISE-DAPT) score, ascertaining its aggregate discrimination and validation power in multiple population subsets. METHODS AND RESULTS: We searched electronic databases from 2017 (PRECISE-DAPT proposal) up to March 2023 for studies that reported the occurrence of out-of-hospital bleedings according to the PRECISE-DAPT score in patients receiving DAPT following percutaneous coronary intervention (PCI). Pooled odds ratios (OR) with 95% confidence interval (CI) were used as summary statistics and were calculated using a random-effects model. Primary and secondary endpoints were the occurrence of any and major bleeding, respectively. A total of 21 studies and 67 283 patients were included; 24.7% of patients (N = 16 603) were at high bleeding risk (PRECISE-DAPT score ≥25), and when compared to those at low bleeding risk, they experienced a significantly higher rate of any out-of-hospital bleeding (OR: 2.71; 95% CI: 2.24-3.29; P-value <0.001) and major bleedings (OR: 3.51; 95% CI: 2.71-4.55; P-value <0.001). Pooling data on c-stat whenever available, the PRECISE-DAPT score showed a moderate discriminative power in predicting major bleeding events at 1 year (pooled c-stat: 0.71; 95% CI: 0.64-0.77). CONCLUSION: This systematic review and meta-analysis confirms the external validity of the PRECISE-DAPT score in predicting out-of-hospital bleeding outcomes in patients on DAPT following PCI. The moderate discriminative ability highlights the need for future improved risk prediction tools in the field.


Assuntos
Intervenção Coronária Percutânea , Inibidores da Agregação Plaquetária , Humanos , Inibidores da Agregação Plaquetária/efeitos adversos , Intervenção Coronária Percutânea/efeitos adversos , Hemorragia/induzido quimicamente , Stents
10.
JACC Cardiovasc Interv ; 16(16): 2004-2017, 2023 08 28.
Artigo em Inglês | MEDLINE | ID: mdl-37480891

RESUMO

OBJECTIVES: The authors sought to evaluate the incidence, predictors, and outcomes of new permanent pacemaker implantation (PPI) after transcatheter aortic valve replacement (TAVR) with contemporary self-expanding valves (SEV). BACKGROUND: Need for PPI is frequent post-TAVR, but conflicting data exist on new-generation SEV and on the prognostic impact of PPI. METHODS: This study included 3,211 patients enrolled in the multicenter NEOPRO (A Multicenter Comparison of Acurate NEO Versus Evolut PRO Transcatheter Heart Valves) and NEOPRO-2 (A Multicenter Comparison of ACURATE NEO2 Versus Evolut PRO/PRO+ Transcatheter Heart Valves 2) registries (January 2012 to December 2021) who underwent transfemoral TAVR with SEV. Implanted transcatheter heart valves (THV) were Acurate neo (n = 1,090), Acurate neo2 (n = 665), Evolut PRO (n = 1,312), and Evolut PRO+ (n = 144). Incidence and predictors of new PPI and 1-year outcomes were evaluated. RESULTS: New PPI was needed in 362 patients (11.3%) within 30 days after TAVR (8.8%, 7.7%, 15.2%, and 10.4%, respectively, after Acurate neo, Acurate neo2, Evolut PRO, and Evolut PRO+). Independent predictors of new PPI were Society of Thoracic Surgeons Predicted Risk of Mortality score, baseline right bundle branch block and depth of THV implantation, both in patients treated with Acurate neo/neo2 and in those treated with Evolut PRO/PRO+. Predischarge reduction in ejection fraction (EF) was more frequent in patients requiring PPI (P = 0.014). New PPI was associated with higher 1-year mortality (16.9% vs 10.8%; adjusted HR: 1.66; 95% CI: 1.13-2.43; P = 0.010), particularly in patients with baseline EF <40% (P for interaction = 0.049). CONCLUSIONS: New PPI was frequently needed after TAVR with SEV (11.3%) and was associated with higher 1-year mortality, particularly in patients with EF <40%. Baseline right bundle branch block and depth of THV implantation independently predicted the need of PPI.


Assuntos
Marca-Passo Artificial , Substituição da Valva Aórtica Transcateter , Humanos , Incidência , Bloqueio de Ramo , Prognóstico , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento
11.
JACC cardiovasc. interv ; (23): (23)00846-4, jul.2023. ilus
Artigo em Inglês | Sec. Est. Saúde SP, CONASS, SESSP-IDPCPROD, Sec. Est. Saúde SP | ID: biblio-1444382

RESUMO

OBJECTIVES: The authors sought to evaluate the incidence, predictors, and outcomes of new permanent pacemaker implantation (PPI) after transcatheter aortic valve replacement (TAVR) with contemporary self-expanding valves (SEV). BACKGROUND: Need for PPI is frequent post-TAVR, but conflicting data exist on new-generation SEV and on the prognostic impact of PPI. METHODS: This study included 3,211 patients enrolled in the multicenter NEOPRO (A Multicenter Comparison of Acurate NEO Versus Evolut PRO Transcatheter Heart Valves) and NEOPRO-2 (A Multicenter Comparison of ACURATE NEO2 Versus Evolut PRO/PRO+ Transcatheter Heart Valves 2) registries (January 2012 to December 2021) who underwent transfemoral TAVR with SEV. Implanted transcatheter heart valves (THV) were Acurate neo (n = 1,090), Acurate neo2 (n = 665), Evolut PRO (n = 1,312), and Evolut PRO+ (n = 144). Incidence and predictors of new PPI and 1-year outcomes were evaluated. RESULTS: New PPI was needed in 362 patients (11.3%) within 30 days after TAVR (8.8%, 7.7%, 15.2%, and 10.4%, respectively, after Acurate neo, Acurate neo2, Evolut PRO, and Evolut PRO+). Independent predictors of new PPI were Society of Thoracic Surgeons Predicted Risk of Mortality score, baseline right bundle branch block and depth of THV implantation, both in patients treated with Acurate neo/neo2 and in those treated with Evolut PRO/PRO+. Predischarge reduction in ejection fraction (EF) was more frequent in patients requiring PPI (P = 0.014). New PPI was associated with higher 1-year mortality (16.9% vs 10.8%; adjusted HR: 1.66; 95% CI: 1.13-2.43; P = 0.010), particularly in patients with baseline EF <40% (P for interaction = 0.049). CONCLUSIONS: New PPI was frequently needed after TAVR with SEV (11.3%) and was associated with higher 1-year mortality, particularly in patients with EF <40%. Baseline right bundle branch block and depth of THV implantation independently predicted the need of PPI.


Assuntos
Marca-Passo Artificial
13.
JACC Cardiovasc Interv ; 16(9): 1081-1091, 2023 05 08.
Artigo em Inglês | MEDLINE | ID: mdl-37164607

RESUMO

BACKGROUND: Long-term right ventricular pacing (VP) has been related to negative left ventricular remodeling and heart failure (HF), but there is a lack of evidence regarding the prognostic impact on transcatheter aortic valve replacement (TAVR) patients. OBJECTIVES: The aim of the PACE-TAVI registry is to evaluate the association of high percentage of VP with adverse outcomes in patients with pacemaker implantation after TAVR. METHODS: PACE-TAVI is an international multicenter registry of all consecutive TAVR patients who underwent permanent pacemaker implantation for conduction disturbances in the first 30 days after the procedure. Patients were divided into 2 subgroups according to the percentage of VP (<40% vs ≥40%) at pacemaker interrogation. The primary endpoint was the composite of cardiovascular mortality or hospitalization for HF. RESULTS: A total of 377 patients were enrolled, 158 with VP <40% and 219 with VP ≥40%. After multivariable adjustment, VP ≥40% was associated with a higher incidence of the primary endpoint (HR: 2.76; 95% CI: 1.39-5.51; P = 0.004), first HF hospitalization (HR: 3.37; 95% CI: 1.50-7.54; P = 0.003), and cardiovascular death (HR: 3.77; 95% CI: 1.02-13.88; P = 0.04), while the incidence of all-cause death was not significantly different (HR: 2.17; 95% CI: 0.80-5.90; P = 0.13). Patients with VP ≥ 40% showed a higher New York Heart Association functional class both at 1 year (P = 0.009) and at last available follow-up (P = 0.04) and a nonsignificant reduction of left ventricular ejection fraction (P = 0.18) on 1-year echocardiography, while patients with VP <40% showed significant improvement (P = 0.009). CONCLUSIONS: In TAVR patients undergoing permanent pacemaker implantation, a high percentage of right VP at follow-up is associated with an increased risk for cardiovascular death and HF hospitalization. These findings suggest the opportunity to minimize right VP through dedicated algorithms in post-TAVR patients without complete atrioventricular block and to evaluate a more physiological VP modality in patients with persistent complete atrioventricular block.


Assuntos
Estenose da Valva Aórtica , Bloqueio Atrioventricular , Marca-Passo Artificial , Substituição da Valva Aórtica Transcateter , Humanos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Bloqueio Atrioventricular/diagnóstico , Bloqueio Atrioventricular/etiologia , Bloqueio Atrioventricular/terapia , Volume Sistólico , Estimulação Cardíaca Artificial/efeitos adversos , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Fatores de Risco , Função Ventricular Esquerda , Resultado do Tratamento , Marca-Passo Artificial/efeitos adversos , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia
15.
Circ Cardiovasc Interv ; 16(1): e012538, 2023 01.
Artigo em Inglês | MEDLINE | ID: mdl-36649387

RESUMO

BACKGROUND: In recent years, transcatheter aortic valve replacement (TAVR) techniques and technology have continuously improved. Data regarding the impact of these advancements on outcomes in large real-world settings are still limited. The aim of this study was to investigate temporal trends and assess contemporary outcomes after TAVR with Evolut PRO/PRO+ supra-annular self-expanding valves. METHODS: This study included patients enrolled in the multicenter NEOPRO (A Multicenter Comparison of Acurate NEO Versus Evolut PRO Transcatheter Heart Valves) and NEOPRO-2 (A Multicenter Comparison of ACURATE NEO2 Versus Evolut PRO/PRO+ Transcatheter Heart Valves 2) registries who underwent transfemoral TAVR with Evolut PRO/PRO+. Procedural dates (August 2017 through November 2021) were stratified in quartiles (Q) and used to investigate temporal trends in TAVR outcomes. Predischarge, 30-day Valve Academic Research Consortium-3 defined, and 1-year outcomes were evaluated. RESULTS: In total, 1616 patients from 28 centers were included. Over time, patients had lower Society of Thoracic Surgeon-Predicted Risk of Mortality score (Q1-4, 4.1% [2.8-6.3%], 3.7% [2.6-5.3%], 3.3% [2.4-4.9%], 2.9% [2.2-4.3%]; P<0.001) and more moderate or heavy valve calcification (Q1-4, 80%, 80%, 82%, 88%; P=0.038). Overall Valve Academic Research Consortium-3 technical success was 94.1%, with 30-day and 1-year all-cause mortality of 2.4% and 10%, respectively. Throughout the study period, procedures were associated with higher rates of 30-day device success (Q1-4, 81.2%, 82.2%, 82.0%, 88.0%; Cochran-Armitage P=0.023) and early safety (Q1-4, 66.8%, 67.5%, 74.0%, 77.6%; Cochran-Armitage P<0.001), with fewer permanent pacemaker implantations (Q1-4: 15.3%, 20.0%, 12.1%, 11.6%; Cochran-Armitage P=0.023) and residual mild or greater paravalvular leaks (Q1-4, 50.4%, 42.1%, 36.5%, 35.8%; Cochran-Armitage P<0.001). CONCLUSIONS: TAVR with Evolut PRO/PRO+ self-expanding valve is safe and effective. Despite the treatment of heavier calcified anatomies, procedural outcomes are improving over time with less need for pacemaker implantation and less significant paravalvular leaks.


Assuntos
Estenose da Valva Aórtica , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Humanos , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Fatores de Tempo , Resultado do Tratamento , Sistema de Registros , Desenho de Prótese , Fatores de Risco
16.
Am J Cardiol ; 188: 7-14, 2023 02 01.
Artigo em Inglês | MEDLINE | ID: mdl-36446228

RESUMO

Although several studies have previously reported on the efficacy of percutaneous coronary intervention (PCI) with first-generation drug-eluting stents (DES) in heart transplant patients with cardiac allograft vasculopathy, few data regarding new-generation DES are currently available. We sought to compare the efficacy of new-generation versus first-generation DES in 90 consecutive patients with heart transplant (113 de novo coronary lesions) who underwent urgent or elective PCI with first-generation (28 patients) or new-generation (62 patients) DES. For each patient, the severity of cardiac allograft vasculopathy and postprocedural extent of revascularization were quantified calculating baseline and residual SYNTAX score, respectively. The primary end point was a composite of major adverse cardiac events-myocardial infarction, cardiovascular death, or target vessel revascularization-at 3 years. Overall, the median baseline SYNTAX score was 8 (5 to 15), and a total number of stents per patient of 1.6 ± 0.9 was implanted. Post-PCI residual SYNTAX score was 1.5 (0 to 4), with 13 patients having a score >8. At 3 years, the Kaplan-Meier estimate of freedom from major adverse cardiac events was 64%, with no differences between first-generation and new-generation DES groups (log-rank test p = 0.269). Nevertheless, patients treated with new-generation DES experienced a lower rate of target vessel revascularization (15% vs 31%, log-rank test p = 0.058). In the multivariate Cox regression analysis, a post-PCI residual SYNTAX score >8 (hazard ratio 2.37, confidence interval 0.98 to 5.73, p = 0.054) was identified as an independent predictor of the primary end point.


Assuntos
Doença da Artéria Coronariana , Stents Farmacológicos , Cardiopatias , Transplante de Coração , Intervenção Coronária Percutânea , Humanos , Intervenção Coronária Percutânea/efeitos adversos , Resultado do Tratamento , Cardiopatias/etiologia , Stents , Aloenxertos , Estimativa de Kaplan-Meier , Doença da Artéria Coronariana/terapia , Fatores de Risco
20.
EuroIntervention ; 18(12): 977-986, 2023 Jan 23.
Artigo em Inglês | MEDLINE | ID: mdl-36093795

RESUMO

BACKGROUND: The ACURATE neo2 (NEO2) and Evolut PRO/PRO+ (PRO) bioprostheses are new-generation self-expanding valves developed for transcatheter aortic valve replacement (TAVR). AIMS: We sought to compare the performance of the ACURATE neo2 and Evolut PRO/PRO+ devices. METHODS: The NEOPRO-2 registry retrospectively included patients who underwent TAVR for severe aortic stenosis with either the NEO2 or PRO devices between August 2017 and December 2021 at 20 centres. In-hospital and 30-day Valve Academic Research Consortium (VARC)-3 defined outcomes were evaluated. Propensity score (PS) matching and binary logistic regression were performed to adjust the treatment effect for PS quintiles. A subgroup analysis assessed the impact of aortic valve calcification. RESULTS: A total of 2,175 patients (NEO2: n=763; PRO: n=1,412) were included. The mean age was 82±6.2 years and the mean Society of Thoracic Surgeons score was 4.2%. Periprocedural complications were low, and both groups achieved high rates of technical success (93.1% vs 94.1%; p=0.361) and predischarge intended valve performance (96.0% vs 94.1%; p=0.056), both in the unmatched and matched analysis (452 pairs). Device success at 30 days was comparable (84.3% vs 83.6%; p=0.688), regardless of aortic valve calcification severity (p>0.05 for interaction). A suggestion for higher VARC-3 early safety in the NEO2 group was mainly driven by reduced rates of new permanent pacemaker implantation (7.7% vs 15.6%; p<0.001). CONCLUSIONS: This retrospective analysis reports a similar short-term performance of the ACURATE neo2 platform compared with the new-generation Evolut PRO/PRO+ devices. Randomised studies are needed to confirm our exploratory findings.


Assuntos
Estenose da Valva Aórtica , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Idoso , Idoso de 80 Anos ou mais , Humanos , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/complicações , Próteses Valvulares Cardíacas/efeitos adversos , Complicações Pós-Operatórias/etiologia , Desenho de Prótese , Estudos Retrospectivos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA