Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 10 de 10
Filtrar
1.
BMC Infect Dis ; 22(1): 91, 2022 Jan 27.
Artigo em Inglês | MEDLINE | ID: mdl-35086474

RESUMO

BACKGROUND: D-dimer was introduced in 2018 as an alternative biomarker for C-reactive protein (CRP) in the diagnostic of prosthetic joint infection (PJI) criteria of the Musculoskeletal Infection Society. We assessed the accuracy of plasma D-dimer for the diagnosis of early, delayed, and late PJI according to Infectious Diseases Society of America (IDSA) criteria, and whether persistently high levels of D-dimer in cases of aseptic loosening (AL) may be predictive of subsequent implant-related infection. METHODS: A prospective study of a consecutive series of 187 revision arthroplasties was performed at a single institution. Septic (n = 39) and aseptic revisions (n = 141) were classified based on IDSA criteria. Preoperative assessment of CRP, erythrocyte sedimentation rate (ESR) and D-dimer was performed. Receiver operating curves were used to determine maximum sensitivity and specificity of the biomarkers. The natural progress of D-dimer for AL cases was followed up either until the date of implant-related infection at any time during the first year or 1 year after revision in patients without failure. Clinical outcomes for those AL cases included infection-related failure that required a new surgery or need for antibiotic suppression. RESULTS: Preoperative D-dimer level was significantly higher in PJI cases than in AL cases (p = 0.000). The optimal threshold of D-dimer for the diagnosis of PJI was 1167 ng/mL. For overall diagnosis of PJI, C-reactive protein (CRP) achieved the highest sensitivity (84.6%), followed by erythrocyte sedimentation rate (ESR) and D-dimer (82% and 71.8%, respectively). Plasma D-dimer sensitivity was lower for all PJI types. When combinations of 2 tests were studied, the combined use of ESR and CRP achieved the best accuracy for all types of PJI (76.9%). 4.25% of AL cases had implant failure due to implant-related infection during the first year after the index revision arthroplasty, only the cases with early failure maintained high D-dimer levels. CONCLUSIONS: Plasma D-dimer did not offer an improvement over the individual or combined diagnosis for any type of PJI according to IDSA criteria. Persistently raised levels of D-dimer after revision arthroplasty in AL cases might be used to effectively diagnose early postoperative infection.


Assuntos
Artroplastia de Quadril , Doenças Transmissíveis , Infecções Relacionadas à Prótese , Artroplastia de Quadril/efeitos adversos , Biomarcadores , Proteína C-Reativa/análise , Produtos de Degradação da Fibrina e do Fibrinogênio , Humanos , Estudos Prospectivos , Infecções Relacionadas à Prótese/diagnóstico , Infecções Relacionadas à Prótese/cirurgia , Reoperação , Estudos Retrospectivos , Sensibilidade e Especificidade
2.
Sci Rep ; 9(1): 7852, 2019 May 21.
Artigo em Inglês | MEDLINE | ID: mdl-31110203

RESUMO

A correction to this article has been published and is linked from the HTML and PDF versions of this paper. The error has not been fixed in the paper.

3.
Artigo em Inglês | MEDLINE | ID: mdl-30858217

RESUMO

Dalbavancin is a lipoglycopeptide with potent activity against Gram-positive microorganisms, a long half-life, a favorable safety profile, and a high concentration in bone, which makes it an interesting alternative for treatment of osteoarticular infections. We performed a multicentric retrospective study of all patients with an osteoarticular infection (septic arthritis, spondylodiscitis, osteomyelitis, or orthopedic implant-related infection) treated with at least one dose of dalbavancin between 2016 and 2017 in 30 institutions in Spain. In order to evaluate the response, patients with or without an orthopedic implant were separated. A total of 64 patients were included. Staphylococcus epidermidis and Staphylococcus aureus were the most frequent microorganisms. The reasons for switching to dalbavancin were simplification (53.1%), adverse events (25%), or failure (21.9%). There were 7 adverse events, and no patient had to discontinue dalbavancin. In 45 cases, infection was related to an orthopedic implant. The implant material was retained in 23 cases, including that in 15 (65.2%) patients that were classified as cured and 8 (34.8%) that presented improvement. In 21 cases, the implants were removed, including those in 16 (76.2%) cases that were considered successes, 4 (19%) cases were considered improved, and 1 (4.8%) case that was considered a failure. Among the 19 cases without implants, 14 (73.7%) were considered cured, 3 (15.8%) were considered improved, and 2 (10.5%) were considered failures. The results show that dalbavancin is a well-tolerated antibiotic, even when >2 doses are administered, and is associated with a high cure rate. These are preliminary data with a short follow-up; therefore, it is necessary to gain more experience and, in the future, to establish the most appropriate dose and frequency.


Assuntos
Osso e Ossos/microbiologia , Articulações/microbiologia , Osteomielite/microbiologia , Teicoplanina/análogos & derivados , Idoso , Feminino , Bactérias Gram-Positivas/efeitos dos fármacos , Bactérias Gram-Positivas/patogenicidade , Humanos , Masculino , Testes de Sensibilidade Microbiana , Pessoa de Meia-Idade , Osteomielite/tratamento farmacológico , Staphylococcus aureus , Staphylococcus epidermidis/efeitos dos fármacos , Staphylococcus epidermidis/patogenicidade , Teicoplanina/uso terapêutico
4.
Sci Rep ; 8(1): 16706, 2018 11 12.
Artigo em Inglês | MEDLINE | ID: mdl-30420604

RESUMO

The hyperarid core of the Atacama Desert, the driest and oldest desert on Earth, has experienced a number of highly unusual rain events over the past three years, resulting in the formation of previously unrecorded hypersaline lagoons, which have lasted several months. We have systematically analyzed the evolution of the lagoons to provide quantitative field constraints of large-scale impacts of the rains on the local microbial communities. Here we show that the sudden and massive input of water in regions that have remained hyperarid for millions of years is harmful for most of the surface soil microbial species, which are exquisitely adapted to survive with meager amounts of liquid water, and quickly perish from osmotic shock when water becomes suddenly abundant. We found that only a handful of bacteria, remarkably a newly identified species of Halomonas, remain metabolically active and are still able to reproduce in the lagoons, while no archaea or eukaryotes were identified. Our results show that the already low microbial biodiversity of extreme arid regions greatly diminishes when water is supplied quickly and in great volumes. We conclude placing our findings in the context of the astrobiological exploration of Mars, a hyperarid planet that experienced catastrophic floodings in ancient times.


Assuntos
Chuva , Bactérias/classificação , Bactérias/genética , Biodiversidade , Clima Desértico , Microbiota , Microbiologia do Solo
5.
Anaerobe ; 54: 75-82, 2018 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-30118892

RESUMO

The anaerobic Gram-negative rod Fusobacterium nucleatum is an oral commensal and periodontal pathogen that has been associated with a wide variety of infections, yet it is extremely rare to be associated with prosthetic joint infection. After an exhaustive literature review, only two cases of prosthetic joint infection by F. nucleatum have been previously reported. To our knowledge, the case we report on here is the first combined with periprosthetic abscess and related with hemochromatosis. We therefore sought to provide a comprehensive literature review of case reports or series of less commonly encountered anaerobic microorganisms isolated from prosthetic joint infections.


Assuntos
Infecções por Fusobacterium/microbiologia , Fusobacterium nucleatum/fisiologia , Prótese de Quadril/microbiologia , Infecções Relacionadas à Prótese/microbiologia , Adulto , Idoso , Feminino , Fusobacterium nucleatum/genética , Fusobacterium nucleatum/isolamento & purificação , Humanos , Masculino , Pessoa de Meia-Idade
6.
Med Intensiva (Engl Ed) ; 42(1): 5-36, 2018.
Artigo em Inglês, Espanhol | MEDLINE | ID: mdl-29406956

RESUMO

Catheter-related bloodstream infections (CRBSI) constitute an important cause of hospital-acquired infection associated with morbidity, mortality, and cost. The aim of these guidelines is to provide updated recommendations for the diagnosis and management of CRBSI in adults. Prevention of CRBSI is excluded. Experts in the field were designated by the two participating Societies (the Spanish Society of Infectious Diseases and Clinical Microbiology and [SEIMC] and the Spanish Society of Spanish Society of Intensive and Critical Care Medicine and Coronary Units [SEMICYUC]). Short-term peripheral venous catheters, non-tunneled and long-term central venous catheters, tunneled catheters and hemodialysis catheters are covered by these guidelines. The panel identified 39 key topics that were formulated in accordance with the PICO format. The strength of the recommendations and quality of the evidence were graded in accordance with ESCMID guidelines. Recommendations are made for the diagnosis of CRBSI with and without catheter removal and of tunnel infection. The document establishes the clinical situations in which a conservative diagnosis of CRBSI (diagnosis without catheter removal) is feasible. Recommendations are also made regarding empirical therapy, pathogen-specific treatment (coagulase-negative staphylococci, Staphylococcus aureus, Enterococcus spp., Gram-negative bacilli, and Candida spp.), antibiotic lock therapy, diagnosis and management of suppurative thrombophlebitis and local complications.


Assuntos
Bacteriemia/etiologia , Técnicas Bacteriológicas/normas , Infecções Relacionadas a Cateter/diagnóstico , Infecções Relacionadas a Cateter/tratamento farmacológico , Infecção Hospitalar/etiologia , Antibacterianos/uso terapêutico , Antifúngicos/uso terapêutico , Bacteriemia/diagnóstico , Bacteriemia/tratamento farmacológico , Técnicas de Tipagem Bacteriana/métodos , Técnicas de Tipagem Bacteriana/normas , Biofilmes/efeitos dos fármacos , Coleta de Amostras Sanguíneas/métodos , Coleta de Amostras Sanguíneas/normas , Candidemia/tratamento farmacológico , Candidemia/etiologia , Catéteres/efeitos adversos , Catéteres/microbiologia , Tratamento Conservador , Infecção Hospitalar/diagnóstico , Infecção Hospitalar/tratamento farmacológico , Remoção de Dispositivo , Gerenciamento Clínico , Farmacorresistência Bacteriana Múltipla , Endocardite Bacteriana/etiologia , Contaminação de Equipamentos , Humanos , Micologia/métodos , Tromboflebite/etiologia
7.
BMC Infect Dis ; 17(1): 592, 2017 08 25.
Artigo em Inglês | MEDLINE | ID: mdl-28841913

RESUMO

BACKGROUND: A combination of laboratory, histopathological and microbiological tests for diagnosis of prosthetic joint infection (PJI) have been strongly recommended. This study aims to characterize the accuracy of individual or group tests, such as culture of sonicate fluid, synovial fluid and peri-implant tissue, C-reactive protein (CRP) and histopathology for detection of early, delayed and late PJI. METHODS: A prospective study of patients undergoing hip or knee arthroplasty from February 2009 to February 2014 was performed in a Spanish tertiary health care hospital. The diagnostic accuracy of the different methods was evaluated constructing receiver-operating-characteristic (ROC) curve areas. RESULTS: One hundred thirty consecutive patients were included: 18 (13.8%) early PJI, 35 (27%) delayed PJI and 77 (59.2%) late PJI. For individual parameters, the area under the ROC curve for peri-implant tissue culture was larger for early (0.917) than for delayed (0.829) and late PJI (0.778), p = 0.033. There was a significantly larger difference for ROC area in the synovial fluid culture for delayed (0.803) than for early (0.781) and late infections (0.679), p = 0.039. The comparison of the areas under the ROC curves for the two microbiological tests showed that sonicate fluid was significantly different from peri-implant tissue in delayed (0.951 vs 0.829, p = 0.005) and late PJI (0.901 vs 0.778, p = 0.000). The conjunction of preoperative parameters, synovial fluid culture and CRP, improved the accuracy for late PJI (p = 0.01). The conjunction of histopathology and sonicate fluid culture increased the area under ROC curve of sonication in early (0.917 vs 1.000); p = 0.06 and late cases (0.901 vs 0.999); p < 0.001. CONCLUSION: For early PJI, sonicate fluid and peri-implant tissue cultures achieve the same best sensitivity. For delayed and late PJI, sonicate fluid culture is the most sensitive individual diagnostic method. By combining histopathology and peri-implant tissue, all early, 97% of delayed and 94.8% of late cases are diagnosed. The conjunction of histopathology and sonicate fluid culture yields a sensitivity of 100% for all types of infection.


Assuntos
Infecções Relacionadas à Prótese/diagnóstico , Líquido Sinovial/microbiologia , Idoso , Idoso de 80 Anos ou mais , Artroplastia do Joelho/efeitos adversos , Técnicas Bacteriológicas , Proteína C-Reativa/análise , Diagnóstico Tardio , Testes Diagnósticos de Rotina , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Infecções Relacionadas à Prótese/microbiologia , Curva ROC , Sonicação
8.
Clin Microbiol Infect ; 22(8): 732.e1-8, 2016 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-27181408

RESUMO

It is important to know the spectrum of the microbial aetiology of prosthetic joint infections (PJIs) to guide empiric treatment and establish antimicrobial prophylaxis in joint replacements. There are no available data based on large contemporary patient cohorts. We sought to characterize the causative pathogens of PJIs and to evaluate trends in the microbial aetiology. We hypothesized that the frequency of antimicrobial-resistant organisms in PJIs has increased in the recent years. We performed a cohort study in 19 hospitals in Spain, from 2003 to 2012. For each 2-year period (2003-2004 to 2011-2012), the incidence of microorganisms causing PJIs and multidrug-resistant bacteria was assessed. Temporal trends over the study period were evaluated. We included 2524 consecutive adult patients with a diagnosis of PJI. A microbiological diagnosis was obtained for 2288 cases (90.6%). Staphylococci were the most common cause of infection (1492, 65.2%). However, a statistically significant rising linear trend was observed for the proportion of infections caused by Gram-negative bacilli, mainly due to the increase in the last 2-year period (25% in 2003-2004, 33.3% in 2011-2012; p 0.024 for trend). No particular species contributed disproportionally to this overall increase. The percentage of multidrug-resistant bacteria PJIs increased from 9.3% in 2003-2004 to 15.8% in 2011-2012 (p 0.008), mainly because of the significant rise in multidrug-resistant Gram-negative bacilli (from 5.3% in 2003-2004 to 8.2% in 2011-2012; p 0.032). The observed trends have important implications for the management of PJIs and prophylaxis in joint replacements.


Assuntos
Artrite Infecciosa/epidemiologia , Artrite Infecciosa/etiologia , Infecções Relacionadas à Prótese/epidemiologia , Infecções Relacionadas à Prótese/etiologia , Idoso , Idoso de 80 Anos ou mais , Antibacterianos/farmacologia , Artrite Infecciosa/história , Artroplastia/efeitos adversos , Bactérias/efeitos dos fármacos , Estudos de Coortes , Comorbidade , Farmacorresistência Bacteriana , Feminino , Fungos/efeitos dos fármacos , História do Século XXI , Humanos , Masculino , Pessoa de Meia-Idade , Infecções Relacionadas à Prótese/história , Espanha/epidemiologia
9.
Clin Microbiol Infect ; 20(11): O911-9, 2014 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-24766536

RESUMO

We aim to evaluate the epidemiology and outcome of gram-negative prosthetic joint infection (GN-PJI) treated with debridement, antibiotics and implant retention (DAIR), identify factors predictive of failure, and determine the impact of ciprofloxacin use on prognosis. We performed a retrospective, multicentre, observational study of GN-PJI diagnosed from 2003 through to 2010 in 16 Spanish hospitals. We define failure as persistence or reappearance of the inflammatory joint signs during follow-up, leading to unplanned surgery or repeat debridement>30 days from the index surgery related death, or suppressive antimicrobial therapy. Parameters predicting failure were analysed with a Cox regression model. A total of 242 patients (33% men; median age 76 years, interquartile range (IQR) 68-81) with 242 episodes of GN-PJI were studied. The implants included 150 (62%) hip, 85 (35%) knee, five (2%) shoulder and two (1%) elbow prostheses. There were 189 (78%) acute infections. Causative microorganisms were Enterobacteriaceae in 78%, Pseudomonas spp. in 20%, and other gram-negative bacilli in 2%. Overall, 19% of isolates were ciprofloxacin resistant. DAIR was used in 174 (72%) cases, with an overall success rate of 68%, which increased to 79% after a median of 25 months' follow-up in ciprofloxacin-susceptible GN-PJIs treated with ciprofloxacin. Ciprofloxacin treatment exhibited an independent protective effect (adjusted hazard ratio (aHR) 0.23; 95% CI, 0.13-0.40; p<0.001), whereas chronic renal impairment predicted failure (aHR, 2.56; 95% CI, 1.14-5.77; p 0.0232). Our results confirm a 79% success rate in ciprofloxacin-susceptible GN-PJI treated with debridement, ciprofloxacin and implant retention. New therapeutic strategies are needed for ciprofloxacin-resistant PJI.


Assuntos
Antibacterianos/uso terapêutico , Artrite/terapia , Desbridamento , Infecções por Bactérias Gram-Negativas/terapia , Retenção da Prótese , Infecções Relacionadas à Prótese/terapia , Idoso , Idoso de 80 Anos ou mais , Ciprofloxacina/uso terapêutico , Feminino , Humanos , Masculino , Estudos Retrospectivos , Espanha , Resultado do Tratamento
10.
Clin EEG Neurosci ; 35(2): 100-3, 2004 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-15164819

RESUMO

We describe the case of an 84-year-old woman who developed a confusional state and suffered from a generalized tonic-clonic seizure while she was treated with imipenem, a beta-lactam antibiotic. Focal and generalized epileptiform discharges and a photoparoxysmal response were prominent with transient changes on the EEG.


Assuntos
Eletroencefalografia , Epilepsia Tônico-Clônica/diagnóstico , Epilepsia Tônico-Clônica/etiologia , Imipenem/efeitos adversos , Imipenem/uso terapêutico , Infecções Urinárias/tratamento farmacológico , Infecções por Acinetobacter/sangue , Infecções por Acinetobacter/tratamento farmacológico , Idoso , Idoso de 80 Anos ou mais , Antibacterianos/efeitos adversos , Antibacterianos/uso terapêutico , Epilepsia Tônico-Clônica/sangue , Feminino , Humanos , Infecções Estafilocócicas/sangue , Infecções Estafilocócicas/tratamento farmacológico , Infecções Urinárias/sangue
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA