Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 19 de 19
Filtrar
1.
Artigo em Inglês | MEDLINE | ID: mdl-38521346

RESUMO

Epithelial ingrowth is one of the most significant complications of Laser in Situ Keratomileusis (LASIK) refractive surgery. We present the case of a 72-year-old male with a history of myopic LASIK (1999), who underwent cataract surgery and a second thin LASIK sub-Bowman flap to correct refractive error. Then, three months after pars plana vitrectomy for an epiretinal membrane, the patient complained of progressive vision loss. A diffuse haze of the corneal stroma that did not exist before surgery was observed. As the main suspicion was epithelial ingrowth, the flap was lifted and meticulous de-epithelialization of the stromal bed was performed. Mitomycin C 0.02% was applied, the flap was sutured with 10-0 Nylon, and a bandage contact lens was placed. The epithelialization of the interface after vitrectomy in a patient with LASIK could occur even when it is a rare complication and without obvious flap traumatism.

3.
Arch Soc Esp Oftalmol (Engl Ed) ; 99(1): 16-22, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-38008380

RESUMO

PURPOSE: To assess ciliary muscle (CM) and anterior scleral thickness (AST) dimensions in vivo in high myopia using swept-source optical coherence tomography (SS-OCT) and to compare with emmetropic and hyperopic subjects. METHODS: Cross-sectional study that included 34 high myopic patients (≥ -6 diopters [D]), 90 emmetropes (-1 to +1 D) and 38 hyperopic patients (≥ +3.5 D). CM thickness (CMT) and AST were measured in the temporal and nasal quadrants at 1, 2, and 3 mm from the scleral spur using SS-OCT. In addition, the length of the CM (CML) was evaluated. RESULTS: The dimensions of the CML and the CMT at any of their measurement points were greater in high myopes and emmetropes than in hyperopes, both in the nasal and temporal quadrants (P < .001). However, there were no differences between high myopes and emmetropes for any of the parameters (P ≥ .076) except for the CMT at 3 mm in the temporal quadrant (P < .001). There were no differences in the AST between high myopes, emmetropes and hyperopes, in any of the measurement points or quadrants studied (P > .05). CONCLUSIONS: The SS-OCT allows to measure the CM in vivo, not observing differences in its dimensions between high myopes and emmetropes, but they were smaller in hyperopes. In the measurement of the anterior sclera, no differences were observed between the three groups analyzed according to refraction.


Assuntos
Hiperopia , Miopia , Humanos , Tomografia de Coerência Óptica/métodos , Esclera/diagnóstico por imagem , Estudos Transversais , Miopia/diagnóstico por imagem , Músculos
6.
Arch Soc Esp Oftalmol (Engl Ed) ; 98(8): 434-439, 2023 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-37364677

RESUMO

PURPOSE: To study the biometric modifications of the eyeball during suction in Laser assisted in Situ Keratomileusis (LASIK). METHODS: Observational and cross-sectional study. We studied 43 patients who underwent surgery for myopia and myopic astigmatism. Mean age was 38.3 ±â€¯11.5 years, and 19 were female (44.2%). Conventional LASIK surgery with a manual microkeratome was performed. Before and during the suction maneuvre the following parameters were measured using an 11 Mhz biometric probe: aqueous depth (AQD), lens thickness (LT), vitreous cavity length (VCL) and axial length (AXL). Paired t-test was used to compare the biometric measurements before and during suction. RESULTS: The mean spherical equivalent refractive error was -4.5 ±â€¯2.3 diopters. During suction, the AQD did not change significantly (p = 0.231). However, AXL and VCL increased by 0.12 mm and 0.22 mm respectively (p = 0.039 and <0.01) and LT decreased by 0.20 mm (p < 0.01). AXL increased in 42% of the eyes and decreased in 16%, VCL increased in 70% of the eyes and decreased in 9%, and the LT was reduced in 67% of the eyes. CONCLUSIONS: Suction maneuvres during LASIK surgery produce changes of little magnitude in the eye globe, mainly a decrease in LT and an increase in VCL and AXL. Therefore, these modifications are expected to produce minimal anatomic alterations.


Assuntos
Ceratomileuse Assistida por Excimer Laser In Situ , Miopia , Humanos , Feminino , Adulto , Pessoa de Meia-Idade , Masculino , Sucção , Estudos Transversais , Miopia/cirurgia , Biometria
7.
Arch Soc Esp Oftalmol (Engl Ed) ; 98(9): 493-506, 2023 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-37369324

RESUMO

The glistening in intraocular lenses (IOLs) is a phenomenon in which tiny water-filled microvacuoles (MVs) form within the IOL material, causing light to scatter and create a sparkling or shimmering effect. The presence of glistening is common in many types of IOL materials and models and has been extensively studied in recent years to determine its incidence, risk factors, evolution, and possible clinical relevance. Classically, it has been studied in vitro in the laboratory or by means of photography obtained with a slit lamp, but these were techniques that required either specific technology or an expert explorer, complex image processing, and required a lot of time. In recent years, proposals based on the Scheimpflug camera and optical coherence tomography have emerged to try to simplify the analysis of glistening in IOLs. It has been described that the manufacturing process, the hydrophobic acrylic material, or the time since surgery are risk factors for the appearance of glistening. In addition, many issues related to this phenomenon are still unknown, such as not knowing from what number of points or their size they may have relevance to visual function since different optical phenomena related to glistening have been described on the IOLs.


Assuntos
Lentes Intraoculares , Lentes Intraoculares/efeitos adversos , Relevância Clínica , Processamento de Imagem Assistida por Computador
9.
J Fr Ophtalmol ; 44(9): 1370-1380, 2021 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-34330550

RESUMO

PURPOSE: To evaluate the agreement between Scheimpflug tomography (Pentacam, Oculus) and anterior segment optical coherence tomography (AS-OCT, RTVue 100, Optovue) as well as the reproducibility of each technique in assessing the lens-ICL distance (vault) after implantable collamer lens (ICL) implantation. METHODS: The vault was measured manually with Scheimpflug tomography and AS-OCT. Intraclass correlation coefficients (ICC) and Bland-Altman plots were used to determine the reproducibility of measurements and the agreement between them. Multivariate regression analysis was performed to identify predictors of differences in vault measurements between devices. RESULTS: 80 eyes of 46 ICL patients were analyzed. Mean patient age was 33.8±7.4 years (range, 21 to 51), and 27 (59%) were women. The preoperative spherical equivalent refraction ranged from -26 to 8.5 diopters (D). The mean vault measured by AS-OCT was 558.8±240.2µm (range, 162 - 1220) vs. 430.1±215.3µm (range, 0 to 1070) by Pentacam. AS-OCT yielded vault values, on average, 128.1±64.6µm higher than the Pentacam (range, -22 to 293µm). The ICC values for consistency and absolute agreement were 0.960 and 0.928, respectively. Reproducibility of vault measurements was excellent for both devices (ICC≥0.946). Four parameters-vault, pupil diameter (PD), PD differences between devices, and preoperative spherical equivalent refraction-were significant predictors of differences in vault measurements (adjusted-R2=0.412; P<0.001). CONCLUSIONS: Agreement between AS-OCT and Pentacam for vault measurement was good. Vaults were higher when measured by AS-OCT. These differences are clinically relevant, and therefore these devices cannot be used interchangeably to measure vault.


Assuntos
Lentes Intraoculares Fácicas , Adulto , Feminino , Humanos , Implante de Lente Intraocular , Pessoa de Meia-Idade , Refração Ocular , Reprodutibilidade dos Testes , Tomografia de Coerência Óptica , Adulto Jovem
11.
Arch Soc Esp Oftalmol (Engl Ed) ; 95(6): 271-278, 2020 Jun.
Artigo em Inglês, Espanhol | MEDLINE | ID: mdl-32423628

RESUMO

INTRODUCTION: To assess if there are any differences in macular and papillary thickness using optical coherence tomography (OCT) in patients with attention deficit hyperactivity disorder (ADHD) compared with a control group, including if there are differences between ADHD patients with and without treatment. METHODS: Prospective observational study including 92 eyes of 46 patients divided into 2 groups: 46 eyes of 23 patients with ADHD, and a control group of 46 eyes of 23 healthy patients. The group of patients with ADHD was subdivided into those on treatment with methylphenidate (n=28) and those not on treatment (n=18). The macular thickness, the ganglion cell complex (GCC), and the retinal nerve fibre layer (RNFL) at the papillary level were measured in 12 sectors. RESULTS: A lower central macular thickness was observed in the ADHD patients than in the controls (257.4±20µm versus 267.5±20µm, P=.013), with no differences observed in the GCC (P=.566), or in the RNFL (P=.095). There were no differences in the patients with ADHD with and without treatment, as regards macular thickness and the GCC (P=.160 and P=.375 respectively), but a lower foveal thickness (P=.018) and RNFL in 5/12 sectors at the papillary level (P=.033) were observed in those without treatment. CONCLUSIONS: A lower macular thickness was observed in patients with ADHD than in controls. In addition, patients with ADHD without treatment had a lower thickness of the fovea and RNFL than those patients on treatment.


Assuntos
Transtorno do Deficit de Atenção com Hiperatividade/tratamento farmacológico , Estimulantes do Sistema Nervoso Central/farmacologia , Estimulantes do Sistema Nervoso Central/uso terapêutico , Macula Lutea/efeitos dos fármacos , Macula Lutea/diagnóstico por imagem , Metilfenidato/farmacologia , Metilfenidato/uso terapêutico , Disco Óptico/efeitos dos fármacos , Disco Óptico/diagnóstico por imagem , Tomografia de Coerência Óptica , Adolescente , Criança , Estudos Transversais , Humanos , Macula Lutea/patologia , Disco Óptico/patologia , Tamanho do Órgão , Estudos Prospectivos
12.
J Fr Ophtalmol ; 43(1): 25-30, 2020 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-31733916

RESUMO

PURPOSE: To assess the correlation between optic nerve head measurements generated by Fourier-domain (FD) and swept-source (SS) optical coherence tomography (OCT) both in healthy Caucasian subjects and patients with primary open angle glaucoma (POAG). MATERIALS AND METHODS: This was a cross-sectional study of the right eyes of 118 subjects. In each participant, the measurements of disc area, cup to disc ratio (CDR), vertical cup to disc ratio (VCDR), rim area and rim volume were performed consecutively by FD-OCT and then SS-OCT. Participant age, gender and spherical equivalent were also recorded. Agreement between the two devices was assessed through intraclass correlation coefficients (ICC) and Bland-Altman plots. RESULTS: The study sample consisted of 95 healthy eyes and 23 eyes with glaucoma. Mean participant age was 48.6±20.0 years, 54.2% were female, and mean spherical equivalent was -1.6±3.0 diopters. FD-OCT and SS-OCT measurements were respectively: mean disc area 1.79±0.3 vs 1.83±0.3 mm2 (ICC=0.71), mean CDR 0.38±0.2 vs 0.33±0.2 (ICC=0.91), mean VCDR 0.58±0.2 vs 0.52±0.2 (ICC=0.92), mean rim area 1.05±0.4mm2 vs 1.03±0.5mm2 (ICC=0.29), and mean rim volume 0.14±0.11 vs 0.21±0.17mm3 (ICC=0.53). Good agreement between the devices was noted for rim area and rim volume in glaucoma subjects (ICC=0.76 and 0.68 respectively), while weak agreement was observed for these variables in healthy subjects (ICC≤0.50). CONCLUSIONS: The CDR and VCDR measurements provided by FD and SS OCT showed excellent agreement for the overall sample. When the devices were used for rim measurements, agreement was excellent only in the POAG patients.


Assuntos
Glaucoma/diagnóstico , Disco Óptico/diagnóstico por imagem , Disco Óptico/patologia , Tomografia de Coerência Óptica/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Estudos de Casos e Controles , Estudos Transversais , Feminino , Glaucoma/patologia , Humanos , Masculino , Pessoa de Meia-Idade , Doenças do Nervo Óptico/diagnóstico , Doenças do Nervo Óptico/patologia , Tamanho do Órgão , Reprodutibilidade dos Testes , Adulto Jovem
13.
Arch Soc Esp Oftalmol (Engl Ed) ; 94(10): 478-490, 2019 Oct.
Artigo em Inglês, Espanhol | MEDLINE | ID: mdl-31371112

RESUMO

The iridocorneal angle, due to its implications in the physiopathology of aqueous humour drainage, is a fundamental structure of the anterior chamber. Anterior segment optical coherence tomography is a rapid and non-invasive technique that obtains images in vivo. The high resolution allows it to analyse the normal anatomy of the angle, any alterations, and the changes that occur after different therapeutic interventions. Anterior segment optical coherence tomography technology has evolved to provide images that allow the identification and quantification of the angular structures in healthy subjects and in glaucoma patients, and especially the trabecular meshwork and the Schlemm's canal. It also enables the angle width to be quantified, with some objective parameters that have been standardised in recent years, such as the trabecular-iris angle, the angle opening distance, and the trabecular-iris area. This technique has multiple uses in the study of the different mechanisms of angle closure, the evaluation of changes after a laser peripheral iridotomy or iridoplasty after cataract surgery, as well as after the implantation of phakic lenses.


Assuntos
Córnea/diagnóstico por imagem , Iris/diagnóstico por imagem , Tomografia de Coerência Óptica , Humanos
16.
J Fr Ophtalmol ; 41(1): 14-20, 2018 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-29295793

RESUMO

PURPOSE: To analyze the agreement between Pentacam and optical coherence tomography (OCT) in the assessment of trabecular-iris angle (TIA) width in a large population of normal subjects. METHODS: A cross-sectional study was performed in 989 right eyes of 989 healthy subjects. The trabecular-iris angle (TIA) was measured in the temporal and nasal quadrants using the Pentacam (Oculus, Wetzlar, Germany), a device based on Scheimpflug technology and RTVue 100 OCT (Optovue, Fremont, CA, USA). Intraclass correlation coefficients (ICC) and Bland-Altman plots were used to evaluate agreement between these devices. RESULTS: Mean age was 49.1±15.2 years (18-84); 61% were women and spherical error range was -14 to 8.25. TIA could be measured by OCT in 94.9% and 94.1% in the temporal and nasal quadrants, with a mean value of 35.8±13.2 degrees (2.5-78.7) and 35.7±12.9 degrees (2.2-76.8) respectively. TIA was able to be measured by Pentacam in 95.2% and 95% in the temporal and nasal quadrants and means were 35.7±7.3 degrees (11-74.2) and 36.4±8.2 degrees (14.5-64) respectively. An ICC of 0.378 (95% confidence interval [CI], 0.322-0.431) and 0.589 (95% CI 0.546-0.629) for the temporal and nasal quadrants was obtained, showing moderate agreement between the devices. Bland-Altman plots revealed that, compared with OCT, Pentacam tends to overestimate measurements in narrow angles and underestimate these in open angles. CONCLUSIONS: Agreement between OCT and Pentacam was mediocre, indicating the two devices are not interchangeable when used to measure angle width.


Assuntos
Câmara Anterior/diagnóstico por imagem , Técnicas de Diagnóstico Oftalmológico , Iris/diagnóstico por imagem , Tomografia de Coerência Óptica , Malha Trabecular/diagnóstico por imagem , Adolescente , Adulto , Estudos Transversais , Técnicas de Diagnóstico Oftalmológico/instrumentação , Feminino , Glaucoma/diagnóstico , Voluntários Saudáveis , Humanos , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Tomografia de Coerência Óptica/instrumentação , Tomografia de Coerência Óptica/métodos , Gravação em Vídeo/instrumentação , Gravação em Vídeo/métodos , Adulto Jovem
17.
Arch Soc Esp Oftalmol (Engl Ed) ; 93(2): 53-59, 2018 Feb.
Artigo em Inglês, Espanhol | MEDLINE | ID: mdl-28743412

RESUMO

OBJECTIVE: To evaluate different anterior segment parameters in eyes with pseudoexfoliation (PSX), fellow eyes, and controls using optical coherence tomography and a Scheimpflug imaging system. METHODS: Three groups were studied: 44 eyes of 44 patients with PSX, 30 clinically unaffected fellow eyes, and 148 eyes of 148 healthy controls. The anterior chamber depth and volume, corneal volume and thickness, pupil diameter and corneal densitometry were measured using a Scheimpflug imaging system (Pentacam, Oculus Inc.; Wetzlar, Germany). The angle width, the length and area of the trabecular meshwork, and the iris thickness were measured using an optical coherence tomography RTVue 100 device (Optovue, Fremont, CA, USA). The presence of PSX deposits was also assessed by OCT. RESULTS: There were no differences in the anterior chamber volume or depth in the corneal volume or central thickness (P≥.228). The corneal densitometry was similar between PSX and fellow eyes; however it was greater than in the control group (P<.001). As regards the parameters measured by OCT, there were no differences in the angle width or in the trabecular meshwork size between the 3 groups; however, the iris was thinner in controls (P=.005). In all patients the PSX deposits were correctly visualised by OCT after the identification by biomicroscopy. CONCLUSIONS: There were no differences in the anterior segment biometric measurements between patients with PSX and controls, although the corneal densitometry and iris thickness were greater in the PSX and fellow eyes groups.


Assuntos
Segmento Anterior do Olho/diagnóstico por imagem , Síndrome de Exfoliação/diagnóstico por imagem , Tomografia de Coerência Óptica , Idoso , Estudos Transversais , Técnicas de Diagnóstico Oftalmológico/instrumentação , Feminino , Humanos , Masculino
19.
Arch Soc Esp Oftalmol ; 91(2): 74-80, 2016 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-26652971

RESUMO

OBJECTIVE: To study the structures of the iridocorneal angle using anterior segment optical coherence tomography (OCT) defining their tomographic characteristics and quantifying their identification frequency. MATERIAL AND METHODS: A cross-sectional study was performed on 267 right eyes of 267 consecutive healthy patients. Fourier domain OCT RTVue (Optovue Inc, CA, EE. UU.) was used to examine the iridocorneal angle in the nasal and temporal sectors. The structures evaluated were: Sclerocorneal limbus, sclerocorneal transition, Schwalbe's line, trabecular meshwork, Schlemm's canal, scleral spur, and angular recess. Within and between agreements to identify structures were calculated using Cohen's kappa coefficient. RESULTS: The mean age was 41.3 ± 14.3 years (range 20-80), with 57% being women. The sclerocorneal limbus, sclerocorneal transition, and Schwalbe's line were identified by 98.7, 97 and 93.4% of the images, respectively, with the trabecular meshwork and Schlemm's canal being identified in 91% of cases. The scleral spur could be identified in 85.4%, and the angular recess in 74.5%. There was no difference in the identification between the temporal and nasal sectors. Within and between agreement was k=0.92 and k=0.88, respectively, in the identification of the structures of the total images studied. CONCLUSIONS: Fourier domain OCT is a reliable technique for the identification of the structures of the iridocorneal angle, among which can be highlighted are, the trabecular meshwork, Schlemm's canal, scleral spur, and Schwalbe's line.


Assuntos
Câmara Anterior , Tomografia de Coerência Óptica , Malha Trabecular , Adulto , Idoso , Idoso de 80 Anos ou mais , Estudos Transversais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Esclera , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA