Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 178
Filtrar
1.
Rev Bras Ortop (Sao Paulo) ; 59(Suppl 1): e68-e72, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-39027190

RESUMO

Fractures of the odontoid apophysis are one of the most frequent lesions in the elderly population, and an increasingly preponderant problem with the progressive aging of the world population. In the present work, we report a clinical case of an 88-year-old male patient who suffered a fall resulting in a type-II fracture of the odontoid apophysis on the Anderson-D'Alonzo classification. Given the age and comorbidities of the patient, we decided to perform osteosynthesis of the fracture through anterior fixation with a transarticular screw in combination with fixation with an odontoid screw. This technique enables the necessary stability for the consolidation of Anderson-D'Alonzo's type II odontoid apophysis fracture, with the advantage of the lower levels of dissection of the cervical extensor musculature and hemorrhage resulting from this aggression when compared with the posterior approach; moreover, it is a readily-available technique that yields clear benefits in the treatment of this pathology in the geriatric population.

2.
J Hand Microsurg ; 16(2): 100044, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38855511

RESUMO

Objective: Approximately 68% of orthopaedic surgeons report occupational related musculoskeletal pain, with back pain being the most common. Poor posture while operating has been proven to contribute to these high rates of musculoskeletal pain. There is little research regarding intraoperative surgeon posture within the field of hand and upper extremity surgery. This prospective study aims to investigate and analyze hand surgeon posture in the operating room. Methods: Posture of three hand surgeons was recorded using the UPRIGHT GO posture tracking device while performing a prospective series of 223 hand and upper extremity surgeries. This device reports posture in terms of overall percentage of time spent slouched versus upright. For this cohort of 223 cases, data were collected including surgical procedure, whether the surgery was performed in a seated or standing position, whether or not loupes were worn during the procedure, and if the surgeon was the primary or assistant surgeon. These data were then analyzed to look for any contributing factors to poor posture. Results: The three hand surgeons in this study spent an average of 40.3% of their time slouched while operating. The average percentage of time slouched was significantly greater with the use of loupes versus no loupes. Additionally, mean time slouching was slightly increased when the surgeon was seated and also when the surgeon was acting as the assistant surgeon. Conclusion: The three orthopaedic hand surgeons in our study spent a significant portion of their operative time slouched. The main variable associated with a significant risk of poor surgical posture was wearing loupes. Slight increases in slouching were seen with operating while seated and as the assistant surgeon. Surgeon awareness of these variables, as well as techniques to improve surgeon posture, should be developed in order to help contribute to better surgeon posture within the field of hand surgery.

3.
Biomater Sci ; 12(12): 3124-3140, 2024 Jun 11.
Artigo em Inglês | MEDLINE | ID: mdl-38738995

RESUMO

Synthetic tubular grafts currently used in clinical context fail frequently, and the expectations that biomimetic materials could tackle these limitations are high. However, developing tubular materials presenting structural, compositional and functional properties close to those of native tissues remains an unmet challenge. Here we describe a combination of ice templating and topotactic fibrillogenesis of type I collagen, the main component of tissues' extracellular matrix, yielding highly concentrated yet porous tubular collagen materials with controlled hierarchical architecture at multiple length scales, the hallmark of native tissues' organization. By modulating the thermal conductivity of the cylindrical molds, we tune the macroscopic porosity defined by ice. Coupling the aforementioned porosity patterns with two different fibrillogenesis routes results in a new family of tubular materials whose textural features and the supramolecular arrangement of type I collagen are achieved. The resulting materials present hierarchical elastic properties and are successfully colonized by human endothelial cells and alveolar epithelial cells on the luminal side, and by human mesenchymal stem cells on the external side. The proposed straightforward protocol is likely to be adapted for larger graft sizes that address ever-growing clinical needs, such as peripheral arterial disease or tracheal and bronchial reconstructions.


Assuntos
Materiais Biomiméticos , Gelo , Engenharia Tecidual , Humanos , Materiais Biomiméticos/química , Porosidade , Células-Tronco Mesenquimais/citologia , Colágeno Tipo I/química , Animais
4.
Materials (Basel) ; 17(10)2024 May 15.
Artigo em Inglês | MEDLINE | ID: mdl-38793413

RESUMO

The resistance of nickel-titanium endodontic instruments against cyclic fatigue failure remains a significant concern in clinical settings. This study aimed to assess the cyclic fatigue strength of five nickel-titanium rotary systems, while correlating the results with the instruments' geometric and metallurgical characteristics. A total of 250 new instruments (sizes S1/A1, S2/A2, F1/B1, F2/B2, F3/B3) from ProTaper Gold, ProTaper Universal, Premium Taper Gold, Go-Taper Flex, and U-Files systems underwent mechanical testing. Prior to experimental procedures, all instruments were meticulously inspected to identify irregularities that could affect the investigation. Using a stereomicroscope, design characteristics such as the number of spirals, length, spirals per millimeter, and average helical angle of the active blade were determined. The surface finishing characteristics of the instruments were examined using a scanning electron microscope. Differential scanning calorimetry was employed to establish the instruments' phase transformation temperatures, while energy-dispersive X-ray spectroscopy was utilized to analyze the elemental composition of the alloy. The instruments were subjected to cyclic fatigue testing within a stainless steel non-tapered artificial canal featuring a 6 mm radius and 86 degrees of curvature. Appropriate statistical tests were applied to compare groups, considering a significance level of 0.05. The assessed design characteristics varied depending on the instrument type. The least irregular surface finishing was observed in U-Files and Premium Taper Gold files, while the most irregular surface was noted in Go-Taper Flex. All instruments exhibited near-equiatomic proportions of nickel and titanium elements, whereas ProTaper Universal and U-Files instruments demonstrated lower phase transformation temperatures compared to their counterparts. Larger-sized instruments, as well as ProTaper Universal and U-Files, tended to display lower cyclic fatigue strength results. Overall, the design, metallurgical, and cyclic fatigue outcomes varied among instruments and systems. Understanding these outcomes may assist clinicians in making more informed decisions regarding instrument selection.

5.
Int Endod J ; 57(5): 601-616, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38376108

RESUMO

AIM: To compare eight large- and low-tapered heat-treated reciprocating instruments regarding their design, metallurgy, mechanical properties, and irrigation flow through an in silico model. METHODOLOGY: A total of 472 new 25-mm E-Flex Rex (25/.04 and 25/.06), Excalibur (25/.05), Procodile (25/.06), Reciproc Blue R25 (25/.08v), WaveOne Gold Primary (25/.07v), and Univy Sense (25/.04 and 25/.06) instruments were evaluated regarding their design (stereomicroscopy, scanning electron microscopy, and 3D surface scanning), metallurgy (energy-dispersive X-ray spectroscopy and differential scanning calorimetry), and mechanical performance (cyclic fatigue, torsional resistance, cutting ability, bending and buckling resistance). Computational fluid dynamics assessment was also conducted to determine the irrigation flow pattern, apical pressure, and wall shear stress in simulated canal preparations. Kruskal-Wallis and one-way anova post hoc Tukey tests were used for statistical comparisons (α = 5%). RESULTS: Instruments presented variations in blade numbers, helical angles, and tip designs, with all featuring non-active tips, symmetrical blades, and equiatomic nickel-titanium ratios. Cross-sectional designs exhibited an S-shaped geometry, except for WaveOne Gold. Univy 25/.04 and Reciproc Blue displayed the smallest and largest core diameters at D3. Univy 25/.04 and E-Flex Rec 25/.04 demonstrated the longest time to fracture (p < .05). Reciproc Blue and Univy 25/.04 exhibited the highest and lowest torque to fracture, respectively (p < .05). Univy 25/.04 and Reciproc Blue had the highest rotation angles, whilst E-Flex Rec 25/.06 showed the lowest angle (p < .05). The better cutting ability was observed with E-Flex Rec 25/.06, Procodile, Excalibur, and Reciproc Blue (p > .05). Reciproc R25 and E-Flex Rec showed the highest buckling resistance values (p < .05), with WaveOne Gold being the least flexible instrument. The impact of instruments' size and taper on wall shear stress and apical pressure did not follow a distinct pattern, although Univy 25/.04 and E-Flex Rec 25/.06 yielded the highest and lowest values for both parameters, respectively. CONCLUSIONS: Low-tapered reciprocating instruments exhibit increased flexibility, higher time to fracture, and greater angles of rotation, coupled with reduced maximum bending loads and buckling strength compared to large-tapered instruments. Nevertheless, low-tapered systems also exhibit lower maximum torque to fracture and inferior cutting ability, contributing to a narrower apical canal enlargement that may compromise the penetration of irrigants in that region.


Assuntos
Instrumentos Odontológicos , Titânio , Estudos Transversais , Desenho de Equipamento , Teste de Materiais , Estresse Mecânico , Titânio/química , Preparo de Canal Radicular , Metalurgia
6.
Brain Topogr ; 2024 Jan 23.
Artigo em Inglês | MEDLINE | ID: mdl-38261272

RESUMO

Several studies have shown that mouth movements related to the pronunciation of individual phonemes are represented in the sensorimotor cortex. This would theoretically allow for brain computer interfaces that are capable of decoding continuous speech by training classifiers based on the activity in the sensorimotor cortex related to the production of individual phonemes. To address this, we investigated the decodability of trials with individual and paired phonemes (pronounced consecutively with one second interval) using activity in the sensorimotor cortex. Fifteen participants pronounced 3 different phonemes and 3 combinations of two of the same phonemes in a 7T functional MRI experiment. We confirmed that support vector machine (SVM) classification of single and paired phonemes was possible. Importantly, by combining classifiers trained on single phonemes, we were able to classify paired phonemes with an accuracy of 53% (33% chance level), demonstrating that activity of isolated phonemes is present and distinguishable in combined phonemes. A SVM searchlight analysis showed that the phoneme representations are widely distributed in the ventral sensorimotor cortex. These findings provide insights about the neural representations of single and paired phonemes. Furthermore, it supports the notion that speech BCI may be feasible based on machine learning algorithms trained on individual phonemes using intracranial electrode grids.

7.
Ann Hum Biol ; 51(1): 1-12, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38267407

RESUMO

BACKGROUND: Motor performances of youth are related to growth and maturity status, among other factors. AIM: To estimate the contribution of skeletal maturity status per se to the motor performances of female athletes aged 10-15 years and the mediation effects of growth status on the relationships. SUBJECTS AND METHODS: Skeletal age (TW3 RUS SA), body size, proportions, estimated fat-free mass (FFM), motor performances, training history and participation motivation were assessed in 80 non-skeletally mature female participants in several sports. Hierarchical and regression-based statistical mediation analyses were used. RESULTS: SA per se explained a maximum of 1.8% and 5.8% of the variance in motor performances of athletes aged 10-12 and 13-15 years, respectively, over and above that explained by covariates. Body size, proportions, and hours per week of training and participation motivation explained, respectively, a maximum of 40.7%, 18.8%, and 22.6% of the variance in performances. Mediation analysis indicated specific indirect effects of SA through stature and body mass, alone or in conjunction with FFM on performances. CONCLUSION: SA per se accounted for small and non-significant amounts of variance in several motor performances of female youth athletes; rather, SA influenced performances indirectly through effects on stature, body mass and estimated FFM.


Assuntos
Determinação da Idade pelo Esqueleto , Esportes , Adolescente , Feminino , Humanos , Criança , Tamanho Corporal , Atletas , Estatura
8.
Pediatr Res ; 95(6): 1625-1633, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38225449

RESUMO

BACKGROUND: Pain is a complex experience that interferes with the well-being of youth who experience it. We aimed to assess whether recurrent pain sites in childhood can predict later recurrent pain sites prospectively. METHODS: Pain was assessed using the Luebeck Pain Screening Questionnaire at ages 7, 10, and 13 from the Generation XXI cohort. We used multinomial regression to assess the association of recurrent pain sites at ages 7 and 10 with those at age 13. RESULTS: We included 3833 participants. Boys with recurrent abdominal/pelvic pain at age 7 were more likely to report headaches (OR 2.81; 95%CI 1.48-5.34), abdominal/pelvic (OR 2.92; 95%CI 1.46-5.84), and musculoskeletal pain (OR 1.55; 95%CI 1.02-2.34) at age 13. Girls with recurrent abdominal/pelvic pain at age 7 were more likely to report both musculoskeletal (OR 1.62; 95%CI 1.10-2.40) and abdominal/pelvic pain (OR 1.74; 95%CI 1.15-2.65). At age 10, all pain sites were associated with pain in the same site at age 13. CONCLUSION: Recurrent abdominal/pelvic pain at age 7 may be related to the development of various pains in adolescence. Pain at a given site at age 10 can be associated with pain at that same site at age 13. IMPACT: Recurrent abdominal or pelvic pain during childhood was distinctively associated with an increased risk of recurrent pain in other sites during adolescence. Recurrent pain during childhood was associated with pain in the same sites at age 13, and this persistence seemed to emerge between the ages of 7 and 10 for both boys and girls. Studying early pain sites may add to the understanding of the etiology of chronic pain.


Assuntos
Dor Abdominal , Recidiva , Humanos , Masculino , Feminino , Criança , Adolescente , Estudos Prospectivos , Dor Abdominal/etiologia , Inquéritos e Questionários , Dor Pélvica/etiologia , Dor Musculoesquelética , Medição da Dor , Cefaleia
9.
Eur J Pain ; 28(1): 70-82, 2024 01.
Artigo em Inglês | MEDLINE | ID: mdl-37485565

RESUMO

BACKGROUND: Sensitized pain mechanisms are often reported in musculoskeletal pain conditions, but population-based paediatric studies are lacking. We assessed whether adolescents with musculoskeletal pain history had evidence of increased responsiveness to experimental pressure stimuli. METHODS: Data were from 1496 adolescents of the Generation XXI birth cohort. Pain history was collected using the Luebeck Pain Questionnaire (self-reported at 13, parent-reported at 7 and 10 years). Two case definitions for musculoskeletal pain were considered: (1) cross-sectional-musculoskeletal pain lasting more than 3 months at age 13 and (2) longitudinal-musculoskeletal pain at age 13 with musculoskeletal pain reports at ages 7 and/or 10. Lower limb cuff pressure algometry was used to assess pain detection and tolerance thresholds, conditioned pain modulation effects (CPM, changes in thresholds in the presence on painful conditioning) and temporal summation of pain effects (TSP, changes in pain intensity to 10 phasic painful cuff stimulations). RESULTS: Adolescents with musculoskeletal pain at age 13 plus a history of pain in previous evaluations (longitudinal definition) had lower pain tolerance thresholds compared to the remaining sample (40.2 v. 49.0 kPa, p = 0.02), but showed no differences in pain detection threshold, CPM effect and TSP effect. Pain sensitivity, CPM effects and TSP effects were not significantly different when the current pain only case definition (cross-sectional) was used. CONCLUSIONS: Adolescents with current musculoskeletal pain who had a history of pain since childhood had lower tolerance to cuff stimulation. This may suggest long-standing musculoskeletal pain since childhood may contribute to sensitisation, rather than the presence of current pain only. SIGNIFICANCE: Repeated musculoskeletal pain up to age 13 years may contribute to higher pain sensitivity (particularly lowered pressure pain tolerance) in the general adolescent population. This does not seem to be the case when reported pain experiences are recent or when the outcomes are temporal pain summation or CPM. In this community-based paediatric sample, the vast majority showed no sign of altered pain processing, but a small fraction may reveal some pain sensitization at 13 years of age.


Assuntos
Dor Musculoesquelética , Humanos , Adolescente , Criança , Dor Musculoesquelética/epidemiologia , Dor Musculoesquelética/diagnóstico , Coorte de Nascimento , Estudos Transversais , Pressão , Limiar da Dor/fisiologia
10.
Int Endod J ; 56(11): 1412-1428, 2023 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-37698946

RESUMO

AIM: To compare the design, metallurgy, and mechanical properties of four heat-treated reciprocating instruments coupled with the evaluation of the irrigation flow using an in silico model. METHODOLOGY: New EdgeOne Fire Primary, Easy-File Flex Regular 25, WaveOne Gold Primary and Reciproc Blue R25 instruments (n = 124) were initially evaluated regarding their design through stereomicroscopy, scanning electron microscopy and 3D surface scanning. In addition, energy-dispersive X-ray spectroscopy was utilized to determine their elemental composition, and differential scanning calorimetry tests to evaluate their phase transformation temperatures. Their mechanical performance was further assessed through torsional and bending tests. Using scans obtained from a real tooth and the instruments, a computational fluid dynamics assessment was conducted to determine the irrigation flow pattern, apical pressure, and wall shear stress in simulated canal preparation. Mood's median and One-way anova post hoc Tukey tests were used for statistical comparisons (α = 5%). RESULTS: Reciproc Blue exhibited a superior number of blades (n = 8), whereas EdgeOne Fire had the highest overall volume (4.38 mm3 ) and surface area (32.32 mm2 ). At the 3-mm axial level, EdgeOne Fire displayed the lowest core diameter (0.13 mm), while Reciproc Blue had the highest (0.16 mm). All blades were symmetrical, and the tips of the instruments were non-active but differed from each other. The most irregular surfaces were observed in EdgeOne Fire and Easy-File Flex. All instruments were manufactured from nickel-titanium alloys and exhibited distinct phase transformation temperatures. WaveOne Gold and Reciproc Blue demonstrated the highest maximum torque values (1.87 and 1.62 N cm, respectively), while the lowest was observed on EdgeOne Fire (1.21 N cm) (p < .05). The most flexible (p < .05) were EdgeOne Fire (angle of rotation: 602.6°; maximum bending load: 251.4 g.f) and Reciproc Blue (533.2° and 235.6 g.f). There were no significant differences observed in the irrigation flow among the four domains generated by the tested instruments. CONCLUSIONS: Despite observing variations in the design, phase transformation temperatures, and in the torsional and bending test outcomes among the four heat-treated reciprocating instruments, no significant differences were found in the irrigation flow pattern among the different groups in the simulated root canal preparations.


Assuntos
Instrumentos Odontológicos , Temperatura Alta , Desenho de Equipamento , Estresse Mecânico , Preparo de Canal Radicular , Titânio/química , Metalurgia , Ouro , Teste de Materiais
11.
AoB Plants ; 15(4): plad057, 2023 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-37649982

RESUMO

Anagenetic speciation is an important mode of evolution in oceanic islands, yet relatively understudied compared to adaptive radiation. In the Macaronesian region, three closely related species of Artemisia (i.e. A. argentea, A. thuscula and A. gorgonum) are each endemic from a single archipelago (i.e. Madeira, Canary Islands and Cape Verde, respectively), representing a perfect opportunity to study three similar but independent anagenetic speciation processes. By analysing plastid and nuclear DNA sequences, as well as nuclear DNA amount data, generated from a comprehensive sampling in all the islands and archipelagos where these species are currently distributed, we intend to find common evolutionary patterns that help us explain the limited taxonomic diversification experienced by endemic Macaronesian Artemisia. Our time-calibrated phylogenetic reconstruction suggested that divergence among the three lineages occurred in a coincidental short period of time during the Pleistocene. Haplotype and genetic differentiation analyses showed similar diversity values among A. argentea, A. thuscula and A. gorgonum. Clear phylogeographic patterns-showing comparable genetic structuring among groups of islands-were also found within the three archipelagos. Even from the cytogenetic point of view, the three species presented similarly lower genome size values compared to the mainland closely related species A. arborescens. We hypothesize that the limited speciation experienced by the endemic Artemisia in Madeira, Canary Islands and Cape Verde archipelagos could be related to their recent parallel evolutionary histories as independent lineages, combined with certain shared characteristics of seed dispersal, pollen transport and type of habitat.

12.
Int Endod J ; 56(10): 1301-1315, 2023 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-37594701

RESUMO

AIM: To assess the influence of a flat-side design on the geometry, metallurgy, mechanical performance and shaping ability of a novel nickel-titanium rotary instrument. METHODOLOGY: Sixty-five new 25-mm flat-side rotary instruments (size 25, taper 0.04) and their nonflat-side prototypes (n = 65) were assessed for major deformations and examined regarding macroscopic and microscopic design, determination of nickel and titanium elements ratio, measurement of phase transformation temperature and evaluation of mechanical performance parameters including time/cycles to fracture, maximum torque, angle of rotation, maximum bending and buckling strengths and cutting ability. Additionally, unprepared canal areas, volume of hard tissue debris and percentage reduction of dentine thickness were calculated for each tested instrument after preparing mesial canals of mandibular molars (n = 12), using micro-CT imaging. Statistical analyses were performed using the U-Mann-Whitney test and independent Student t-test (α = 5%). RESULTS: The number of spirals (n = 8) and blade direction (clockwise) were similar between both flat and nonflat instruments, whilst the helical angles were equivalent (⁓25°). Flat-instruments showed inconsistencies in the homogeneity of the gold colour on the flat-side surface, blade discontinuity, and incomplete and variable S-shaped cross-sections. The titanium-to-nickel ratios were equivalent, but significant differences in the R-phase finish and austenitic start phase transformation temperatures were observed between the flat and nonflat-side instruments. The flat-side instruments demonstrated superior cutting ability compared to the nonflat instruments, as well as, significantly lower values for time to fracture, rotation to fracture and maximum torque to fracture (p < .001). No statistical difference was observed between tested instruments regarding angle of rotation (p = .437), maximum bending (p = .152) and buckling load (p = .411). Preparation protocols using flat and nonflat instruments did not show any statistically significant differences (p > .05). All flat-side instruments exhibited deformation after shaping procedures. CONCLUSIONS: The flat-side instrument showcased enhanced cutting ability compared to its nonflat counterpart. However, it exhibited inferior performance in terms of time, rotation and maximum torque to fracture, along with distinct phase transformation temperatures. No differences were observed in the titanium-to-nickel ratios, angle of rotation, maximum bending, buckling load, preparation time, percentage of untouched canal walls, volume of hard tissue debris and percentage reduction of dentine thickness.


Assuntos
Níquel , Titânio , Humanos , Cavidade Pulpar , Metalurgia , Dente Molar
13.
Int Endod J ; 56(7): 896-908, 2023 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-37029571

RESUMO

AIM: To compare two flat-side single-file rotary instruments with three single-file reciprocating systems through a multimethod assessment. METHODOLOGY: A total of 290 new NiTi single-file rotary (AF F One Blue 25/0.06 and Platinum V.EU 25/0.06) and reciprocating (One Files Blue R25, Reciproc Blue R25, Reciproc R25) instruments were selected, carefully examined for any major deformations, and evaluated regarding their macroscopic and microscopic design, nickel and titanium elements ratio, phase transformation temperatures, and mechanical performance (time/rotation to fracture, maximum torque, angle of rotation, microhardness, maximum bending, and buckling strengths). One-way anova post hoc Tukey, T-test, and nonparametric Mood's median tests were used for statistical comparisons (α = 5%). RESULTS: Tested instruments had identical blade counts and near-identical helical angles of approximately 24° (rotary instruments) and 151° (reciprocating instruments). The flat-side analysis revealed a few inconsistencies, such as discontinuity segments, different orientations, and gaps in the homogeneity of the bluish colour. Microscopically, flat-side instruments exhibited blade discontinuity and an incomplete S-shaped cross-section. The surface finish was smoother for One Files Blue and more irregular for both rotary instruments. There were distinct phase transformation temperatures amongst all instruments. All heat-treated instruments were in R-phase arrangement, and Reciproc was in R-phase plus austenite at test temperature (20°C). Compared with the reciprocating instruments, both flat-side instruments exhibited lower results in the cyclic fatigue tests using two different clockwise kinematics, maximum torque, angle of rotation, and maximum buckling strength (p < .05). The rotary systems also exhibited low flexibility (p < .05). AF F One Blue had the lowest microhardness, whilst Reciproc had the highest value. CONCLUSION: This multimethod investigation revealed that the flat-side rotary instruments underperformed the reciprocating instruments regarding cyclic fatigue (with two different clockwise kinematics), maximum torque, angle of rotation, maximum buckling strength, and flexibility. Manufacturing inconsistencies were also observed in some of the flat-side instruments, including discontinuity segments, different orientations, and in the homogeneity of their bluish colour given by the heat treatment.


Assuntos
Instrumentos Odontológicos , Temperatura Alta , Desenho de Equipamento , Preparo de Canal Radicular , Teste de Materiais , Titânio , Estresse Mecânico
14.
JMIR Public Health Surveill ; 9: e43836, 2023 04 06.
Artigo em Inglês | MEDLINE | ID: mdl-36877958

RESUMO

BACKGROUND: Contact tracing is a fundamental intervention in public health. When systematically applied, it enables the breaking of chains of transmission, which is important for controlling COVID-19 transmission. In theoretically perfect contact tracing, all new cases should occur among quarantined individuals, and an epidemic should vanish. However, the availability of resources influences the capacity to perform contact tracing. Therefore, it is necessary to estimate its effectiveness threshold. We propose that this effectiveness threshold may be indirectly estimated using the ratio of COVID-19 cases arising from quarantined high-risk contacts, where higher ratios indicate better control and, under a threshold, contact tracing may fail and other restrictions become necessary. OBJECTIVE: This study assessed the ratio of COVID-19 cases in high-risk contacts quarantined through contact tracing and its potential use as an ancillary pandemic control indicator. METHODS: We built a 6-compartment epidemiological model to emulate COVID-19 infection flow according to publicly available data from Portuguese authorities. Our model extended the usual susceptible-exposed-infected-recovered model by adding a compartment Q with individuals in mandated quarantine who could develop infection or return to the susceptible pool and a compartment P with individuals protected from infection because of vaccination. To model infection dynamics, data on SARS-CoV-2 infection risk (IR), time until infection, and vaccine efficacy were collected. Estimation was needed for vaccine data to reflect the timing of inoculation and booster efficacy. In total, 2 simulations were built: one adjusting for the presence and absence of variants or vaccination and another maximizing IR in quarantined individuals. Both simulations were based on a set of 100 unique parameterizations. The daily ratio of infected cases arising from high-risk contacts (q estimate) was calculated. A theoretical effectiveness threshold of contact tracing was defined for 14-day average q estimates based on the classification of COVID-19 daily cases according to the pandemic phases and was compared with the timing of population lockdowns in Portugal. A sensitivity analysis was performed to understand the relationship between different parameter values and the threshold obtained. RESULTS: An inverse relationship was found between the q estimate and daily cases in both simulations (correlations >0.70). The theoretical effectiveness thresholds for both simulations attained an alert phase positive predictive value of >70% and could have anticipated the need for additional measures in at least 4 days for the second and fourth lockdowns. Sensitivity analysis showed that only the IR and booster dose efficacy at inoculation significantly affected the q estimates. CONCLUSIONS: We demonstrated the impact of applying an effectiveness threshold for contact tracing on decision-making. Although only theoretical thresholds could be provided, their relationship with the number of confirmed cases and the prediction of pandemic phases shows the role as an indirect indicator of the efficacy of contact tracing.


Assuntos
COVID-19 , Humanos , COVID-19/epidemiologia , Busca de Comunicante , Controle de Doenças Transmissíveis , Pandemias/prevenção & controle , SARS-CoV-2
15.
J Environ Manage ; 336: 117594, 2023 Jun 15.
Artigo em Inglês | MEDLINE | ID: mdl-36907067

RESUMO

Understanding the effects of agroforestry systems (AFs) on soil organic carbon (SOC) requires long-term experiments, but scenarios simulations can anticipate the potential of these systems to sequester or lose carbon (C). This study aimed to simulate the SOC dynamics in slash and burn management (BURN) and AFs using the Century model. Data from a long-term experiment implemented in the Brazilian semiarid region were used to simulate SOC dynamics under BURN and AFs situations, and the natural vegetation (NV) "Caatinga" as a reference. BURN scenarios considered different fallow periods (0, 7, 15, 30, 50 and 100 years) among cultivation of the same area. The two types of AFs (agrosilvopastoral-AGP and silvopastoral-SILV) were simulated in two contrasting conditions: (i) each one of the AFs and also NV area were permanently conducted with no rotation among these areas; and (ii) the two AFs and NV rotated among them every 7 years. The correlation coefficients (r), coefficients of determination (CD) and coefficients of residual mass (CRM) showed adequate performance, meaning that the Century model is able to reproduce the SOC stocks in the slash and burn management and AFs situations. The equilibrium points of NV SOC stocks stabilized around 30.3 Mg ha-1, as similar to the measured average of 28.4 Mg ha-1 at field conditions. The adoption of BURN without a fallow period (0 years) resulted in a reduction of 50% of SOC, approximately 20 Mg ha-1, after the first 10 years. Permanent (p) and rotating (r) AFs management systems recovered (in 10 years) fast to the original SOC stocks, resulting in higher SOC stocks than NV SOC at equilibrium. The fallow period of 50 years is necessary to recovery SOC stocks in the Caatinga biome. The simulation shows that the AFs systems increase more SOC stocks than observed in natural vegetation in long-term.


Assuntos
Queimaduras , Solo , Humanos , Carbono , Ecossistema , Simulação por Computador , Sequestro de Carbono , Agricultura/métodos
16.
Int Endod J ; 56(6): 775-785, 2023 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-36942476

RESUMO

AIM: This study aimed to compare three rotary instruments produced by the EDM process with the heat-treated ProTaper Gold system regarding design, metallurgy, mechanical properties and shaping ability. METHODOLOGY: HyFlex EDM (25/~), Neoniti (25/.06), EDMax (25/.06) and ProTaper Gold (25/.08v) instruments (n = 58 per group) were compared regarding design, metallurgy and mechanical performance. Unprepared canal areas were calculated for each system after preparation of mesiobuccal, mesiolingual and distal canals of mandibular molars (15 canals per group) using micro-CT technology. Statistical analyses were performed using One-way anova post-hoc Tukey and Kruskal-Wallis post-hoc Dunn's tests (α = 5%). RESULTS: All instruments had asymmetrical blades, no radial lands, no major defects and almost equiatomic nickel/titanium ratios, but different cross-section designs, tip geometries and surface appearances. Although instruments had distinct transformation temperature curves, they showed crystallographic martensitic arrangement at 21°C and mixed austenite plus R-phase at body temperature. Neoniti and HyFlex EDM showed similar results in all mechanical tests (p > .05), while EDMax and ProTaper Gold had similar time to fracture (p = .841), maximum bending load (p = .729), and cutting ability (p = .985). ProTaper Gold showed the highest torque to failure (p < .001) and HyFlex EDM had the lowest buckling resistance (p < .001). Mean percentages of unprepared canal areas ranged from 20.4% to 25.7% in the mesial canals, and from 20.8% to 26.2% in the distal canal, with no statistical differences among systems (p > .05). CONCLUSIONS: Instruments' geometry and phase transformation temperatures influenced the results of the mechanical tests, but not their shaping ability.


Assuntos
Preparo de Canal Radicular , Humanos , Ligas Dentárias/química , Instrumentos Odontológicos , Desenho de Equipamento , Teste de Materiais , Temperatura , Titânio/química , Torque
17.
Clin Oral Investig ; 27(5): 2427-2436, 2023 May.
Artigo em Inglês | MEDLINE | ID: mdl-36749411

RESUMO

OBJECTIVE: This study aimed to compare 3 reciprocating systems regarding design, metallurgy, mechanical properties, and shaping ability. MATERIALS AND METHODS: New Reciproc Blue R25, WaveOne Gold Primary, and REX 25 instruments (n=41 per group) were analyzed regarding design, metallurgy, and mechanical performance, while shaping ability (untouched canal walls, volume of removed dentin, and hard tissue debris) was tested in 36 anatomically matched root canals of mandibular molars. Results were compared using one-way ANOVA post hoc Tukey and Kruskal-Wallis tests with a significant level set at 5%. RESULTS: All instruments showed symmetrical cross sections with asymmetrical blades, no radial lands, no major defects, and an almost equiatomic nickel and titanium ratio. The highest R-phase start temperatures were observed with WaveOne Gold (46.1°C) and REX (44.8°C), while Reciproc Blue had the lowest R-phase start (34.5°C) and finish (20°C) temperatures. WaveOne Gold had the lowest time to fracture (169 s) and the highest maximum load (301.6 gf) (P <0.05). The maximum torque of Reciproc Blue (2.2 N.cm) and WaveOne Gold (2.1 N.cm) were similar (P >0.05), but lower than REX (2.6 N.cm) (P <0.05). No statistical differences were observed among instruments in the angle of rotation (P >0.05) and in the shaping ability in both mesial and distal canals (P >0.05). CONCLUSION: Although the overall design, temperature transition phases and mechanical behavior parameters were different among tested instruments, they were similar in terms of shaping ability. CLINICAL RELEVANCE: All tested heat-treated NiTi reciprocating systems showed similar shaping ability, without clinically significant errors.


Assuntos
Temperatura Alta , Preparo de Canal Radicular , Instrumentos Odontológicos , Desenho de Equipamento , Titânio , Metalurgia , Teste de Materiais
18.
Hum Brain Mapp ; 44(5): 2050-2061, 2023 04 01.
Artigo em Inglês | MEDLINE | ID: mdl-36637226

RESUMO

Perception of dynamic scenes in our environment results from the evaluation of visual features such as the fundamental spatial and temporal frequency components of a moving object. The ratio between these two components represents the object's speed of motion. The human middle temporal cortex hMT+ has a crucial biological role in the direct encoding of object speed. However, the link between hMT+ speed encoding and the spatiotemporal frequency components of a moving object is still under explored. Here, we recorded high resolution 7T blood oxygen level-dependent BOLD responses to different visual motion stimuli as a function of their fundamental spatial and temporal frequency components. We fitted each hMT+ BOLD response with a 2D Gaussian model allowing for two different speed encoding mechanisms: (1) distinct and independent selectivity for the spatial and temporal frequencies of the visual motion stimuli; (2) pure tuning for the speed of motion. We show that both mechanisms occur but in different neuronal groups within hMT+, with the largest subregion of the complex showing separable tuning for the spatial and temporal frequency of the visual stimuli. Both mechanisms were highly reproducible within participants, reconciling single cell recordings from MT in animals that have showed both encoding mechanisms. Our findings confirm that a more complex process is involved in the perception of speed than initially thought and suggest that hMT+ plays a primary role in the evaluation of the spatial features of the moving visual input.


Assuntos
Percepção de Movimento , Animais , Humanos , Percepção de Movimento/fisiologia , Imageamento por Ressonância Magnética , Estimulação Luminosa/métodos , Lobo Temporal/diagnóstico por imagem , Lobo Temporal/fisiologia , Neurônios/fisiologia
19.
ACS Sens ; 8(2): 406-426, 2023 02 24.
Artigo em Inglês | MEDLINE | ID: mdl-36696289

RESUMO

Circulating tumor cells (CTCs) represent an interesting source of biomarkers for diagnosis, prognosis, and the prediction of cancer recurrence, yet while they are extensively studied in oncobiology research, their diagnostic utility has not yet been demonstrated and validated. Their scarcity in human biological fluids impedes the identification of dangerous CTC subpopulations that may promote metastatic dissemination. In this Perspective, we discuss promising techniques that could be used for the identification of these metastatic cells. We first describe methods for isolating patient-derived CTCs and then the use of 3D biomimetic matrixes in their amplification and analysis, followed by methods for further CTC analyses at the single-cell and single-molecule levels. Finally, we discuss how the elucidation of mechanical and morphological properties using techniques such as atomic force microscopy and molecular biomarker identification using nanopore-based detection could be combined in the future to provide patients and their healthcare providers with a more accurate diagnosis.


Assuntos
Células Neoplásicas Circulantes , Humanos , Células Neoplásicas Circulantes/patologia , Prognóstico
20.
J Endod ; 49(3): 301-306, 2023 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-36567061

RESUMO

INTRODUCTION: The aim of this study was to compare E1-Irrisonic (Helse Ultrasonics, Ocoee, FL) and Irri Black (Helse Ultrasonics), a novel ultrasonic tip with diamondlike carbon treatment, regarding their design, metallurgy, microhardness, bending resistance, and time to fracture under the oscillatory fatigue test. METHODS: A total of 17 E1-Irrisonic and 17 Irri Black new ultrasonic tips were selected. The tip geometry and surface finishing were assessed using scanning electron microscopy. The elemental composition was defined by energy-dispersive X-ray spectroscopy. Hardness Knoop was calculated using a microhardness tester. The maximum load required to displace the instrument in 45° was recorded in gram/force, oscillatory fatigue was measured in seconds at the moment of instrument fracture, and the size of the separate fragments was determined in millimeters. The Student t test was used for statistical comparison (α = 5%). RESULTS: Scanning electron microscopic analyses revealed that E1-Irrisonic had a flat end tip, whereas a noncutting rounded tip was observed in Irri Black. The surface of E1-Irrisonic was smoother than Irri Black, which was irregular. Energy-dispersive X-ray spectroscopic analyses showed that the elemental compositions of the E1-Irrisonic and Irri Black tips were consistent with stainless steel and titanium-aluminum alloys, respectively. Irri Black showed significantly higher bending load resistance, time to fracture under oscillatory motion, and hardness Knoop than the E1-Irrisonic tip (P < .05), whereas the length of fragments was similar (P > .05). CONCLUSION: Diamondlike carbon treatment improved hardness Knoop and reduced the flexibility of the Irri Black ultrasonic tip, improving its time to fracture under oscillatory motion compared with the nontreated E1-Irrisonic tip.


Assuntos
Carbono , Ultrassom , Humanos , Dureza , Titânio/química , Teste de Materiais , Microscopia Eletrônica de Varredura , Propriedades de Superfície , Desenho de Equipamento , Preparo de Canal Radicular
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA