Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
1.
Artigo em Inglês | MEDLINE | ID: mdl-33221863

RESUMO

OBJECTIVES: Our goal was to compare results between a standard computed tomography (CT)-based strategy, the 'three-step preoperative sequential planning' (3-step PSP), for pulmonary valve replacement in repaired tetralogy of Fallot versus a conventional planning approach. METHODS: We carried out a retrospective study with unmatched and matched groups. The 3-step PSP comprised the planning of mediastinal re-entry, cannulation for cardiopulmonary bypass (CPB) and the main procedure, using standard 3-dimensional videos. Operative times (skin incision to CPB, CPB time, end of CPB to skin closure and cross-clamp time) as well as postoperative length of stay and in-hospital mortality were compared. RESULTS: Eighty-two patients (49% classical tetralogy of Fallot) underwent an operation (85% with pulmonary homograft) with 1.22% in-hospital mortality. The 3-step PSP (n = 14) and the conventional planning (n = 68) groups were compared. There were no statistically significant differences in the preoperative characteristics. Differences were observed in the total operative time (P = 0.009), skin incision to CPB (P = 0.034) and cross-clamp times (74 ± 33 vs 108 ± 47 min; P = 0.006), favouring the 3-step PSP group. Eight matched pairs were compared showing differences in the total operative time (263 ± 44 vs 360 ± 66 min; P = 0.008), CPB time (123 ± 34 vs 190 ± 43 min; P = 0.008) and postoperative length of stay (P = 0.031), favouring the 3-step PSP group. CONCLUSIONS: In patients with repaired tetralogy of Fallot undergoing pulmonary valve replacement, preoperative planning using a standard CT-based strategy, the 3-step PSP, is associated with shorter operative times and shorter postoperative length of stay.

3.
J Am Coll Cardiol ; 62(23): 2227-43, 2013 Dec 10.
Artigo em Inglês | MEDLINE | ID: mdl-24080109

RESUMO

Because the real benefit of pulmonary valve replacement (PVR) in patients with repaired tetralogy of Fallot who develop pulmonary insufficiency remains unclear, it is necessary to analyze the evidence published around the world. We performed a systematic review of studies that reported data about the effect of PVR in patients with repaired tetralogy of Fallot that developed pulmonary insufficiency, until December 2012. The variables chosen to represent the benefit were both right ventricular (RV) and left ventricular measures, QRS duration, and functional class. The principal summary measures were difference in means with 95% confidence interval and p values (considered statistically significant when p < 0.05). The differences in means were combined across studies with the weighted DerSimonian-Laird random effects model. Meta-analysis, sensitivity analysis, and meta-regression were completed with the software Comprehensive Meta-Analysis (version 2, Biostat, Inc., Englewood, New Jersey). Forty-eight studies involving 3,118 patients met the eligibility criteria. The pooled 30-day mortality was 0.87% (47 studies; 27 of 3,100 patients); the pooled 5-year mortality was 2.2% (24 studies; 49 of 2,231 patients); the pooled 5-year re-PVR was 4.9% (15 studies; 88 of 1,798 patients). The results of this meta-analysis demonstrate that after PVR: 1) the RV experiences improvement of its volumes and function; 2) the left ventricle experiences improvement of its function; 3) QRS duration decreases; 4) symptoms improve; 5) pre-operative RV geometry modulates the effect of PVR; and 6) there is important heterogeneity of the effects among the studies, and few publication biases. In conclusion, PVR seems to be a positive approach in the analyzed scenario.


Assuntos
Procedimentos Cirúrgicos Cardíacos/efeitos adversos , Sistema de Condução Cardíaco/fisiopatologia , Implante de Prótese de Valva Cardíaca , Insuficiência da Valva Pulmonar/etiologia , Insuficiência da Valva Pulmonar/cirurgia , Tetralogia de Fallot/cirurgia , Função Ventricular Esquerda , Função Ventricular Direita , Implante de Prótese de Valva Cardíaca/mortalidade , Humanos , Insuficiência da Valva Pulmonar/mortalidade , Insuficiência da Valva Pulmonar/fisiopatologia , Volume Sistólico , Tetralogia de Fallot/complicações , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA