Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 51
Filtrar
1.
Viruses ; 16(8)2024 Aug 03.
Artigo em Inglês | MEDLINE | ID: mdl-39205221

RESUMO

Neurological involvement has been widely reported in SARS-CoV-2 infection. However, viral identification in the cerebrospinal fluid (CSF) is rarely found. The aim of this study is to evaluate the accuracy of virological and immunological biomarkers in CSF for the diagnosis of neuroCOVID-19. We analyzed 69 CSF samples from patients with neurological manifestations: 14 with suspected/confirmed COVID-19, with 5 additional serial CSF samples (group A), and as a control, 50 non-COVID-19 cases (group B-26 with other neuroinflammatory diseases; group C-24 with non-inflammatory diseases). Real-time reverse-transcription polymerase chain reaction (real-time RT-PCR) was used to determine SARS-CoV-2, and specific IgG, IgM, neopterin, and protein 10 induced by gamma interferon (CXCL-10) were evaluated in the CSF samples. No samples were amplified for SARS-CoV-2 by real-time RT-PCR. The sensitivity levels of anti-SARS-CoV-2 IgG and IgM were 50% and 14.28%, respectively, with 100% specificity for both tests. CXCL-10 showed high sensitivity (95.83%) and specificity (95.83%) for detection of neuroinflammation. Serial CSF analysis showed an association between the neuroinflammatory biomarkers and outcome (death and hospital discharge) in two cases (meningoencephalitis and rhombencephalitis). The detection of SARS-CoV-2 RNA and specific immunoglobulins in the CSF can be used for neuroCOVID-19 confirmation. Additionally, CXCL-10 in the CSF may contribute to the diagnosis and monitoring of neuroCOVID-19.


Assuntos
Anticorpos Antivirais , Biomarcadores , COVID-19 , Quimiocina CXCL10 , Imunoglobulina G , Imunoglobulina M , SARS-CoV-2 , Humanos , COVID-19/diagnóstico , COVID-19/líquido cefalorraquidiano , COVID-19/virologia , SARS-CoV-2/isolamento & purificação , SARS-CoV-2/genética , Masculino , Pessoa de Meia-Idade , Feminino , Imunoglobulina G/líquido cefalorraquidiano , Imunoglobulina G/sangue , Adulto , Imunoglobulina M/líquido cefalorraquidiano , Imunoglobulina M/sangue , Idoso , Biomarcadores/líquido cefalorraquidiano , Quimiocina CXCL10/líquido cefalorraquidiano , Anticorpos Antivirais/líquido cefalorraquidiano , Anticorpos Antivirais/sangue , Sensibilidade e Especificidade , Neopterina/líquido cefalorraquidiano , Idoso de 80 Anos ou mais , Doenças do Sistema Nervoso/diagnóstico , Doenças do Sistema Nervoso/virologia , Doenças do Sistema Nervoso/líquido cefalorraquidiano , Adulto Jovem
2.
PLoS One ; 19(6): e0298579, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38905178

RESUMO

BACKGROUND: As new and improved antigen-detecting rapid diagnostic tests for SARS-CoV-2 infection (Ag-RDT) continue to be developed, assessing their diagnostic performance is necessary to increase test options with accurate and rapid diagnostic capacity especially in resource-constrained settings. This study aimed to assess the performance of two Ag-RDTs in a population-based study. METHODS: We conducted a diagnostic accuracy study in neighborhoods with high socioeconomic vulnerability in Salvador-Brazil, including individuals aged ≥12 years old who attended primary health services, between July and December 2022, with COVID-19 symptoms or who had been in contact with a confirmed case. Two Ag-RDTs were compared in parallel using reverse transcription polymerase chain reaction (RT-PCR) as reference standard, the PanbioTM COVID-19 Ag test (Abbott®) and Immuno-Rapid COVID-19 Ag (WAMA Diagnostic®). Sensitivity, specificity, positive (PPV) and negative predictive values (NPV) were calculated. RESULTS: For the Abbott test the sensitivity was 52.7% (95% CI: 44.3% - 61.0%), specificity 100% (95% CI: 98.7% - 100%), PPV 100% (95% CI: 95.4% - 100%) and NPV 80.4% (95% CI: 75.9% - 84.4%). For the WAMA test, the sensitivity was 53.4% (95% CI: 45.0% - 61.6%), specificity 100% (95% CI: 98.7% - 100%), PPV 100% (95% CI: 95.4% - 100%) and NPV 80.7% (95% CI: 76.2% - 84.6%). Sensitivity for the group with Cycle Threshold (CT) <24 was 82.3% (95%CI: 72.1-90.0, n = 83) for PanbioTM COVID-19 Ag test and 87.3% (95%CI: 77.9-93.8, n = 83) for Immuno-Rapid COVID-19 Ag test. CONCLUSION: Sensitivity for both Ag-RDT was lower than reported by manufacturers. In the stratified analysis, sensitivity was higher among those with lower CT values <24. Specificity was high for both rapid antigen tests. Both Ag-RDT showed to be useful for rapid diagnostic of potential cases of COVID-19. Negative results must be assessed carefully according to clinical and epidemiological information.


Assuntos
Teste Sorológico para COVID-19 , COVID-19 , SARS-CoV-2 , Sensibilidade e Especificidade , Humanos , COVID-19/diagnóstico , COVID-19/imunologia , COVID-19/epidemiologia , Masculino , SARS-CoV-2/imunologia , SARS-CoV-2/isolamento & purificação , Adulto , Feminino , Pessoa de Meia-Idade , Brasil/epidemiologia , Criança , Teste Sorológico para COVID-19/métodos , Adolescente , Antígenos Virais/imunologia , Adulto Jovem , Idoso , Fatores Socioeconômicos
3.
J Med Virol ; 96(5): e29621, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38654686

RESUMO

Mpox is a zoonotic disease historically reported in Africa. Since 2003, limited outbreaks have occurred outside Africa. In 2022, the global spread of cases with sustained interhuman transmission and unusual disease features raised public health concerns. We explore the mpox outbreak in Rio de Janeiro (RJ) state, Brazil, in an observational study of mpox-suspected cases from June to December 2022. Data collection relied on a public healthcare notification form. Diagnosis was determined by MPXV-PCR. In 46 confirmed cases, anti-OPXV IgG was determined by ELISA, and seven MPXV genomes were sequenced. A total of 3095 cases were included, 816 (26.3%) with positive MPXV-PCR results. Most positive cases were men in their 30 s and MSM. A total of 285 (34.9%) MPXV-PCR+ patients live with HIV. Eight were coinfected with varicella-zoster virus. Anogenital lesions and adenomegaly were associated with the diagnosis of mpox. Females and individuals under 18 represented 9.4% and 5.4% of all confirmed cases, respectively, showing higher PCR cycle threshold (Ct) values and fewer anogenital lesions compared to adult men. Anti-OPXV IgG was detected in 29/46 (63.0%) patients. All analyzed sequences belonged to clade IIb. In RJ state, mpox presented a diverse clinical picture, represented mainly by mild cases with low complication rates and prominent genital involvement. The incidence in females and children was higher than usually reported. The observation of a bimodal distribution of Ct values, with few positive results, may suggest the need to review the diagnostic criteria in these groups.


Assuntos
Surtos de Doenças , Humanos , Brasil/epidemiologia , Masculino , Feminino , Adulto , Adulto Jovem , Adolescente , Pessoa de Meia-Idade , Animais , Zoonoses/epidemiologia , Zoonoses/virologia , Herpesvirus Humano 3/genética , Herpesvirus Humano 3/isolamento & purificação , Criança , Infecções por HIV/epidemiologia , Infecções por HIV/virologia , Anticorpos Antivirais/sangue , Idoso , Imunoglobulina G/sangue
4.
Artigo em Inglês | MEDLINE | ID: mdl-38198377

RESUMO

The global reemergence of measles in 2018-2019 reinforces the relevance of high-coverage immunization to maintain the disease elimination. During an outbreak in the Sao Paulo State in 2019, several measles cases were reported in individuals who were adequately vaccinated according to the current immunization schedule recommends. This study aimed to assess measles IgG antibody seropositivity and titers in previously vaccinated adults. A cross-sectional study was conducted at CRIE-HC-FMUSP (Sao Paulo, Brazil) in 2019. It included healthy adults who had received two or more Measles-Mumps-Rubella vaccines (MMR) and excluded individuals with immunocompromising conditions. Measles IgG antibodies were measured and compared by ELISA (Euroimmun®) and chemiluminescence (LIASON®). The association of seropositivity and titers with variables of interest (age, sex, profession, previous measles, number of measles-containing vaccine doses, interval between MMR doses, and time elapsed since the last MMR dose) was analyzed. A total of 162 participants were evaluated, predominantly young (median age 30 years), women (69.8%) and healthcare professionals (61.7%). The median interval between MMR doses was 13.2 years, and the median time since the last dose was 10.4 years. The seropositivity rate was 32.7% by ELISA and 75.3% by CLIA, and a strong positive correlation was found between the tests. Multivariate analyses revealed that age and time since the last dose were independently associated with positivity. Despite being a single-center evaluation, our results suggest that measles seropositivity may be lower than expected in adequately immunized adults. Seropositivity was higher among older individuals and those with a shorter time since the last MMR vaccine dose.


Assuntos
Anticorpos Antivirais , Sarampo , Humanos , Feminino , Adulto , Estudos Transversais , Brasil/epidemiologia , Surtos de Doenças , Sarampo/prevenção & controle
5.
iScience ; 26(7): 107219, 2023 Jul 21.
Artigo em Inglês | MEDLINE | ID: mdl-37529320

RESUMO

The vast spectrum of clinical features of COVID-19 keeps challenging scientists and clinicians. Low resistance to infection might result in long-term viral persistence, but the underlying mechanisms remain unclear. Here, we studied the immune response of immunocompetent COVID-19 patients with prolonged SARS-CoV-2 infection by immunophenotyping, cytokine and serological analysis. Despite viral loads and symptoms comparable to regular mildly symptomatic patients, long-term carriers displayed weaker systemic IFN-I responses and fewer circulating pDCs and NK cells at disease onset. Type 1 cytokines remained low, while type-3 cytokines were in turn enhanced. Of interest, we observed no defects in antigen-specific cytotoxic T cell responses, and circulating antibodies displayed higher affinity against different variants of SARS-CoV-2 Spike protein in these patients. The identification of distinct immune responses in long-term carriers adds up to our understanding of essential host protective mechanisms to ensure tissue damage control despite prolonged viral infection.

6.
J Proteome Res ; 22(6): 1908-1922, 2023 06 02.
Artigo em Inglês | MEDLINE | ID: mdl-37167433

RESUMO

The adsorbed vaccine SARS-CoV-2 (inactivated) produced by Sinovac (SV) was the first vaccine against COVID-19 to be used in Brazil. To understand the metabolic effects of SV in Brazilian subjects, NMR-based metabolomics was used, and the immune response was studied in Brazilian subjects. Forty adults without (group-, n = 23) and with previous COVID-19 infection (group+, n = 17) were followed-up for 90 days postcompletion of the vaccine regimen. After 90 days, our results showed that subjects had increased levels of lipoproteins, lipids, and N-acetylation of glycoproteins (NAG) as well as decreased levels of amino acids, lactate, citrate, and 3-hydroxypropionate. NAG and threonine were the highest correlated metabolites with N and S proteins, and neutralizing Ab levels. This study sheds light on the immunometabolism associated with the use of SV in Brazilian subjects from Rio de Janeiro and identifies potential metabolic markers associated with the immune status.


Assuntos
COVID-19 , SARS-CoV-2 , Adulto , Humanos , Brasil , Formação de Anticorpos , Vacinas contra COVID-19 , Imunização , Anticorpos Antivirais
7.
PeerJ ; 10: e14547, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36540807

RESUMO

Objective: To analyze the long-term dynamics of antibodies against SARS-CoV-2 and understand the impact of age, gender, and viral load on patients' immunological response. Methods: Serum samples were obtained from 231 COVID-19 positive patients from Macaé, in Rio de Janeiro state, in Brazil, from June 2020 until January 2021. The production of IgA, IgM, IgG, and IgE against S glycoprotein was analyzed using the S-UFRJ assay, taking into account the age, gender, and viral load. Results: Analysis of antibody production over 7 months revealed that IgA positivity gradually decreased after the first month. Additionally, the highest percentage of IgM positivity occurred in the first month (97% of patients), and declined after this period, while IgG positivity remained homogeneous for all 7 months. The same analysis for IgE revealed that almost all samples were negative. The comparison of antibody production between genders showed no significant difference. Regarding the age factor and antibody production, patients aged ≥60 years produced almost twice more IgA than younger ones (17-39 years old). Finally, a relationship between viral load and antibody production was observed only for older patients. Conclusions: Our work provides an overview of long-term production of antibodies against SARS-CoV-2, suggesting prolonged production of IgA and IgM antibodies for 3 months and continued IgG production for over 7 months. In addition, it identified a correlation between viral load and IgM titers in the older group and, finally, different IgA production between the age groups.


Assuntos
COVID-19 , SARS-CoV-2 , Humanos , Feminino , Masculino , Adolescente , Adulto Jovem , Adulto , Anticorpos Antivirais , Imunoglobulina G , Brasil/epidemiologia , Imunoglobulina M , Imunoglobulina A , Imunoglobulina E
8.
Microbiol Spectr ; 10(6): e0201222, 2022 12 21.
Artigo em Inglês | MEDLINE | ID: mdl-36448777

RESUMO

The COVID-19 pandemic has led to the commercialization of many antigen-based rapid diagnostic tests (Ag-RDTs), requiring independent evaluations. This report describes the clinical evaluation of the Novel Coronavirus 2019-nCoV Antigen Test (Colloidal Gold) (Beijing Hotgen Biotech Co., Ltd.), at two sites within Brazil and one in the United Kingdom. The collected samples (446 nasal swabs from Brazil and 246 nasopharyngeal samples from the UK) were analyzed by the Ag-RDT and compared to reverse transcription-quantitative PCR (RT-qPCR). Analytical evaluation of the Ag-RDT was performed using direct culture supernatants of SARS-CoV-2 strains from the wild-type (B.1), Alpha (B.1.1.7), Delta (B.1.617.2), Gamma (P.1), and Omicron (B.1.1.529) lineages. An overall sensitivity and specificity of 88.2% (95% confidence interval [CI], 81.3 to 93.3) and 100.0% (95% CI, 99.1 to 100.0), respectively, were obtained for the Brazilian and UK cohorts. The analytical limit of detection was determined as 1.0 × 103 PFU/mL (Alpha), 2.5 × 102 PFU/mL (Delta), 2.5 × 103 PFU/mL (Gamma), and 1.0 × 103 PFU/mL (Omicron), giving a viral copy equivalent of approximately 2.1 × 104 copies/mL, 9.0 × 105 copies/mL, 1.7 × 106 copies/mL, and 1.8 × 105 copies/mL for the Ag-RDT, respectively. Overall, while a higher sensitivity was claimed by the manufacturers than that found in this study, this evaluation finds that the Ag-RDT meets the WHO minimum performance requirements for sensitivity and specificity of COVID-19 Ag-RDTs. This study illustrates the comparative performance of the Hotgen Ag-RDT across two global settings and considers the different approaches in evaluation methods. IMPORTANCE Since the beginning of the SARS-CoV-2 pandemic, we have witnessed growing numbers of antigen rapid diagnostic tests (Ag-RDTs) being brought to market. In the United Kingdom, this was somewhat controlled indirectly as the government offered free tests from a small number of companies. However, as this has now ceased, individuals are responsible for their own acquisition of test kits. Similarly in Brazil, as of January 2022, pharmacies and other health care retailers are permitted to sell Ag-RDTs directly to the community. Many of these Ag-RDTs have not been externally evaluated, and results are not readily available to the public. Thus, there is now a need for a transparent evaluation of Ag-RDTs with both analytical and clinical evaluation. We present an independent review of the Novel Coronavirus 2019-nCoV Antigen Test (Colloidal Gold) (Beijing Hotgen Biotech Co., Ltd.), at two sites within Brazil and one in the United Kingdom.


Assuntos
COVID-19 , SARS-CoV-2 , Humanos , SARS-CoV-2/genética , Brasil , COVID-19/diagnóstico , Pandemias , Reino Unido , Coloide de Ouro
9.
PLoS One ; 17(9): e0269011, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36121796

RESUMO

Population surveillance in COVID-19 Pandemic is crucial to follow up the pace of disease and its related immunological status. Here we present a cross-sectional study done in Maricá, a seaside town close to the city of Rio de Janeiro, Brazil. Three rounds of study sampling, enrolling a total of 1134 subjects, were performed during May to August 2021. Here we show that the number of individuals carrying detectable IgG antibodies and the neutralizing antibody (NAb) levels were greater in vaccinated groups compared to unvaccinated ones, highlighting the importance of vaccination to attain noticeable levels of populational immunity against SARS-CoV-2. Moreover, we found a decreased incidence of COVID-19 throughout the study, clearly correlated with the level of vaccinated individuals as well as the proportion of individuals with detectable levels of IgG anti-SARS-CoV-2 and NAb. The observed drop occurred even during the introduction of the Delta variant in Maricá, what suggests that the vaccination slowed down the widespread transmission of this variant. Overall, our data clearly support the use of vaccines to drop the incidence associated to SARS-CoV-2.


Assuntos
COVID-19 , Cobertura Vacinal , Anticorpos Neutralizantes , Anticorpos Antivirais , Brasil/epidemiologia , COVID-19/epidemiologia , COVID-19/prevenção & controle , Estudos Transversais , Humanos , Imunoglobulina G , Incidência , Pandemias , SARS-CoV-2
10.
Front Microbiol ; 13: 912138, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35966714

RESUMO

Severe acute respiratory syndrome-related coronavirus (SARS-CoV-2) transmission occurs even among fully vaccinated individuals; thus, prompt identification of infected patients is central to control viral circulation. Antigen rapid diagnostic tests (Ag-RDTs) are highly specific, but sensitivity is variable. Discordant RT-qPCR vs. Ag-RDT results are reported, raising the question of whether negative Ag-RDT in positive RT-qPCR samples could imply the absence of infectious viruses. To study the relationship between negative Ag-RDT results with virological, molecular, and serological parameters, we selected a cross-sectional and a follow-up dataset and analyzed virus culture, subgenomic RNA quantification, and sequencing to determine infectious viruses and mutations. We demonstrated that RT-qPCR positive while SARS-CoV-2 Ag-RDT negative discordant results correlate with the absence of infectious virus in nasopharyngeal samples. A decrease in sgRNA detection together with an expected increase in detectable anti-S and anti-N IgGs was also verified in these samples. The data clearly demonstrate that a negative Ag-RDT sample is less likely to harbor infectious SARS-CoV-2 and, consequently, has a lower transmissible potential.

11.
Biochem Eng J ; 186: 108537, 2022 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-35874089

RESUMO

Serological tests detect antibodies generated by infection or vaccination, and are indispensable tools along different phases of a pandemic, from early monitoring of pathogen spread up to seroepidemiological studies supporting immunization policies. This work discusses the development of an accurate and affordable COVID-19 antibody test, from production of a recombinant protein antigen up to test validation and economic analysis. We first developed a cost-effective, scalable technology to produce SARS-COV-2 spike protein and then used this antigen to develop an enzyme-linked immunosorbent assay (ELISA). A receiver operator characteristic (ROC) analysis allowed optimizing the cut-off and confirmed the high accuracy of the test: 98.6% specificity and 95% sensitivity for 11+ days after symptoms onset. We further showed that dried blood spots collected by finger pricking on simple test strips could replace conventional plasma/serum samples. A cost estimate was performed and revealed a final retail price in the range of one US dollar, reflecting the low cost of the ELISA test platform and the elimination of the need for venous blood sampling and refrigerated sample handling in clinical laboratories. The presented workflow can be completed in 4 months from first antigen expression to final test validation. It can be applied to other pathogens and in future pandemics, facilitating reliable and affordable seroepidemiological surveillance also in remote areas and in low-income countries.

12.
J Exp Med ; 219(9)2022 09 05.
Artigo em Inglês | MEDLINE | ID: mdl-35796685

RESUMO

Severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) continues to be a global problem in part because of the emergence of variants of concern that evade neutralization by antibodies elicited by prior infection or vaccination. Here we report on human neutralizing antibody and memory responses to the Gamma variant in a cohort of hospitalized individuals. Plasma from infected individuals potently neutralized viruses pseudotyped with Gamma SARS-CoV-2 spike protein, but neutralizing activity against Wuhan-Hu-1-1, Beta, Delta, or Omicron was significantly lower. Monoclonal antibodies from memory B cells also neutralized Gamma and Beta pseudoviruses more effectively than Wuhan-Hu-1. 69% and 34% of Gamma-neutralizing antibodies failed to neutralize Delta or Wuhan-Hu-1. Although Class 1 and 2 antibodies dominate the response to Wuhan-Hu-1 or Beta, 54% of antibodies elicited by Gamma infection recognized Class 3 epitopes. The results have implications for variant-specific vaccines and infections, suggesting that exposure to variants generally provides more limited protection to other variants.


Assuntos
COVID-19 , SARS-CoV-2 , Anticorpos Neutralizantes , Anticorpos Antivirais , Formação de Anticorpos , Humanos , Glicoproteínas de Membrana/metabolismo , Testes de Neutralização , Glicoproteína da Espícula de Coronavírus , Proteínas do Envelope Viral
13.
Front Immunol ; 13: 884760, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35844561

RESUMO

The SARS-CoV-2 pandemic has had a social and economic impact worldwide, and vaccination is an efficient strategy for diminishing those damages. New adjuvant formulations are required for the high vaccine demands, especially adjuvant formulations that induce a Th1 phenotype. Herein we assess a vaccination strategy using a combination of Alum and polyinosinic:polycytidylic acid [Poly(I:C)] adjuvants plus the SARS-CoV-2 spike protein in a prefusion trimeric conformation by an intradermal (ID) route. We found high levels of IgG anti-spike antibodies in the serum by enzyme linked immunosorbent assay (ELISA) and high neutralizing titers against SARS-CoV-2 in vitro by neutralization assay, after two or three immunizations. By evaluating the production of IgG subtypes, as expected, we found that formulations containing Poly(I:C) induced IgG2a whereas Alum did not. The combination of these two adjuvants induced high levels of both IgG1 and IgG2a. In addition, cellular immune responses of CD4+ and CD8+ T cells producing interferon-gamma were equivalent, demonstrating that the Alum + Poly(I:C) combination supported a Th1 profile. Based on the high neutralizing titers, we evaluated B cells in the germinal centers, which are specific for receptor-binding domain (RBD) and spike, and observed that more positive B cells were induced upon the Alum + Poly(I:C) combination. Moreover, these B cells produced antibodies against both RBD and non-RBD sites. We also studied the impact of this vaccination preparation [spike protein with Alum + Poly(I:C)] in the lungs of mice challenged with inactivated SARS-CoV-2 virus. We found a production of IgG, but not IgA, and a reduction in neutrophil recruitment in the bronchoalveolar lavage fluid (BALF) of mice, suggesting that our immunization scheme reduced lung inflammation. Altogether, our data suggest that Alum and Poly(I:C) together is a possible adjuvant combination for vaccines against SARS-CoV-2 by the intradermal route.


Assuntos
COVID-19 , Vacinas Virais , Adjuvantes Imunológicos , Compostos de Alúmen , Animais , Linfócitos T CD8-Positivos , Vacinas contra COVID-19 , Humanos , Imunoglobulina G , Camundongos , Poli I-C , SARS-CoV-2 , Glicoproteína da Espícula de Coronavírus
14.
Microbiol Spectr ; 10(3): e0125022, 2022 06 29.
Artigo em Inglês | MEDLINE | ID: mdl-35652635

RESUMO

Community testing is a crucial tool for the early identification of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) infection and transmission control. The emergence of the highly mutated Omicron variant (B.1.1.529) raised concerns about its primary site of replication, impacting sample collection and its detectability by rapid antigen tests. We tested the performance of the Panbio antigen rapid diagnostic test (Ag-RDT) using nasal and oral specimens for COVID-19 diagnosis in 192 symptomatic individuals, with quantitative reverse transcription-PCR (RT-qPCR) of nasopharyngeal samples as a control. Variant of concern (VOC) investigation was performed with the 4Plex SARS-CoV-2 screening kit. The SARS-CoV-2 positivity rate was 66.2%, with 99% of the positive samples showing an amplification profile consistent with that of the Omicron variant. Nasal Ag-RDT showed higher sensitivity (89%) than oral (12.6%) Ag-RDT. Our data showed good performance of the Ag-RDT in a pandemic scenario dominated by the Omicron VOC. Furthermore, our data also demonstrated that the Panbio COVID-19 antigen rapid diagnostic test does not provide good sensitivity with oral swabs for Omicron Ag-RDT detection. IMPORTANCE This study showed that the antigen rapid test for COVID19 worked fine using nasal swabs when it was utilized in patients infected with the Omicron variant, showing a concordance with PCR in 93% of patients tested. The nasal swab yielded more reliable results than the oral swab when an antigen rapid diagnosis test (the Panbio COVID-19 antigen rapid diagnostic test) was used in patients infected with the Omicron variant.


Assuntos
COVID-19 , COVID-19/diagnóstico , Teste para COVID-19 , Testes Diagnósticos de Rotina , Humanos , SARS-CoV-2/genética , Sensibilidade e Especificidade
15.
Viruses ; 15(1)2022 12 28.
Artigo em Inglês | MEDLINE | ID: mdl-36680123

RESUMO

The Wyeth strain of vaccinia virus (VACV) produced by Wyeth Pharmaceuticals was supposedly used to manufacture the old freeze-dried American smallpox vaccine, Dryvax, until its discontinuation in 2008. Although the genomic sequences of numerous Dryvax clones have been reported, data on VACV-Wyeth genomes are still lacking. Genomic analysis of old VACV strains is relevant to understand the evolutionary relationships of smallpox vaccines, particularly with the recent resumption of smallpox vaccination in certain population groups as an attempt to control the worldwide monkeypox outbreak. Here we analyzed the complete genome sequences of three VACV-Wyeth clonal isolates obtained from a single seed vial donated to the Brazilian eradication program in the 1970s. Wyeth clones show >99.3% similarity to each other and >95.3% similarity with Dryvax clones, mapping together in clade I of the vaccinia group. Although the patterns of SNPs and INDELs comparing Dryvax and Wyeth clones are overall uniform, important differences were detected particularly at the ends of the genome. In addition, we detected recombinant events of clone Wyeth A111 and the Dryvax clone Acam2000, suggesting that other regions of the genomes may have similar patchy patterns of recombination. A small-scale serological survey using VACV-Wyeth as antigen in ELISA assays revealed that 63 of the 65 individuals born before the end of smallpox vaccination in Brazil still have anti-VACV IgG antibodies, demonstrating the usefulness of the VACV-Wyeth strain in future extended serological studies of the Brazilian population.


Assuntos
Varíola , Vaccinia virus , Humanos , Genômica , Varíola/prevenção & controle , Vacina Antivariólica , Vaccinia virus/genética
16.
EBioMedicine ; 75: 103774, 2022 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-34959134

RESUMO

BACKGROUND: Antigen-detecting rapid diagnostic tests (Ag-RDTs) for SARS-CoV-2 are important diagnostic tools. We assessed clinical performance and ease-of-use of seven Ag-RDTs in a prospective, manufacturer-independent, multi-centre cross-sectional diagnostic accuracy study to inform global decision makers. METHODS: Unvaccinated participants suspected of a first SARS-CoV-2 infection were recruited at six sites (Germany, Brazil). Ag-RDTs were evaluated sequentially, with collection of paired swabs for routine reverse transcription polymerase chain reaction (RT-PCR) testing and Ag-RDT testing. Performance was compared to RT-PCR overall and in sub-group analyses (viral load, symptoms, symptoms duration). To understandusability a System Usability Scale (SUS) questionnaire and ease-of-use (EoU) assessment were performed. FINDINGS: 7471 participants were included in the analysis. Sensitivities across Ag-RDTs ranged from 70·4%-90·1%, specificities were above 97·2% for all Ag-RDTs but one (93·1%).Ag-RDTs, Mologic, Bionote, Standard Q, showed diagnostic accuracy in line with WHO targets (> 80% sensitivity, > 97% specificity). All tests showed high sensitivity in the first three days after symptom onset (≥87·1%) and in individuals with viral loads≥ 6 log10SARS-CoV2 RNA copies/mL (≥ 88·7%). Usability varied, with Rapigen, Bionote and Standard Q reaching very good scores; 90, 88 and 84/100, respectively. INTERPRETATION: Variability in test performance is partially explained by variable viral loads in population evaluated over the course of the pandemic. All Ag-RDTs reach high sensitivity early in the disease and in individuals with high viral loads, supporting their role in identifying transmission relevant infections. For easy-to-use tests, performance shown will likely be maintained in routine implementation. FUNDING: Ministry of Science, Research and Arts, State of Baden-Wuerttemberg, Germany, internal funds from Heidelberg University Hospital, University Hospital Charité - Universitätsmedizin Berlin, UK Department of International Development, WHO, Unitaid.


Assuntos
Antígenos Virais/imunologia , Teste Sorológico para COVID-19 , COVID-19 , Sistemas Automatizados de Assistência Junto ao Leito , SARS-CoV-2/imunologia , Adulto , COVID-19/diagnóstico , COVID-19/imunologia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Sensibilidade e Especificidade
17.
Microbiol Spectr ; 9(3): e0085521, 2021 12 22.
Artigo em Inglês | MEDLINE | ID: mdl-34787498

RESUMO

Current guidelines for patient isolation in COVID-19 cases recommend a symptom-based approach, averting the use of control real-time reverse transcription PCR (rRT-PCR) testing. However, we hypothesized that patients with persistently positive results by RT-PCR for severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) could be potentially infectious for a prolonged time, even if immunocompetent and asymptomatic, which would demand a longer social isolation period than presently recommended. To test this hypothesis, 72 samples from 51 mildly symptomatic immunocompetent patients with long-lasting positive rRT-PCR results for SARS-CoV-2 were tested for their infectiousness in cell culture. The serological response of samples from those patients and virus genomic integrity were also analyzed. Infectious viruses were successfully isolated from 34.38% (22/64) of nasopharynx samples obtained 14 days or longer after symptom onset. Indeed, we observed successful virus isolation up to 128 days. Complete SARS-COV-2 genome integrity was demonstrated, suggesting the presence of replication-competent viruses. No correlation was found between the isolation of infectious viruses and rRT-PCR cycle threshold values or the humoral immune response. These findings call attention to the need to review current isolation guidelines, particularly in scenarios involving high-risk individuals. IMPORTANCE In this study, we evaluated mildly symptomatic immunocompetent patients with long-lasting positive rRT-PCR results for SARS-CoV-2. Infectious viruses were successfully isolated in cell cultures from nasopharynx samples obtained 14 days or longer after symptom onset. Indeed, we observed successful virus isolation for up to 128 days. Moreover, SARS-CoV-2 genome integrity was demonstrated by sequencing, suggesting the presence of replication-competent viruses. These data point out the risk of continuous SARS-CoV-2 transmission from patients with prolonged detection of SARS-CoV-2 in the upper respiratory tract, which has important implications for current precaution guidelines, particularly in settings where vulnerable individuals may be exposed (e.g., nursing homes and hospitals).


Assuntos
Teste de Ácido Nucleico para COVID-19/métodos , COVID-19/imunologia , COVID-19/virologia , SARS-CoV-2/genética , SARS-CoV-2/isolamento & purificação , Adulto , COVID-19/diagnóstico , Feminino , Genoma Viral , Genômica , Humanos , Masculino , Pessoa de Meia-Idade , Nasofaringe/virologia , Isolamento de Pacientes , Carga Viral , Proteínas Virais/isolamento & purificação , Eliminação de Partículas Virais
18.
Braz J Infect Dis ; 25(5): 101630, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34648741

RESUMO

INTRODUCTION: In the current standard of care (SoC) RT-PCR method for COVID-19, the patient's swab was extracted in viral transport media (VTM). For the Panbio™ COVID-19 Ag Rapid Test, the patient swab is flushed out in extraction buffer, of which a small fraction is used for testing, leaving more than half the sample unused. This study was designed to show that RT-PCR results from the residual sample of the Panbio™ COVID-19 Ag Rapid Test (called Novel RT-PCR) are not worse than the SoC RT-PCR result. METHODS: The study was performed using (1) dilution series of five patient samples, and (2) 413 patient samples comparing SOC versus Novel RT-PCR results. RESULTS: For the dilution series samples, all tested positive by both methods. The bias between Ct values of Novel RT-PCR and SoC RT-PCR did not exceed 3.00 Ct using primers N1 and N2. A total of 413 COVID symptomatic patients seeking COVID testing were tested, of which 89 patients tested positive and 324 tested negative with SoC RT-PCR. In 324 patients who tested negative with SoC RT-PCR, 323 tested negative with Novel RT-PCR, and one (1) tested positive. Out of 89 who tested positive with SoC RT-PCR, 80 tested positive with the Novel RT-PCR, and nine patients showed a negative test result. The Overall Percent Agreement for the 413 valid patient sample pairs was 97.5 [95% CI 97 to 98]. CONCLUSION: The study demonstrated that the performance of the Novel RT-PCR method is acceptable compared to the SoC RT-PCR method and can be a useful tool to perform RT-PCR without the need for new swab collections.


Assuntos
COVID-19 , Antígenos Virais , Teste para COVID-19 , Humanos , Reação em Cadeia da Polimerase Via Transcriptase Reversa , SARS-CoV-2 , Sensibilidade e Especificidade
19.
Virus Evol ; 7(2): veab078, 2021 Sep 29.
Artigo em Inglês | MEDLINE | ID: mdl-34642605

RESUMO

Long-term infection of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) represents a challenge to virus dispersion and the control of coronavirus disease 2019 (COVID-19) pandemic. The reason why some people have prolonged infection and how the virus persists for so long are still not fully understood. Recent studies suggested that the accumulation of intra-host single nucleotide variants (iSNVs) over the course of the infection might play an important role in persistence as well as emergence of mutations of concern. For this reason, we aimed to investigate the intra-host evolution of SARS-CoV-2 during prolonged infection. Thirty-three patients who remained reverse transcription polymerase chain reaction (RT-PCR) positive in the nasopharynx for on average 18 days from the symptoms onset were included in this study. Whole-genome sequences were obtained for each patient at two different time points. Phylogenetic, populational, and computational analyses of viral sequences were consistent with prolonged infection without evidence of coinfection in our cohort. We observed an elevated within-host genomic diversity at the second time point samples positively correlated with cycle threshold (Ct) values (lower viral load). Direct transmission was also confirmed in a small cluster of healthcare professionals that shared the same workplace by the presence of common iSNVs. A differential accumulation of missense variants between the time points was detected targeting crucial structural and non-structural proteins such as Spike and helicase. Interestingly, longitudinal acquisition of iSNVs in Spike protein coincided in many cases with SARS-CoV-2 reactive and predicted T cell epitopes. We observed a distinguishing pattern of mutations over the course of the infection mainly driven by increasing A→U and decreasing G→A signatures. G→A mutations may be associated with RNA-editing enzyme activities; therefore, the mutational profiles observed in our analysis were suggestive of innate immune mechanisms of the host cell defense. Therefore, we unveiled a dynamic and complex landscape of host and pathogen interaction during prolonged infection of SARS-CoV-2, suggesting that the host's innate immunity shapes the increase of intra-host diversity. Our findings may also shed light on possible mechanisms underlying the emergence and spread of new variants resistant to the host immune response as recently observed in COVID-19 pandemic.

20.
Mem Inst Oswaldo Cruz ; 116: e210085, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34406222

RESUMO

BACKGROUND: The high demand for adequate material for the gold standard reverse transcription real-time polymerase chain reaction (RT-qPCR)-based diagnosis imposed by the Coronavirus disease 2019 (COVID-19) pandemic, combined with the inherent contamination risks for healthcare workers during nasopharyngeal swab (NP) sample collection and the discomfort it causes patients, brought the need to identify alternative specimens suitable for the diagnosis of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2). OBJECTIVES: The aim of this work was to compare saliva and gingival fluid swabs to NP swabs as specimens for RT-qPCR-based SARS-CoV-2 diagnosis. METHODS: We compared gingival fluid swabs (n = 158) and saliva (n = 207) to the rayon-tipped NP swabs obtained from mild-symptomatic and asymptomatic subjects as specimens for RT-qPCR for SARS-CoV-2 detection. FINDINGS: When compared to NP swabs, gingival fluid swabs had a concordance rate of 15.4% among positive samples, zero among inconclusive, and 100% among negative ones. For saliva samples, the concordance rate was 67.6% among positive samples, 42.9% among inconclusive, and 96.8% among negative ones. However, the concordance rate between saliva and NP swabs was higher (96.9%) within samples with lower cycle threshold (Ct) values (Ct > 10 ≤ 25). MAIN CONCLUSIONS: Our data suggests that whereas gingival fluid swabs are not substitutes for NP swabs, saliva might be considered whenever NP swabs are not available or recommended.


Assuntos
Teste para COVID-19 , COVID-19 , Humanos , Nasofaringe , Reação em Cadeia da Polimerase em Tempo Real , SARS-CoV-2 , Saliva , Manejo de Espécimes
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA