1.
AJR Am J Roentgenol ; 201(5): 1075-82, 2013 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-24147478

RESUMO

OBJECTIVE: The purpose of this study was intrapatient comparison of image quality and radiation dose between MDCT scans of the chest, abdomen, and pelvis obtained with attenuation-based automated kilovoltage selection and sinogram-affirmed iterative reconstruction and scans obtained with standard kilovoltage selection and a filtered backprojection image reconstruction algorithm. MATERIALS AND METHODS: One hundred one oncology patients who had undergone two chest, abdominal, and pelvis CT scans within 1 year were imaged with standard tube voltage selection of 120 kVp using a filtered backprojection reconstruction algorithm (protocol 1) and with attenuation-based automated tube voltage selection using an iterative reconstruction algorithm (protocol 2). Radiation dose parameters (volumetric CT dose index [CTDIvol], dose-length product, and effective dose) as well as image noise, signal-to-noise ratio, and contrast-to-noise ratio were compared. Two independent radiologists evaluated image quality and sharpness. Student t test, Fisher exact test, and Wilcoxon signed-rank test were used for analysis. A p value less than 0.05 was considered significant. RESULTS: Mean ± SD CTDIvol values were 19.9 ± 4.43 mGy and 12.53 ± 4.79 mGy for protocols 1 and 2, respectively (p < 0.0001). Effective dose was 38.2% lower on average using protocol 2 compared with protocol 1 (12.08 vs 19.55 mSv; p < 0.0001). Objective image quality parameters were significantly better in protocol 2 (p < 0.0001). Both radiologists found the overall image quality and sharpness to be similar for both protocols (p > 0.05). CONCLUSION: In patients undergoing CT examination of the chest, abdomen, and pelvis, the combination of attenuation-based automated tube voltage selection with iterative reconstruction significantly reduced radiation dose parameters and maintained objective image quality when compared with standard tube voltage selection associated with filtered backprojection reconstruction.


Assuntos
Tomografia Computadorizada Multidetectores/métodos , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Radiografia Abdominal , Radiografia Torácica , Algoritmos , Meios de Contraste , Feminino , Humanos , Iohexol , Masculino , Pessoa de Meia-Idade , Pelve/diagnóstico por imagem , Doses de Radiação , Estudos Retrospectivos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA