Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 22
Filtrar
1.
Int J Dent Hyg ; 2023 Oct 13.
Artigo em Inglês | MEDLINE | ID: mdl-37831522

RESUMO

OBJECTIVE: To assess peri-implant soft tissues condition, comparing clinical parameters of implants placed in patients with atrophic upper jaws and patients who underwent maxillary resection for oncological reasons. BACKGROUND: Zygomatic implants (ZIs) in oncologic patients could be affected by more complications compared to implants placed in atrophic maxillae. The soft tissue condition is an essential requirement for implant success, but few studies have investigated this topic. METHODS: A nested monocentric prospective parallel cohort (atrophic vs. oncological patients) study was performed. Clinical visits and professional hygiene sessions were performed every three months, and bleeding on probing (BOP), probing pocket depth (PPD), gingival index (GI), plaque index (PI) and implant mobility were recorded by a blind outcome assessor. RESULTS: In total, 77 ZIs placed in 21 patients were evaluated: 54 (70.1%) ZIs were inserted in patients belonging to the atrophic cohort (PAM) and 23 (29.9%) ZIs in the oncologic cohort (OP). The probability of having BOP at the considered mean follow-up (27 months) was 24.8% (95% CI 19.0-31.9) for PAM and 22.9% (95% CI 15.1-33.9) OP. The mean PPD values were 2.78 ± 1.28 (range 1-8) in PAM and 2.91 ± 1.98 (range 0-10) in OP. None of the implants showed mobility. No associations between group belongingness and the entity of PPD, PI, GI and the risk of BOP were found, adjusting for the considered confounding factors (age, smoking and implant position). CONCLUSIONS: Under a strict supportive hygiene therapy protocol ZIs in oncologic patients showed similar peri-implant tissue conditions to that of patients with maxillary atrophy.

2.
J Oral Maxillofac Surg ; 81(10): 1279-1285, 2023 10.
Artigo em Inglês | MEDLINE | ID: mdl-37463659

RESUMO

PURPOSE: Coronectomy is an operation to manage impacted third molars (M3s) considered at high risk for mandibular nerve injury but long-term outcomes are still lacking. The purpose of this study was to estimate the risk of late complications occurring within 10 years following lower M3 coronectomy. METHODS: The investigators designed a prospective cohort study and enrolled a sample of 94 patients treated with coronectomy of third mandibular molars at the Unit of Oral and Maxillofacial Surgery of the University of Bologna, from 2009 to 2012. This follow-up study included all of the patients from the original study who completed 10 years of follow-up. The primary outcome variables is postoperative late complication occurring between 5 and 10 years after coronectomy coded as present or absent. Late complications were defined as root exposure, nerve injury, pulpitis, periapical infection, and reoperation. The secondary outcome variable was probing pocket depth. Covariates examined were age, smoking and type of M3 impaction. Descriptive statistical analyses were performed. RESULTS: The inception cohort was composed of 94 subjects who had 116 coronectomies (k) completed. The study cohort was composed of subjects with 10 years of follow-up and included 48 subjects (k = 60) with a mean age of 28.99 ± 8.9 years. Between years 5 and 10 of follow-up, 2 subjects (4%) have complications; all root exposures diagnosed at years 8 or 9 after surgery. In another case root removal was required for orthodontics reason. No case of nerve injury to the inferior alveolar nerve occurred, and no periapical infection was observed around the residual roots. The mean 10-year probing pocket depth was 3.31 ± 0.92 mm (1,66-5,66 mm). There were too few complications to identify risk factors for late complications. CONCLUSIONS: Within all the limitations of this study, the results of this prospective study imply that coronectomy is a useful surgical technique for the treatment of M3s at high neurological risk, to avoid nerve injury to the inferior alveolar nerve. In addition, after coronectomy, retained roots did not develop late infection or periapical infection in the long term. However, in a few cases, removal of retained roots was required at 10 years, due to root migration in the oral cavity. The risk for late complications is uncommon, but persistent.


Assuntos
Dente Impactado , Traumatismos do Nervo Trigêmeo , Humanos , Adulto Jovem , Adulto , Seguimentos , Estudos Prospectivos , Dente Serotino/cirurgia , Traumatismos do Nervo Trigêmeo/epidemiologia , Traumatismos do Nervo Trigêmeo/etiologia , Incidência , Coroa do Dente/cirurgia , Raiz Dentária/cirurgia , Complicações Pós-Operatórias/epidemiologia , Extração Dentária/efeitos adversos , Dente Impactado/cirurgia , Dente Impactado/complicações , Mandíbula/cirurgia , Nervo Mandibular
3.
Artigo em Inglês | MEDLINE | ID: mdl-37338920

RESUMO

The management of horizontally fully edentulous atrophic ridges is a common problem in dental implantology. This case report describes an alternative modified two-stage presplitting technique. The patient was referred for an implant-supported rehabilitation of their edentulous mandible. CBCT scans showed a mean available bone width of about 3 mm. At the first stage, four linear corticotomies were performed using a piezoelectric surgical device. At the second surgical stage 4 weeks later, bone expansion was performed, and four implants were placed in the interforaminal area. The healing process was uneventful. No fractures of the buccal wall and no neurologic lesions were observed. Postoperative CBCT scans showed a mean bone width gain of about 3.7 mm. Implants were uncovered 6 months after the second surgery, and 1 month later, a fixed provisional screw-retained prosthesis was delivered. This approach could be used as a reconstructive technique that avoids using grafts and reduces treatment times, possible complications, postsurgical morbidity, and costs by exploiting the patient's native bone as much as possible. Considering the limitations of a case report, randomized controlled clinical trials are needed to confirm the results and validate this technique.


Assuntos
Implantes Dentários , Arcada Edêntula , Humanos , Implantação Dentária Endóssea/métodos , Resultado do Tratamento , Transplante Ósseo/métodos , Atrofia/patologia , Mandíbula/diagnóstico por imagem , Mandíbula/cirurgia , Mandíbula/patologia , Prótese Dentária Fixada por Implante , Arcada Edêntula/cirurgia , Arcada Edêntula/reabilitação , Seguimentos , Planejamento de Prótese Dentária
4.
Int J Oral Maxillofac Implants ; 38(3): 462-467, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37279215

RESUMO

PURPOSE: To assess whether the presence or absence of keratinized tissue height (KTh) may have an influence on marginal bone levels, complications, and implant survival for short implants. MATERIALS AND METHODS: The study was designed as parallel cohort retrospective research. Short implants with an implant length < 7 mm were considered. One cohort was composed of patients with short implants surrounded by ≥ 2 mm of KTh (adequate KTh); the other cohort included implants with < 2 mm of KTh (not-adequate KTh). Outcome measures were marginal bone level (MBL) changes, failures, and complications. RESULTS: One hundred ten patients treated with 217 short and extrashort implants (4 to 6.6 mm long) were retrospectively included. The mean follow-up was 4.1 years after prosthetic loading (range: 1 to 8 years). The differences between KTh groups in MBL were not statistically significant at every follow-up considered: 0.05 mm at 1 year (P = .48), 0.06 mm at 3 years (P = .34), 0.04 mm at 5 years (P = .64), and 0.03 at 8 years (P = .82). A total of nine complications were reported: three in the not-adequate KTh group and six in the adequate group; the difference was not statistically significant (OR: 3.03, 95% CI: 0.68 to 13.46, P = .14). Five implants failed due to peri-implantitis, two in the not-adequate KTh group and three in the adequate group, without a statistically significant difference (OR: 2.76, 95% CI: 0.42-17.99, P = .29). CONCLUSION: This study showed no statistically significant differences in MBL, complications, and implant failure rates between short implants with adequate or not-adequate KThs. However, given the importance of patient comfort while brushing and plaque accumulation, keratinized tissue grafts could be important in selected patients, especially for those who are severely atrophic, also taking into consideration all the limitations of this study and the mediumterm follow-up. Nevertheless, longer follow-ups, larger numbers of patients, and randomized controlled clinical trials are needed before making more reliable clinical recommendations. Int J Oral Maxillofac Implants 2023;38:462-467. doi: 10.11607/jomi.9918.


Assuntos
Aumento do Rebordo Alveolar , Implantes Dentários , Humanos , Implantes Dentários/efeitos adversos , Implantação Dentária Endóssea/efeitos adversos , Estudos Retrospectivos , Seguimentos , Planejamento de Prótese Dentária , Prótese Dentária Fixada por Implante/efeitos adversos , Falha de Restauração Dentária , Resultado do Tratamento
5.
Int J Oral Maxillofac Implants ; 37(4): 756-762, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35904832

RESUMO

PURPOSE: The aim of this study was accuracy assessment of placed implants in full-arch cases using specific software and hardware to perform static computer-assisted implantology and immediately loaded prostheses. The degree of deviation existing between planned and achieved implants was carried out by a new noninvasive measurement procedure of the implant position performed on stone casts. MATERIALS AND METHODS: Fourteen stone casts retrieved from 14 full-arch fully guided implant treatments were selected to perform the study. Each cast, manufactured for the surgical treatment by using a specific laboratory kit, was obtained from the respective surgical guide. A sleeve for each implant was embedded into the guide, which helped the examiners to manufacture a stone cast per guide containing the implant analogs, which was used to recover the final position of the planned implants. A total sample of 60 implants were assessed. The postoperative casts, poured to produce the immediate prostheses, were then processed by a contact (or tactile) scanner, and the generated standard tessellation language (STL) files were overlapped (best-fit alignment) using engineering software that revealed all the measured discrepancies. In terms of accuracy, differences relating to arch, assessed bone quality, implant length, and drill length (prolongation short or long) were reported. RESULTS: The use of a noninvasive tactile scanner revealed mean entry point horizontal deviations of 0.30 mm (SD: 0.39 mm), mean entry point vertical deviations of 0.20 mm (SD: 0.25 mm), mean apical horizontal deviations of 0.50 mm (SD: 0.73 mm), and mean apical vertical deviations of 0.24 mm (SD: 0.28 mm). The frontal and lateral angular deviations were investigated, and corresponding mean values of 1.99 degrees (SD: 2.30 degrees) and 1.80 degrees (SD: 2.44 degrees) were detected. CONCLUSION: The reported results demonstrate that the contact tactile scan is a viable and biologic way to assess implant deviations.


Assuntos
Implantes Dentários , Cirurgia Assistida por Computador , Moldes Cirúrgicos , Desenho Assistido por Computador , Tomografia Computadorizada de Feixe Cônico , Implantação Dentária Endóssea/métodos , Imageamento Tridimensional/métodos
6.
Artigo em Inglês | MEDLINE | ID: mdl-35472114

RESUMO

This retrospective study evaluates the clinical and radiographic outcomes of simultaneous guided bone regeneration (GBR) and implant placement procedures in the rehabilitation of partially edentulous and horizontally atrophic dental arches using resorbable membranes. A total of 49 patients were included, and 97 implants were placed. Patients were followed up for 3 to 7 years after loading. The data indicate that GBR with simultaneous implant placement and resorbable membranes can be a good clinical choice, and the data suggest that it could be better to horizontally reconstruct no more than 3 mm of bone in order to reduce the number of complications and to obtain stable results. However, this technique remains difficult and requires expert surgeons.


Assuntos
Implantes Dentários , Boca Edêntula , Regeneração Óssea , Arco Dental , Implantação Dentária Endóssea/métodos , Prótese Dentária Fixada por Implante , Falha de Restauração Dentária , Seguimentos , Humanos , Membranas Artificiais , Estudos Retrospectivos , Resultado do Tratamento
7.
Clin Exp Dent Res ; 8(2): 537-543, 2022 04.
Artigo em Inglês | MEDLINE | ID: mdl-35362247

RESUMO

OBJECTIVES: This study aimed to evaluate the production of customized composite veneers starting from a two-dimensional (2D) digital preview using the Digital Smile System (DSS). MATERIAL AND METHODS: A photographic examination of 30 patients was performed by taking two digital pictures of the face and a digital preview through the DSS. Moreover, optical scans of the dental arches were obtained and the data were entered into a three-dimensional (3D) software to prepare a virtual preview. The standard tessellation language files were sent for production using CAD-CAM technology. The Friedman test, Bonferroni, and Dunn post hoc tests were used, comparing the linear measurements of the 2D and 3D plans and the final veneers (α = .05). RESULTS: Significant differences emerged between the pictures and digital scans on the mesial-distal widths of the lateral incisors and canine. Linear measurements in the 2D plan were significantly different from those of the 3D plan, except for the height measures of incisors. No significant changes were found on comparing the parameters of the 2D and 3D plans with those of the final pieces. CONCLUSIONS: The customized veneers were clinically adequate and similar to 2D and 3D plans, although significant differences emerged between the picture and digital scans as well as between the 2D and 3D plans.


Assuntos
Planejamento de Prótese Dentária , Sorriso , Desenho Assistido por Computador , Planejamento de Prótese Dentária/métodos , Humanos , Incisivo/diagnóstico por imagem
8.
Clin Oral Implants Res ; 33(6): 607-621, 2022 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-35305283

RESUMO

OBJECTIVES: To evaluate the outcomes of bone regeneration using a customized titanium mesh scaffold to cover a bone graft for reconstruction of complex defects of the jaws. MATERIALS AND METHODS: 19 large defects were digitally reconstructed using CT scans according to the prosthetic requirements. A titanium mesh scaffold was designed to cover the bone (autologous/bovine bone particulate) graft. At least 6 months after surgery, a new cone-beam CT was taken. The pre- and postoperative CT datasets were then converted into three-dimensional models and digitally aligned. The actual mesh position was compared to the virtual position to assess the reliability of the digital project. The reconstructed bone volumes (RBVs) were calculated according to the planned bone volumes (PBVs), outlining the areas under the mesh. These values were then correlated with the number of exposures, locations of atrophy, and virtually planned bone volume. RESULTS: The mean matching value between the planned position of the mesh and the actual one was 82 ± 13.4%. 52.3% (40% early and 60% late) exposures were observed, with 15.8% exhibiting infection. 26.3% resulted as failures. The amount of reconstructed bone volume (RBV) in respect to PBV was 65 ± 40.5%, including failures, and 88.2 ± 8.32% without considering the failures. The results of the exposure event were statistically significant (p = .006) in conditioning the bone volume regenerated. CONCLUSIONS: This study obtained up to 88% of bone regeneration in 74% of the cases. The failures encountered (26%) should underline the operator's expertise relevance in conditioning the final result.


Assuntos
Aumento do Rebordo Alveolar , Implantes Dentários , Aumento do Rebordo Alveolar/métodos , Animais , Regeneração Óssea , Transplante Ósseo/métodos , Bovinos , Implantação Dentária Endóssea/métodos , Projetos Piloto , Reprodutibilidade dos Testes , Telas Cirúrgicas , Titânio
9.
Artigo em Inglês | MEDLINE | ID: mdl-35162751

RESUMO

BACKGROUND: Artificial intelligence (AI) has taken hold in public health because more and more people are looking to make a diagnosis using technology that allows them to work faster and more accurately, reducing costs and the number of medical errors. METHODS: In the present study, 120 panoramic X-rays (OPGs) were randomly selected from the Department of Oral and Maxillofacial Sciences of Sapienza University of Rome, Italy. The OPGs were acquired and analyzed using Apox, which takes a panoramic X-rayand automatically returns the dental formula, the presence of dental implants, prosthetic crowns, fillings and root remnants. A descriptive analysis was performed presenting the categorical variables as absolute and relative frequencies. RESULTS: In total, the number of true positive (TP) values was 2.195 (19.06%); true negative (TN), 8.908 (77.34%); false positive (FP), 132 (1.15%); and false negative (FN), 283 (2.46%). The overall sensitivity was 0.89, while the overall specificity was 0.98. CONCLUSIONS: The present study shows the latest achievements in dentistry, analyzing the application and credibility of a new diagnostic method to improve the work of dentists and the patients' care.


Assuntos
Inteligência Artificial , Dente , Humanos , Itália , Radiografia Panorâmica , Software
10.
Clin Implant Dent Relat Res ; 24(1): 4-12, 2022 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-35019219

RESUMO

BACKGROUND: Short implants (up to 5-mm long) have shown good results when compared to longer implants placed in augmented bone. PURPOSE: To evaluate if 4-mm ultrashort implants could also be an alternative to bone augmentation in the severely atrophic posterior jaws. The primary aim of the study was to compare implant survival rates between study groups. MATERIALS AND METHODS: Eighty partially edentulous patients with posterior atrophic jaws (5-6 mm of bone above the mandibular canal and 4-5 mm below the maxillary sinus) were included: 40 patients in the maxilla and 40 in mandible. The patients were randomized to receive one to three 4-mm ultrashort implants or one to three implants at least 10-mm long in augmented bone. Results are reported 5 years after loading with the following outcome measures: implant and prosthetic failures, complications and peri-implant marginal bone level changes. RESULTS: Thirty-two complications were reported for the control group in 18 patients versus 13 complications in 10 patients in the test group, the difference being not statistically significant (p = 0.103). In the augmented group, 12 implants failed in 6 patients versus 7 short implants in 6 cases, and 9 prostheses failed in the control group while 4 in the test one, without statistically significant differences (p = 1.000 and 0.363, respectively). At 5 years after loading, short implants lost on average 0.58 ± 0.40 mm of peri-implant marginal bone and long implants 0.99 ± 0.58 mm, the difference was statistically significant (p = 0.006). CONCLUSION: Four-millimeter ultrashort implants showed similar if not better results when compared to longer implants placed in augmented jaws 5 years after loading. For this reason, their use could be in specific cases preferable to bone augmentation since the treatment is less invasive, faster, cheaper and associated with less morbidity. However, longer follow-ups and larger trials are needed.


Assuntos
Aumento do Rebordo Alveolar , Implantes Dentários , Aumento do Rebordo Alveolar/métodos , Implantação Dentária Endóssea/métodos , Planejamento de Prótese Dentária , Prótese Dentária Fixada por Implante , Falha de Restauração Dentária , Seguimentos , Humanos , Maxila/cirurgia , Resultado do Tratamento
11.
Minerva Dent Oral Sci ; 71(4): 199-205, 2022 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-34546226

RESUMO

BACKGROUND: The aim of this study was to compare the accuracy of 3 different devices for facial images acquisition, useful for prosthodontic esthetic preview. METHODS: Bidimensional extraoral photographs (Nikon D300), facial scans (Bellus3D) and 3D digital stereophotogrammetry photos (3dMD Face System) were acquired from 15 patients. The intraoral impressions of all subjects were digitally taken through a scanner (i500; Medit). Files obtained from each acquisition method were transferred on Exocad Software, and the measurements of the frontal teeth were performed and compared with those of the intraoral scans, assumed as reference. The data were statistically analyzed (Friedman and Dunn tests) with P<0.05. RESULTS: As for central and lateral incisors, no significant difference emerged between 2D digital photography and intraoral scans, both in height and width. Measures obtained with Bellus3D significantly differed from the reference data in width of all teeth, except for central incisors. Values referred to canines were those more subjected to significant distortions in width for all devices. CONCLUSIONS: Within the limits of this study, measures of frontal teeth acquired by 2D digital photography were similar to those of intraoral scans both in height and width, while those obtained with 3D facial scanners were more subjected to distortions in mesial-distal dimension.


Assuntos
Técnica de Moldagem Odontológica , Prostodontia , Desenho Assistido por Computador , Estética Dentária , Humanos , Imageamento Tridimensional , Incisivo/diagnóstico por imagem
12.
Artigo em Inglês | MEDLINE | ID: mdl-34639250

RESUMO

OBJECTIVES: The use of digital devices is strongly influencing the dental rehabilitation workflow both for single-crown rehabilitation and for full-arch prosthetic treatments. METHODS: In this study, trueness was analyzed by overlapping the scan dataset made with Medit I-500 (by using two different tips and two different scan strategies) with the scan dataset made with lab scanning, and the values of the (90°-10°)/2 method were reported. Precision was evaluated by using the same values of trueness coming from the intra-group overlapping (scan dataset made with an IOS overlapped and compared to each other). Moreover, two different software programs of overlapping were used to calculate accuracy values. RESULTS: The mean difference of trueness was 26.61 ± 5.07 µm with the suggested strategy of intraoral scanning and using a new design of the tip, 37.99 ± 4.94 µm with the suggested strategy of intraoral scanning and using the old design of the tip, and 51.22 ± 6.57 µm with a new strategy of intraoral scanning and using the old design of the tip. The mean difference of precision was 23.57 ± 5.77 µm with the suggested strategy of intraoral scanning and using a new design of the tip, 38.34 ± 11.39 µm with the suggested strategy of intraoral scanning and using the old design of the tip, and 46.93 ± 7.15 µm with a new strategy of intraoral scanning and using the old design of the tip. No difference was found in the trueness and precision data extracted using the two different programs of superimposition Geomagic Control X and Medit Compare. CONCLUSIONS: The outcomes of this study showed that the latest version of I-Medit 500 with the use of a new tip seems to be promising in terms of accuracy when a full arch needs to be scanned. Moreover, Medit Compare, which is an application of Medit IOS software, can be used to calculate IOS accuracy.


Assuntos
Desenho Assistido por Computador , Imageamento Tridimensional , Arco Dental/diagnóstico por imagem , Software , Fluxo de Trabalho
13.
Int J Oral Maxillofac Implants ; 36(5): e121-e140, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34698720

RESUMO

PURPOSE: Dynamic navigation is a technique that allows for the placement of dental implants using a computer-guided approach according to preoperative planning. Its accuracy has been assessed in several previous studies. The purpose of this study was to summarize data on implant placement accuracy using dynamic navigation, to synthesize the frequency of intraoperative complications and implant failures, and to compare this technique with static computer-guided surgery and a freehand approach. MATERIALS AND METHODS: Electronic and manual literature searches until December 2019 were performed. The outcome variables were implant placement accuracy using dynamic navigation, accuracy differences between dynamic and static techniques and between dynamic and freehand techniques, intraoperative complications, and implant failures. Random-effects meta-analyses were performed. RESULTS: A total of 32 studies were included; 29 reported accuracy values (2,756 implants), and 10 focused on complications and implant failures (1,039 implants). The pooled mean implant placement errors were 0.81 (95% CI: 0.677 to 0.943) mm at the entry point and 0.910 (95% CI: 0.770 to 1.049) mm at the apical point. The pooled mean vertical and angular deviations were 0.899 (95% CI: 0.721 to 1.078) mm and 3.807 (95% CI: 3.083 to 4.530) degrees. The navigation group showed significantly lower implant placement errors with respect to the freehand technique (P < .01) and similar accuracy values (P ≥ .05) compared with the static technique. The pooled prevalence of failures was 1% (95% CI: 0.00% to 2%). CONCLUSION: Dynamic navigation provided small implant placement errors, comparable with those obtained using static computer-guided surgery, and can be considered a more accurate technique than conventional freehand surgery.


Assuntos
Implantes Dentários , Cirurgia Assistida por Computador , Implantação Dentária Endóssea , Falha de Equipamento , Humanos , Complicações Intraoperatórias
14.
Int J Comput Dent ; 24(3): 253-262, 2021 09 23.
Artigo em Inglês | MEDLINE | ID: mdl-34553890

RESUMO

AIM: Most of the intra- and postoperative patient discomfort related to complex mandibular third molar (M3M) extraction is proportional to the invasiveness of the surgery. This can be minimized through the support of dynamic navigation (DN) technology, which can be successfully applied in dental implantology. Materials and methods: Three patients, one female (aged 25 years) and two males (aged 18 and 51 years, respectively) underwent the DN-supported extraction of partially impacted M3Ms with a flapless approach that required minimal bone removal. The patients' discomfort and the speed of recovery were considered to be proof of the quality of the adopted procedure. RESULTS: No postoperative discomfort such as pain or swelling was recorded in the immediate postoperative period, and no complications were reported within a month of the surgery. No medications were prescribed. The procedure lasted no longer than 20 min in all cases. CONCLUSION: Using DN technology, the real-time 3D monitoring of the clinical situation in each surgical phase enabled the surgeon to avoid soft tissue detachment as well as limit bone loss and intraoperative bleeding, thanks to a precise multi--section of the tooth and important nearby anatomical structures, respectively.


Assuntos
Dente Serotino , Dente Impactado , Feminino , Humanos , Masculino , Mandíbula/cirurgia , Dente Serotino/cirurgia , Tecnologia , Extração Dentária , Dente Impactado/cirurgia
15.
Methods Protoc ; 3(4)2020 Oct 21.
Artigo em Inglês | MEDLINE | ID: mdl-33096897

RESUMO

Dynamic navigation (DN) is a computer-guided technique employed in different surgical fields and recently adopted in dental implantology to improve the accuracy of dental implant insertion. Medication-related osteonecrosis of the jaws (MRONJ) often requires the surgical removal of the impaired, hard tissue, trying at the same time to spare the healthy tissue and the noble anatomical structures. A case of extensive bilateral medication-related osteonecrosis, with the symptomatic involvement of the right mandibular canal, was successfully resolved with the use of ultrasonic surgery associated with a dynamic navigation, in order to limit the invasiveness of the surgical approach improving its reliability and accuracy. The usefulness of this technology in the management of MRONJ can be considered in future clinical trials to confirm the advantages and standardize the technique.

16.
J Clin Med ; 9(10)2020 Oct 12.
Artigo em Inglês | MEDLINE | ID: mdl-33053696

RESUMO

The aim of this study was to evaluate the survival and clinical success rate, complications, and patients' quality of life after computer-aided rehabilitation supported by zygomatic implants in cases of severe maxillary atrophy (ten patients) and in bone defects in oncologic patients (ten patients). All patients underwent computer-aided planning and surgery. Seventy-three zygomatic implants were placed. The mean follow-up period was 39.9 months. Implant survival and clinical success rate, the effectiveness of planning the implant length, biological and prosthetic complications, and the quality of life were evaluated. The five-year implant survival rate for patients with maxillary atrophy and oncologic patients was 97.4% and 96.7%, respectively. The prosthetic survival rate was 100%. Two implant failures occurred in the first year. One implant failure was observed in each group. Minor biological and prosthetic complications occurred in both groups without significant differences. All complications were managed without affecting the treatment. The quality of life increased by 71.3% in the atrophic group and by 82.9% in the oncologic group. Zygomatic implant rehabilitation seems to be a reliable technique for patients with maxillary atrophy and for oncologic patients. The three-dimensional computer-aided approach allows the surgeon to plan the surgery and increase its predictability. Early prosthesis loading certainly allows for better functional outcomes.

17.
Methods Protoc ; 3(3)2020 Jul 22.
Artigo em Inglês | MEDLINE | ID: mdl-32707931

RESUMO

Zygomatic implant rehabilitation is a challenging procedure that requires an accurate prosthetic and implant plan. The aim of this study was to evaluate the malar bone available for three-dimensional zygomatic implant placement on the possible trajectories exhibiting optimal occlusal emergence. After a preliminary analysis on 30 computed tomography (CT) scans of dentate patients to identify the ideal implant emergencies, we used 80 CT scans of edentulous patients to create two sagittal planes representing the possible trajectories of the anterior and posterior zygomatic implants. These planes were rotated clockwise on the ideal emergence points and three different hypothetical implant trajectories per zygoma were drawn for each slice. Then, the engageable malar bone and intra- and extra-sinus paths were measured. It was possible to identify the ideal implant emergences via anatomical landmarks with a high predictability. Significant differences were evident between males and females, between implants featuring anterior and those featuring posterior emergences, and between the different trajectories. The use of internal trajectories provided better bone engagement but required a higher intra-sinus path. A significant association was found between higher intra-sinus paths and lower crestal bone heights.

18.
J Oral Maxillofac Surg ; 78(8): 1355.e1-1355.e11, 2020 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-32482564

RESUMO

PURPOSE: Marsupialization, designed to reduce the mandibular cyst volume, has continued to debated regarding its influence on the healing of the related bone cavity. The aim of the present study was to evaluate the 3-dimensional radiographic variation over time in mandibular odontogenic cystic lesions after marsupialization and assess the correlations between these variations and variables that can affect the procedure. MATERIALS AND METHODS: We planned a retrospective cohort study. The predictor variables were the treatment duration, preoperative volume, patient age, histologic type, and number of preoperative residual bony walls. The outcomes variables were the postoperative volume reduction and the daily reduction rate calculated using computed tomography (CT) from before to after marsupialization using software designed for volumetric reconstruction and measurement of cyst-related bone defects. The descriptive and bivariate statistics were computerized, and the significance level was set at P = .05. RESULTS: The sample included 15 patients (12 men and 3 women; mean age, 51.6; range, 27 to 85 years) affected by keratocysts (n = 6), dentigerous cysts (n = 6), and radicular cysts (n = 3) who had undergone marsupialization. The median duration of marsupialization was 406 days (25th to 75th percentile, 276 to 519). The mean ± standard deviation (SD) pre- and postdecompression volumes were 6,908.27 ± 2,669.058 and 2,468.13 ± 1,343.517 mm3, respectively (P < 0.001), and the mean ± SD percentage of reduction was 63.90 ± 13.12%. The volume decrease in the bone defects correlated positively with the treatment duration (P = .009) and preoperative volume (P < .001). However, no correlation was found with the other variables (P > .05) nor between the daily reduction rate and other variables (P > .05). CONCLUSIONS: Marsupialization appears useful in improving the healing of cyst-related bone defects in mandibles, especially larger defects. Further studies with a wider sample size would add more knowledge to this topic.


Assuntos
Cisto Dentígero/cirurgia , Cistos Odontogênicos/cirurgia , Cisto Radicular/cirurgia , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Mandíbula , Pessoa de Meia-Idade , Estudos Retrospectivos , Cicatrização
19.
Artigo em Inglês | MEDLINE | ID: mdl-32213873

RESUMO

AIM: the aim of this in vitro study was to test whether the implant placement accuracy and the operating time can be influenced by the operator's experience. MATERIALS AND METHODS: sixteen models underwent a (Cone Beam Computer Tomography) CBCT and implant positioning was digitally planned on this. The models were randomly assigned to four operators with different levels of surgical experience. One hundred and twelve implant sites were drilled using a dynamic navigation system and operating times were measured. Based on postoperative CBCTs, dental implants were virtually inserted and superimposed over the planned ones. Two-dimensional and 3D deviations between planned and virtually inserted implants were measured at the entry point and at the apical point. Angular and vertical errors were also calculated. RESULTS: considering coronal and apical 3D deviations, no statistically significant differences were found between the four operators (p = 0.27; p = 0.06). Some vectorial components of the deviation at the apical point and the angular errors of some operators differed from each other. CONCLUSIONS: within the limitations of this study, dynamic navigation can be considered a reliable technique both for experienced and novice clinicians.


Assuntos
Implantes Dentários , Modelos Dentários , Duração da Cirurgia , Cirurgia Assistida por Computador , Tomografia Computadorizada de Feixe Cônico , Humanos , Projetos de Pesquisa
20.
BMC Oral Health ; 19(1): 158, 2019 07 19.
Artigo em Inglês | MEDLINE | ID: mdl-31324246

RESUMO

BACKGROUND: Despite the limited number of articles dedicated to its use, augmented reality (AR) is an emerging technology that has shown to have increasing applications in multiple different medical sectors. These include, but are not limited to, the Maxillo-facial and Dentistry disciplines of medicine. In these medical specialties, the focus of AR technology is to achieve a more visible surgical field during an operation. Currently, this goal is brought about by an accurate display of either static or dynamic diagnostic images via the use of a visor or specific glasses. The objective of this study is to evaluate the feasibility of using a virtual display for dynamic navigation via AR. The secondary outcome is to evaluate if the use of this technology could affect the accuracy of dynamic navigation. CASE PRESENTATION: Two patients, both needing implant rehabilitation in the upper premolar area, were treated with flapless surgery. Prior to the procedure itself, the position of the implant was virtually planned and placed for each of the patients using their previous scans. This placement preparation contributed to a dynamic navigation system that was displayed on AR glasses. This, in turn, allowed for the use of a computer-aided/image-guided procedure to occur. Dedicated software for surface superimposition was then used to match the planned position of the implant and the real one obtained from the postoperative scan. Accuracies, using this procedure were evaluated by way of measuring the deviation between real and planned positions of the implants. For both surgeries it was possible to proceed using the AR technology as planned. The deviations for the first implant were 0.53 mm at the entry point and 0.50 mm at the apical point and for the second implant were 0.46 mm at the entry point and 0.48 mm at the apical point. The angular deviations were respectively 3.05° and 2.19°. CONCLUSIONS: From the results of this pilot study, it seems that AR can be useful in dental implantology for displaying dynamic navigation systems. While this technology did not seem to noticeably affect the accuracy of the procedure, specific software applications should further optimize the results.


Assuntos
Implantes Dentários , Cirurgia Assistida por Computador , Implantação Dentária Endóssea , Humanos , Imageamento Tridimensional , Projetos Piloto , Software
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA