1.
Environ Int ; 171: 107621, 2023 01.
Artigo em Inglês | MEDLINE | ID: mdl-36493608

RESUMO

The Copenhagen Metro comprises four lines, the M1, M2, M3 and M4, with 25 subterranean stations and an additional 14 stations above ground, serving ca. 80 million passengers annually. In this study we measure fine particulate matter (PM2.5) and carbon dioxide (CO2) concentrations in stations and in trains across the entire system. In partially underground lines, high PM2.5 concentrations with an average of 109 µg m-3 are found in below-ground stations. The observed correlation between PM2.5 concentration and distance between a station and a tunnel exit is attributed to ventilation via the piston effect. The piston effect via tunnel draught relief shafts was therefore found to be relatively limited. Filter samples of particulate matter are analysed using particle-induced X-ray emission and show an iron content of 88.6 % by mass which is quite different from above-ground particulate matter and consistent with particle production by train wheels, rails and brakes. The average concentration measured at the stations of a recently opened (2019) fully underground M3 closed loop line is 168 µg m-3, further demonstrating that while piston effect-driven ventilation is effective in close proximity to tunnel openings, it is relatively limited via tunnel draught relief shafts. Measurements onboard trains show even higher PM2.5 concentrations and the patterns in CO2 concentrations suggest carriage ventilation by tunnel air. Ventilation via doors during platform stops caused a drop in observed PM (and CO2) at stations, but the system is surprisingly polluted despite its recent construction. CO2 mixing ratios ranged from ambient to around 600 ppm. Measures should be taken to control PM levels using a combination of source control and increased clean air supply of the Copenhagen and other similar metro systems.


Assuntos
Poluentes Atmosféricos , Poluição do Ar em Ambientes Fechados , Poluição do Ar , Poluentes Atmosféricos/análise , Tamanho da Partícula , Poluição do Ar em Ambientes Fechados/análise , Dióxido de Carbono/análise , Monitoramento Ambiental , Poluição do Ar/análise , Material Particulado/análise , Poeira/análise , Ventilação
2.
Environ Int ; 170: 107645, 2022 12.
Artigo em Inglês | MEDLINE | ID: mdl-36434885

RESUMO

In this study fine particulate matter (PM2.5) levels throughout the Copenhagen metro system are measured for the first time and found to be ∼10 times the roadside levels in Copenhagen. In this Part 2 article, low-cost sensor (LCS) nodes designed for personal-exposure monitoring are tested against a conventional mid-range device (TSI DustTrak), and gravimetric methods. The nodes were found to be effective for personal exposure measurements inside the metro system, with R2 values of > 0.8 at 1-min and > 0.9 at 5-min time-resolution, with an average slope of 1.01 in both cases, in comparison to the reference, which is impressive for this dynamic environment. Micro-environment (ME) classification techniques are also developed and tested, involving the use of auxiliary sensors, measuring light, carbon dioxide, humidity, temperature and motion. The output from these sensors is used to distinguish between specific MEs, namely, being aboard trains travelling above- or under- ground, with 83 % accuracy, and determining whether sensors were aboard a train or stationary at a platform with 92 % accuracy. This information was used to show a 143 % increase in mean PM2.5 concentration for underground sections relative to overground, and 22 % increase for train vs. platform measurements. The ME classification method can also be used to improve calibration models, assist in accurate exposure assessment based on detailed time-activity patterns, and facilitate field studies that do not require personnel to record time-activity diaries.


Assuntos
Poluição do Ar