Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
1.
Clin Oral Investig ; 27(11): 6559-6566, 2023 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-37733026

RESUMO

OBJECTIVE: Compare heart rate variability (HRV) indices in participants with and without myogenic temporomandibular disorder (TMD). Secondarily, we correlated HRV indices with pain and quality of life variables. METHODS: This is a comparative observational cross-sectional study. Individuals of both genders with and without a history of TMD were included. Short-term heart rate variability was assessed using a Polar V800. Central sensitization was assessed using the Central Sensitization Inventory. Pain through the numeric pain scale and the impact of oral health on quality of life using the OHIP-14 questionnaire. RESULTS: A total of 80 participants were enrolled in the study: most individuals included in both groups were young adults, women and slightly overweight. We observed a decrease in HRV in the TMD group (p < 0.01) when compared to the control group. In addition, we observed a greater impact of oral health on quality of life, central sensitization in addition to high resting pain scores (p < 0.01). We observed significant correlation between the LF index of HRV and the FAI score (r = 0.311; p = 0.05). The NPS, CSI and OHIP-14 scores did not correlate with any of the HRV indices (p > 0.05). CONCLUSION: The short-term HRV in individuals with TMD is significantly lower when compared to a control group. Furthermore, there seems to be a relationship between the severity of the dysfunction and the HRV variables. CLINICAL RELEVANCE: Using portable and low-cost devices, the HRV can be easily collected and analyzed, without the need for an arsenal of equipment such as the conventional electrocardiogram. This measure can contribute to the therapy adopted and identify individuals prone to unfavorable outcomes involving ANS modulation.


Assuntos
Qualidade de Vida , Transtornos da Articulação Temporomandibular , Feminino , Humanos , Masculino , Adulto Jovem , Estudos Transversais , Frequência Cardíaca/fisiologia , Dor
2.
J Clin Exp Dent ; 14(6): e486-e491, 2022 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-35765359

RESUMO

Background: New protocols are constantly being tested in the search for complete disinfection of root canals without the undesirable effects of sodium hypochlorite. This study evaluated the antimicrobial effect of ozonated water and photodynamic therapy (PDT) with sonic activation in root canals infected with Enterococcus faecalis. Material and Methods: Seventy single-rooted canals of human teeth were prepared and contaminated with E. faecalis for 21 days. The teeth were divided into six experimental groups (n=10): ozonized water without (O + S-) and with sonic activation (O + S +); PDT without (PDT + S-) and with sonic activation (PDT + S +); PDT + ozonized water without (PDT + O + S-) and with sonic activation (PDT + O + S +); and two control groups, one positive (n = 5) and one negative (n = 5). Microbial collections were performed before and shortly after treatment, counted in the log of colony-forming units and tested for significant difference between these counts, if any (Student's t-test). The ANOVA two-way test was applied to evaluate whether the Treatment factor (Ozone, PDT and Ozone + PDT) and the Sonic factor (With and without sonic activation) had any effect on microbial reduction. Results: In all protocols, there was a significant microbial reduction (p=0.025), whereas in the groups in which sonic activation was used, the microbial reduction was significantly greater (p=0.001). Conclusions: The treatments significantly reduced the number of microorganisms in the root canals. Sonic activation helped to increase the microbial reduction in infected root canals. Key words:Endodontics, ozone, photodynamic therapy, enterococcus faecalis.

3.
J Dent ; 115: 103857, 2021 12.
Artigo em Inglês | MEDLINE | ID: mdl-34699954

RESUMO

OBJECTIVES: This randomized clinical trial compares retention, survival rate, and evolution of caries of newly erupted permanent molars sealed with bioactive self-etching sealants with pre-reacted glass ionomer (S-PRG). METHODS: A split-mouth clinical trial was conducted with 56 permanent second molars in stages 2 and 3 of crown eruption; ICDAS (International Caries Detection and Assessment System) was between 0 and 2. The molars were randomized and blinded in relation to the side (right or left) that would receive the sealants; the conventional resin sealant (FS), Fluroshield (Dentsply), or bioactive self-etch sealant (BS), BeautiSealant with S-PRG (Shofu). The sealants were compared in terms of retention, quality of sealant remnant (anatomical shape, marginal adaptation, surface texture, and marginal discoloration), and development of caries by ICDAS after 1, 6, and 12 months. The Wilcoxon, x² of independence, Kaplan-Meier, and Mantel-Cox survival statistical tests were applied (α = 5%). RESULTS: The total retention was higher for FS (57.1%) at all periods, and there was no difference in the quality of sealants at all periods. The ICDAS decreased after 6 (p = 0.025) and 12 months (p = 0.027) for both materials. Despite the lower retention of BS, the clinical quality of sealants over 12 months were similar. CONCLUSION: Teeth sealed with BS presented higher sound teeth predominance (ICDAS 0) compared to FS sealant, even with a higher loss of material. CLINICAL RELEVANCE: Eruption of permanent molars is a relevant period, and the prevention/management of initial caries is essential in these critical stages. Sealants can be an important prevention strategy. After 12 months of follow-up, there was a major failure of the bioactive sealant but without the development of caries lesions.


Assuntos
Cárie Dentária , Selantes de Fossas e Fissuras , Cárie Dentária/prevenção & controle , Face , Humanos , Dente Molar , Selantes de Fossas e Fissuras/uso terapêutico , Erupção Dentária
4.
J Contemp Dent Pract ; 17(3): 235-9, 2016 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-27207204

RESUMO

OBJECTIVE: The aim of this study was to evaluate the association between tooth loss and the signs and symptoms of temporomandibular disorders (TMDs). MATERIALS AND METHODS: One hundred fifty patients with an average age of 49.2 (±14.06) years were divided into three groups (n = 50/group) according to the degree of tooth loss: GI (dentate -control), GII (edentulous), GIII (partially dentate). After performing anamnesis and clinical examination, a questionnaire was used, so that the patients could fill in information on signs and symptoms of TMD. After analyzing this information, it was possible to classify the degree of severity of TMD. As age is a confounding variable to the level of TMD, an analysis of covariance (ANCOVA) was used to check for differences in the degree of TMD between groups (covariate = age). A post hoc test (Bonferroni) was performed to compare the groups two by two (5% significance level). RESULTS: The mean level of TMD according to the groups was GI - 1.95; GII - 2.15; GIII - 2.55. There were significant differences between the study groups (p > 0.05). A post hoc test (Bonferroni) confirmed the difference between edentulous patients and the other groups. CONCLUSION: The tooth loss is directly related to the signs and symptoms of TMD. The degree of TMD was significantly higher in edentulous patients.


Assuntos
Transtornos da Articulação Temporomandibular/etiologia , Perda de Dente/complicações , Humanos , Pessoa de Meia-Idade , Inquéritos e Questionários
5.
J Contemp Dent Pract ; 16(8): 643-7, 2015 08 01.
Artigo em Inglês | MEDLINE | ID: mdl-26423500

RESUMO

OBJECTIVE: The aim of this in vivo study was to radiographically evaluate the proximal contour of composite resin restorations performed using different matrix systems. MATERIALS AND METHODS: Patients with premolars needing class II type resin composite restorations involving the marginal ridge were selected. Thirty premolars were selected and randomly divided into three groups (n = 10 each) to receive restorations using different matrix systems: group 1: metal matrix coupled to a carrier matrix and wood wedge (G1-MMW); group 2: sectioned and precontoured metal matrix and elastic wedge (G2-SME); and group 3: a polyester strip and reflective wedge (G3-PMR). After the restorative procedure, bitewing radiographs were performed and analyzed by three calibrated professionals. The quality of the proximal contact and marginal adaptation of the proximal surfaces was classified as either correct or incorrect (undercontour/overcontour). RESULTS: The Pearson Chi-square statistical test (α = 5%) revealed a statistically difference between frequencies of correct and incorrect restorations (α(2) = 6.787, p < 0.05). The group G2 SME produced a higher frequency of correct proximal contours (90%), while G1-MMW and G3-PMR had a ratio of 40% correct and 60% incorrect contours respectively. CONCLUSION: None of the matrix systems was able to prevent the formation of incorrect proximal contours; however, the sectioned and precontoured metal matrix/elastic wedge configuration provided better results as compared to the other groups.


Assuntos
Dente Pré-Molar/cirurgia , Resinas Compostas/química , Ligas Dentárias/química , Materiais Dentários/química , Restauração Dentária Permanente/classificação , Bandas de Matriz/classificação , Adulto , Dente Pré-Molar/lesões , Colagem Dentária , Preparo da Cavidade Dentária , Adaptação Marginal Dentária , Restauração Dentária Permanente/instrumentação , Feminino , Humanos , Masculino , Propriedades de Superfície
6.
J Contemp Dent Pract ; 16(7): 559-64, 2015 07 01.
Artigo em Inglês | MEDLINE | ID: mdl-26329411

RESUMO

This study evaluated the influence of relining fiber posts on the bond strength (BS) of resin cements in the root canal. Forty bovine teeth were divided in four groups (n = 10): G1 (ARC)-fiber post cemented with resin cement RelyX ARC; G2 (ARC+Z350)-relined fiber post cemented with RelyX ARC; G3 (U200)-fiber post cemented with self-adhesive cement RelyX U200; G4 (U200+Z350)-relined fiber post cemented with RelyX U200. The roots were sectioned in six 1.2-mm slices and the push-out test was performed. Data were analyzed by three-way analysis of variance (ANOVA), and Tukey's test (a = 0.05). For the conventional resin cement, there was no significant difference between groups G1-ARC (15.5 ± 3.8) and G2-ARC+Z350 (16.1 ± 4.5). For the self-adhesive cement, the results revealed higher BS values for relined posts G4-U200 + Z350 (19.9 ± 7.9) as compared to non-relined posts G3-U200 (14.4 ± 4.5). For both cements, in groups of relined posts, the apical and the cervical thirds presented similar BS. Relining enhances the performance of the self-adhesive resin cement, and the interaction between relining and root third influences the BS to the conventional resin cement.


Assuntos
Colagem Dentária , Técnica para Retentor Intrarradicular/instrumentação , Cimentos de Resina/química , Animais , Bis-Fenol A-Glicidil Metacrilato/química , Bovinos , Cimentação/métodos , Resinas Compostas/química , Materiais Dentários/química , Cavidade Pulpar/ultraestrutura , Dentina/ultraestrutura , Vidro/química , Polietilenoglicóis/química , Ácidos Polimetacrílicos/química , Distribuição Aleatória , Preparo de Canal Radicular/métodos , Estresse Mecânico , Propriedades de Superfície
7.
J Contemp Dent Pract ; 16(2): 91-5, 2015 02 01.
Artigo em Inglês | MEDLINE | ID: mdl-25906797

RESUMO

OBJECTIVE: This study evaluated in vitro the mechanical changes of 0.018" (0.45 mm) and 0.016 × 0.022" (0.40 × 0.55 mm) thermoactivated nickel-titanium archwires subjected to heat treatment on their distal ends. MATERIALS AND METHODS: Ten archwires in diameters 0.018" and 0.016 × 0.022" by different manufacturers Ormco, Morelli, Orthometric and Unitek were tested. Each tested archwire had an experimental side, submitted to heat treatment, and an annealing-free control. Tests for load/deflection were performed using a universal testing machine, with temperature control in the austenitic transformation phase through tempe rature-controlled chamber. The variables showed normal distribution (Kolmogorov-Smirnov), the t-student test was applied in order to observe the difference between the experi mental and control groups. Statistical significance was set at p < 0.05. RESULTS: There were no statistically significant differences between the groups. CONCLUSION: Heat treatment carried out in the region corresponding to the first molar distal region on thermoactivated nickel-titanium archwires did not influence the load/deflection values in adjacent portion.


Assuntos
Ligas Dentárias/química , Níquel/química , Fios Ortodônticos , Titânio/química , Análise do Estresse Dentário/instrumentação , Elasticidade , Temperatura Alta , Humanos , Teste de Materiais , Desenho de Aparelho Ortodôntico , Braquetes Ortodônticos , Transição de Fase , Estresse Mecânico , Propriedades de Superfície
8.
J Contemp Dent Pract ; 15(4): 456-60, 2014 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-25576113

RESUMO

This in vitro study evaluated the Influence of prestretching, in the force decay of orthodontic elastic chains, at three time intervals: 2, 7 and 30 days with the brands Morelli, Orthometric and American Orthodontics. In the experimental group, prestretching was performed, stretching the elastics to increase them by 50% of their original length three times in a quick and sequential mode. All of the elastic chains were kept stretched and stored in artificial saliva at 37°C until the time of force measurement. For comparisons between the control and experimental groups, the Mann-Whitney test was used. For comparisons between time points and brands, the Kruskal-Wallis test was used, and for multiple comparisons, Miller's post-hoc test was used. The results showed statistically significant differences among the different commercial brands tested at the initial time point. The mean force at the initial time point ranged from 2.57 to 3.17 N. By day 2, the force values were between 0.97 and 1.49 N; by day 7, the values were 0.56 and 0.94 N. By day 30, the force values ranged between 0.27 and 0.66 N. We concluded that performing and duration of prestretching and the brand all Influenced the force decay of orthodontic elastic chains. Time had a greater Influence on the decay of the elastics than brand or prestretching.


Assuntos
Materiais Dentários/química , Elastômeros/química , Aparelhos Ortodônticos , Elasticidade , Humanos , Teste de Materiais , Saliva Artificial/química , Estresse Mecânico , Propriedades de Superfície , Temperatura , Fatores de Tempo
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA