Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
1.
Nucl Med Biol ; 104-105: 22-27, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-34847480

RESUMO

INTRODUCTION: 44Sc is of great interest as a positron emission tomography (PET) radionuclide due to its suitable nuclear characteristics: Eß+max = 1.47 MeV, branching ratio 94.3% and convenient half-life of 3.97 h. Here, 44Sc was produced via the widely used reaction 44Ca (p,n)44Sc using natural calcium as a target. METHODS: The irradiation was performed at TRIUMF using the 13 MeV cyclotron. The separation consisted of a combination of DGA branched resin and Dowex 50Wx8 (200-400 mesh). The distribution coefficients of Sc3+ on Dowex 50Wx8 (NH4+ form, 200-400 mesh) with ammonium α-hydroxyisobutyrate (pH = 4.8) medium were determined in this study. RESULTS AND CONCLUSION: The tested scheme allows both a reliable separation of 44Sc from the target material as well as from the other competitive metals and a final fraction with high specific activity. The achieved radiochemical yield was 95 ± 3%.


Assuntos
Prótons , Escândio , Ciclotrons , Marcação por Isótopo/métodos , Radioisótopos
2.
Phys Rev Lett ; 125(14): 141301, 2020 Oct 02.
Artigo em Inglês | MEDLINE | ID: mdl-33064531

RESUMO

We present the first Ge-based constraints on sub-MeV/c^{2} dark matter (DM) particles interacting with electrons using a 33.4 g Ge cryogenic detector with a 0.53 electron-hole pair (rms) resolution, operated underground at the Laboratoire Souterrain de Modane. Competitive constraints are set on the DM-electron scattering cross section, as well as on the kinetic mixing parameter of dark photons down to 1 eV/c^{2}. In particular, the most stringent limits are set for dark photon DM in the 6 to 9 eV/c^{2} range. These results demonstrate the high relevance of Ge cryogenic detectors for the search of DM-induced eV-scale electron signals.

3.
Appl Radiat Isot ; 123: 54-59, 2017 May.
Artigo em Inglês | MEDLINE | ID: mdl-28242294

RESUMO

The BiPo-3 detector is a low radioactive detector dedicated to measuring ultra-low natural contaminations of 208Tl and 214Bi in thin materials, initially developed to measure the radiopurity of the double ß decay source foils of the SuperNEMO experiment at the µBq/kg level. The BiPo-3 technique consists in installing the foil of interest between two thin ultra-radiopure scintillators coupled to low radioactive photomultipliers. The design and performances of the detector are presented. In this paper, the final results of the 208Tl and 214Bi activity measurements of the first enriched 82Se foils are reported for the first time, showing the capability of the detector to reach sensitivities in the range of some µBq/kg.

4.
Phys Rev Lett ; 119(4): 041801, 2017 Jul 28.
Artigo em Inglês | MEDLINE | ID: mdl-29341770

RESUMO

We report the results of a first experimental search for lepton number violation by four units in the neutrinoless quadruple-ß decay of ^{150}Nd using a total exposure of 0.19 kg yr recorded with the NEMO-3 detector at the Modane Underground Laboratory. We find no evidence of this decay and set lower limits on the half-life in the range T_{1/2}>(1.1-3.2)×10^{21} yr at the 90% C.L., depending on the model used for the kinematic distributions of the emitted electrons.

5.
Appl Radiat Isot ; 69(7): 942-6, 2011 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-21420306

RESUMO

An improved chemical strategy for processing of the generator produced (68)Ga was developed based on processing of the original (68)Ge/(68)Ga generator eluate on a micro-column. Direct pre-concentration and purification of the eluted (68)Ga is performed on a cation-exchange resin in hydrochloric acid/acetone media. A supplementary step based on a second micro-column filled with a second resin allows direct re-adsorption of (68)Ga eluted from the cation exchanger. (68)Ga is finally striped from the second resin with a small volume of pure water. For this purpose a strong anion exchanger and a novel extraction chromatographic resin based on tetraalkyldiglycolamides are characterized. The strategy allows online pre-concentration and purification of (68)Ga from the original generator eluate. The supplementary column allows transferring (68)Ga with high radionuclide and chemical quality in the aqueous solution with small volume and low acidity useful for direct radiolabeling reactions.

6.
Appl Radiat Isot ; 68(9): 1636-41, 2010 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-20434351

RESUMO

The (44)Ti/(44)Sc (T(1/2)(44)Ti=60a) generator provides cyclotron-independent access to positron-emitting (44)Sc (T(1/2)=3.97d) for PET imaging. This work aims to post-elution processing of initial (44)Sc generator eluates in order to reduce its volume, HCl concentration and remove the oxalate anions. The on-line adsorption of (44)Sc on cationic resin AG 50W-X8 (200-400 mesh, H(+)-form) is achieved with >98% efficacy. Subsequently, the purified (44)Sc is desorbed by using 3ml of 0.25M ammonium acetate (pH=4.0). The post-processing takes 10min. The overall yield of the post-processing reached 90%, which is referred to the (44)Sc obtained from the (44)Ti/(44)Sc generator. In addition to the chemical purification, the content of (44)Ti breakthrough was further reduced by one order of magnitude. The 185MBq generator finally provides 150MBq of (44)Sc containing <10Bq of (44)Ti ready for labeling.


Assuntos
Tomografia por Emissão de Pósitrons/métodos , Radioisótopos/química , Radioisótopos/isolamento & purificação , Compostos Radiofarmacêuticos/síntese química , Compostos Radiofarmacêuticos/isolamento & purificação , Escândio/química , Escândio/isolamento & purificação , Titânio/química , Marcação por Isótopo/métodos , Titânio/isolamento & purificação
8.
Appl Radiat Isot ; 62(3): 451-6, 2005 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-15607923

RESUMO

The low-energy electron spectra generated in the decay of 140Nd have been measured using a combined electrostatic spectrometer adjusted to the 4, 7, and 35 eV instrumental resolution. In order to estimate the therapeutic potential of low-energy electrons associated with the decay of 140Nd, similar experiments have been performed with 111In. Relative Auger electron intensity ratios per decay are: 111In(K-Auger)/140Nd(K-Auger)=1.47(12), 111In(L-Auger) /140Nd(L-Auger)=1.1(4), and 111In(L-Auger [2.8-7 keV])/140Nd(L-Auger [2.8-7 keV])=0.24(11). The obtained K-Auger group intensity ratios have been compared with results of calculations. The good agreement found for the experimental and estimated values indicates that such information can be also derived using available nuclear and atomic data. The relative intensity of L-Auger electrons emitted within the 2.8-7 keV interval is higher for 140Nd by a factor of about 4 compared to 111In. As the L-Auger emission is dominating relative to that of the K-Auger group, this implicates that any potential endotherapeutic strategy using 140Nd-labelled targeting vectors requires a maximum accumulation of the endoradiotherapeutical close to the cell nucleus or the DNA of the tumour cell.


Assuntos
Neodímio/química , Radioisótopos/química , DNA de Neoplasias/efeitos da radiação , Neodímio/farmacologia , Radioisótopos/farmacologia , Neoplasias de Tecidos Moles/radioterapia , Análise Espectral
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA