Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
1.
Case Rep Pulmonol ; 2015: 876904, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-26634166

RESUMO

Idiopathic pulmonary hemosiderosis (IPH) is a rare cause of alveolar hemorrhage in children but should be considered in children with anemia of unknown origin who develop respiratory complications. It is commonly characterized by the triad of recurrent hemoptysis, diffuse parenchymal infiltrates, and iron-deficiency anemia. Pathogenesis is unclear and diagnosis may be difficult along with a variable clinical course. A 6-year-old boy was admitted to the hospital with a severe iron-deficiency anemia, but he later developed severe acute respiratory failure and hemoptysis requiring intubation and mechanical ventilation. The suspicion of IPH led to the use of immunosuppressive therapy with high dose of corticosteroids with rapid improvement in clinical condition and discharge from hospital.

2.
Anaesthesia ; 67(4): 384-8, 2012 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-22329593

RESUMO

Two new supraglottic airway devices, the LMA Supreme™ (LMA) and the i-gel™, offer potential benefits when inserted by inexperienced operators. This study compared the insertion success rate and ventilation profile between the LMA Supreme and the i-gel when inserted by operators without previous airway management expertise. Following a short lecture and manikin training, airway novices were randomly allocated to insert either the LMA Supreme or the i-gel into 80 patients undergoing breast surgery. The primary outcome was first-time success rate, and secondary outcomes were overall success rate, insertion time, airway leak pressure, tidal volume during pressure controlled ventilation at 17 cmH(2)O, and adverse events. First-time insertion success rate was significantly higher for the LMA Supreme than the i-gel (30/39 (77%) vs 22/41 (54%); p = 0.029). Significantly more placement failures occurred with the i-gel (6 vs 0, p = 0.025). Mean (SD) leak pressure (29 (8) vs 23 (11) cmH(2)O, p = 0.007) and expired tidal volume (PCV 17 cmH(2)O) (785 (198) vs 654 (91), p = 0.001) were significantly greater with the LMA Supreme than with the i-gel, respectively. More patients complained of pharyngolaryngeal pain with the LMA Supreme than with the i-gel (17/39 (44%) vs 8/41 (20%); p = 0.053). We found better first time success rate, fewer failures, and a better seal with the LMA Supreme compared with the i-gel, indicating that the LMA Supreme may be preferable for emergency airway use by novices.


Assuntos
Competência Clínica , Ventilação com Pressão Positiva Intermitente/instrumentação , Máscaras Laríngeas/estatística & dados numéricos , Adulto , Anestesia Geral , Mama/cirurgia , Equipamentos Descartáveis , Desenho de Equipamento , Feminino , Humanos , Máscaras Laríngeas/efeitos adversos , Dor/etiologia , Satisfação do Paciente , Estudos Prospectivos , Volume de Ventilação Pulmonar
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA