Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 23
Filtrar
1.
J Pers Med ; 14(7)2024 Jun 26.
Artigo em Inglês | MEDLINE | ID: mdl-39063940

RESUMO

Osteoarthritis (OA) of the knee is a prevalent cause of chronic pain and disability, particularly affecting women. While traditionally attributed to chronic wear and tear, recent evidence highlights multifactorial pathogenesis involving low-grade inflammation and neoangiogenesis. Current therapeutic options include physical therapy, pharmacotherapy, and total knee arthroplasty (TKA). However, a subset of patients remain symptomatic despite conservative measures, necessitating the development of minimally invasive interventions. Genicular artery embolization (GAE) emerges as a promising option, targeting neovascularization and inflammatory processes in OA. This paper reviews the pathophysiological basis, patient selection criteria, procedural details, and outcomes of GAE. Notably, GAE demonstrates efficacy in relieving knee pain and improving function in patients refractory to conventional therapy. While further research is warranted to elucidate its long-term outcomes and compare it with existing modalities, GAE represents a novel approach in the management of symptomatic knee OA, potentially delaying or obviating the need for surgical intervention. Here, we synthesize the relevant literature, technical details of the procedure, and future perspectives. Moreover, the success of GAE prompts the exploration of transarterial embolization in other musculoskeletal conditions, underscoring the evolving role of interventional radiology in personalized pain management strategies.

2.
BJUI Compass ; 5(4): 466-472, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38633831

RESUMO

Objectives: To compare surgical and functional outcomes between off-clamp robot-assisted partial nephrectomy with indocyanine-green tumour marking through preliminary superselective embolization and on-clamp robot-assisted partial nephrectomy with intraoperative ultrasound identification of the renal mass. Material and methods: One hundred and forty patients with a single renal mass underwent indocyanine-green fluorescence-guided off-clamp robot-assisted partial nephrectomy with preoperative superselective embolization (Group A, 70 patients) versus intraoperative ultrasound-guided on-clamp robot-assisted partial nephrectomy without embolization (Group B, 70 patients). We assessed operative time, intraoperative blood loss, complications, length of stay, renal function, need for ancillary procedures and blood transfusions. Results: Mean tumour size was 24 versus 25 mm in Group A versus Group B (p = 0.19). Mean operative time was 86.5 versus 121.8 min (p = 0.02), mean blood loss was 72.8 versus 214.2 mL (p = 0.02), and mean haemoglobin drop on postoperative day 1 was 1.1 versus 2.6 g/dL (p = 0.04) in Group A versus Group B. One-month creatinine, hospital stay and enucleated tumour volume were comparable. Ten postoperative complications occurred in Group A (13.3%) and 11 in Group B (15.3%). Following superselective embolization, no patients required blood transfusions versus two patients in Group B. Postoperative selective renal embolization was needed in one case per group. Conclusions: Preoperative superselective embolization of a renal mass with indocyanine-green before off-clamp robot-assisted partial nephrectomy significantly reduces operative time and intraoperative blood loss compared to on-clamp intraoperative ultrasound-guided robot-assisted partial nephrectomy. A longer follow-up is needed to establish the effect on renal function.

3.
Radiol Case Rep ; 19(6): 2277-2281, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38559648

RESUMO

We report on a 20-year-old pregnant woman who tested positive for SARS-CoV-2 and was diagnosed with KILT syndrome, a rare condition that increases the risk of thrombotic events. The patient showed signs of deep vein thrombosis that extended from the bilateral iliac vein to the inferior vena cava (IVC), which was treated with placement of an IVC filter and endovascular thromboaspiration/thrombolysis. The IVC was successfully recanalized; however, during follow-up, thrombotic restenosis occurred at the filter level, requiring filter removal. This case highlights the potential benefits of endovascular thromboaspiration/thrombolysis and IVC filter placement in patients with KILT syndrome presenting with acute thrombotic events.

4.
Radiol Case Rep ; 19(3): 890-894, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38188956

RESUMO

We report a case of a 40-year-old female with a solitary plasmacytoma of the right transverse apophysis of C1 who underwent combined transoral ablation using a curved steerable needle and cementoplasty under CBCT and infra-red augmented reality navigation system. An imaging work-up revealed an osteolytic lesion determining partial collapse of the right lateral mass of C1 and involving the vertebral foramen. After a biopsy, that revealed a solid tissue consistent with plasmacytoma, it was decided to proceed with radiation therapy. Subsequent PET-CT restaging scans showed residual tumors treated with a transoral percutaneous approach, combining ablation and cementoplasty. This report evaluates the benefits of this combined procedure and the transoral approach, focusing on the advantages of steerable devices and navigation systems.

5.
Tomography ; 9(3): 1083-1093, 2023 05 28.
Artigo em Inglês | MEDLINE | ID: mdl-37368541

RESUMO

The aim of this study is to report the authors' experience of percutaneous transarterial embolization (TAE) in patients with spontaneous soft tissue hematomas (SSTH) and active bleeding with anticoagulation impairment. The study retrospectively identified 78 patients who received a diagnosis of SSTH by CT scan and underwent TAE between 2010 and 2019 in a single trauma center. The patients were stratified using Popov classification into categories: 2A, 2B, 2C, and 3. The patient's 30-day survival after TAE was considered the primary outcome; immediate technical success, the need for additional TAE, and TAE-related complications were considered secondary outcomes. Immediate technical success, complication rate, and risk factors for death were analyzed. Follow-up stopped on day 30 from TAE. 27 patients (35%) fell into category 2A, 8 (10%) into category 2B, 4 (5%) into category 2C, and 39 (50%) into category 3. Immediate technical success was achieved in 77 patients (98.7%). Complications included damage at the arterial puncture site (2 patients, 2.5%) and acute kidney injury (24 patients, 31%). Only 2 patients (2.5%) had been discharged with a new diagnosis of chronic kidney disease. The 30-day overall mortality rate was 19% (15 patients). The mortality rate was higher in hemodynamically unstable patients, in Popov categories 2B, 2C, and 3, and in patients with an initial eGFR < 30 mL/min × 1.73 m2. The study demonstrated a higher mortality risk for categories 2B, 2C, and 3 compared to category 2A. Nonetheless, TAE has proven effective and safe in type 2A patients. Even though it is unclear whether type 2A patients could benefit from conservative treatment rather than TAE, in the authors' opinion, a TAE endovascular approach should be promptly considered for all patients in ACT with active bleeding demonstrated on CT scans.


Assuntos
Embolização Terapêutica , Humanos , Estudos Retrospectivos , Resultado do Tratamento , Embolização Terapêutica/efeitos adversos , Tomografia Computadorizada por Raios X , Hematoma/diagnóstico por imagem , Hematoma/etiologia , Hematoma/terapia
6.
Case Rep Otolaryngol ; 2023: 1351982, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37181231

RESUMO

Background: Juvenile nasopharyngeal angiofibroma (JNA) is a rare tumor that mainly affects young boys. Its intervention may be complex due to its high vascularity, location, and extension. Preoperative embolization is used to prevent intrasurgical and postsurgical bleeding. Two main kinds of embolization are described in literature: intratumoral and transarterial, and numerous embolic materials are used. Case Presentation. We want to present a case of presurgical embolization of a stage IV JNA, performed using a single stop-flow balloon assisted technique with the balloon cuffed exclusively in the external carotid artery and using Onyx 18 as an embolic agent. Conclusions: The embolization with an exclusive external carotid artery single stop-flow technique using Onyx 18 is a safe, effective, and a definitive approach.

7.
J Clin Med ; 11(19)2022 Sep 22.
Artigo em Inglês | MEDLINE | ID: mdl-36233437

RESUMO

(1) Background: The aim of this review was to determine the state of clinical practice in the role of the combined approach of embolization and ablation in patients with secondary liver lesions greater than 3 cm who are not candidates for surgery, and to study its safety and efficacy. (2) Methods: Two reviewers conducted the literature search independently. Eight articles on the combined approach of embolization and ablation in secondary liver lesions were selected. (3) Results: The studies were published between 2009 and 2020. Two studies were prospective in design. The sample size was < 100 patients for all studies. All studies demonstrated the safety of the combined approach based on the low complication rate. Some studies lamented non-uniform systemic chemotherapy regimens and the variability in the sequence of embolization and ablation. (4) Conclusions: This review presents the combined approach of ablation and embolization in liver lesions greater than 3 cm as a safe therapeutic procedure with positive effects on patient survival. Prospective and multicentric studies are needed to further evaluate its efficacy.

8.
Curr Oncol ; 29(8): 5891-5900, 2022 08 20.
Artigo em Inglês | MEDLINE | ID: mdl-36005203

RESUMO

Background: Radiofrequency ablation (RFA) and cementoplasty, individually and in concert, has been adopted as palliative interventional strategies to reduce pain caused by bone metastases and prevent skeletal related events. We aim to evaluate the feasibility and safety of a steerable RFA device with an articulating bipolar extensible electrode for the treatment of extraspinal bone metastases. Methods: All data were retrospectively reviewed. All the ablation procedures were performed using a steerable RFA device (STAR, Merit Medical Systems, Inc., South Jordan, UT, USA). The pain was assessed with a VAS score before treatment and at 1-week and 3-, 6-, and 12-month follow-up. The Functional Mobility Scale (FMS) was recorded preoperatively and 1 month after the treatment through a four-point scale (4, bedridden; 3, use of wheelchair; 2, limited painful ambulation; 1, normal ambulation). Technical success was defined as successful intraoperative ablation and cementoplasty without major complications. Results: A statistically significant reduction of the median VAS score before treatment and 1 week after RFA and cementoplasty was observed (p < 0.001). A total of 6/7 patients who used a wheelchair reported normal ambulation 1 month after treatment. All patients with limited painful ambulation reported normal ambulation after the RFA and cementoplasty (p = 0.003). Technical success was achieved in all the combined procedures. Two cement leakages were reported. No local recurrences were observed after 1 year. Conclusions: The combined treatment of RFA with a steerable device and cementoplasty is a safe, feasible, and promising clinical option for the management of painful bone metastases, challenging for morphology and location, resulting in an improvement of the quality of life of patients.


Assuntos
Neoplasias Ósseas , Ablação por Cateter , Cementoplastia , Neoplasias Ósseas/cirurgia , Ablação por Cateter/efeitos adversos , Cementoplastia/efeitos adversos , Cementoplastia/métodos , Estudos de Viabilidade , Humanos , Dor/etiologia , Qualidade de Vida , Estudos Retrospectivos , Resultado do Tratamento
9.
J Ultrasound ; 25(3): 571-577, 2022 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-35000130

RESUMO

PURPOSE: To evaluate the usefulness of compressive ultrasound (CUS) for the diagnosis of deep vein thrombosis (DVT) in patients with SARS-CoV-2-related infection. METHODS: 112 hospitalized patients with confirmed SARS-CoV-2 infection were retrospectively enrolled. CUS was performed within 2 days of admission and consisted in the assessment of the proximal and distal deep venous systems. Lack of compressibility, or direct identification of an endoluminal thrombus, were the criteria used for the diagnosis of DVT. Pulmonary embolism (PE) events were investigated at computed tomography pulmonary angiography (CTPA) within 5 days of follow-up. Logistic binary regression was computed to determine which clinical and radiological parameters were independently associated with PE onset. RESULTS: Overall, the incidence of DVT in our cohort was about 43%. The most common district involved was the left lower limb (68.7%) in comparison with the right one (58.3%) while the upper limbs were less frequently involved (4.2% the right one and 2.1% the left one, respectively). On both sides, the distal tract of the popliteal vein was the most common involved (50% right side and 45.8% left side). The presence of DVT in the distal tract of the right popliteal vein (OR = 2.444 95%CIs 1.084-16.624, p = 0.038), in the distal tract of the left popliteal vein (OR = 4.201 95%CIs 1.484-11.885, p = 0.007), and D-dimer values (OR = 2.122 95%CIs 1.030-5.495, p = 0.003) were independently associated with the onset on PE within 5 days. CONCLUSIONS: CUS should be considered a useful tool to discriminate which category of patients can develop PE within 5 days from admission.


Assuntos
COVID-19 , Embolia Pulmonar , Trombose Venosa , COVID-19/complicações , COVID-19/diagnóstico por imagem , Humanos , Embolia Pulmonar/diagnóstico por imagem , Estudos Retrospectivos , SARS-CoV-2 , Trombose Venosa/complicações , Trombose Venosa/diagnóstico por imagem
10.
Cancers (Basel) ; 13(21)2021 Oct 29.
Artigo em Inglês | MEDLINE | ID: mdl-34771602

RESUMO

Objective: The American College of Radiology (ACR) and the European Thyroid Association (EU) have proposed two scoring systems for thyroid nodule classification. Here, we compared the ability of the two systems in triaging thyroid nodules for fine-needle aspiration (FNA) and tested the putative role of an approach that combines ultrasound features and cytology for the detection of malignant nodules. Design and Methods: The scores obtained with the ACR and EU Thyroid Imaging Reporting and Data Systems (TIRADS) from a prospective series of 480 thyroid nodules acquired from 435 subjects were compared to assess their performances in FNA triaging on the final cytological diagnosis. The US features that showed the highest contribution in discriminating benign nodules from malignancies were combined with cytology to improve its diagnostic performance. Results: FNA was recommended on 46.5% and 51.9% of the nodules using the ACR and EU-TIRADS scores, respectively. The ACR system demonstrated a higher specificity as compared to the EU-TIRADS (59.0% vs. 52.4%, p = 0.0012) in predicting ≥ TIR3A/III (SIAPEC/Bethesda) nodules. Moreover, specific radiological features (i.e., echogenic foci and margins), combined with the cytological classes improved the specificity (97.5% vs. 91%, p < 0.0001) and positive predictive values (77.5% vs. 50.7%, p < 0.0001) compared to cytology alone, especially in the setting of indeterminate nodules (TIR3A/III and TIR3B/IV), maintaining an excellent sensitivity and negative predictive value. Conclusions: The ACR-TIRADS system showed a higher specificity compared to the EU-TIRADS in triaging thyroid nodules. The use of specific radiological features improved the diagnostic ability of cytology.

11.
Cancers (Basel) ; 13(9)2021 May 06.
Artigo em Inglês | MEDLINE | ID: mdl-34066485

RESUMO

Ultrasound scores are used to determine whether thyroid nodules should undergo Fine Needle Aspiration (FNA) or simple clinical follow-up. Different scores have been proposed for this task, with the American College of Radiology (ACR) TIRADS system being one of the most widely used. This study evaluates its ability in triaging thyroid nodules deserving FNA on a large prospective monocentric Italian case series of 493 thyroid nodules from 448 subjects. In ACR 1-2, cytology never prompted a surgical indication. In 59% of cases classified as TIR1c-TIR2, the FNA procedure could be ancillary, according to the ACR-TIRADS score. A subset (37.9%) of cases classified as TIR4-5 would not undergo FNA, according to the dimensional thresholds used by the ACR-TIRADS. Applying the ACR score, a total of 46.5% thyroid nodules should be studied with FNA. The ACR system demonstrated a sensitivity and specificity of 58.9% and 59% in the identification of patients with cytology ≥TIR3A, with a particularly high false negative rate for ACR classes ≥3 (44.8%, 43/96), which would dramatically decrease (7.3%, 7/96) if the dimensional criteria were not taken into account. In ACR 3-4-5, a correspondence with the follow-up occurred in 60.3%, 50.2% and 51.9% of cases. The ACR-TIRADS is a useful risk stratification tool for thyroid nodules, although the current dimensional thresholds could lead to an underestimation of malignant lesions. Their update might be considered in future studies to increase the screening performances of the system.

12.
Cardiovasc Intervent Radiol ; 42(5): 712-719, 2019 May.
Artigo em Inglês | MEDLINE | ID: mdl-30652222

RESUMO

PURPOSE: C-arm cone-beam computed tomography-guided transthoracic lung core needle biopsy (CBCT-CNB) is a safe and accurate procedure for the evaluation of patients with pulmonary nodules. The purpose of our study was to evaluate the diagnostic performance, complication rates and effective radiation dose of CBCT-CNB with virtual guidance. MATERIALS AND METHODS: We retrospectively collected data regarding 375 CBCT-CNBs performed with virtual guidance (XperGuide-Philips Healthcare, Best, The Netherlands) from January 2010 to June 2015 on 355 patients (mean age, 68.1 years ± 11.8; age range, 31-88 years). Patients were divided into groups and compared based on the diagnostic failure and lesion size (15 mm cutoff). Diagnostic performance, complication rate and effective radiation dose were investigated. Variables influencing diagnostic performance and complications were assessed using Student's T test and Pearson's χ2 test. RESULTS: The sensitivity, specificity, positive and negative predictive value and accuracy for patients subjected to CNBs were 96.8%, 100%, 100%, 100% and 97.2%, respectively. Considering risk factors for pneumothorax, no significant differences were found regarding patient and lesion characteristics. Perilesional hemorrhage occurred more frequently in older patients (p = 0.046) and in smaller lesions (p = 0.001). Hemoptysis was significantly more frequent in patients with perilesional hemorrhage (p = 0.01). Mean effective radiation dose in CBCT-CNB was 7.12 ± 8.78 mSv. CONCLUSIONS: CBCT-CNB combined with virtual guidance is a reliable and accurate technique that allows exact localization of pulmonary lesions, effective preprocedural planning and real-time fluoroscopy altogether.


Assuntos
Tomografia Computadorizada de Feixe Cônico/métodos , Neoplasias Pulmonares/diagnóstico por imagem , Nódulos Pulmonares Múltiplos/diagnóstico por imagem , Doses de Radiação , Radiografia Intervencionista/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Biópsia por Agulha/métodos , Feminino , Humanos , Biópsia Guiada por Imagem/métodos , Pulmão/diagnóstico por imagem , Pulmão/patologia , Neoplasias Pulmonares/patologia , Masculino , Pessoa de Meia-Idade , Nódulos Pulmonares Múltiplos/patologia , Reprodutibilidade dos Testes , Estudos Retrospectivos , Fatores de Risco , Sensibilidade e Especificidade
13.
Br J Radiol ; 91(1092): 20170802, 2018 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-30074831

RESUMO

OBJECTIVE:: To evaluate image quality and radiation dose exposure of low-kV (100 kV) and low contrast medium (CM) volume CT angiography (CTA) in patients candidate to Transcatheter Aortic Valve Implantation (TAVI), in comparison with standard CTA protocol. METHODS:: 79 patients candidate for TAVI were prospectively enrolled in this study and examined with 256-MDCT. 42 patients were evaluated using study-group protocol (100 kV; whole-body retrospective ECG-gating; with 50 ml of CM; iterative reconstruction algorithm) while 37 patients underwent a standard CTA study (120 kV; ECG-gating for chest; 100 ml of CM; FBP reconstruction). Overall image quality was evaluated using a 4-point scale. Vascular enhancement (HU) was then assessed in each patient by manually drawing multiple ROIs in lumen of 7 segments of the whole aorta. The radiation dose exposure of both groups was calculated and all data were compared and statistically analyzed. RESULTS:: On low-kV protocol, higher mean attenuation values were achieved in all the measurements as compared to standard protocol. There were no significant differences in the image quality evaluation in both groups. Mean radiation dose value of study group was significantly lower than in control group (reduction of 20%). CONCLUSION:: Low kV and low CM volume CTA protocols allow TAVI planning to be carried out with high quality images and a significant reduction in the radiation dose as compared to the standard CTA protocol. ADVANCES IN KNOWLEDGE:: Low-kV CTA for pre-operative assessment of patients candidates for TAVI, permits to achieve a significant reduction of radiation dose exposure and contrast medium volume, reducing the risk of contrast induced nephropathy.


Assuntos
Algoritmos , Angiografia por Tomografia Computadorizada/métodos , Doses de Radiação , Substituição da Valva Aórtica Transcateter , Idoso , Idoso de 80 Anos ou mais , Aorta/diagnóstico por imagem , Estenose da Valva Aórtica/diagnóstico por imagem , Feminino , Humanos , Masculino
14.
World J Gastrointest Oncol ; 9(10): 423-430, 2017 Oct 15.
Artigo em Inglês | MEDLINE | ID: mdl-29085569

RESUMO

AIM: To compare radiation dose and image quality of low-dose computed tomography (CT) protocol combined with hybrid-iterative reconstruction algorithm with standard-dose CT examinations for follow-up of oncologic patients. METHODS: Fifty-one patients with known malignant diseases which underwent, during clinical follow-up, both standard-dose and low-dose whole-body CT scans were enrolled. Low-dose CT was performed on 256-row scanner, with 120 kV and automated mA modulation, and iterative reconstruction algorithm. Standard-dose CT was performed on 16-rows scanner, with 120 kV, 200-400 mAs (depending on patient weight). We evaluated density values and signal-to-noise ratio, along with image noise (SD), sharpness and diagnostic quality with 4-point scale. RESULTS: Density values in liver, spleen and aorta were higher in low-dose images (liver 112.55 HU vs 103.90 HU, P < 0.001), as SD values in liver and spleen (liver 16.81 vs 14.41). Volumetric-Computed-Tomographic-Dose-Index (CTDIvol) and Dose-Length-Product (DLP) were significantly lower in low-dose CT as compared to standard-dose (DLP 1025.6 mGy*cm vs 1429.2 mGy*cm, P < 0.001) with overall dose reduction of 28.9%. Qualitative analysis did not reveal significant differences in image noise and diagnostic quality. CONCLUSION: Automatic tube-current modulation combined with hybrid-iterative algorithm allows radiation dose reduction of 28.9% without loss of diagnostic quality, being useful in reducing dose exposure in oncologic patients.

15.
Radiol Med ; 122(12): 893-901, 2017 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-28849537

RESUMO

BACKGROUND: Effective radiation dose in coronary CT angiography (CTCA) for coronary artery bypass graft (CABG) evaluation is remarkably high because of long scan lengths. Prospective electrocardiographic gating with iterative reconstruction can reduce effective radiation dose. OBJECTIVES: To evaluate the diagnostic performance of low-kV CT angiography protocol with prospective ecg-gating technique and iterative reconstruction (IR) algorithm in follow-up of CABG patients compared with standard retrospective protocol. METHODS: Seventy-four non-obese patients with known coronary disease treated with artery bypass grafting were prospectively enrolled. All the patients underwent 256 MDCT (Brilliance iCT, Philips) CTCA using low-dose protocol (100 kV; 800 mAs; rotation time: 0.275 s) combined with prospective ECG-triggering acquisition and fourth-generation IR technique (iDose4; Philips); all the lengths of the bypass graft were included in the evaluation. A control group of 42 similar patients was evaluated with a standard retrospective ECG-gated CTCA (100 kV; 800 mAs).On both CT examinations, ROIs were placed to calculate standard deviation of pixel values and intra-vessel density. Diagnostic quality was also evaluated using a 4-point quality scale. RESULTS: Despite the statistically significant reduction of radiation dose evaluated with DLP (study group mean DLP: 274 mGy cm; control group mean DLP: 1224 mGy cm; P value < 0.001). No statistical differences were found between PGA group and RGH group regarding intra-vessel density absolute values and SNR. Qualitative analysis, evaluated by two radiologists in "double blind", did not reveal any significant difference in diagnostic quality of the two groups. CONCLUSIONS: The development of high-speed MDCT scans combined with modern IR allows an accurate evaluation of CABG with prospective ECG-gating protocols in a single breath hold, obtaining a significant reduction in radiation dose.


Assuntos
Técnicas de Imagem de Sincronização Cardíaca/métodos , Angiografia por Tomografia Computadorizada/métodos , Angiografia Coronária/métodos , Ponte de Artéria Coronária , Doença das Coronárias/diagnóstico por imagem , Doença das Coronárias/cirurgia , Proteção Radiológica/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Algoritmos , Eletrocardiografia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Doses de Radiação , Interpretação de Imagem Radiográfica Assistida por Computador
16.
Nutrition ; 32(11-12): 1231-7, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-27261062

RESUMO

OBJECTIVE: Complication rates after pancreatic resections remain high despite improvement in perioperative management. The effects of body composition and the relationship among different body compartments on surgical morbidity are not comprehensively investigated. The aim of this study was to assess whether the evaluation of different body compartments and their relationship was associated with the development of major postoperative complications after pancreatoduodenectomy (PD) for cancer. METHODS: We retrospectively analyzed 124 patients who underwent PD and had a staging computed tomography (CT) scan at our center. CT scan was used to measure abdominal skeletal muscle area and volume, as well as visceral fat area (VFA) and volume. The total abdominal muscle area (TAMA) was then normalized for height. The severity of complications was assessed. Univariate and multivariate analyses were performed to investigate correlations between the above variables and postoperative complications. The receiver operating characteristic curve methodology was used to investigate the predictive ability of each parameter. RESULTS: Major complications occurred in 42 patients (33.9%). The prevalence of sarcopenia was 24.2%. Regression analyses revealed no correlation between abdominal muscular and adipose tissue areas. Univariate analysis showed that the depletion of muscle area normalized for height was not per se predictive of complications (P = 0.318). Multivariate logistic regression showed that the VFA/TAMA was the only determinant of major complications (odds ratio, 3.20; 95% confidence interval, 1.35-7.60; P = 0.008). The model predictive performance was 0.735 (area under the curve) with a sensitivity of 64.3% and a specificity of 74.4%. CONCLUSION: Sarcopenic obesity is a strong predictor of major complications after PD for cancer.


Assuntos
Neoplasias Pancreáticas/cirurgia , Pancreaticoduodenectomia/efeitos adversos , Complicações Pós-Operatórias/etiologia , Idoso , Composição Corporal , Índice de Massa Corporal , Feminino , Humanos , Gordura Intra-Abdominal/diagnóstico por imagem , Gordura Intra-Abdominal/patologia , Masculino , Pessoa de Meia-Idade , Tomografia Computadorizada Multidetectores , Músculo Esquelético/diagnóstico por imagem , Músculo Esquelético/patologia , Neoplasias Pancreáticas/diagnóstico por imagem , Neoplasias Pancreáticas/patologia , Complicações Pós-Operatórias/diagnóstico por imagem , Complicações Pós-Operatórias/patologia , Estudos Retrospectivos , Fatores de Risco , Sarcopenia/diagnóstico por imagem , Sarcopenia/etiologia , Sarcopenia/patologia
17.
World J Gastroenterol ; 22(20): 4891-900, 2016 May 28.
Artigo em Inglês | MEDLINE | ID: mdl-27239115

RESUMO

AIM: To assess the diagnostic accuracy of multidetector-row computed tomography (MDCT) as compared with conventional magnetic resonance imaging (MRI), in identifying mesorectal fascia (MRF) invasion in rectal cancer patients. METHODS: Ninety-one patients with biopsy proven rectal adenocarcinoma referred for thoracic and abdominal CT staging were enrolled in this study. The contrast-enhanced MDCT scans were performed on a 256 row scanner (ICT, Philips) with the following acquisition parameters: tube voltage 120 KV, tube current 150-300 mAs. Imaging data were reviewed as axial and as multiplanar reconstructions (MPRs) images along the rectal tumor axis. MRI study, performed on 1.5 T with dedicated phased array multicoil, included multiplanar T2 and axial T1 sequences and diffusion weighted images (DWI). Axial and MPR CT images independently were compared to MRI and MRF involvement was determined. Diagnostic accuracy of both modalities was compared and statistically analyzed. RESULTS: According to MRI, the MRF was involved in 51 patients and not involved in 40 patients. DWI allowed to recognize the tumor as a focal mass with high signal intensity on high b-value images, compared with the signal of the normal adjacent rectal wall or with the lower tissue signal intensity background. The number of patients correctly staged by the native axial CT images was 71 out of 91 (41 with involved MRF; 30 with not involved MRF), while by using the MPR 80 patients were correctly staged (45 with involved MRF; 35 with not involved MRF). Local tumor staging suggested by MDCT agreed with those of MRI, obtaining for CT axial images sensitivity and specificity of 80.4% and 75%, positive predictive value (PPV) 80.4%, negative predictive value (NPV) 75% and accuracy 78%; while performing MPR the sensitivity and specificity increased to 88% and 87.5%, PPV was 90%, NPV 85.36% and accuracy 88%. MPR images showed higher diagnostic accuracy, in terms of MRF involvement, than native axial images, as compared to the reference magnetic resonance images. The difference in accuracy was statistically significant (P = 0.02). CONCLUSION: New generation CT scanner, using high resolution MPR images, represents a reliable diagnostic tool in assessment of loco-regional and whole body staging of advanced rectal cancer, especially in patients with MRI contraindications.


Assuntos
Adenocarcinoma/diagnóstico por imagem , Adenocarcinoma/patologia , Fáscia/diagnóstico por imagem , Fáscia/patologia , Tomografia Computadorizada Multidetectores , Estadiamento de Neoplasias/métodos , Neoplasias Retais/diagnóstico por imagem , Neoplasias Retais/patologia , Adulto , Idoso , Idoso de 80 Anos ou mais , Biópsia , Desenho de Equipamento , Feminino , Humanos , Imageamento por Ressonância Magnética , Masculino , Pessoa de Meia-Idade , Tomografia Computadorizada Multidetectores/instrumentação , Invasividade Neoplásica , Estadiamento de Neoplasias/instrumentação , Valor Preditivo dos Testes , Reprodutibilidade dos Testes , Estudos Retrospectivos , Tomógrafos Computadorizados
18.
J Comput Assist Tomogr ; 40(1): 152-9, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-26484957

RESUMO

OBJECTIVES: To evaluate intrareader and inter-reader agreement in CT perfusion (Perf) measurements in cirrhotic patients with hepatocellular carcinoma (HCC) lesions. METHODS: Sixteen patients with HCC (9 untreated, 5 recurrence/residual disease after transarterial chemoembolization, and 2 after radiofrequency ablation treatment) underwent standard CT examination and a Perf study; a quantitative map of arterial and portal Perf by means of a color scale was generated. With dedicated Perf software, the following parameters were calculated on untreated and treated HCC lesions and on cirrhotic parenchyma: hepatic Perf, tissue blood volume, hepatic perfusion index, arterial perfusion, and time to peak. Intraobserver and interobserver agreements were assessed for 2 readers with Bland-Altman plots, intraclass correlation coefficients (ICCs), coefficients of variation, and repeatability. RESULTS: In HCC lesions, agreement analysis demonstrated higher intra-agreement values in comparison with interagreement (range of ICC values, 0.26-0.59 between readers and 0.67-0.94 between readings). Lower interagreement was found for treated HCC lesions in comparison with untreated lesions (range of ICC values, respectively, 0.12-0.54 and 0.31-0.89). CONCLUSIONS: For all Perf parameters intra-agreement was higher than interagreement, even though a relatively wide range of 95% limits of agreement was found in both cases.


Assuntos
Carcinoma Hepatocelular/irrigação sanguínea , Carcinoma Hepatocelular/diagnóstico por imagem , Cirrose Hepática/diagnóstico por imagem , Neoplasias Hepáticas/irrigação sanguínea , Neoplasias Hepáticas/diagnóstico por imagem , Tomografia Computadorizada Multidetectores , Neovascularização Patológica/diagnóstico por imagem , Idoso , Idoso de 80 Anos ou mais , Carcinoma Hepatocelular/complicações , Feminino , Humanos , Fígado/irrigação sanguínea , Fígado/diagnóstico por imagem , Cirrose Hepática/complicações , Neoplasias Hepáticas/complicações , Masculino , Pessoa de Meia-Idade , Variações Dependentes do Observador , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
19.
Medicine (Baltimore) ; 94(31): e1152, 2015 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-26252274

RESUMO

The aim of this article is to assess whether measures of abdominal fat distribution, visceral density, and antropometric parameters obtained from computed tomography (CT) may predict postoperative pancreatic fistula (POPF) occurrence.We analyzed 117 patients who underwent pancreatoduodenectomy (PD) and had a preoperative CT scan as staging in our center. CT images were processed to obtain measures of total fat volume (TFV), visceral fat volume (VFV), density of spleen, and pancreas, and diameter of pancreatic duct. The predictive ability of each parameter was investigated by receiver-operating characteristic (ROC) curves methodology and assessing optimal cutoff thresholds. A stepwise selection method was used to determine the best predictive model.Clinically relevant (grades B and C) POPF occurred in 24 patients (20.5%). Areas under ROC-curves showed that none of the parameters was per se significantly predictive. The multivariate analysis revealed that a VFV >2334 cm, TFV >4408 cm, pancreas/spleen density ratio <0.707, and pancreatic duct diameter <5 mm were predictive of POPF. The risk of POPF progressively increased with the number of factors involved and age.It is possible to deduce objective information on the risk of POPF from a simple and routine preoperative radiologic workup.


Assuntos
Técnicas de Apoio para a Decisão , Fístula Pancreática/etiologia , Pancreaticoduodenectomia , Complicações Pós-Operatórias , Cuidados Pré-Operatórios/métodos , Tomografia Computadorizada por Raios X , Adulto , Idoso , Distribuição da Gordura Corporal , Feminino , Humanos , Modelos Logísticos , Masculino , Pessoa de Meia-Idade , Análise Multivariada , Avaliação de Resultados em Cuidados de Saúde , Pâncreas/diagnóstico por imagem , Fístula Pancreática/diagnóstico , Complicações Pós-Operatórias/diagnóstico , Curva ROC , Estudos Retrospectivos , Medição de Risco , Fatores de Risco
20.
Gastroenterol Res Pract ; 2015: 630273, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-26064093

RESUMO

Purpose. To assess the diagnostic accuracy of dynamic susceptibility contrast-enhanced magnetic resonance imaging (DSCE-MRI) in differentiation between benign and malignant liver lesions by assessment of tumoral perfusion parameters. Methods Materials. Seventy-three patients with known focal liver lesions, including 45 benign (16 FNH, 27 angiomas, and 2 abscesses) and 28 malignant ones (17 metastases, 9 HCCs, and 2 cholangiocarcinoma) underwent 1.5 T MRI upper abdominal study, with standard protocol that included dynamic contrast-enhanced sequences. On dedicated workstation, time-intensity curves were determined and the following perfusion parameters were calculated: relative arterial, venous and late enhancement (RAE, RVE, RLE), maximum enhancement (ME), relative enhancement (RE), and time to peak (TTP). Results. All diagnoses were established either by histopathology or imaging follow-up. Perfusion mean values calculated in benign lesions were RAE 33.8%, RVE 66.03%, RLE 80.63%, ME 776.00%, MRE 86.27%, and TTP 146.95 sec. Corresponding perfusion values calculated in malignant lesions were RAE 22.47%, RVE 40.54%, RLE 47.52%, ME 448.78%, MRE 49.85%, and TTP 183.79 sec. Statistical difference (p < 0.05) was achieved in all the perfusion parameters calculated, obtaining different cluster of perfusion kinetics between benign and malignant lesions. Conclusions. DSCE-MRI depicts kinetic differences in perfusion parameters among the different common liver lesions, related to tumour supply and microvascular characteristics.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA