Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
1.
Matern Child Health J ; 25(1): 136-150, 2021 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-33392930

RESUMO

INTRODUCTION: Though interest is growing for trials comparing planned delivery mode (vaginal delivery [VD]; cesarean section [CS]) in low-risk nulliparous women, appropriate study design is unclear. Our objective was to assess feasibility of three designs (preference trial [PCT], randomized controlled trial [RCT], partially randomized patient preference trial [PRPPT]) for a trial comparing planned delivery mode in low-risk women. METHODS: A cross-sectional survey of low-risk, nulliparous pregnant women (N = 416) and healthcare providers (N = 168) providing prenatal care and/or labor/delivery services was conducted in Argentina (2 public, 2 private hospitals). Proportion of pregnant women and providers willing to participate in each design and reasons for not participating were determined. RESULTS: Few women (< 15%) or professionals (33.3%) would participate in an RCT, though more would participate in PCTs (88% women; 65.9% professionals) or PRPPTs (44.4% public, 63.4% private sector women; 44.0% professionals). However, most women would choose vaginal delivery in the PCT and PRPPT (> 85%). Believing randomization unacceptable (RCT, PRPPT) and desiring choice of delivery mode (RCT) were women's reasons for not participating. For providers, commonly cited reasons for not participating included unacceptability of performing CS without medical indication, difficulty obtaining informed consent, discomfort enrolling patients (all designs), and violating women's right to choose (RCT). CONCLUSIONS FOR PRACTICE: Important limitations were found for each trial design evaluated. The necessity of stronger evidence regarding delivery mode in low-risk women suggests consideration of additional designs, such as a rigorously designed cohort study or an RCT within an obstetric population with equivocal CS indications.


Assuntos
Cesárea/estatística & dados numéricos , Parto Obstétrico/métodos , Procedimentos Cirúrgicos Eletivos , Pessoal de Saúde/psicologia , Preferência do Paciente , Adolescente , Adulto , Argentina , Estudos de Coortes , Estudos Transversais , Estudos de Viabilidade , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Gravidez , Medição de Risco , Adulto Jovem
2.
Reprod Health ; 15(1): 45, 2018 Mar 12.
Artigo em Inglês | MEDLINE | ID: mdl-29526165

RESUMO

BACKGROUND: A prolonged and complicated second stage of labour is associated with serious perinatal complications. The Odon device is an innovation intended to perform instrumental vaginal delivery presently under development. We present an evaluation of the feasibility and safety of delivery with early prototypes of this device from an early terminated clinical study. METHODS: Hospital-based, multi-phased, open-label, pilot clinical study with no control group in tertiary hospitals in Argentina and South Africa. Multiparous and nulliparous women, with uncomplicated singleton pregnancies, were enrolled during the third trimester of pregnancy. Delivery with Odon device was attempted under non-emergency conditions during the second stage of labour. The feasibility outcome was delivery with the Odon device defined as successful expulsion of the fetal head after one-time application of the device. RESULTS: Of the 49 women enrolled, the Odon device was inserted successfully in 46 (93%), and successful Odon device delivery as defined above was achieved in 35 (71%) women. Vaginal, first and second degree perineal tears occurred in 29 (59%) women. Four women had cervical tears. No third or fourth degree perineal tears were observed. All neonates were born alive and vigorous. No adverse maternal or infant outcomes were observed at 6-weeks follow-up for all dyads, and at 1 year for the first 30 dyads. CONCLUSIONS: Delivery using the Odon device is feasible. Observed genital tears could be due to the device or the process of delivery and assessment bias. Evaluating the effectiveness and safety of the further developed prototype of the BD Odon Device™ will require a randomized-controlled trial. TRIAL REGISTRATION: ANZCTR ACTRN12613000141741 Registered 06 February 2013. Retrospectively registered.


Assuntos
Extração Obstétrica/instrumentação , Adulto , Argentina , Colo do Útero/lesões , Extração Obstétrica/efeitos adversos , Extração Obstétrica/métodos , Feminino , Humanos , Períneo/lesões , Projetos Piloto , Gravidez , Resultado da Gravidez , Estudo de Prova de Conceito , África do Sul
3.
Reprod Health ; 10: 33, 2013 Jul 02.
Artigo em Inglês | MEDLINE | ID: mdl-23822879

RESUMO

BACKGROUND: Intrapartum complications are responsible for approximately half of all maternal deaths, and two million stillbirth and neonatal deaths per year. Prolonged second stage of labour is associated with potentially fatal maternal complications such as haemorrhage and infection and it is a major cause of stillbirth and newborn morbidity and mortality. Currently, the three main options for managing prolonged second stage of labour are forceps, vacuum extractor and caesarean section. All three clinical practices require relatively expensive equipment (e.g., a surgical theatre for caesarean section) and/or highly trained staff which are often not available in low resource settings. The specific aim of the proposed study is to test the safety and feasibility of a new device (Odón device) to effectively deliver the fetus during prolonged second stage of labour. The Odón device is a low-cost technological innovation to facilitate operative vaginal delivery and designed to minimize trauma to the mother and baby. These features combined make it a potentially revolutionary development in obstetrics, particularly for improving intrapartum care and reducing maternal and perinatal morbidity and mortality in low resource settings. METHODS/DESIGN: This will be a hospital-based, multicenter prospective phase 1 cohort study with no control group. Delivery with the Odón device will be attempted under normal labour and non-emergency conditions on all the women enrolled in the study. One-hundred and thirty pregnant women will be recruited in tertiary care facilities in Argentina. Safety will be assessed by examining maternal and infant outcomes until discharge. Feasibility will be evaluated by observing successful expulsion of the fetal head after one-time application of the device under standardized conditions (full cervical dilation, anterior presentation, +2 station, normal fetal heart rate). TRIAL REGISTRATION: Australian New Zealand Clinical Trials Registry (ANZCTR). Identifier: ACTRN12613000141741.


Assuntos
Segurança de Equipamentos , Extração Obstétrica/instrumentação , Adulto , Argentina , Estudos de Coortes , Extração Obstétrica/métodos , Estudos de Viabilidade , Feminino , Humanos , Trabalho de Parto , Gravidez , Instrumentos Cirúrgicos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA