Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 11 de 11
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
1.
Appl Opt ; 56(4): C11-C15, 2017 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-28158044

RESUMO

For the first time, direct detection of gravitational waves occurred in the Laser Interferometer Gravitational-wave Observatory (LIGO) interferometers. These advanced detectors require large fused silica mirrors with optical and mechanical properties and have never been reached until now. This paper details the main achievements of these ion beam sputtering coatings.

2.
Sci Rep ; 6: 36569, 2016 11 18.
Artigo em Inglês | MEDLINE | ID: mdl-27857146

RESUMO

We report and discuss high-flux generation of circularly polarized γ-rays by means of Compton scattering. The γ-ray beam results from the collision of an external-cavity-enhanced infrared laser beam and a low emittance relativistic electron beam. By operating a non-planar bow-tie high-finesse optical Fabry-Perot cavity coupled to a storage ring, we have recorded a flux of up to (3.5 ± 0.3) × 108 photons per second with a mean measured energy of 24 MeV. The γ-ray flux has been sustained for several hours. In particular, we were able to measure a record value of up to 400 γ-rays per collision in a full bandwidth. Moreover, the impact of Compton scattering on the electron beam dynamics could be observed resulting in a reduction of the electron beam lifetime correlated to the laser power stored in the Fabry-Perot cavity. We demonstrate that the electron beam lifetime provides an independent and consistent determination of the γ-ray flux. Furthermore, a reduction of the γ-ray flux due to intrabeam scattering has clearly been identified. These results, obtained on an accelerator test facility, warrant potential scaling and revealed both expected and yet unobserved effects. They set the baseline for further scaling of the future Compton sources under development around the world.

3.
Opt Lett ; 40(2): 174-7, 2015 Jan 15.
Artigo em Inglês | MEDLINE | ID: mdl-25679837

RESUMO

We present the optical optimization of an optomechanical device based on a suspended InP membrane patterned with a 2D near-wavelength grating (NWG) based on a 2D photonic-crystal geometry. We first identify by numerical simulation a set of geometrical parameters providing a reflectivity higher than 99.8% over a 50-nm span. We then study the limitations induced by the finite value of the optical waist and lateral size of the NWG pattern using different numerical approaches. The NWG grating, pierced in a suspended InP 265-nm thick membrane, is used to form a compact microcavity involving the suspended nanomembrane as an end mirror. The resulting cavity has a waist size smaller than 10 µm and a finesse in the 200 range. It is used to probe the Brownian motion of the mechanical modes of the nanomembrane.

4.
Appl Opt ; 53(5): 841-9, 2014 Feb 10.
Artigo em Inglês | MEDLINE | ID: mdl-24663262

RESUMO

Three-mode optoacoustic parametric amplifiers (OAPAs), in which a pair of photon modes are strongly coupled to an acoustic mode, provide a general platform for investigating self-cooling, parametric instability and very sensitive transducers. Their realization requires an optical cavity with tunable transverse modes and a high quality-factor mirror resonator. This paper presents the design of a table-top OAPA based on a near-self-imaging cavity design, using a silicon torsional microresonator. The design achieves a tuning coefficient for the optical mode spacing of 2.46 MHz/mm. This allows tuning of the mode spacing between amplification and self-cooling regimes of the OAPA device. Based on demonstrated resonator parameters (frequencies ∼400 kHz and quality-factors ∼7.5×10(5) we predict that the OAPA can achieve parametric instability with 1.6 µW of input power and mode cooling by a factor of 1.9×10(4) with 30 mW of input power.

5.
Appl Opt ; 52(34): 8376-80, 2013 Dec 01.
Artigo em Inglês | MEDLINE | ID: mdl-24513841

RESUMO

We report on the first demonstration, to the best of our knowledge, of the locking of a Fabry-Perot cavity with a finesse of 28,000 in the pulsed regime. The system is based on a stable picosecond oscillator, an ultrastable cavity with high-reflection mirrors, and an all-numerical feedback system that allows efficient and independent control of the repetition rate and the pulse to pulse carrier-to-envelop phase drift (CEP). We show that the carrier to envelop phase can have a dramatic effect even for pulses with hundreds of cycles. Moreover, we have succeeded in unambiguously measuring the CEP of a 2 ps pulse train. Finally, we discuss the potential of our findings to reach the MW average power level stored in an external cavity enhancement architecture.

6.
Opt Lett ; 36(8): 1407-9, 2011 Apr 15.
Artigo em Inglês | MEDLINE | ID: mdl-21499372

RESUMO

The new generation of advanced interferometer needs fused silica mirrors having better optical and mechanical properties. This Letter describes the way to reduce the ion beam sputtering coating absorption at 1064 nm and to improve the layer thickness uniformity in order to coat two large mirrors (diameter 35 cm) at the same time.

7.
Appl Opt ; 48(19): 3760-5, 2009 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-19571934

RESUMO

We discuss a method to control the coating thickness deposited onto large and strongly curved optics by ion beam sputtering. The technique uses an original design of the mask used to screen part of the sputtered materials. A first multielement mask is calculated from the measured two-dimensional coating thickness distribution. Then, by means of an iterative process, the final mask is designed. By using such a technique, it has been possible to deposit layers of tantalum pentoxide having a high thickness gradient onto a curved substrate 500 mm in diameter. Residual errors in the coating thickness profile are below 0.7%.

8.
G Ital Cardiol ; 16(4): 368-9, 1986 Apr.
Artigo em Italiano | MEDLINE | ID: mdl-3743939

RESUMO

In a 66-year-old patient a relationship between the development of gingival hyperplasia and nifedipine treatment was suggested. The hyperplasia was clinically and histologically similar to the gingival hyperplasia induced by diphenylhydantoin. The nifedipine-induced gingival hyperplasia may be probably caused by alterations in calcium metabolism. The withdrawal of the drug results in a complete remission of the disease.


Assuntos
Hiperplasia Gengival/induzido quimicamente , Nifedipino/efeitos adversos , Idoso , Humanos , Masculino
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA