Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 26
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
1.
Front Rehabil Sci ; 4: 1222174, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37841066

RESUMO

Spinal cord injury (SCI) can cause paralysis of trunk and hip musculature that negatively impacts seated balance and ability to lean away from an upright posture and interact fully with the environment. Constant levels of electrical stimulation of peripheral nerves can activate typically paralyzed muscles and aid in maintaining a single upright seated posture. However, in the absence of a feedback controller, such seated postures and leaning motions are inherently unstable and unable to respond to perturbations. Three individuals with motor complete SCI who had previously received a neuroprosthesis capable of activating the hip and trunk musculature volunteered for this study. Subject-specific muscle synergies were identified through system identification of the lumbar moments produced via neural stimulation. Synergy-based calculations determined the real-time stimulation parameters required to assume leaning postures. When combined with a proportional, integral, derivative (PID) feedback controller and an accelerometer to infer trunk orientation, all individuals were able to assume non-erect postures of 30-40° flexion and 15° lateral bending. Leaning postures increased forward reaching capabilities by 10.2, 46.7, and 16 cm respectively for each subject when compared with no stimulation. Additionally, the leaning controllers were able to resist perturbations of up to 90 N, and all subjects perceived the leaning postures as moderately to very stable. Implementation of leaning controllers for neuroprostheses have the potential of expanding workspaces, increasing independence, and facilitating activities of daily living for individuals with paralysis.

3.
J Neuroeng Rehabil ; 19(1): 85, 2022 08 09.
Artigo em Inglês | MEDLINE | ID: mdl-35945575

RESUMO

BACKGROUND: Stimulation-driven exercise is often limited by rapid fatigue of the activated muscles. Selective neural stimulation patterns that decrease activated fiber overlap and/or duty cycle improve cycling exercise duration and intensity. However, unequal outputs from independently activated fiber populations may cause large discrepancies in power production and crank angle velocity among pedal revolutions. Enforcing a constant cadence through feedback control of stimulus levels may address this issue and further improve endurance by targeting a submaximal but higher than steady-state exercise intensity. METHODS: Seven participants with paralysis cycled using standard cadence-controlled stimulation (S-Cont). Four of those participants also cycled with a low duty cycle (carousel) cadence-controlled stimulation scheme (C-Cont). S-Cont and C-Cont patterns were compared with conventional maximal stimulation (S-Max). Outcome measures include total work (W), end power (Pend), power fluctuation (PFI), charge accumulation (Q) and efficiency (η). Physiological measurements of muscle oxygenation (SmO2) and heart rate were also collected with select participants. RESULTS: At least one cadence-controlled stimulation pattern (S-Cont or C-Cont) improved Pend over S-Max in all participants and increased W in three participants. Both controlled patterns increased Q and η and reduced PFI compared with S-Max and prior open-loop studies. S-Cont stimulation also delayed declines in SmO2 and increased heart rate in one participant compared with S-Max. CONCLUSIONS: Cadence-controlled selective stimulation improves cycling endurance and increases efficiency over conventional stimulation by incorporating fiber groups only as needed to maintain a desired exercise intensity. Closed-loop carousel stimulation also successfully reduces power fluctuations relative to previous open-loop efforts, which will enable neuroprosthesis recipients to better take advantage of duty cycle reducing patterns.


Assuntos
Ciclismo , Paralisia , Ciclismo/fisiologia , Retroalimentação , Humanos , Músculo Esquelético/fisiologia
4.
J Med Eng Technol ; 46(5): 393-401, 2022 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-35674709

RESUMO

Vibration, a potent mechanical stimulus for activating muscle spindle primary afferents, may improve gait performance in persons with multiple sclerosis (MS), but has yet to be developed and deployed for multiple leg muscles with application during walking training. This study explored the development of a cyclic focal muscle vibration (FMV) system, and the deployment feasibility to correct MS walking swing phase deficits in order to determine whether this intervention warrants comprehensive study. The system was deployed during twelve, two-hour sessions of walking with cyclic FMV over six weeks. Participants served as their own control. Blood pressure, heart rate, walking speed, kinematics (peak hip, knee and ankle angles during swing), toe clearance, and step length were measured before and after deployment with blood pressure and heart rate monitored during deployment. During system deployment, there were no untoward sensations and physiological changes in blood pressure and heart rate, and volitional improvements were found in walking speed, improved swing phase kinematics, toe clearance and step length. This FMV training system was developed and deployed to improve joint flexion during walking in those with MS, and it demonstrated feasibility and benefits. Further study will determine the most effective vibration frequency and dose, carryover effects, and those most likely to benefit from this intervention.


Assuntos
Esclerose Múltipla , Vibração , Fenômenos Biomecânicos , Marcha/fisiologia , Humanos , Músculo Esquelético/fisiologia , Caminhada/fisiologia
5.
J Spinal Cord Med ; 45(2): 204-213, 2022 03.
Artigo em Inglês | MEDLINE | ID: mdl-32795162

RESUMO

Objective: Wheelchair safety is of great importance since falls from wheelchairs are prevalent and often have devastating consequences. We developed an automatic system to detect destabilizing events during wheelchair propulsion under real-world conditions and trigger neural stimulation to stiffen the trunk to maintain seated postures of users with paralysis.Design: Cross-over interventionSetting: Laboratory and community settingsParticipants: Three able-bodied subjects and three individuals with SCI with previously implanted neurostimulation systemsInterventions: An algorithm to detect wheelchair sudden stops was developed. This was used to randomly trigger trunk extensor stimulation during sudden stops eventsOutcome Measures: Algorithm success and false positive rates were determined. SCI users rated each condition on a seven-point Usability Rating Scale to indicate safety.Results: The system detected sudden stops with a success rate of over 93% in community settings. When used to trigger trunk neurostimulation to ensure stability, the implant recipients consistently reported feeling safer (P<.05 for 2/3 subjects) with the system while encountering sudden stops as indicated by a 1-3 point change in safety rating.Conclusion: These preliminary results suggest that this system could monitor wheelchair activity and only apply stabilizing neurostimulation when appropriate to maintain posture. Larger scale, unsupervised and longer-term trials at home and in the community are indicated. This system could be generalized and applied to individuals without an implanted stimulation by utilizing surface stimulation, or by actuating a mechanical restraint when necessary, thus allowing unrestricted trunk movements and only restraining the user when necessary to ensure safety.Trial Registration: NCT01474148.


Assuntos
Traumatismos da Medula Espinal , Cadeiras de Rodas , Humanos , Movimento , Postura/fisiologia , Postura Sentada
6.
J Neuroeng Rehabil ; 18(1): 117, 2021 07 23.
Artigo em Inglês | MEDLINE | ID: mdl-34301286

RESUMO

BACKGROUND: Exercise after paralysis can help prevent secondary health complications, but achieving adequate exercise volumes and intensities is difficult with loss of motor control. Existing electrical stimulation-driven cycling systems involve the paralyzed musculature but result in rapid force decline and muscle fatigue, limiting their effectiveness. This study explores the effects of selective stimulation patterns delivered through multi-contact nerve cuff electrodes on functional exercise output, with the goal of increasing work performed and power maintained within each bout of exercise. METHODS: Three people with spinal cord injury and implanted stimulation systems performed cycling trials using conventional (S-Max), low overlap (S-Low), low duty cycle (C-Max), and/or combined low overlap and low duty cycle (C-Low) stimulation patterns. Outcome measures include total work (W), end power (Pend), power fluctuation indices (PFI), charge accumulation (Q), and efficiency (η). Mann-Whitney tests were used for statistical comparisons of W and Pend between a selective pattern and S-Max. Welch's ANOVAs were used to evaluate differences in PFIs among all patterns tested within a participant (n ≥ 90 per stimulation condition). RESULTS: At least one selective pattern significantly (p < 0.05) increased W and Pend over S-Max in each participant. All selective patterns also reduced Q and increased η compared with S-Max for all participants. C-Max significantly (p < 0.01) increased PFI, indicating a decrease in ride smoothness with low duty cycle patterns. CONCLUSIONS: Selective stimulation patterns can increase work performed and power sustained by paralyzed muscles prior to fatigue with increased stimulation efficiency. While still effective, low duty cycle patterns can cause inconsistent power outputs each pedal stroke, but this can be managed by utilizing optimized stimulation levels. Increasing work and sustained power each exercise session has the potential to ultimately improve the physiological benefits of stimulation-driven exercise.


Assuntos
Terapia por Estimulação Elétrica , Traumatismos da Medula Espinal , Estimulação Elétrica , Humanos , Fadiga Muscular , Paralisia , Traumatismos da Medula Espinal/complicações
7.
Am J Phys Med Rehabil ; 100(10): 983-989, 2021 10 01.
Artigo em Inglês | MEDLINE | ID: mdl-33443856

RESUMO

OBJECTIVE: The aims of the study were to reliably determine the two main phases of manual wheelchair propulsion via a simple wearable sensor and to evaluate the effects of modulated trunk and hip stimulation on manual wheelchair propulsion during the challenging tasks of ramp assent and level sprint. DESIGN: An offline tool was created to identify common features between wrist acceleration signals for all subjects who corresponded to the transitions between the contact and recovery phases of manual wheelchair propulsion. For one individual, the acceleration rules and thresholds were implemented for real-time phase-change event detection and modulation of stimulation. RESULTS: When pushing with phase-dependent modulated stimulation, there was a significant (P < 0.05) increase in the primary speed variable (5%-6%) and the subject rated pushing as "moderately or very easy." In the offline analysis, the average phase-change event detection success rate was 79% at the end of contact and 71% at the end of recovery across the group. CONCLUSIONS: Signals from simple, wrist-mounted accelerometers can detect the phase transitions during manual wheelchair propulsion instead of elaborate and expensive, instrumented systems. Appropriately timing changes in muscle activation with the propulsion cycle can result in a significant increase in speed, and the system was consistently perceived to be significantly easier to use.


Assuntos
Pessoas com Deficiência/reabilitação , Músculo Esquelético/fisiologia , Tronco/fisiologia , Cadeiras de Rodas , Acelerometria , Fenômenos Biomecânicos , Feminino , Humanos , Masculino , Dispositivos Eletrônicos Vestíveis
8.
Med Eng Phys ; 86: 47-56, 2020 12.
Artigo em Inglês | MEDLINE | ID: mdl-33261733

RESUMO

Spinal cord injury (SCI) often results in loss of the ability to keep the trunk erect and stable while seated. Functional neuromuscular stimulation (FNS) can cause muscles paralyzed by SCI to contract and assist with trunk stability. We have extended the results of a previously reported threshold-based controller for restoring upright posture using FNS in the sagittal plane to more challenging displacements of the trunk in the coronal plane. The system was applied to five individuals with mid-thoracic or higher SCI, and in all cases the control system successfully restored upright sitting. The potential of the control system to maintain posture in forward-sideways (diagonal) directions was also tested in three of the subjects. In all cases, the controller successfully restored posture to erect. Clinically, these results imply that a simple, threshold based control scheme can restore upright sitting from forward, lateral or diagonal leaning without a chest strap; and that removal of barriers to upper extremity interaction with the surrounding environment could potentially allow objects to be more readily retrieved from around the wheelchair. Technical performance of the system was assessed in terms of three variables: response time, recovery time and percent maximum deviation from erect. Overall response and recovery times varied widely among subjects in the coronal plane (415±213 ms and 1381±883 ms, respectively) and in the diagonal planes (530±230 ms and 1800±820 ms, respectively). Average response time was significantly lower (p < 0.05) than the recovery time in all cases. The percent maximum deviation from erect was of the order of 40% or less for 9 out of 10 cases in the coronal plane and 5 out of 6 cases in diagonal directions.


Assuntos
Terapia por Estimulação Elétrica , Traumatismos da Medula Espinal , Humanos , Equilíbrio Postural , Postura , Traumatismos da Medula Espinal/terapia , Tronco
9.
Spinal Cord Ser Cases ; 6(1): 86, 2020 09 15.
Artigo em Inglês | MEDLINE | ID: mdl-32934207

RESUMO

STUDY DESIGN: Single-subject repeated measures study. OBJECTIVES: Neuromuscular electrical stimulation (NMES) can enhance walking for people with partial paralysis from incomplete spinal cord injury (iSCI). This single-subject study documents an individual's experience who both received an experimental implanted NMES system and underwent clinical bilateral hinged total knee arthroplasty (TKA). She walked in the community with knee pain prior to either intervention. Walking performance improved with an implanted NMES system. Knee pain and instability continued to worsen over time and eventually required TKA. This study evaluates the effects of these interventions. SETTING: Louis Stokes Cleveland Veterans Affairs Medical Center, Cleveland OH, USA. METHODS: The differential and combined effects of NMES and hinged knee replacement were assessed in terms of walking speed, toe clearance, knee angle, and participant perceptions with and without stimulation assistance both before and after TKA. RESULTS: The combined approach both reduced pain and restored walking ability to levels achieved prior to developing significant knee pain that prevented walking without NMES. There was an interaction effect between NMES and TKA on walking speed. Toe clearance consistently improved with stimulation assistance and TKA prevented significant knee hyperextension. The greatest impact was on endurance. Knee replacement re-enabled long distance walking with the addition of stimulation again more than doubling her maximum walking distance from 214 to 513 m. CONCLUSIONS: These data support further research of combined implantable interventions that may benefit people with iSCI. Furthermore, joint laxity and pain may not necessarily be contraindications to NMES if addressed with conventional clinical treatments.


Assuntos
Artroplastia do Joelho , Articulação do Joelho/fisiopatologia , Traumatismos da Medula Espinal/reabilitação , Caminhada/fisiologia , Estimulação Elétrica/métodos , Terapia por Estimulação Elétrica/métodos , Humanos , Próteses e Implantes
10.
Am J Phys Med Rehabil ; 99(12): e138-e141, 2020 12.
Artigo em Inglês | MEDLINE | ID: mdl-32149817

RESUMO

This case study evaluated the effect of implanted multijoint neuromuscular electrical stimulation gait assistance on oxygen consumption relative to walking without neuromuscular electrical stimulation after stroke. The participant walked slowly with an asymmetric gait pattern after stroke. He completed repeated 6-min walk tests at a self-selected walking speed with and without hip, knee, and ankle stimulation assistance. His walking speed with neuromuscular electrical stimulation more than doubled from 0.28 ± 0.01 m/sec to 0.58 ± 0.04 m/sec, whereas average step length and cadence increased by 0.12 m and 24 steps/min, respectively. As a result, energy cost of walking with neuromuscular electrical stimulation decreased by 0.19 ml O2/kg per meter as compared with walking without stimulation while oxygen consumption increased by 1.1 metabolic equivalent of tasks (3.9 ml O2/kg per minute). These metabolic demands are similar to those reported for stroke survivors capable of walking at equivalent speeds without stimulation, suggesting the increase in oxygen consumption and decreased energy cost result from improved efficiency of faster walking facilitated by neuromuscular electrical stimulation. Although the effect of neuromuscular electrical stimulation on gait economy has implications for community walking within the user's metabolic reserves, this case study's results should be interpreted with caution and the hypothesis that multijoint neuromuscular electrical stimulation improves metabolic efficiency should be tested in a wide population of stroke survivors with varied deficits.


Assuntos
Terapia por Estimulação Elétrica , Consumo de Oxigênio/fisiologia , Reabilitação do Acidente Vascular Cerebral , Acidente Vascular Cerebral/metabolismo , Acidente Vascular Cerebral/fisiopatologia , Caminhada/fisiologia , Idoso , Humanos , Articulações , Masculino , Acidente Vascular Cerebral/complicações
11.
J Neuroeng Rehabil ; 15(1): 17, 2018 03 12.
Artigo em Inglês | MEDLINE | ID: mdl-29530053

RESUMO

BACKGROUND: The leading cause of injury for manual wheelchair users are tips and falls caused by unexpected destabilizing events encountered during everyday activities. The purpose of this study was to determine the feasibility of automatically restoring seated stability to manual wheelchair users with spinal cord injury (SCI) via a threshold-based system to activate the hip and trunk muscles with electrical stimulation during potentially destabilizing events. METHODS: We detected and classified potentially destabilizing sudden stops and turns with a wheelchair-mounted wireless inertial measurement unit (IMU), and then applied neural stimulation to activate the appropriate muscles to resist trunk movement and restore seated stability. After modeling and preliminary testing to determine the appropriate inertial signatures to discriminate between events and reliably trigger stimulation, the system was implemented and evaluated in real-time on manual wheelchair users with SCI. Three participants completed simulated collision events and four participants completed simulated rapid turns. Data were analyzed as a series of individual case studies with subjects acting as their own controls with and without the system active. RESULTS: The controller achieved 93% accuracy in detecting collisions and right turns, and 100% accuracy in left turn detection. Two of the three subjects who participated in collision testing with stimulation experienced significantly decreased maximum anterior-posterior trunk angles (p < 0.05). Similar results were obtained with implanted and surface stimulation systems. CONCLUSIONS: This study demonstrates the feasibility of a neural stimulation control system based on simple inertial measurements to improve trunk stability and overall safety of people with spinal cord injuries during manual wheelchair propulsion. Further studies are required to determine clinical utility in real world situations and generalizability to the broader SCI or other population of manual or powered wheelchair users. TRIAL REGISTRATION: ClinicalTrials.gov Identifier NCT01474148 . Registered 11/08/2011 retrospectively registered.


Assuntos
Terapia por Estimulação Elétrica/métodos , Equilíbrio Postural/fisiologia , Postura Sentada , Traumatismos da Medula Espinal , Cadeiras de Rodas , Acidentes por Quedas/prevenção & controle , Adulto , Fenômenos Biomecânicos , Pessoas com Deficiência , Desenho de Equipamento/métodos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Cadeiras de Rodas/efeitos adversos
12.
Arch Phys Med Rehabil ; 99(2): 289-298, 2018 02.
Artigo em Inglês | MEDLINE | ID: mdl-28899825

RESUMO

OBJECTIVE: To quantify the long-term (>2y) effects of lower extremity (LE) neuroprostheses (NPs) for standing, transfers, stepping, and seated stability after spinal cord injury. DESIGN: Single-subject design case series with participants acting as their own concurrent controls, including retrospective data review. SETTING: Hospital-based clinical biomechanics laboratory with experienced (>20y in the field) research biomedical engineers, a physical therapist, and medical monitoring review. PARTICIPANTS: Long-term (6.2±2.7y) at-home users (N=22; 19 men, 3 women) of implanted NPs for trunk and LE function with chronic (14.4±7.1y) spinal cord injury resulting in full or partial paralysis. INTERVENTIONS: Technical and clinical performance measurements, along with user satisfaction surveys. MAIN OUTCOME MEASURES: Knee extension moment, maximum standing time, body weight supported by lower extremities, 3 functional standing tasks, 2 satisfaction surveys, NP usage, and stability of implanted components. RESULTS: Stimulated knee extension strength and functional capabilities were maintained, with 94% of implant recipients reporting being very or moderately satisfied with their system. More than half (60%) of the participants were still using their implanted NPs for exercise and function for >10min/d on nearly half or more of the days monitored; however, maximum standing times and percentage body weight through LEs decreased slightly over the follow-up interval. Stimulus thresholds were uniformly stable. Six-year survival rates for the first-generation implanted pulse generator (IPG) and epimysial electrodes were close to 90%, whereas those for the second-generation IPG along with the intramuscular and nerve cuff electrodes were >98%. CONCLUSIONS: Objective and subjective measures of the technical and clinical performances of implanted LE NPs generally remained consistent for 22 participants after an average of 6 years of unsupervised use at home. These findings suggest that implanted LE NPs can provide lasting benefits that recipients value.


Assuntos
Extremidade Inferior/fisiopatologia , Próteses Neurais , Paraplegia/fisiopatologia , Paraplegia/reabilitação , Satisfação do Paciente , Postura/fisiologia , Traumatismos da Medula Espinal/fisiopatologia , Atividades Cotidianas , Adulto , Fenômenos Biomecânicos , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Inquéritos e Questionários , Resultado do Tratamento
13.
J Spinal Cord Med ; 41(2): 165-173, 2018 03.
Artigo em Inglês | MEDLINE | ID: mdl-28155591

RESUMO

OBJECTIVE: Test the effect of a multi-joint control with implanted electrical stimulation on walking after spinal cord injury (SCI). DESIGN: Single subject research design with repeated measures. SETTING: Hospital-based biomechanics laboratory and user assessment of community use. PARTICIPANTS: Female with C6 AIS C SCI 30 years post injury. INTERVENTIONS: Lower extremity muscle activation with an implanted pulse generator and gait training. OUTCOME MEASURES: Walking speed, maximum distance, oxygen consumption, upper extremity (UE) forces, kinematics and self-assessment of technology. RESULTS: Short distance walking speed at one-year follow up with or without stimulation was not significantly different from baseline. However, average walking speed was significantly faster (0.22 m/s) with stimulation over longer distances than volitional walking (0.12 m/s). In addition, there was a 413% increase in walking distance from 95 m volitionally to 488 m with stimulation while oxygen consumption and maximum upper extremity forces decreased by 22 and 16%, respectively. Stimulation also produced significant (P ≤ 0.001) improvements in peak hip and knee flexion, ankle angle at foot off and at mid-swing. CONCLUSION: An implanted neuroprosthesis enabled a subject with incomplete SCI to walk longer distances with improved hip and knee flexion and ankle dorsiflexion resulting in decreased oxygen consumption and UE support. Further research is required to determine the robustness, generalizability and functional implications of implanted neuroprostheses for community ambulation after incomplete SCI.


Assuntos
Terapia por Estimulação Elétrica/instrumentação , Próteses e Implantes , Traumatismos da Medula Espinal/reabilitação , Caminhada/fisiologia , Feminino , Marcha , Articulação do Quadril , Humanos , Articulação do Joelho , Pessoa de Meia-Idade , Amplitude de Movimento Articular
14.
J Neuroeng Rehabil ; 14(1): 118, 2017 Nov 17.
Artigo em Inglês | MEDLINE | ID: mdl-29149885

RESUMO

The reduction in physical activity following a spinal cord injury often leads to a decline in mental and physical health. Developing an exercise program that is effective and enjoyable is paramount for this population. Although functional electrical stimulation (FES) stationary cycling has been utilized in rehabilitation settings, implementing an overground cycling program for those with spinal cord injuries has greater technical challenges. Recently our laboratory team focused on training five individuals with compete spinal cord injuries utilizing an implanted pulse generator for an overground FES bike race in CYBATHLON 2016 held in Zurich, Switzerland. The advancements in muscle strength and endurance and ultimately cycling power our pilots made during this training period not only helped propel our competing pilot to win gold at the CYBATHLON 2016, but allowed our pilots to ride their bikes outside within their communities. Such a positive outcome has encouraged us to put effort into developing more widespread use of FES overground cycling as a rehabilitative tool for those with spinal cord injuries. This commentary will describe our approach to the CYBATHLON 2016 including technological advancements, bike design and the training program.


Assuntos
Ciclismo , Terapia por Estimulação Elétrica/métodos , Terapia por Exercício/métodos , Traumatismos da Medula Espinal/reabilitação , Feminino , Humanos , Masculino , Pessoa de Meia-Idade
15.
J Neuroeng Rehabil ; 14(1): 48, 2017 05 30.
Artigo em Inglês | MEDLINE | ID: mdl-28558835

RESUMO

BACKGROUND: Functional neuromuscular stimulation, lower limb orthosis, powered lower limb exoskeleton, and hybrid neuroprosthesis (HNP) technologies can restore stepping in individuals with paraplegia due to spinal cord injury (SCI). However, a self-contained muscle-driven controllable exoskeleton approach based on an implanted neural stimulator to restore walking has not been previously demonstrated, which could potentially result in system use outside the laboratory and viable for long term use or clinical testing. In this work, we designed and evaluated an untethered muscle-driven controllable exoskeleton to restore stepping in three individuals with paralysis from SCI. METHODS: The self-contained HNP combined neural stimulation to activate the paralyzed muscles and generate joint torques for limb movements with a controllable lower limb exoskeleton to stabilize and support the user. An onboard controller processed exoskeleton sensor signals, determined appropriate exoskeletal constraints and stimulation commands for a finite state machine (FSM), and transmitted data over Bluetooth to an off-board computer for real-time monitoring and data recording. The FSM coordinated stimulation and exoskeletal constraints to enable functions, selected with a wireless finger switch user interface, for standing up, standing, stepping, or sitting down. In the stepping function, the FSM used a sensor-based gait event detector to determine transitions between gait phases of double stance, early swing, late swing, and weight acceptance. RESULTS: The HNP restored stepping in three individuals with motor complete paralysis due to SCI. The controller appropriately coordinated stimulation and exoskeletal constraints using the sensor-based FSM for subjects with different stimulation systems. The average range of motion at hip and knee joints during walking were 8.5°-20.8° and 14.0°-43.6°, respectively. Walking speeds varied from 0.03 to 0.06 m/s, and cadences from 10 to 20 steps/min. CONCLUSIONS: A self-contained muscle-driven exoskeleton was a feasible intervention to restore stepping in individuals with paraplegia due to SCI. The untethered hybrid system was capable of adjusting to different individuals' needs to appropriately coordinate exoskeletal constraints with muscle activation using a sensor-driven FSM for stepping. Further improvements for out-of-the-laboratory use should include implantation of plantar flexor muscles to improve walking speed and power assist as needed at the hips and knees to maintain walking as muscles fatigue.


Assuntos
Terapia por Estimulação Elétrica/instrumentação , Exoesqueleto Energizado , Paraplegia/reabilitação , Traumatismos da Medula Espinal/reabilitação , Adulto , Feminino , Humanos , Extremidade Inferior/fisiopatologia , Masculino , Paraplegia/etiologia , Traumatismos da Medula Espinal/complicações , Caminhada/fisiologia
16.
Eur J Transl Myol ; 27(4): 7087, 2017 Dec 05.
Artigo em Inglês | MEDLINE | ID: mdl-29299221

RESUMO

Recently our laboratory team focused on training five individuals with complete spinal cord injuries for an overground FES bike race in the 2016 Cybathlon held in Zurich Switzerland. A unique advantage team Cleveland had over other teams was the use of implanted pulse generators that provide more selective activation of muscles compared to standard surface stimulation. The advancements in muscle strength and endurance and ultimately cycling power our pilots made during this training period helped propel our competing pilot to win gold at the Cybathlon and allowed our pilots to ride their bikes outside within their communities. Such positive outcomes has encouraged us to further explore more widespread use of FES overground cycling as a rehabilitative tool for those with spinal cord injuries. This review will describes our approach to this race including information on the pilots, stimulation strategy, bike details and training program.

17.
Am J Phys Med Rehabil ; 95(12): 880-888, 2016 12.
Artigo em Inglês | MEDLINE | ID: mdl-27231842

RESUMO

OBJECTIVE: The objective of this work was to quantify the effects of a fully implanted pulse generator to activate or augment actions of hip, knee, and ankle muscles after stroke. DESIGN: The subject was a 64-year-old man with left hemiparesis resulting from hemorrhagic stroke 21 months before participation. He received an 8-channel implanted pulse generator and intramuscular stimulating electrodes targeting unilateral hip, knee, and ankle muscles on the paretic side. After implantation, a stimulation pattern was customized to assist with hip, knee, and ankle movement during gait.The subject served as his own concurrent and longitudinal control with and without stimulation. Outcome measures included 10-m walk and 6-minute timed walk to assess gait speed, maximum walk time, and distance to measure endurance, and quantitative motion analysis to evaluate spatial-temporal characteristics. Assessments were repeated under 3 conditions: (1) volitional walking at baseline, (2) volitional walking after training, and (3) walking with stimulation after training. RESULTS: Volitional gait speed improved with training from 0.29 m/s to 0.35 m/s and further increased to 0.72 m/s with stimulation. Most spatial-temporal characteristics improved and represented more symmetrical and dynamic gait. CONCLUSIONS: These data suggest that a multijoint approach to implanted neuroprostheses can provide clinically relevant improvements in gait after stroke. TO CLAIM CME CREDITS: Complete the self-assessment activity and evaluation online at http://www.physiatry.org/JournalCME CME OBJECTIVES:: Upon completion of this article, the reader should be able to do the following: (1) Describe the rationale for evaluating a multijoint implanted neuroprosthesis to improvewalkingafter stroke; (2)Understand the study design and conclusions that can be inferred as a result of the design; and (3) Discuss the statistical significance and clinical relevance of changes between (a) volitional walking at baseline, (b) volitional walking after training, and (c) walking with stimulation after training. LEVEL: Advanced ACCREDITATION:: The Association of Academic Physiatrists is accredited by the Accreditation Council for Continuing Medical Education to provide continuing medical education for physicians. The Association of Academic Physiatrists designates this activity for a maximum of 1.5 AMA PRA Category 1 Credit(s)™. Physicians should only claim credit commensurate with the extent of their participation in the activity.


Assuntos
Próteses Neurais , Paresia/reabilitação , Reabilitação do Acidente Vascular Cerebral , Acidente Vascular Cerebral/fisiopatologia , Caminhada/fisiologia , Tornozelo , Quadril , Humanos , Joelho , Masculino , Pessoa de Meia-Idade , Paresia/etiologia , Paresia/fisiopatologia , Amplitude de Movimento Articular , Acidente Vascular Cerebral/complicações
18.
J Neuroeng Rehabil ; 13: 27, 2016 Mar 15.
Artigo em Inglês | MEDLINE | ID: mdl-26979386

RESUMO

BACKGROUND: Users of neuroprostheses employing electrical stimulation (ES) generally complete the stand-to-sit (STS) maneuver with high knee angular velocities, increased upper limb support forces, and high peak impact forces at initial contact with the chair. Controlling the knee during STS descent is challenging in individuals with spinal cord injury (SCI) due to the decreasing joint moment available with increased knee angle in response to ES. METHODS: The goal of this study was to investigate the effects of incorporating either (1) a coupling mechanism that coordinates hip and knee flexion or (2) a mechanism that damps knee motion to keep the knee angular velocity constant during the STS transition. The coupling and damping were achieved by hydraulic orthotic mechanisms. Two subjects with SCI were enrolled and each served as their own controls when characterizing the performance of each mechanism during STS as compared to stimulation alone. Outcome measures such as hip-knee angle, knee angular velocity, upper limb support force, and impact force were analyzed to determine the effectiveness of the two mechanisms in providing controlled STS. RESULTS: The coordination between the hip and knee joints improved with each orthotic mechanism. The damping and hip-knee coupling mechanisms caused the hip and knee joint ratios of 1:1.1 and 1:0.99, respectively, which approached the 1:1 coordination ratio observed in nondisabled individuals during STS maneuver. The knee damping mechanism provided lower (p < 0.001) and a more constant knee angular velocity than the hip-knee coupling mechanism over the knee range of motion. Both the coupling and damping mechanisms were similarly effective at reducing upper limb support forces by 70 % (p < 0.001) and impact force by half (p ≤ 0.001) as compared to sitting down with stimulation alone. CONCLUSIONS: Orthoses imposing simple kinematic constraints, such as 1:1 hip-knee coupling or knee damping, can normalize upper limb support forces, peak knee angular velocity, and peak impact force during the STS maneuvers.


Assuntos
Aparelhos Ortopédicos , Postura/fisiologia , Desempenho Psicomotor/fisiologia , Traumatismos da Medula Espinal/reabilitação , Adulto , Fenômenos Biomecânicos , Feminino , Articulação do Quadril/fisiologia , Humanos , Articulação do Joelho/fisiologia , Masculino , Amplitude de Movimento Articular
19.
Annu Int Conf IEEE Eng Med Biol Soc ; 2016: 6369-6372, 2016 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-28269706

RESUMO

An untethered version of a stimulation-driven exoskeleton was evaluated for its ability to restore walking after paralysis from spinal cord injury. The hybrid neuroprosthesis (HNP) combined a passive variable-constraint exoskeleton for stability and support with functional neuromuscular stimulation (FNS) to contract the paralyzed muscles to drive limb movement. This self-contained HNP was operated by an onboard controller that sampled sensor signals, generated appropriate commands to both the exoskeletal constraints and integrated stimulator, and transmitted data wirelessly via Bluetooth to an off-board computer for real-time monitoring and recording for offline analysis. The subject selected the desired function (i.e. standing up, stepping, or sitting down) by means of a wireless finger switch that communicated with the onboard controller. Within the stepping function, a gait event detector supervisory controller transitioned between the different phases of gait such as double stance, swing, and weight acceptance based on signals from sensors incorporated into the exoskeleton. The different states of the control system governed the locking and unlocking of the exoskeletal hip and knee joints as well as the stimulation patterns activating hip and knee flexor or extensor muscles at the appropriate times and intensities to enable stepping. This study was one of our first successful implementations of the self-contained "muscle-first" HNP and successfully restored gait to an individual with motor complete mid-thoracic paraplegia.


Assuntos
Paraplegia/fisiopatologia , Caminhada , Estimulação Elétrica , Eletrodos Implantados , Marcha , Articulação do Quadril/fisiopatologia , Humanos , Articulação do Joelho/fisiopatologia , Masculino , Pessoa de Meia-Idade , Músculo Esquelético/fisiopatologia , Paraplegia/complicações , Traumatismos da Medula Espinal/complicações
20.
J Rehabil Res Dev ; 53(6): 919-932, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-28475203

RESUMO

Electrical activation of paralyzed musculature can generate or augment joint movements required for walking after central nervous system trauma. Proper timing of stimulation relative to residual volitional control is critical to usefully affecting ambulation. This study evaluates three-dimensional accelerometers and customized algorithms to detect the intent to step from voluntary movements to trigger stimulation during walking in individuals with significantly different etiologies, mobility limitations, manual dexterities, and walking aids. Three individuals with poststroke hemiplegia or partial spinal cord injury exhibiting varying gait deficits were implanted with multichannel pulse generators to provide joint motions at the hip, knee, and ankle. An accelerometer integrated into the external control unit was used to detect heel strike or walker movement, and wireless accelerometers were used to detect crutch strike. Algorithms were developed for each sensor location to detect intent to step to progress through individualized stimulation patterns. Testing these algorithms produced detection accuracies of at least 90% on both level ground and uneven terrain. All participants use their accelerometer-triggered implanted gait systems in the community; the validation/system testing was completed in the hospital. The results demonstrated that safe, reliable, and convenient accelerometer-based step initiation can be achieved regardless of specific gait deficits, manual dexterities, and walking aids.


Assuntos
Acelerometria , Marcha , Próteses e Implantes , Traumatismos da Medula Espinal/terapia , Algoritmos , Humanos , Caminhada
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA