Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 11 de 11
Filtrar
Mais filtros








Intervalo de ano de publicação
1.
Transfusion ; 64(3): 501-509, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38258881

RESUMO

BACKGROUND: Transfusion-transmitted malaria (TTM) is a public health problem in endemic and nonendemic areas. The Brazilian Ministry of Health (MH) requested the development of a nucleic acid amplification test (NAT) for the detection of Plasmodium spp. in public blood centers to increase blood safety. STUDY DESIGN AND METHODS: The new Brazilian NAT kit named NAT PLUS HIV/HBV/HCV/Malaria Bio-Manguinhos was first implemented in HEMORIO, a public blood center in the city of Rio de Janeiro. Since October 1, 2022, this blood center has been testing all its blood donations for malaria in a pool of six plasma samples to detect Plasmodium spp. by real-time polymerase chain reaction (PCR). RESULTS: Since the implementation of the NAT PLUS platform until February 2023, HEMORIO has successfully received and tested 200,277 donations. The platform detected two asymptomatic donors in the city of Rio de Janeiro, which is a nonendemic region for malaria. Our analyses suggested a malaria from the Amazon region caused by Plasmodium vivax, in the first case, while an autochthonous transmission case by Plasmodium malariae was identified in the rural area of Rio de Janeiro state. DISCUSSION: The NAT PLUS platform detects Plasmodium spp. in plasma samples with sensitivity capable of detecting subpatent infections. This is the first time worldwide that a group developed and implemented molecular diagnosis for Plasmodium spp. to be used by public blood centers to avoid TTM.


Assuntos
Infecções por HIV , Hepatite C , Malária , Humanos , Vírus da Hepatite B , Doadores de Sangue , Brasil/epidemiologia , Malária/diagnóstico , Malária/epidemiologia , Plasmodium malariae , Infecções por HIV/diagnóstico , Infecções por HIV/epidemiologia
2.
Mem Inst Oswaldo Cruz ; 118: e220202, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-36946838

RESUMO

BACKGROUND: The prevalence of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) variants of concern (VOCs) has changed unevenly over time around the world. Although whole genome sequencing is the gold standard for virus characterisation, the discovery of alpha VOC causing spike gene target failure (SGTF) result, when tested using an reverse transcription real-time polymerase chain reaction (RT-qPCR) assay, has provided a simple tool for tracking the frequencies of variants. OBJECTIVES: The aim of this study was to investigate if a multiplex RT-qPCR assay (BioM 4Plex VOC) could be used to detect SARS-CoV-2 and to perform a VOC screening test in a single reaction tube. Here, we present the multicentre study evaluating this assay. METHODS: Twelve laboratories have participated in the multicentre study. The BioM 4Plex VOC was distributed to them with detailed instructions of how to perform the test. They were asked to test the BioM 4Plex VOC in parallel with their routine Commercial SARS-CoV-2 diagnostic assay. Additionally, they were requested to select SARS-CoV-2-positive samples with genome sequenced and lineage definition according to PANGO lineage classification. FINDINGS: The BioM 4Plex VOC and commercial RT-PCR assay are equally effective in detecting SARS-CoV-2. Results revealed a specificity of 96.5-100% [95% confidence interval (CI)], a sensitivity of 99.8-100% (95% CI), and an accuracy of 99.8-100% (95% CI). A 99% concordance rate was found between results from the BioM 4Plex VOC and that from available genome sequencing data. MAIN CONCLUSIONS: The BioM 4Plex VOC provides an effective solution to detect SARS-CoV-2 infections and screening for VOCs in a single reaction. It is a straightforward method to help us monitor the frequency and distribution of VOCs and develop strategies to better cope with the pandemics.


Assuntos
COVID-19 , SARS-CoV-2 , Humanos , SARS-CoV-2/genética , COVID-19/diagnóstico , Teste para COVID-19 , Bioensaio , Mapeamento Cromossômico
3.
Mem. Inst. Oswaldo Cruz ; 118: e220202, 2023. tab, graf
Artigo em Inglês | LILACS-Express | LILACS | ID: biblio-1422150

RESUMO

BACKGROUND The prevalence of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) variants of concern (VOCs) has changed unevenly over time around the world. Although whole genome sequencing is the gold standard for virus characterisation, the discovery of alpha VOC causing spike gene target failure (SGTF) result, when tested using an reverse transcription real-time polymerase chain reaction (RT-qPCR) assay, has provided a simple tool for tracking the frequencies of variants. OBJECTIVES The aim of this study was to investigate if a multiplex RT-qPCR assay (BioM 4Plex VOC) could be used to detect SARS-CoV-2 and to perform a VOC screening test in a single reaction tube. Here, we present the multicentre study evaluating this assay. METHODS Twelve laboratories have participated in the multicentre study. The BioM 4Plex VOC was distributed to them with detailed instructions of how to perform the test. They were asked to test the BioM 4Plex VOC in parallel with their routine Commercial SARS-CoV-2 diagnostic assay. Additionally, they were requested to select SARS-CoV-2-positive samples with genome sequenced and lineage definition according to PANGO lineage classification. FINDINGS The BioM 4Plex VOC and commercial RT-PCR assay are equally effective in detecting SARS-CoV-2. Results revealed a specificity of 96.5-100% [95% confidence interval (CI)], a sensitivity of 99.8-100% (95% CI), and an accuracy of 99.8-100% (95% CI). A 99% concordance rate was found between results from the BioM 4Plex VOC and that from available genome sequencing data. MAIN CONCLUSIONS The BioM 4Plex VOC provides an effective solution to detect SARS-CoV-2 infections and screening for VOCs in a single reaction. It is a straightforward method to help us monitor the frequency and distribution of VOCs and develop strategies to better cope with the pandemics.

4.
Mem. Inst. Oswaldo Cruz ; 118: e220202, 2023. tab, graf
Artigo em Inglês | LILACS-Express | LILACS | ID: biblio-1430842

RESUMO

BACKGROUND The prevalence of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) variants of concern (VOCs) has changed unevenly over time around the world. Although whole genome sequencing is the gold standard for virus characterisation, the discovery of alpha VOC causing spike gene target failure (SGTF) result, when tested using an reverse transcription real-time polymerase chain reaction (RT-qPCR) assay, has provided a simple tool for tracking the frequencies of variants. OBJECTIVES The aim of this study was to investigate if a multiplex RT-qPCR assay (BioM 4Plex VOC) could be used to detect SARS-CoV-2 and to perform a VOC screening test in a single reaction tube. Here, we present the multicentre study evaluating this assay. METHODS Twelve laboratories have participated in the multicentre study. The BioM 4Plex VOC was distributed to them with detailed instructions of how to perform the test. They were asked to test the BioM 4Plex VOC in parallel with their routine Commercial SARS-CoV-2 diagnostic assay. Additionally, they were requested to select SARS-CoV-2-positive samples with genome sequenced and lineage definition according to PANGO lineage classification. FINDINGS The BioM 4Plex VOC and commercial RT-PCR assay are equally effective in detecting SARS-CoV-2. Results revealed a specificity of 96.5-100% [95% confidence interval (CI)], a sensitivity of 99.8-100% (95% CI), and an accuracy of 99.8-100% (95% CI). A 99% concordance rate was found between results from the BioM 4Plex VOC and that from available genome sequencing data. MAIN CONCLUSIONS The BioM 4Plex VOC provides an effective solution to detect SARS-CoV-2 infections and screening for VOCs in a single reaction. It is a straightforward method to help us monitor the frequency and distribution of VOCs and develop strategies to better cope with the pandemics.

5.
Braz J Infect Dis ; 25(2): 101542, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-33587923

RESUMO

In response to the Zika epidemics in Brazil, the ZDC molecular assay (Bio-Manguinhos) was developed and registered at the Brazilian Regulatory Agency of Health Surveillance - ANVISA. The circulation of Zika (ZIKV) Dengue (DENV) and Chikungunya (CHIKV) viruses and their clinical similarities are challenges to correctly diagnose these viruses. The simultaneous detection of ZIKV, DENV and CHIKV is an important tool for diagnosis and surveillance. Here, we present the analytical and clinical performance evaluation of ZDC molecular assay (Bio-Manguinhos) at the public health laboratories three years after its registration at ANVISA. The clinical performance demonstrates the ZDC molecular assay (Bio-Manguinhos) has 100% sensitivity and 100% specificity to detect and discriminate ZIKV, CHIKV, and DENV from clinical plasma samples. The ZDC molecular assay (Bio-Manguinhos) results were highly reproducible and no cross-reactivity was seen during testing with a panel of other infectious agents. In conclusion, the ZDC molecular assay (Bio-Manguinhos) is an accurate and reliable tool to monitor Zika, dengue and chikungunya infections in countries like Brazil with simultaneous circulation of the three viruses.


Assuntos
Febre de Chikungunya , Vírus Chikungunya , Vírus da Dengue , Dengue , Infecção por Zika virus , Zika virus , Brasil , Febre de Chikungunya/diagnóstico , Vírus Chikungunya/genética , Dengue/diagnóstico , Vírus da Dengue/genética , Humanos , Laboratórios , Zika virus/genética , Infecção por Zika virus/diagnóstico
6.
Braz. j. infect. dis ; 25(2): 101542, 2021. tab
Artigo em Inglês | LILACS | ID: biblio-1278571

RESUMO

ABSTRACT In response to the Zika epidemics in Brazil, the ZDC molecular assay (Bio-Manguinhos) was developed and registered at the Brazilian Regulatory Agency of Health Surveillance - ANVISA. The circulation of Zika (ZIKV) Dengue (DENV) and Chikungunya (CHIKV) viruses and their clinical similarities are challenges to correctly diagnose these viruses. The simultaneous detection of ZIKV, DENV and CHIKV is an important tool for diagnosis and surveillance. Here, we present the analytical and clinical performance evaluation of ZDC molecular assay (Bio-Manguinhos) at the public health laboratories three years after its registration at ANVISA. The clinical performance demonstrates the ZDC molecular assay (Bio-Manguinhos) has 100% sensitivity and 100% specificity to detect and discriminate ZIKV, CHIKV, and DENV from clinical plasma samples. The ZDC molecular assay (Bio-Manguinhos) results were highly reproducible and no cross-reactivity was seen during testing with a panel of other infectious agents. In conclusion, the ZDC molecular assay (Bio-Manguinhos) is an accurate and reliable tool to monitor Zika, dengue and chikungunya infections in countries like Brazil with simultaneous circulation of the three viruses.


Assuntos
Humanos , Zika virus/genética , Infecção por Zika virus/diagnóstico , Brasil , Vírus Chikungunya/genética , Dengue/diagnóstico , Vírus da Dengue/genética , Febre de Chikungunya/diagnóstico , Laboratórios
7.
Genet Mol Biol ; 43(1): e20180237, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-31644681

RESUMO

Hepatitis C virus (HCV) infection is a worldwide health problem. Nowadays, direct-acting antiviral agents (DAAs) are the main treatment for HCV; however, the high level of virus variability leads to the development of resistance-associated variants (RAVs). Thus, assessing RAVs in infected patients is important for monitoring treatment efficacy. The aim of our study was to investigate the presence of naturally occurring resistance mutations in HCV NS3 and NS5 regions in treatment-naïve patients. Ninety-six anti-HCV positive serum samples from blood donors at the Center of Hematology and Hemotherapy of Santa Catarina State (HEMOSC) were collected retrospectively in 2013 and evaluated in this study. HCV 1a (37.9%), 1b (25.3%), and 3a (36.8%) subtypes were found. The frequency of patients with RAVs in our study was 6.9%. The HCV NS5b sequencing reveled 1 sample with L320F mutation and 4 samples with the C316N/R polymorphism. The analysis of the NS3 region revealed the D168A/G/T (3.45%), S122G (1.15%), and V55A (2.3%) mutations. All samples from genotype 3a (36.8%) presented the V170 I/V non-synonymous mutation. In conclusion, we have shown that mutations in NS3 and NS5b genes are present in Brazilian isolates from therapy-naïve HCV patients.

8.
Braz. j. infect. dis ; 22(5): 418-423, Sept.-Oct. 2018. tab, graf
Artigo em Inglês | LILACS | ID: biblio-974233

RESUMO

ABSTRACT The Brazilian Public Health Service provides freely αPEG-IFN to treat patients infected with HCV. The primary goal of HCV therapy is the long-term elimination of HCV from the blood to reduce the risk of HCV associated complications and death. Patient viremia affects the treatment duration and response, thus influencing clinical decisions. We developed a high-throughput method to perform the quantification of RNA hepatitis C virus (HCV) virus load in plasma samples to monitor patients under treatment. The method is based on a duplex detection, in a one-step real-time RT-PCR assay and it has been validated according to the rules established by the official Brazilian regulatory agency (ANVISA). This new method was compared to a commercial kit (Cobas/Taqman HCV Test v2.0 - Roche), showing virus load results with significant correlation between them (p= 0,012) using commercial and clinical panels. In addition, 611 samples from patients treated with peguilated alfa-interferon (αPEG-IFN) from different regions of Brazil were analyzed. Our one-step real-time RT-PCR assay demonstrated good performance in viral load measurement and in treatment course monitoring, with acceptable sensitivity and specificity values.


Assuntos
Humanos , RNA Viral/isolamento & purificação , Hepatite C/virologia , Hepacivirus/isolamento & purificação , Carga Viral/métodos , Reação em Cadeia da Polimerase em Tempo Real/métodos , Antivirais/uso terapêutico , Polietilenoglicóis/uso terapêutico , Fatores de Tempo , Viremia , Proteínas Recombinantes/uso terapêutico , Brasil , RNA Viral/genética , RNA Viral/sangue , Estudos Prospectivos , Reprodutibilidade dos Testes , Interferon-alfa/uso terapêutico , Hepatite C/tratamento farmacológico , Hepatite C/sangue , Hepacivirus/genética , Técnicas de Genotipagem , Genótipo
9.
Braz J Infect Dis ; 22(5): 418-423, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-30243981

RESUMO

The Brazilian Public Health Service provides freely αPEG-IFN to treat patients infected with HCV. The primary goal of HCV therapy is the long-term elimination of HCV from the blood to reduce the risk of HCV associated complications and death. Patient viremia affects the treatment duration and response, thus influencing clinical decisions. We developed a high-throughput method to perform the quantification of RNA hepatitis C virus (HCV) virus load in plasma samples to monitor patients under treatment. The method is based on a duplex detection, in a one-step real-time RT-PCR assay and it has been validated according to the rules established by the official Brazilian regulatory agency (ANVISA). This new method was compared to a commercial kit (Cobas/Taqman HCV Test v2.0 - Roche), showing virus load results with significant correlation between them (p = 0,012) using commercial and clinical panels. In addition, 611 samples from patients treated with peguilated alfa-interferon (αPEG-IFN) from different regions of Brazil were analyzed. Our one-step real-time RT-PCR assay demonstrated good performance in viral load measurement and in treatment course monitoring, with acceptable sensitivity and specificity values.


Assuntos
Hepacivirus/isolamento & purificação , Hepatite C/virologia , RNA Viral/isolamento & purificação , Reação em Cadeia da Polimerase em Tempo Real/métodos , Carga Viral/métodos , Antivirais/uso terapêutico , Brasil , Genótipo , Técnicas de Genotipagem , Hepacivirus/genética , Hepatite C/sangue , Hepatite C/tratamento farmacológico , Humanos , Interferon-alfa/uso terapêutico , Polietilenoglicóis/uso terapêutico , Estudos Prospectivos , RNA Viral/sangue , RNA Viral/genética , Proteínas Recombinantes/uso terapêutico , Reprodutibilidade dos Testes , Fatores de Tempo , Viremia
10.
Transfusion ; 58(4): 862-870, 2018 04.
Artigo em Inglês | MEDLINE | ID: mdl-29383720

RESUMO

BACKGROUND: The history of the development and implementation of the Brazilian nucleic acid testing (NAT) platform to detect and discriminate among human immunodeficiency virus (HIV), hepatitis C virus (HCV), and hepatitis B virus (HBV) infections in blood donors is described here. The results for the sensitivity, reproducibility, and NAT yield of the platform since program implementation are provided. STUDY DESIGN AND METHODS: The Brazilian NAT HIV, HCV, and HBV kit was developed and evaluated with regard to analytical sensitivity, specificity, intralot and interlot reproducibility, interfering substances, and genotype and diagnostic sensitivity. Additionally, a sample of identified NAT-yield cases was characterized with regard to viral load. RESULTS: The 95% limits of detection for HIV, HCV, and HBV were 68.02, 102.35, and 9.08 IU/mL, respectively. All replicates were detected with reproducibility assays between the acceptable values. A total of 13,610,536 blood donors was screened from 2010 to 2016, and 63 HIV-yield cases and 28 HCV-yield cases were detected. Among 5,795,424 blood donors screened for HBV from 2014 to 2016, 42 yield cases were found. CONCLUSION: The Brazilian NAT HIV, HCV, and HBV kit is an automated NAT system suitable for routine blood donor screening in a completely traceable process. The analytical sensitivity as well as the diagnostic sensitivity fulfilled all requirements set by the health ministry for blood donor screening. A significant number of transmission cases were prevented by the implementation of this important program.


Assuntos
Doadores de Sangue , Segurança do Sangue , DNA Viral/sangue , Infecções por HIV/diagnóstico , Hepatite B/diagnóstico , Hepatite C/diagnóstico , Reação em Cadeia da Polimerase em Tempo Real , Viremia/diagnóstico , Automação , Segurança do Sangue/instrumentação , Segurança do Sangue/métodos , Segurança do Sangue/normas , Brasil , Infecções por HIV/sangue , Hepatite B/sangue , Hepatite C/sangue , Humanos , Programas de Rastreamento/métodos , Reação em Cadeia da Polimerase em Tempo Real/instrumentação , Reação em Cadeia da Polimerase em Tempo Real/métodos , Reação em Cadeia da Polimerase em Tempo Real/normas , Padrões de Referência , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Carga Viral , Viremia/transmissão
11.
Antimicrob Agents Chemother ; 60(7): 4380-3, 2016 07.
Artigo em Inglês | MEDLINE | ID: mdl-27139469

RESUMO

This study reveals the presence of different carbapenemase genes (blaKPC, blaNDM, blaGES, and blaOXA48-like genes) detected directly from water samples and clonal dispersion (by pulsed-field gel electrophoresis [PFGE] and multilocus sequence typing [MLST]) of KPC-2-producing Enterobacteriaceae in two important urban aquatic matrixes from Rio de Janeiro, Brazil, highlighting the role of aquatic environments as gene pools and the possibility of community spreading.


Assuntos
Antibacterianos/farmacologia , Proteínas de Bactérias/metabolismo , beta-Lactamases/metabolismo , Proteínas de Bactérias/genética , Brasil , Eletroforese em Gel de Campo Pulsado , Enterobacteriaceae/efeitos dos fármacos , Enterobacteriaceae/enzimologia , Enterobacteriaceae/genética , Testes de Sensibilidade Microbiana , Tipagem de Sequências Multilocus , beta-Lactamases/genética
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA