Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 47
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
1.
Bioengineering (Basel) ; 11(5)2024 Apr 28.
Artigo em Inglês | MEDLINE | ID: mdl-38790303

RESUMO

The production of biomedical devices able to appropriately interact with the biological environment is still a great challenge. Synthetic materials are often employed, but they fail to replicate the biological and functional properties of native tissues, leading to a variety of adverse effects. Several commercial products are based on chemically treated xenogeneic tissues: their principal drawback is due to weak mechanical stability and low durability. Recently, decellularization has been proposed to bypass the drawbacks of both synthetic and biological materials. Acellular materials can integrate with host tissues avoiding/mitigating any foreign body response, but they often lack sufficient patency and impermeability. The present paper investigates an innovative approach to the realization of hybrid materials that combine decellularized bovine pericardium with polycarbonate urethanes. These hybrid materials benefit from the superior biocompatibility of the biological tissue and the mechanical properties of the synthetic polymers. They were assessed from physicochemical, structural, mechanical, and biological points of view; their ability to promote cell growth was also investigated. The decellularized pericardium and the polymer appeared to well adhere to each other, and the two sides were distinguishable. The maximum elongation of hybrid materials was mainly affected by the pericardium, which allows for lower elongation than the polymer; this latter, in turn, influenced the maximum strength achieved. The results confirmed the promising features of hybrid materials for the production of vascular grafts able to be repopulated by circulating cells, thus, improving blood compatibility.

2.
BMC Vet Res ; 20(1): 153, 2024 Apr 24.
Artigo em Inglês | MEDLINE | ID: mdl-38659026

RESUMO

BACKGROUND: Melting corneal ulcers are a serious condition that affects a great number of animals and people around the world and it is characterised by a progressive weakening of the tissue leading to possible severe ophthalmic complications, such as visual impairment or blindness. This disease is routinely treated with medical therapy and keratoplasty, and recently also with alternative regenerative therapies, such as cross-linking, amniotic membrane transplant, and laser. Plasma medicine is another recent example of regenerative treatment that showed promising results in reducing the microbial load of corneal tissue together with maintaining its cellular vitality. Since the effect of helium plasma application on corneal mechanical viscoelasticity has not yet been investigated, the aim of this study is first to evaluate it on ex vivo porcine corneas for different exposition times and then to compare the results with previous data on cross-linking treatment. RESULTS: 94 ex vivo porcine corneas divided into 16 populations (healthy or injured, fresh or cultured and treated or not with plasma or cross-linking) were analysed. For each population, a biomechanical analysis was performed by uniaxial stress-relaxation tests, and a statistical analysis was carried out considering the characteristic mechanical parameters. In terms of equilibrium normalised stress, no statistically significant difference resulted when the healthy corneas were compared with lesioned plasma-treated ones, independently of treatment time, contrary to what was obtained about the cross-linking treated corneas which exhibited more intense relaxation phenomena. CONCLUSIONS: In this study, the influence of the Helium plasma treatment was observed on the viscoelasticity of porcine corneas ex vivo, by restoring in lesioned tissue a degree of relaxation similar to the one of the native tissue, even after only 2 min of application. Therefore, the obtained results suggest that plasma treatment is a promising new regenerative ophthalmic therapy for melting corneal ulcers, laying the groundwork for further studies to correlate the mechanical findings with corneal histology and ultrastructural anatomy after plasma treatment.


Assuntos
Córnea , Hélio , Gases em Plasma , Animais , Suínos , Córnea/efeitos dos fármacos , Gases em Plasma/farmacologia , Gases em Plasma/uso terapêutico , Fenômenos Biomecânicos , Álcalis , Pressão Atmosférica , Úlcera da Córnea/veterinária , Úlcera da Córnea/terapia
3.
Phys Eng Sci Med ; 2024 Apr 10.
Artigo em Inglês | MEDLINE | ID: mdl-38598066

RESUMO

Healthy cornea guarantees the refractive power of the eye and the protection of the inner components, but injury, trauma or pathology may impair the tissue shape and/or structural organization and therefore its material properties, compromising its functionality in the ocular visual process. It turns out that biomechanical research assumes an essential role in analysing the morphology and biomechanical response of the cornea, preventing pathology occurrence, and improving/optimising treatments. In this review, ex vivo, in vivo and in silico methods for the corneal mechanical characterization are reported. Experimental techniques are distinct in testing mode (e.g., tensile, inflation tests), samples' species (human or animal), shape and condition (e.g., healthy, treated), preservation methods, setup and test protocol (e.g., preconditioning, strain rate). The meaningful results reported in the pertinent literature are discussed, analysing differences, key features and weaknesses of the methodologies adopted. In addition, numerical techniques based on the finite element method are reported, incorporating the essential steps for the development of corneal models, such as geometry, material characterization and boundary conditions, and their application in the research field to extend the experimental results by including further relevant aspects and in the clinical field for diagnostic procedure, treatment and planning surgery. This review aims to analyse the state-of-art of the bioengineering techniques developed over the years to study the corneal biomechanics, highlighting their potentiality to improve diagnosis, treatment and healing process of the corneal tissue, and, at the same, pointing out the current limits in the experimental equipment and numerical tools that are not able to fully characterize in vivo corneal tissues non-invasively and discourage the use of finite element models in daily clinical practice for surgical planning.

4.
J Anat ; 244(4): 639-653, 2024 04.
Artigo em Inglês | MEDLINE | ID: mdl-38030148

RESUMO

The suprapatellar fat pad is an adipose tissue located in the anterior knee whose role in osteoarthritis is still debated. Considering that anatomy drives function, the aim of this histotopographic study was to investigate the specific morphological features of the suprapatellar fat pad versus the infrapatellar fat pad in the absence of osteoarthritis, for a broad comparative analysis. Suprapatellar fat pad and infrapatellar fat pad tissue samples (n = 10/group) underwent microscopical/immunohistochemical staining and transmission electron microscopy analysis; thus, tissue-specific characteristics (i.e., vessels and nerve endings presence, lobuli, adipocytes features, septa), including extracellular matrix proteins prevalence (collagens, elastic fibers), were focused. Multiphoton microscopy was also adopted to evaluate collagen fiber orientation within the samples by Fast Fourier Transform (coherency calculation). The absence of inflammation was confirmed, and comparable counted vessels and nerve endings were shown. Like the infrapatellar fat pad, the suprapatellar fat pad appeared as a white adipose tissue with lobuli and septa of comparable diameter and thickness, respectively. Tissue main characteristics were also proved by both semithin sections and transmission electron microscopy analysis. The suprapatellar fat pad adipocytes were roundish and with a smaller area, perimeter, and major axis than that of the infrapatellar fat pad. The collagen fibers surrounding them showed no significant difference in collagen type I and significantly higher values for collagen type III in the infrapatellar fat pad group. Regarding the septa, elastic fiber content was statistically comparable between the two groups, even though more represented by the suprapatellar fat pad. Total collagen was significantly higher in the infrapatellar fat pad and comparing collagen type I and type III they were similarly represented in the whole cohort despite collagen type I appearing to be higher in the infrapatellar fat pad than in the suprapatellar fat pad and vice versa for collagen type III. Second harmonic generation microscopy confirmed through coherency calculation an anisotropic distribution of septa collagen fibers. From a mechanical point of view, the different morphological characteristics determined a major stiffness for the infrapatellar fat pad with respect to the suprapatellar fat pad. This study provides, for the first time, a topographic description of the suprapatellar fat pad compared to the infrapatellar fat pad; differences between the two groups may be attributed to a different anatomical location within the knee; the results gathered here may be useful for a more complete interpretation of osteoarthritis disease, involving not only cartilage but the whole joint.


Assuntos
Colágeno Tipo I , Osteoartrite , Humanos , Colágeno Tipo III , Tecido Adiposo/anatomia & histologia , Articulação do Joelho/anatomia & histologia
5.
Life (Basel) ; 13(12)2023 Nov 29.
Artigo em Inglês | MEDLINE | ID: mdl-38137878

RESUMO

It is a common experience, reported by patients who have undergone manual therapy that uses deep friction, to perceive soreness in treatment areas; however, it is still not clear what causes it and if it is therapeutically useful or a simple side effect. The purpose of this narrative review is to determine whether manual and physical therapies can catalyze an inflammatory process driven by HA fragments. The literature supports the hypothesis that mechanical stress can depolymerize into small pieces at low molecular weight and have a high inflammatory capacity. Many of these pieces are then further degraded into small oligosaccharides. Recently, it has been demonstrated that oligosaccharides are able to stop this inflammatory process. These data support the hypothesis that manual therapy that uses deep friction could metabolize self-aggregated HA chains responsible for increasing loose connective tissue viscosity, catalyzing a local HA fragment cascade that will generate soreness but, at the same time, facilitate the reconstitution of the physiological loose connective tissue properties. This information can help to explain the meaning of the inflammatory process as well as the requirement for it for the long-lasting resolution of these alterations.

6.
Biomedicines ; 11(7)2023 Jul 08.
Artigo em Inglês | MEDLINE | ID: mdl-37509581

RESUMO

Biomechanical studies are expanding across a variety of fields, from biomedicine to biomedical engineering. From the molecular to the system level, mechanical stimuli are crucial regulators of the development of organs and tissues, their growth and related processes such as remodelling, regeneration or disease. When dealing with cell mechanics, various experimental techniques have been developed to analyse the passive response of cells; however, cell variability and the extraction process, complex experimental procedures and different models and assumptions may affect the resulting mechanical properties. For these purposes, this review was aimed at collecting the available literature focused on experimental chondrocyte and chondron biomechanics with direct connection to their biochemical functions and activities, in order to point out important information regarding the planning of an experimental test or a comparison with the available results. In particular, this review highlighted (i) the most common experimental techniques used, (ii) the results and models adopted by different authors, (iii) a critical perspective on features that could affect the results and finally (iv) the quantification of structural and mechanical changes due to a degenerative pathology such as osteoarthritis.

7.
Comput Methods Programs Biomed ; 238: 107594, 2023 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-37207463

RESUMO

BACKGROUND AND OBJECTIVE: In the field of urology, the pressure-flow study (PFS) is an essential urodynamics practise which requires the patient's transurethral catheterization during the voiding phase of micturition to evaluate the functionality of the lower urinary tract (LUT) and reveal the pathophysiology of its dysfunctionality. However, the literature evidences confusion regarding the interference of the catheterization on the urethral pressure-flow behaviour. METHODS: The present research study represents the first Computational Fluid-Dynamics (CFD) approach to this urodynamics issue, analysing the influence of a catheter in the male LUT through case studies which included the inter-individual and intra-individual dependence. A set of four three dimensional (3D) models of the male LUT, different in urethral diameters, and a set of three 3D models of the transurethral catheter, diverse in calibre, were developed leading to 16 CFD non-catheterized either catheterized configurations, to describe the typical micturition scenario considering both urethra and catheter characteristics. RESULTS: The developed CFD simulations showed that the urine flow field during micturition was influenced by the urethral cross-sectional area and each catheter determined a specific decrease in flow rate if compared to the relative free uroflow. CONCLUSIONS: In-silico methods allow to analyse relevant urodynamics aspects, which could not be investigated in vivo, and may support the clinical PFS to reduce uncertainty on urodynamic diagnosis.


Assuntos
Uretra , Bexiga Urinária , Humanos , Masculino , Micção/fisiologia , Catéteres , Urodinâmica/fisiologia
8.
Bioengineering (Basel) ; 10(2)2023 Jan 19.
Artigo em Inglês | MEDLINE | ID: mdl-36829631

RESUMO

By leveraging the recent development of artificial intelligence algorithms, several medical sectors have benefited from using automatic segmentation tools from bioimaging to segment anatomical structures. Segmentation of the musculoskeletal system is key for studying alterations in anatomical tissue and supporting medical interventions. The clinical use of such tools requires an understanding of the proper method for interpreting data and evaluating their performance. The current systematic review aims to present the common bottlenecks for musculoskeletal structures analysis (e.g., small sample size, data inhomogeneity) and the related strategies utilized by different authors. A search was performed using the PUBMED database with the following keywords: deep learning, musculoskeletal system, segmentation. A total of 140 articles published up until February 2022 were obtained and analyzed according to the PRISMA framework in terms of anatomical structures, bioimaging techniques, pre/post-processing operations, training/validation/testing subset creation, network architecture, loss functions, performance indicators and so on. Several common trends emerged from this survey; however, the different methods need to be compared and discussed based on each specific case study (anatomical region, medical imaging acquisition setting, study population, etc.). These findings can be used to guide clinicians (as end users) to better understand the potential benefits and limitations of these tools.

9.
Bioengineering (Basel) ; 10(2)2023 Jan 29.
Artigo em Inglês | MEDLINE | ID: mdl-36829669

RESUMO

Hollow organs are visceral organs that are hollow tubes or pouches (such as the intestine or the stomach, respectively) or that include a cavity (such as the heart) and which subserve a vital function [...].

10.
Bioengineering (Basel) ; 10(2)2023 Feb 07.
Artigo em Inglês | MEDLINE | ID: mdl-36829719

RESUMO

Human Fascia Lata (FL) is a connective tissue with a multilayered organization also known as aponeurotic fascia. FL biomechanics is influenced by its composite structure formed by fibrous layers (usually two) separated by loose connective tissue. In each layer, most of the collagen fibers run parallel in a distinct direction (with an interlayer angle that usually ranges from 75-80°), mirroring the fascia's ability to adapt and withstand specific tensile loads. Although FL is a key structure in several musculoskeletal dysfunctions and in tissue engineering, literature still lacks the evidence that proves tissue anisotropy according to predominant collagen fiber directions. For this purpose, this work aims to analyze the biomechanical properties of ex-vivo FL (collected from fresh-frozen human donors) by performing uniaxial tensile tests in order to highlight any differences with respect to loading directions. The experimental outcomes showed a strong anisotropic behavior in accordance with principal collagen fibers directions, which characterize the composite structure. These findings have been implemented to propose a first constitutive model able to mimic the intra- and interlayer interactions. Both approaches could potentially support surgeons in daily practices (such as graft preparation and placement), engineers during in silico simulation, and physiotherapists during musculoskeletal rehabilitation, to customize a medical intervention based on each specific patient and clinical condition.

11.
Artif Organs ; 47(4): 617-639, 2023 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-36374175

RESUMO

Artificial sphincters (ASs) are used to replace the function of the biological sphincters in case of severe urinary and fecal incontinence (UI and FI), and gastroesophageal reflux disease (GERD). The design of ASs is established on different mechanisms, e.g., magnetic forces or hydraulic pressure, with the final goal to achieve a implantable and durable AS. In clinical practice, the implantation of in-commerce AS is considered a reasonable solution, despite the sub-optimal clinical outcomes. The failure of these surgeries is due to the malfunction of the devices (between 46 and 51%) or the side effects on the biological tissues (more than 38%), such as infection and atrophy. Concentrating on this latter characteristic, particular attention has been given to the interaction between the biological tissues and AS, pointing out the closing mechanism around the duct and the effect on the tissues. To analyze this aspect, an overview of existing commercial/ready-on-market ASs for GERD, UI, and FI, together with the clinical outcomes available from the in-commerce AS, is given. Moreover, this invited review discusses ongoing developments and future research pathways for creating novel ASs. The application of engineering principles and design concepts to medicine enhances the quality of healthcare and improves patient outcomes. In this context, computational methods represent an innovative solution in the design of ASs, proving data on the occlusive force and pressure necessary to guarantee occlusion and avoid tissue damage, considering the coupling between different device sizes and individual variability.


Assuntos
Incontinência Fecal , Incontinência Urinária , Esfíncter Urinário Artificial , Humanos , Incontinência Fecal/cirurgia , Próteses e Implantes , Incontinência Urinária/cirurgia
12.
Bioengineering (Basel) ; 11(1)2023 Dec 31.
Artigo em Inglês | MEDLINE | ID: mdl-38247919

RESUMO

Plantar adipose tissue is a connective tissue whose structural configuration changes according to the foot region (rare or forefoot) and is related to its mechanical role, providing a damping system able to adsorb foot impact and bear the body weight. Considering this, the present work aims at fully describing the plantar adipose tissue's behaviour and developing a proper constitutive formulation. Unconfined compression tests and indentation tests have been performed on samples harvested from human donors and cadavers. Experimental results provided the initial/final elastic modulus for each specimen and assessed the non-linear and time-dependent behaviour of the tissue. The different foot regions were investigated, and the main differences were observed when comparing the elastic moduli, especially the final elastic ones. It resulted in a higher level for the medial region (89 ± 77 MPa) compared to the others (from 51 ± 29 MPa for the heel pad to 11 ± 7 for the metatarsal). Finally, results have been used to define a visco-hyperelastic constitutive model, whose hyperelastic component, which describes tissue non-linear behaviour, was described using an Ogden formulation. The identified and validated tissue constitutive parameters could serve, in the early future, for the computational model of the healthy foot.

13.
Life (Basel) ; 14(1)2023 Dec 30.
Artigo em Inglês | MEDLINE | ID: mdl-38255682

RESUMO

Urinary incontinence is still an underestimated problem due to its anatomical complexity and social taboo. Most of the time, it is believed to affect predominantly the elderly female population, and the literature still lacks data on its presence in the younger and male populations. Its relationship with other pelvic floor dysfunctions (PFDs) and sport activity remains an open topic. Thus, the present study surveyed 342 subjects of both genders, ranging from 18 to 39 y/o and with different sport activity levels, to understand the prevalence of PFDs (such as haemorrhoids, anal fissures, involuntary urinary/faecal leakage, and urgency). The results also showed a significative prevalence in younger, sporty, and male people. Approximately one third of the population had urinary incontinence mostly during stress activities (sport activity: 17%, cough/sneeze: 13%). The statistical analysis confirmed a higher prevalence in the cases of a light (32%) and intense (41%) sport activity level and a protective role of sport if practiced between 5 and 10 h/week, with bodybuilding/CrossFit and running seeming to be the riskiest sports. The relationship with the other PFDs showed a statistically significant dependence with most of them, confirming that urinary incontinence cannot be considered a separate problem from the other PFDs.

14.
Biomedicines ; 10(6)2022 Jun 09.
Artigo em Inglês | MEDLINE | ID: mdl-35740391

RESUMO

Several studies have investigated cartilage degeneration and inflammatory subchondral bone and synovial membrane changes using magnetic resonance (MR) in osteoarthritis (OA) patients. Conversely, there is a paucity of data exploring the role of knee ligaments, infrapatellar fat pad (IFP), and suprapatellar fat pad (SFP) in knee OA compared to post-traumatic cohorts of patients. Therefore, the aim of this study was to analyze the volumetric and morphometric characteristics of the following joint tissues: IFP (volume, surface, depth, femoral and tibial arch lengths), SFP (volume, surface, oblique, antero−posterior, and cranio−caudal lengths), anterior (ACL) and posterior cruciate ligament (PCL) (volume, surface, and length), and patellar ligament (PL) (volume, surface, arc, depth, and length). Eighty-nine MR images were collected in the following three groups: (a) 32 patients with meniscal tears, (b) 29 patients with ACL rupture (ACLR), and (c) 28 patients affected by end-stage OA. Volume, surface, and length of both ACL and PCL were determined in groups a and c. A statistical decrease of IFP volume, surface, depth, femoral and tibial arch lengths was found in end-stage OA compared to patients with meniscal tear (p = 0.002, p = 0.008, p < 0.0001, p = 0.028 and p < 0.001, respectively) and patients with ACLR (p < 0.0001, p < 0.0001, p = 0.008 and p = 0.011, respectively). An increment of volume and surface SFP was observed in group b compared to both groups a and c, while no differences were found in oblique, antero−posterior, and cranio−caudal lengths of SFP among the groups. No statistical differences were highlighted comparing volume, surface, arc, and length of PL between the groups, while PL depth was observed to be decreased in end-OA patients compared with meniscal tear patients (p = 0.023). No statistical differences were observed comparing ACL and PCL lengths between patients undergoing meniscectomy and TKR. Our study confirms that IFP MR morphometric characteristics are different between controls and OA, supporting an important role of IFP in OA pathology and progression in accordance with previously published studies. In addition, PL depth changes seem to be associated with OA pathology. Multivariate analysis confirmed that OA patients had a smaller IFP compared to patients with meniscal tears, confirming its involvement in OA.

15.
J Mech Behav Biomed Mater ; 125: 104914, 2022 01.
Artigo em Inglês | MEDLINE | ID: mdl-34715641

RESUMO

Gastric diseases are one of the most relevant healthcare problems worldwide. Interventions and therapies definition/design mainly derive from biomedical and clinical expertise. Computational biomechanics, with particular regard to the finite element method, provides hard-to-measure quantities during in-vivo tests, such as strain and stress distribution, leading to a more comprehensive and promising approach to improve the effectiveness of many different clinical activities. However, reliable finite element models of biological organs require appropriate constitutive formulations of building tissues, whose parameters identification needs an experimental campaign consisting in different tests on human tissues and organs. The aim of the reported here research activities was the identification of mechanical properties of human gastric tissues. Human gastric specimens were tested at tissue, sub-structural and structural levels, by tensile, membrane indentation and inflation tests, respectively. On the other hand, animal experimentations on tissue layers from literature pointed out the mechanical response at sub-tissue level during tensile loading conditions. In detail, the analysis of experimental results at sub-tissue and tissue levels led to a fibre-reinforced visco-hyperelastic constitutive formulation and to the identification of gastric layers mechanical behaviour. Results from experimentations on human samples were coupled with data derived from animal models. Data from sub-structural and structural experimentations were exploited to upgrade and validate the constitutive formulations and parameters. The developed investigations led to a reliable constitutive framework of human gastric tissues that both describe stomach mechanical functionality and allow computational investigations. Indeed, the comparisons among average computational data and experimental medians provided the following RMSEs (Root Mean Square Errors): 0.89 N, 0.15 N for corpus and fundus during membrane indentation test, respectively, and 0.44 kPa during inflation test. Accounting for the magnitude of experimental and computational data, the RMSEs can be considered low and acceptable because they concerned biological samples. In fact, biological tissues and structures are affected by a high inherent inter-samples' variability, which is detectable in both the geometrical configuration and the mechanical behaviour. The specific values of the here reported RMSEs ensured the reliability of the achieved parameters and the quality of the overall developed procedure. Reliable computational models of the gastric district could become efficient clinical tools to find out the main crucial aspects of bariatric procedures, such as the mechanical stimulation of gastric mechano-receptors. Moreover, the methods of computational biomechanics will permit to run the preliminary tests of new and innovative bariatric procedures, on one hand, predicting the successful rate and the effectiveness, and, on other hand, reducing the use of animal testing.


Assuntos
Estômago , Fenômenos Biomecânicos , Biofísica , Humanos , Reprodutibilidade dos Testes
16.
J Biomech ; 131: 110931, 2022 01.
Artigo em Inglês | MEDLINE | ID: mdl-34972018

RESUMO

The infrapatellar fat pad (IFP) is an adipose tissue present in the knee that lies between the patella, femur, meniscus and tibia, filling the space between these structures. IFP facilitates the distribution of the synovial fluid and may act to absorb impulsive actions generated through the joint. IFP in osteoarthritis (OA) pathology undergoes structural changes characterized by inflammation, hypertrophy and fibrosis. The aim of the present study is to analyze the mechanical behavior of the IFP in patients affected by end-stage OA. A specific test fixture was designed and indentation tests were performed on IFP specimens harvested from OA patients who underwent total knee arthroplasty. Experiments allowed to assess the typical features of mechanical response, such as non-linear stress-strain behavior and time-dependent effects. Results from mechanical experimentations were implemented within the framework of a visco-hyperelastic constitutive theory, with the aim to provide data for computational modelling of OA IFP role in knee mechanics. Initial and final indentation stiffness were calculated for all subjects and statistical results reveled that OA IFP mechanics was not significantly influenced by gender, BMI and sample preparation. OA IFP mechanical behavior was also compared to that of other adipose tissues. OA IFP appeared to be a stiffer adipose tissue compared to subcutaneous, visceral adipose tissues and heel fat pads. It is reasonable that fibrosis induces a modification of the tissue destabilizing the normal distribution of forces in the joint during movement, causing a worsening of the disease.


Assuntos
Artroplastia do Joelho , Osteoartrite do Joelho , Tecido Adiposo , Humanos , Articulação do Joelho , Patela
17.
BMC Vet Res ; 17(1): 340, 2021 Oct 28.
Artigo em Inglês | MEDLINE | ID: mdl-34711207

RESUMO

BACKGROUND: Cornea is a composite tissue exhibiting nonlinear and time-dependent mechanical properties. Corneal ulcers are one of the main pathologies that affect this tissue, disrupting its structural integrity and leading to impaired functions. In this study, uniaxial tensile and stress-relaxation tests are developed to evaluate stress-strain and time-dependent mechanical behaviour of porcine corneas. RESULTS: The samples are split in two groups: some corneas are analysed in an unaltered state (healthy samples), while others are injured with alkaline solution to create an experimental ulcer (lesioned samples). Furthermore, within each group, corneas are examined in two conditions: few hours after the enucleation (fresh samples) or after 7 days in a specific culture medium for the tissue (cultured samples). Finally, another condition is added: corneas from all the groups undergo or not a cross-linking treatment. In both stress-strain and stress-relaxation tests, a weakening of the tissue is observed due to the imposed conditions (lesion, culture and treatment), represented by a lower stiffness and increased stress-relaxation. CONCLUSIONS: Alkali-induced corneal stromal melting determines changes in the mechanical response that can be related to a damage at microstructural level. The results of the present study represent the basis for the investigation of traditional and innovative corneal therapies.


Assuntos
Córnea/efeitos dos fármacos , Córnea/fisiologia , Úlcera da Córnea/veterinária , Técnicas de Cultura de Órgãos/veterinária , Doenças dos Suínos/patologia , Animais , Úlcera da Córnea/induzido quimicamente , Úlcera da Córnea/patologia , Suínos , Doenças dos Suínos/induzido quimicamente
18.
Front Med (Lausanne) ; 8: 661403, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34041253

RESUMO

The infrapatellar fat pad (IFP) is actively involved in knee osteoarthritis (OA). However, a proper description of which developmental modifications occur in the IFP along with age and in absence of joint pathological conditions, is required to adequately describe its actual contribution in OA pathophysiology. Here, two IFP sources were compared: (a) IFP from healthy young patients undergoing anterior-cruciate ligament (ACL) reconstruction for ACL rupture (n = 24); (b) IFP from elderly cadaver donors (n = 23). After histopathological score assignment to confirm the absence of inflammatory features (i.e., inflammatory infiltrate and increased vascularity), the adipocytes morphology was determined; moreover, extracellular matrix proteins were studied through histology and Second Harmonic Generation approach, to determine collagens content and orientation by Fast Fourier Transform and OrientationJ. The two groups were matched for body mass index. No inflammatory signs were observed, while higher area, perimeter, and equivalent diameter and volume were detected for the adipocytes in the elderly group. Collagen III displayed higher values in the young group and a lower total collagen deposition with aging was identified. However, collagen I/III ratio and the global architecture of the samples were not affected. A higher content in elastic fibers was observed around the adipocytes for the ACL-IFPs and in the septa cadaver donor-IFPs, respectively. Age affects the characteristics of the IFP tissue also in absence of a pathological condition. Variable mechanical stimulation, depending on age-related different mobility, could be speculated to exert a role in tissue remodeling.

19.
Updates Surg ; 73(6): 2253-2262, 2021 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-33817769

RESUMO

LSG is one of the most performed bariatric procedures worldwide. It is a safe and effective operation with a low complication rate. Unsatisfactory weight loss/regain may occur, suggesting that the operation design could be improved. A bioengineering approach might significantly help in avoiding the most common complications. Computational models of the sleeved stomach after LSG were developed according to bougie size (range 27-54 Fr). The endoluminal pressure and the basal volume were computed at different intragastric pressures. At an inner pressure of 22.5 mmHg, the basal volume of the 54 Fr configuration was approximately 6 times greater than that of the 27 Fr configuration (57.92 ml vs 9.70 ml). Moreover, the elongation distribution of the gastric wall was assessed to quantify the effect on mechanoreceptors impacting satiety by differencing regions and layers. An increasing trend in elongation strain with increasing bougie size was observed in all cases. The most stressed region and layer were the antrum (approximately 25% higher stress than that in the corpus at 37.5 mmHg) and mucosa layer (approximately 7% higher stress than that in the muscularis layer at 22.5 mmHg), respectively. In addition, the pressure-volume behaviors were reported. Computational models and bioengineering methods can help to quantitatively identify some critical aspects of the "design" of bariatric operations to plan interventions, and predict and increase the success rate. Moreover, computational tools can support the development of innovative bariatric procedures, potentially skipping invasive approaches.


Assuntos
Cirurgia Bariátrica , Laparoscopia , Obesidade Mórbida , Gastrectomia , Humanos , Obesidade Mórbida/cirurgia , Estudos Retrospectivos , Resultado do Tratamento , Redução de Peso
20.
Bioengineering (Basel) ; 7(4)2020 Dec 09.
Artigo em Inglês | MEDLINE | ID: mdl-33317122

RESUMO

BACKGROUND: The stomach is a hollow organ of the gastrointestinal tract, on which bariatric surgery (BS) is performed for the treatment of obesity. Even though BS is the most effective treatment for severe obesity, drawbacks and complications are still present because the intervention design is largely based on the surgeon's expertise and intraoperative decisions. Bioengineering methods can be exploited to develop computational tools for more rational presurgical design and planning of the intervention. METHODS: A computational mechanical model of the stomach was developed, considering the actual complexity of the biological structure, as the nonhomogeneous and multilayered configuration of the gastric wall. Mechanical behavior was characterized by means of an anisotropic visco-hyperelastic constitutive formulation of fiber-reinforced conformation, nonlinear elastic response, and time-dependent behavior, which assume the typical features of gastric wall mechanics. Model applications allowed for an analysis of the influence of BS techniques on stomach mechanical functionality through different computational analyses. RESULTS: Computational results showed that laparoscopic sleeve gastrectomy and endoscopic sleeve gastroplasty drastically alter stomach capacity and stiffness, while laparoscopic adjustable gastric banding modestly affects stomach stiffness and capacity. Moreover, the mean elongation strain values, which are correlated to the mechanical stimulation of gastric receptors, were elevated in laparoscopic adjustable gastric banding compared to other procedures. CONCLUSIONS: The investigation of stomach mechanical response through computational models provides information on different topics such as stomach capacity and stiffness and the mechanical stimulation of gastric receptors, which interact with the brain to control satiety. These data can provide reliable support to surgeons in the presurgical decision-making process.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA