Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
1.
Circ Cardiovasc Interv ; 16(7): e012636, 2023 07.
Artigo em Inglês | MEDLINE | ID: mdl-37417226

RESUMO

BACKGROUND: Anomalous aortic origin of coronary artery (AAOCA) with intramural segment is associated with risk of sudden cardiac death, probably related to a compressive mechanism exerted by the aorta. However, the intramural compression occurrence and magnitude during the cardiac cycle remain unknown. We hypothesized that (1) in end diastole, the intramural segment is narrower, more elliptic, and has greater resistance than extramural segment; (2) the intramural segment experiences a further compression in systole; and (3) morphometry and its systolic changes vary within different lumen cross-sections of the intramural segment. METHODS: Phasic changes of lumen cross-sectional coronary area, roundness (minimum/maximum lumen diameter), and hemodynamic resistance (Poiseuille law for noncircular sections) were derived from intravascular ultrasound pullbacks at rest for the ostial, distal intramural, and extramural segments. Data were obtained for 35 AAOCA (n=23 with intramural tract) after retrospective image-based gating and manual lumen segmentation. Differences between systolic and end-diastolic phases in each section, between sections of the same coronary, and between AAOCA with and without intramural tract were assessed by nonparametric statistical tests. RESULTS: In end diastole, both the ostial and distal intramural sections were more elliptical (P<0.001) than the reference extramural section and the correspondent sections in AAOCA without intramural segment. In systole, AAOCA with intramural segment showed a flattening at the ostium (-6.76% [10.82%]; P=0.024) and a flattening (-5.36% [16.56%]; P=0.011), a narrowing (-4.62% [11.38%]; P=0.020), and a resistance increase (15.61% [30.07%]; P=0.012) at the distal intramural section. No-intramural sections did not show morphological changes during the entire cardiac cycle. CONCLUSIONS: AAOCA with intramural segment has pathological segment-specific dynamic compression mainly in the systole under resting conditions. Studying AAOCA behavior with intravascular ultrasound during the cardiac cycle may help to evaluate and quantify the severity of the narrowing.


Assuntos
Anomalias dos Vasos Coronários , Vasos Coronários , Humanos , Vasos Coronários/diagnóstico por imagem , Vasos Coronários/patologia , Estudos Retrospectivos , Estudos Transversais , Anomalias dos Vasos Coronários/diagnóstico por imagem , Anomalias dos Vasos Coronários/complicações , Resultado do Tratamento , Aorta/diagnóstico por imagem
2.
Front Cardiovasc Med ; 9: 1076359, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36704466

RESUMO

An 8-year-old girl, diagnosed with mid-aortic syndrome (MAS) at the age of 2 months and under antihypertensive therapy, presented with severe systemic hypertension (>200/120 mmHg). Computed tomography (CT) examination revealed aortic aneurysm between severe stenoses at pre- and infra-renal segments, and occlusion of principal splanchnic arteries with peripheral collateral revascularization. Based on CT imaging, preoperative three-dimensional (3D) anatomy was reconstructed to assess aortic dimensions and a dedicated in vitro planning platform was designed to investigate the feasibility of a stenting procedure under fluoroscopic guidance. The in vitro system was designed to incorporate a translucent flexible 3D-printed patient-specific model filled with saline. A covered 8-zig 45-mm-long Cheatham-Platinum (CP) stent and a bare 8-zig, 34-mm-long CP stent were implanted with partial overlap to treat the stenoses (global peak-to-peak pressure gradient > 60 mmHg), excluding the aneurysm and avoiding risk of renal arteries occlusion. Percutaneous procedure was successfully performed with no residual pressure gradient and exactly replicating the strategy tested in vitro. Also, as investigated on the 3D-printed model, additional angioplasty was feasible across the frames of the stent to improve bilateral renal flow. Postoperative systemic pressure significantly reduced (130/70 mmHg) as well as dosage of antihypertensive therapy. This is the first report demonstrating the use of a 3D-printed model to effectively plan percutaneous intervention in a complex pediatric MAS case: taking full advantage of the combined use of a patient-specific 3D model and a dedicated in vitro platform, feasibility of the stenting procedure was successfully tested during pre-procedural assessment. Hence, use of patient-specific 3D-printed models and in vitro dedicated platforms is encouraged to assist pre-procedural planning and personalize treatment, thus enhancing intervention success.

3.
J Biomech Eng ; 140(11)2018 Nov 01.
Artigo em Inglês | MEDLINE | ID: mdl-30098160

RESUMO

Anomalous aortic origin of coronary arteries (AAOCA) is a congenital disease that can lead to cardiac ischemia during intense physical activity. Although AAOCA is responsible for sudden cardiac death (SCD) among young athletes and soldiers, the mechanisms underlying the coronary occlusion during physical effort still have to be clarified. The present study investigates the correlation between geometric features of the anomaly and coronary lumen narrowing under aortic root dilatations. Idealized parametric computer-aided designed (CAD) models of the aortic root with anomalous and normal coronaries are created and static finite element (FE) simulations of increasing aortic root expansions are carried out. Different coronary take-off angles and intramural penetrations are investigated to assess their role on coronary lumen narrowing. Results show that increasing aortic and coronary pressures lead to lumen expansion in normal coronaries, particularly in the proximal tract, while the expansion of the anomalous coronaries is impaired especially at the ostium. Concerning the geometric features of the anomaly, acute take-off angles cause elongated coronary ostia, with an eccentricity increasing with aortic expansion; the impact of the coronary intramural penetration on the lumen narrowing is limited. The present study provides a proof of concept of the biomechanical reasons underlying the lumen narrowing in AAOCA during aortic expansion, promoting the role of computational simulations as a tool to assess the mechanisms of this pathology.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA