Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 185
Filtrar
1.
Artigo em Inglês | MEDLINE | ID: mdl-38750641

RESUMO

BACKGROUND: The liver is the most common organ injured in blunt abdominal trauma and makes up roughly 5% of all trauma admissions. Current treatments are invasive and resource-intensive, which may delay care. We aim to develop and validate a contrast-enhanced ultrasound (CEUS)guided noninvasive tool to treat liver lacerations at the bedside. METHODS: Two 1.8 MHz high-intensity focused ultrasound (HIFU) elements were coupled to a C1-6 diagnostic ultrasound probe and a Logiq E10 scanner (GE HealthCare) utilizing a custom enclosure for co-registered imaging and ablation. A phantom was created from polyacrylamide gel combined with thermochromic ink whose color changes above biological ablative temperatures (60 °C). The HIFU wave was focused approximately 0.5 cm below the surface utilizing a 50% duty cycle generating 11.9 MPa for 20, 30, 40, 50, and 60s. Experiments were repeated on ex vivo chicken livers in a water bath. Finally, the livers of 4 live swine underwent up to 6 CEUS-guided treatments using parameters optimized from in vitro work. RESULTS: Treatment of the phantom between 20-60s, produced ablation sizes from 0.016 to 0.4 cm 3 . The relationship between time and size was exponential (R 2 = 0.992). Ablation areas were also well visualized on with ultrasound imaging. The ex vivo liver ablation size at 20s was 0.37 cm 3 , at 30s was 0.66 cm 3 , and at 100 s was 5.0 cm 3 . For the in-vivo swine experiments, the average ablation area measured 2.0x0.75 cm with a maximum of 3.5x1.5 cm. CEUS was utilized with the contrast agent Definity (Lantheus) for identification of lacerations as well as immediate post operative evaluation of therapy. CONCLUSION: These experiments demonstrate the feasibility of CEUS guided transdermal HIFU ablation and the time-dependent size of ablation. This work warrants future investigations into using ultrasound to detect active bleeding and HIFU to coagulate grade III and IV liver laceration. STUDY TYPE: Therapeutic/care management.

2.
J Acoust Soc Am ; 155(4): 2636-2645, 2024 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-38629883

RESUMO

Subharmonic aided pressure estimation (SHAPE) is a noninvasive pressure measurement technique based on the pressure dependent subharmonic signal from contrast microbubbles. Here, SonoVue microbubble with a sulfur hexafluoride (SF6) core, was investigated for use in SHAPE. The study uses excitations of 25-700 kPa peak negative pressure (PNP) and 3 MHz frequency over eight pressurization cycles between atmospheric pressure and overpressures, ranging from 0 to 25 kPa (0 to 186 mm Hg). The SonoVue subharmonic response was characterized into two types. Unlike other microbubbles, SonoVue showed significant subharmonic signals at low excitations (PNPs, 25-400 kPa), denoted here as type I subharmonic. It linearly decreased with increasing overpressure (-0.52 dB/kPa at 100 kPa PNP). However, over multiple pressurization-depressurization cycles, type I subharmonic changed; its value at atmospheric pressure decreased over multiple cycles, and at later cycles, it recorded an increase in amplitude with overpressure (highest, +13 dB at 50 kPa PNP and 10 kPa overpressure). The subharmonic at higher excitations (PNP > 400 kPa), denoted here as type II subharmonic, showed a consistent decrease with the ambient pressure increase with strongest sensitivity of -0.4 dB/kPa at 500 kPa PNP.

3.
Transl Androl Urol ; 13(2): 342-352, 2024 Feb 29.
Artigo em Inglês | MEDLINE | ID: mdl-38481874

RESUMO

Background and Objective: Erectile dysfunction (ED) is a common condition in men, and many patients refractory to conservative treatment may undergo penile prostheses (PPs) placement. The primary concern following PP implantation is device infection. Although antibiotic and hydrophilic coatings have reduced the incidence of inflatable PP (IPP) infections, there remains room for improvement. Optimization of PP outcomes requires a practical in vivo model to better understand mechanisms of infection and to test new infection control strategies. We aimed to describe a new rabbit model which contains a functional IPP and review previously reported animal PP models. Methods: An IPP was placed into rabbit flanks and cycled for functionality testing. Rabbits were evaluated for signs of pain and distress over 14 days. Separately, narrative review methodology was utilized to search the PubMed and Scopus databases for all publications through March 21, 2023, which studied PP within an in vivo setting. Three independent reviewers ultimately selected 12 papers from 1992-2021 for inclusion. Key Content and Findings: Several animal studies highlighted the initial functionality or feasibility of devices for ED before their introduction in the clinical setting. There are several subsequent studies aimed at optimizing the type of antibiotic use or coating material using segments of PP material in an in vivo setting. However, the literature lacks a contemporary animal model containing a functional IPP. Our novel rabbit model offers a safe, practical way to implant a functioning IPP and investigate new perioperative infection prevention and treatment strategies before trials in the clinical setting. Conclusions: Animal models have played a key role in testing medical devices, including PPs, prior to their clinical introduction. Our review uncovered no modern animal studies involving placement of a functional PP. A new animal model can facilitate study of evolving microorganism profiles, novel methods to enhance antibiotic delivery, and proposed treatment options.

4.
Ultrason Imaging ; 46(2): 130-134, 2024 03.
Artigo em Inglês | MEDLINE | ID: mdl-38318708

RESUMO

Subharmonic aided pressure estimation (SHAPE) is a technique that utilizes subharmonic signals from microbubble contrast agents for pressure estimation. Validation of the SHAPE technique relies on synchronous measurements of in vivo pressures using contrast microbubbles and a pressure catheter (reference standard). For the guidance and placement of pressure catheter in vivo, iodinated contrast is used with fluoroscopy. Therefore, during data acquisition for validation studies of the SHAPE technique, both contrast microbubbles and iodinated contrast are present simultaneously within the vasculature. This study aims to elucidate the effects of iodinated contrast (Visipaque, GE HealthCare) on subharmonic signal amplitude from contrast microbubbles (Definity, Lantheus Medical Imaging, Inc.). In an acrylic water tank, 0.06 mL of Definity and varied amounts of Visipaque (0.14, 0.43, 0.85, and 1.70 mL) were added to 425 mL of deionized water. Ultrasound scanning was performed with a SonixTablet scanner (BK Medical Systems) using optimized parameters for SHAPE with Definity (ftransmit/receive = 3.0/1.5 MHz; chirp down pulse). Subharmonic data was acquired and analyzed at 9 different incident acoustic outputs (n = 3). Results showed an increase in subharmonic signal amplitude from Definity microbubbles in the presence of 0.14 mL Visipaque by 2.8 ± 1.3 dB (p < .001), no change with 0.85 mL Visipaque (0.7 ± 1.2 dB; p = .09) and a decrease in subharmonic amplitude in the presence of 1.70 mL Visipaque by 1.9 ± 0.7 dB (p < .001). While statistically significant effect on subharmonic signal amplitude of Definity microbubbles was noted due to the mixture, the magnitude of the effect was minimal (~2.8 dB) and unlikely to impact in vivo SHAPE measurements.


Assuntos
Meios de Contraste , Fluorocarbonos , Ácidos Tri-Iodobenzoicos , Água , Ultrassonografia/métodos
5.
Radiol Cardiothorac Imaging ; 6(1): e230153, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38358329

RESUMO

Purpose To investigate if the right ventricular (RV) systolic and left ventricular (LV) diastolic pressures can be obtained noninvasively using the subharmonic-aided pressure estimation (SHAPE) technique with Sonazoid microbubbles. Materials and Methods Individuals scheduled for a left and/or right heart catheterization were prospectively enrolled in this institutional review board-approved clinical trial from 2017 to 2020. A standard-of-care catheterization procedure was performed by advancing fluid-filled pressure catheters into the LV and aorta (n = 25) or RV (n = 22), and solid-state high-fidelity pressure catheters into the LV and aorta in a subset of participants (n = 18). Study participants received an infusion of Sonazoid microbubbles (GE HealthCare), and SHAPE data were acquired using a validated interface developed on a SonixTablet (BK Medical) US scanner, synchronously with the pressure catheter data. A conversion factor, derived using cuff-based pressure measurements with a SphygmoCor XCEL PWA (ATCOR) and subharmonic signal from the aorta, was used to convert the subharmonic signal into pressure values. Errors between the pressure measurements obtained using the SHAPE technique and pressure catheter were compared. Results The mean errors in pressure measurements obtained with the SHAPE technique relative to those of the fluid-filled pressure catheter were 1.6 mm Hg ± 1.5 [SD] (P = .85), 8.4 mm Hg ± 6.2 (P = .04), and 7.4 mm Hg ± 5.7 (P = .09) for RV systolic, LV minimum diastolic, and LV end-diastolic pressures, respectively. Relative to the measurements with the solid-state high-fidelity pressure catheter, the mean errors in LV minimum diastolic and LV end-diastolic pressures were 7.2 mm Hg ± 4.5 and 6.8 mm Hg ± 3.3 (P ≥ .44), respectively. Conclusion These results indicate that SHAPE with Sonazoid may have the potential to provide clinically relevant RV systolic and LV diastolic pressures. Keywords: Ultrasound-Contrast, Cardiac, Aorta, Left Ventricle, Right Ventricle ClinicalTrials.gov registration no.: NCT03245255 © RSNA, 2024.


Assuntos
Compostos Férricos , Ferro , Microbolhas , Óxidos , Humanos , Coração , Ventrículos do Coração
7.
Hepatology ; 79(2): 380-391, 2024 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-37548928

RESUMO

BACKGROUND AND AIMS: The objective of this study is to determine the diagnostic accuracy of the American College of Radiology Contrast-Enhanced Ultrasound (CEUS) Liver Imaging Reporting and Data System LR-5 characterization for HCC diagnosis in North American or European patients. APPROACH AND RESULTS: A prospective multinational cohort study was performed from January 2018 through November 2022 at 11 academic and nonacademic centers in North America and Europe. Patients at risk for HCC with at least 1 liver observation not previously treated, identified on ultrasound (US), or multiphase CT or MRI performed as a part of standard clinical care were eligible for the study. All participants were examined with CEUS of the liver within 4 weeks of CT/MRI or tissue diagnosis to characterize up to 2 liver nodules per participant using ACR CEUS Liver Imaging Reporting and Data System. Definite HCC diagnosis on the initial CT/MRI, imaging follow-up, or histology for CT/MRI-indeterminate nodules were used as reference standards. A total of 545 nodules had confirmed reference standards in 480 patients, 73.8% were HCC, 5.5% were other malignancies, and 20.7% were nonmalignant. The specificity of CEUS LR-5 for HCC was 95.1% (95% CI 90.1%-97.7%), sensitivity 62.9% (95% CI 57.9%-67.7%), positive predictive value 97.3% (95% CI 94.5%-98.7%), and negative predictive value 47.7% (95% CI 41.7%-53.8%). In addition, benign CEUS characterization (LR-1 or LR-2) had 100% specificity and 100% positive predictive value for nonmalignant liver nodules. CONCLUSIONS: CEUS Liver Imaging Reporting and Data System provides an accurate categorization of liver nodules in participants at risk for HCC.


Assuntos
Carcinoma Hepatocelular , Neoplasias Hepáticas , Humanos , Carcinoma Hepatocelular/patologia , Neoplasias Hepáticas/patologia , Estudos Prospectivos , Estudos de Coortes , Meios de Contraste , Estudos Retrospectivos , Reprodutibilidade dos Testes , Imageamento por Ressonância Magnética/métodos , Europa (Continente) , América do Norte , Sensibilidade e Especificidade
8.
Ultrasound Med Biol ; 50(3): 394-398, 2024 03.
Artigo em Inglês | MEDLINE | ID: mdl-38123378

RESUMO

OBJECTIVE: The aim of the work described here was to assess uterine fibroid vascularity using contrast-enhanced ultrasound (CEUS) as compared with magnetic resonance imaging (MRI). METHODS: Forty women diagnosed with symptomatic uterine fibroids scheduled for uterine artery embolization (UAE) were enrolled in this institutional review board-approved study. Before UAE, participants underwent CEUS examination with an Aplio i800 scanner (Canon Medical Systems, Tustin, CA, USA) with curvilinear array (8C1). CEUS was performed using 2.0 mL of the ultrasound contrast agent Lumason (Bracco, Milan, Italy) administered intravenously. Digital CEUS clips were acquired and randomized offline, and fibroids were characterized as hyper- or hypovascular. MRI was used as reference standard for fibroid vascularity and compared with CEUS. Results were analyzed using McNemar's test. RESULTS: Forty participants were enrolled in the trial. One patient did not proceed with the UAE procedure and one patient refused pre-procedure MRI because of claustrophobia. Therefore, 38 participants underwent CEUS and MRI examinations before UAE. Hypervascular fibroids were seen on MRI and CEUS in 24 and 26 participants, respectively. Hypovascular fibroids were seen with MRI and CEUS in 14 and 12 participants, respectively. Fibroids characterized as hypovascular in two participants by MRI were characterized as hypervascular by CEUS. CEUS and MRI findings were similar in 36 of 38 participants, corresponding to an accuracy of 95% (p = 0.62). CONCLUSION: Contrast-enhanced ultrasound can accurately assess uterine fibroid vascularity, serving as a potential alternative to MRI in determination of the vascularity of uterine fibroids.


Assuntos
Leiomioma , Neoplasias Uterinas , Feminino , Humanos , Leiomioma/diagnóstico por imagem , Leiomioma/irrigação sanguínea , Imageamento por Ressonância Magnética , Resultado do Tratamento , Ultrassonografia , Neoplasias Uterinas/irrigação sanguínea
9.
Radiology ; 309(1): e230727, 2023 10.
Artigo em Inglês | MEDLINE | ID: mdl-37847138

RESUMO

Background Contrast-enhanced (CE) US has been studied for use in the detection of residual viable hepatocellular carcinoma (HCC) after locoregional therapy, but multicenter data are lacking. Purpose To compare two-dimensional (2D) and three-dimensional (3D) CE US diagnostic performance with that of CE MRI or CT, the current clinical standard, in the detection of residual viable HCC after transarterial chemoembolization (TACE) in a prospective multicenter trial. Materials and Methods Participants aged at least 21 years with US-visible HCC scheduled for TACE were consecutively enrolled at one of three participating academic medical centers from May 2016 to March 2022. Each underwent baseline 2D and 3D CE US before TACE, 2D and 3D CE US 1-2 weeks and/or 4-6 weeks after TACE, and CE MRI or CT 4-6 weeks after TACE. CE US and CE MRI or CT were evaluated by three fellowship-trained radiologists for the presence or absence of viable tumors and were compared with reference standards of pathology (18%), angiography on re-treatment after identification of residual disease at 1-2-month follow-up imaging (31%), 4-8-month CE MRI or CT (42%), or short-term (approximately 1-2 months) CE MRI or CT if clinically decompensated and estimated viability was greater than 50% at imaging (9%). Diagnostic performance criteria, including sensitivity and specificity, were obtained for each modality and time point with generalized estimating equation analysis. Results A total of 132 participants were included (mean age, 64 years ± 7 [SD], 87 male). Sensitivity of 2D CE US 4-6 weeks after TACE was 91% (95% CI: 84, 95), which was higher than that of CE MRI or CT (68%; 95% CI: 58, 76; P < .001). Sensitivity of 3D CE US 4-6 weeks after TACE was 89% (95% CI: 81, 94), which was higher than that of CE MRI or CT (P < .001), with no evidence of a difference from 2D CE US (P = .22). CE MRI or CT had 85% (95% CI: 76, 91) specificity, higher than that of 4-6-week 2D and 3D CE US (70% [95% CI: 56, 80] and 67% [95% CI: 53, 78], respectively; P = .046 and P = .023, respectively). No evidence of differences in any diagnostic criteria were observed between 1-2-week and 4-6-week 2D CE US (P > .21). Conclusion The 2D and 3D CE US examinations 4-6 weeks after TACE revealed higher sensitivity in the detection of residual HCC than CE MRI or CT, albeit with lower specificity. Importantly, CE US performance was independent of follow-up time. Clinical trial registration no. NCT02764801 © RSNA, 2023 Supplemental material is available for this article.


Assuntos
Carcinoma Hepatocelular , Quimioembolização Terapêutica , Neoplasias Hepáticas , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Carcinoma Hepatocelular/diagnóstico por imagem , Carcinoma Hepatocelular/terapia , Quimioembolização Terapêutica/métodos , Meios de Contraste , Neoplasias Hepáticas/diagnóstico por imagem , Neoplasias Hepáticas/terapia , Neoplasias Hepáticas/patologia , Estudos Prospectivos , Resultado do Tratamento , Adulto Jovem , Adulto
10.
Endosc Ultrasound ; 12(4): 362-368, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37795347

RESUMO

Objectives: The objective of this pilot study was to compare the performance of contrast-enhanced EUS (CE-EUS)-guided fine-needle aspiration (FNA) with EUS-FNA for lymph node (LN) staging in esophageal cancer. Methods: Thirty-seven subjects with esophageal cancer undergoing EUS staging were enrolled, and 30 completed this institutional review board-approved study. A Prosound F75 US system (Hitachi Medical Systems, Tokyo, Japan) with harmonic contrast imaging software and GF-UCT180 curvilinear endoscope (Olympus, Tokyo, Japan) was utilized. All LNs identified by standard EUS were first noted. Sonazoid (dose: 1 mL; GE Healthcare, Oslo, Norway) was administered peritumorally, and all enhanced LNs were recorded. Fine-needle aspiration was performed on LNs considered suspicious by EUS alone, as well as LNs enhanced on CE-EUS. Performance of each modality was compared using FNA cytology as reference standard. Results: A total of 132 LNs were detected with EUS, of which 59 showed enhancement on CE-EUS. Fifty-three LNs underwent FNA, and 22 LNs were determined to be malignant. Among the latter, 10 were considered suspicious by EUS, whereas the other 12 LNs underwent FNA only because of CE-EUS enhancement. Contrast-enhanced EUS showed enhancement in 19 of the 22 malignant LNs. The rate of metastatic node identification from EUS was 45% (10/22), and it was 86% (19/22; P = 0.008) for CE-EUS. Eight subjects (8/30 [27% of study total]) had nodal status upgraded by the addition of CE-EUS, which influenced LN staging and clinical management. Conclusions: Fine-needle aspiration of LNs identified by CE-EUS may increase metastasis positive rate by ruling out LNs not associated with the tumor drainage pattern. In addition, CE-EUS seems to identify more metastatic LNs that would not be biopsied under the standard EUS criteria.

11.
J Breast Cancer ; 26(3): 286-291, 2023 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-37272244

RESUMO

Approximately 15%-25% of breast lymphatic drainage passes through the internal thoracic (internal mammary) lymphatic system, draining the inner quadrants of the breast. This study aimed to use lymphosonography to identify sentinel lymph nodes (SLNs) in the axillary and internal thoracic lymphatic systems in patients with breast cancer. Seventy-nine patients received subcutaneous ultrasound contrast agent injections around the tumor. Lymphosonography was used to identify SLNs. In 14 of the 79 patients (17.7%), the tumor was located in the inner quadrant of the breast. Lymphosonography identified 217 SLNs in 79 patients, averaging 2.7 SLNs per patient. The 217 identified SLNs in the 79 patients were located in the axillary lymphatic system; none were located in the internal thoracic (internal mammary) lymphatic system, although it was expected in two to four patients (i.e., 4-11 SLNs). These results implied that SLNs associated with breast cancer are predominantly located in the axillary lymphatic system.

12.
Acad Radiol ; 30 Suppl 2: S211-S219, 2023 09.
Artigo em Inglês | MEDLINE | ID: mdl-37330354

RESUMO

RATIONALE AND OBJECTIVES: To monitor fibroid microvascularity using contrast-enhanced ultrasound (CEUS) and a new high-sensitive Doppler mode (SMI) for assessment of uterine artery embolization (UAE) outcomes. MATERIALS AND METHODS: Forty women with symptomatic uterine fibroids scheduled for UAE were enrolled in this Institutional Review Board-approved study. Subjects underwent three examinations (day 0, 15, and 90 post-UAE) with Color Doppler (CDI), power Doppler (PDI), color and monochrome SMI (cSMI and mSMI), and CEUS imaging of the fibroids. Clips were assessed by two radiologists classifying fibroids based on their vascularity. Fibroid fractional vascularity (FV; % of enhanced pixels within the fibroid) and flow intensity (as mean brightness level of the enhanced pixels) were quantified. Results were analyzed using repeated measures ANOVA and nonparametric Wilcoxon sign rank tests. Inter-reader agreement was assessed with κ-values. RESULTS: There was overall agreement between readers for all imaging modalities and examination times (P = .25; κ = 0.70). The FV analysis showed statistically significant differences between CEUS and the Doppler imaging modes (CDI, PDI, cSMI, and mSMI) for the three examination times were compared (P < .0001). The comparison using CDI, PDI, and cSMI showed no statistically significant difference (P = .53). The flow intensity analysis comparison between the Doppler imaging modes (CDI, PDI, cSMI and mSMI) and examination times showed statistically significant differences between all the Doppler imaging modalities (P = .02), except for the 90days post-UAE (P = .34). When the comparison was made for CDI, PDI, and cSMI there was no statistically significant differences (P < .47). CONCLUSION: CEUS and SMI can accurately evaluate fibroid microvascularity, and therefore, can be a noninvasive and accurate method for monitoring outcomes following UAE treatment.


Assuntos
Leiomioma , Embolização da Artéria Uterina , Neoplasias Uterinas , Humanos , Feminino , Ultrassonografia , Ultrassonografia Doppler/métodos , Leiomioma/diagnóstico por imagem , Leiomioma/terapia , Neoplasias Uterinas/diagnóstico por imagem , Neoplasias Uterinas/terapia , Resultado do Tratamento
13.
J Ultrasound Med ; 42(10): 2357-2368, 2023 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-37249416

RESUMO

OBJECTIVES: Bacterial infection following spinal fusion is a major clinical concern with up to 20% incidence. An ultrasound-triggered bulk-release system to combat postsurgical bacterial survival was designed and evaluated. METHODS: Polylactic acid (PLA) clips were loaded with vancomycin (VAN) and microbubbles (Sonazoid, GE HealthCare) in vitro. Stability was determined over 14 days. VAN-loaded clips were submerged in water and insonated using a Logiq E10 scanner (GE HealthCare) with a curvilinear C6 probe. Doppler-induced VAN release was quantified using spectrophotometry. For in vivo testing, clips were loaded with methylene blue (MeB) solution and Sonazoid. These clips were implanted into a rabbit along the spine at L2 and L5, as well as a pig at L1 and L3, then insonated in Doppler mode using the C6 probe. RESULTS: Sonazoid microbubbles were better preserved when incubated in VAN compared with distilled water at 4°C, 25°C, and 37°C incubation temperatures (P = .0131). Contrast enhancement was observed from both solutions when incubated at 4°C storage conditions. Insonated clips achieved average cumulative VAN release of 101.8 ± 2.8% (81.4 ± 2.8 mg) after 72 hours. Uninsonated clips had only 0.3 ± 0.1% (0.3 ± 0.1 mg) average cumulative VAN release (P < .0001). Clips retrieved from the rabbit did not rupture with insonation nor produce MeB staining of surrounding tissues. In the pig, the PLA film was visibly ruptured and MeB tissue was observed following insonation, whereas the uninsonated clip was intact. CONCLUSION: These results demonstrate ultrasound-triggered release of an encapsulated prophylactic solution and provide an important proof-of-concept for continuing large animal evaluations for translational merit.


Assuntos
Poliésteres , Vancomicina , Animais , Coelhos , Suínos , Ultrassonografia , Água
14.
Pediatr Radiol ; 53(8): 1640-1647, 2023 07.
Artigo em Inglês | MEDLINE | ID: mdl-37062765

RESUMO

BACKGROUND: Intracranial pressure (ICP) monitoring in children currently requires invasive techniques. Subharmonic aided pressure estimation (SHAPE) uses contrast-enhanced ultrasound (CEUS) to measure intravascular and interstitial pressure, but utility in ICP measurements has yet to be explored. OBJECTIVE: The objective of this study was to investigate SHAPE as a novel tool for noninvasive ICP measurements in fetal lambs. MATERIALS AND METHODS: Eighteen fetal lambs at 107-139 days gestational age (term = 145 days) underwent subdural ICP catheter placement. The brain was imaged in the coronal plane in CEUS mode optimized for SHAPE, while infusing an US contrast agent into the fetal circulation. After SHAPE calibration, saline was infused via the subdural catheter to increase ICP. Five-second SHAPE cine clips were obtained at various ICPs. Subharmonic intensity values of the whole brain and thalami were correlated with ICP values using mixed effects linear regression analyses and the strength of the relationship was evaluated by Spearman's rank-order correlation. RESULTS: Forty-nine experiments produced 723 datapoints, including SHAPE intensity values and mean ICP measurements. There was a statistically significant inverse relationship between SHAPE intensity values and ICP measurements in the whole brain and thalami (median rho value - 0.58 and - 0.56, respectively). CONCLUSION: SHAPE intensity values of the brain demonstrate an inverse and statistically significant correlation with in vivo ICP measurements in an animal model.


Assuntos
Meios de Contraste , Pressão Intracraniana , Animais , Ovinos , Humanos , Ultrassonografia/métodos , Encéfalo/diagnóstico por imagem
15.
Commun Biol ; 6(1): 425, 2023 04 17.
Artigo em Inglês | MEDLINE | ID: mdl-37069337

RESUMO

Treatment failure in joint infections is associated with fibrinous, antibiotic-resistant, floating and tissue-associated Staphylococcus aureus aggregates formed in synovial fluid (SynF). We explore whether antibiotic activity could be increased against Staphylococcus aureus aggregates using ultrasound-triggered microbubble destruction (UTMD), in vitro and in a porcine model of septic arthritis. In vitro, when bacterially laden SynF is diluted, akin to the dilution achieved clinically with lavage and local injection of antibiotics, amikacin and ultrasound application result in increased bacterial metabolism, aggregate permeabilization, and a 4-5 log decrease in colony forming units, independent of microbubble destruction. Without SynF dilution, amikacin + UTMD does not increase antibiotic activity. Importantly, in the porcine model of septic arthritis, no bacteria are recovered from the SynF after treatment with amikacin and UTMD-ultrasound without UTMD is insufficient. Our data suggest that UTMD + antibiotics may serve as an important adjunct for the treatment of septic arthritis.


Assuntos
Artrite Infecciosa , Infecções Estafilocócicas , Animais , Suínos , Staphylococcus aureus , Amicacina/farmacologia , Microbolhas , Artrite Infecciosa/tratamento farmacológico , Infecções Estafilocócicas/tratamento farmacológico , Infecções Estafilocócicas/microbiologia , Antibacterianos/farmacologia
16.
Pharmaceutics ; 15(4)2023 Apr 21.
Artigo em Inglês | MEDLINE | ID: mdl-37111787

RESUMO

Tumor hypoxia (oxygen deficiency) is a major contributor to radiotherapy resistance. Ultrasound-sensitive microbubbles containing oxygen have been explored as a mechanism for overcoming tumor hypoxia locally prior to radiotherapy. Previously, our group demonstrated the ability to encapsulate and deliver a pharmacological inhibitor of tumor mitochondrial respiration (lonidamine (LND)), which resulted in ultrasound-sensitive microbubbles loaded with O2 and LND providing prolonged oxygenation relative to oxygenated microbubbles alone. This follow-up study aimed to evaluate the therapeutic response to radiation following the administration of oxygen microbubbles combined with tumor mitochondrial respiration inhibitors in a head and neck squamous cell carcinoma (HNSCC) tumor model. The influences of different radiation dose rates and treatment combinations were also explored. The results demonstrated that the co-delivery of O2 and LND successfully sensitized HNSCC tumors to radiation, and this was also enhanced with oral metformin, significantly slowing tumor growth relative to unsensitized controls (p < 0.01). Microbubble sensitization was also shown to improve overall animal survival. Importantly, effects were found to be radiation dose-rate-dependent, reflecting the transient nature of tumor oxygenation.

17.
Ultrasound Med Biol ; 49(7): 1550-1560, 2023 07.
Artigo em Inglês | MEDLINE | ID: mdl-37100673

RESUMO

OBJECTIVE: The sensitivity of the acoustic response of microbubbles, specifically a strong correlation between their subharmonic response and the ambient pressure, has motivated development of a non-invasive subharmonic-aided pressure estimation (SHAPE) method. However, this correlation has previously been found to vary depending on the microbubble type, the acoustic excitation and the hydrostatic pressure range. In this study, the ambient pressure sensitivity of microbubble response was investigated. METHODS: The fundamental, subharmonic, second harmonic and ultraharmonic responses from an in-house lipid-coated microbubble were measured for excitations with peak negative pressures (PNPs) of 50-700 kPa and frequencies of 2, 3 and 4 MHz in the ambient overpressure range 0-25 kPa (0-187 mmHg) in an in vitro setup. RESULTS: The subharmonic response typically has three stages-occurrence, growth and saturation-with increasing excitation PNP. We find distinct decreasing and increasing variations of the subharmonic signal with overpressure that are closely related to the threshold of subharmonic generation in a lipid-shelled microbubble. Above the excitation threshold, that is, in the growth-saturation phase, subharmonic signals decreased linearly with slopes as high as -0.56 dB/kPa with ambient pressure increase; below the threshold excitation (at atmospheric pressure), increasing overpressure triggers subharmonic generation, indicating a lowering of subharmonic threshold, and therefore leads to an increase in subharmonic with overpressure, the maximum enhancement being ∼11 dB for 15 kPa overpressure at 2 MHz and 100 kPa PNP. CONCLUSION: This study indicates the possible development of novel and improved SHAPE methodologies.


Assuntos
Meios de Contraste , Microbolhas , Acústica , Pressão , Lipídeos , Ultrassonografia/métodos
18.
Ultrasound Q ; 39(2): 100-108, 2023 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-36943721

RESUMO

ABSTRACT: This study investigated the correlation between magnetic resonance elastography (MRE) and shear wave ultrasound elastography (SWE) in patients with clinically diagnosed or suspected nonalcoholic fatty liver disease (NAFLD). Subjects with or at risk of NAFLD identified by magnetic resonance imaging (MRI) proton density fat fraction (PDFF) were prospectively enrolled. For each patient, 6 valid 2-dimensional SWE measurements were acquired using a Logiq E10 scanner (GE HealthCare, Waukesha, WI). A reliability criterion of an interquartile range to median ratio of ≤15% was used for SWE to indicate quality dataset. Magnetic resonance elastography, and MR-fat quantification data were collected the same day as part of the patient's clinical standard of care. Magnetic resonance imaging PDFF was used as a reference to quantify fat with >6.4% indicating NAFLD. Pearson correlation and t-test were performed for statistical analyses. A total of 140 patients were enrolled, 112 of which met SWE reliability measurement criteria. Magnetic resonance elastography and 2-dimensional SWE showed a positive correlation across all study subjects ( r = 0.27; P = 0.004). When patients were grouped according to steatosis and fibrosis state, a positive correlation was observed between MRE and SWE in patients with fibrosis ( r = 0.30; P = 0.03), without fibrosis ( r = 0.27; P = 0.03), and with NAFLD ( r = 0.28; P = 0.02). No elastography technique correlated with liver fat quantification ( P > 0.52). Magnetic resonance elastography was significantly different between patients with and without fibrosis ( P < 0.0001). However, this difference was not apparent with SWE ( P = 0.09). In patients with suspected or known NAFLD, MRE, and SWE demonstrated a positive correlation. In addition, these noninvasive imaging modalities may be useful adjunct techniques for monitoring NAFLD.


Assuntos
Técnicas de Imagem por Elasticidade , Hepatopatia Gordurosa não Alcoólica , Humanos , Hepatopatia Gordurosa não Alcoólica/diagnóstico por imagem , Hepatopatia Gordurosa não Alcoólica/patologia , Técnicas de Imagem por Elasticidade/métodos , Cirrose Hepática/patologia , Reprodutibilidade dos Testes , Fígado/diagnóstico por imagem , Fígado/patologia , Imageamento por Ressonância Magnética/métodos , Espectroscopia de Ressonância Magnética
19.
RMD Open ; 9(1)2023 02.
Artigo em Inglês | MEDLINE | ID: mdl-36787926

RESUMO

OBJECTIVE: To assess the finger vascularity of systemic sclerosis patients with Raynaud's phenomenon (RP-SSc) using various ultrasound techniques. METHODS: All fingers (except thumbs) of 18 RP-SSc patients and 18 controls were imaged at room temperature using four ultrasound vascular imaging techniques. The percent vascular area was quantified by counting blood flow pixels in a 25 mm2 square centred at the nail fold for the dorsal side and in 25 mm2 and 100 mm2 square from the fingertip for the ventral side. The mean vascular intensity was calculated from the corresponding areas for dorsal and ventral sides. RESULTS: The percent vascular areas and mean vascular intensities in RP-SSc were significantly lower than those in controls for both dorsal and ventral sides (p<0.01). The mean vascular intensities showed slightly higher area under the curve (AUC) than the percent vascular areas (0.53-0.91 vs 0.53-0.90) regardless of imaging technique and assessment side. For each imaging technique, the ventral side vascularity showed a higher AUC (0.74-0.91) compared with the dorsal side (0.53-0.81). Moreover, ventral side abnormalities were associated with a history of digital ulcers. CONCLUSIONS: Ultrasound demonstrated potential to quantify finger vascularity of RP-SSc. The ventral side of the fingers showed a higher accuracy in detecting RP-SSc than the dorsal side.


Assuntos
Escleroderma Sistêmico , Humanos , Escleroderma Sistêmico/diagnóstico , Escleroderma Sistêmico/diagnóstico por imagem , Dedos
20.
J Ultrasound Med ; 42(8): 1747-1756, 2023 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-36807314

RESUMO

OBJECTIVES: Current diagnosis of nonalcoholic fatty liver disease (NAFLD) relies on biopsy or MR-based fat quantification. This prospective study explored the use of ultrasound with artificial intelligence for the detection of NAFLD. METHODS: One hundred and twenty subjects with clinical suspicion of NAFLD and 10 healthy volunteers consented to participate in this institutional review board-approved study. Subjects were categorized as NAFLD and non-NAFLD according to MR proton density fat fraction (PDFF) findings. Ultrasound images from 10 different locations in the right and left hepatic lobes were collected following a standard protocol. MRI-based liver fat quantification was used as the reference standard with >6.4% indicative of NAFLD. A supervised machine learning model was developed for assessment of NAFLD. To validate model performance, a balanced testing dataset of 24 subjects was used. Sensitivity, specificity, positive predictive value, negative predictive value, and overall accuracy with 95% confidence interval were calculated. RESULTS: A total of 1119 images from 106 participants was used for model development. The internal evaluation achieved an average precision of 0.941, recall of 88.2%, and precision of 89.0%. In the testing set AutoML achieved a sensitivity of 72.2% (63.1%-80.1%), specificity of 94.6% (88.7%-98.0%), positive predictive value (PPV) of 93.1% (86.0%-96.7%), negative predictive value of 77.3% (71.6%-82.1%), and accuracy of 83.4% (77.9%-88.0%). The average agreement for an individual subject was 92%. CONCLUSIONS: An ultrasound-based machine learning model for identification of NAFLD showed high specificity and PPV in this prospective trial. This approach may in the future be used as an inexpensive and noninvasive screening tool for identifying NAFLD in high-risk patients.


Assuntos
Hepatopatia Gordurosa não Alcoólica , Humanos , Hepatopatia Gordurosa não Alcoólica/diagnóstico por imagem , Hepatopatia Gordurosa não Alcoólica/patologia , Estudos Prospectivos , Inteligência Artificial , Fígado/diagnóstico por imagem , Fígado/patologia , Imageamento por Ressonância Magnética/métodos , Aprendizado de Máquina
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA