Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
1.
Bioengineering (Basel) ; 10(9)2023 Sep 08.
Artigo em Inglês | MEDLINE | ID: mdl-37760163

RESUMO

Finite element analysis is used in this study to investigate the effect of media inhomogeneity on the electric field distribution in a sample composed of cells and their extracellular matrix. The sample is supposed to be subjected to very high pulsed electric field. Numerically computed electric field distribution and transmembrane potential at the cell membrane in electroporation conditions are considered in order to study cell behavior at different degrees of inhomogeneity. The different inhomogeneity grade is locally obtained using a representative model of fixed volume with cell-cell distance varying in the range of 1-283 um. The conductivity of the extracellular medium was varied between plain collagen and a gel-like myxoid matrix through combinations of the two, i.e., collagen and myxoid. An increase in the transmembrane potential was shown in the case of higher aggregate. The results obtained in this study show the effect of the presence of the cell aggregates and collagen on the transmembrane potential. In particular, by increasing the cell aggregation in the two cases, the transmembrane potential increased. Finally, the simulation results were compared to experimental data obtained by culturing HCC1954 cells in a hyaluronic acid-based scaffold. The experimental validation confirmed the behavior of the transmembrane potential in presence of the collagen: an increase in electroporation at a lower electric field intensity was found for the cells cultured in the scaffolds where there is the formation of collagen areas.

2.
Materials (Basel) ; 12(12)2019 Jun 13.
Artigo em Inglês | MEDLINE | ID: mdl-31200532

RESUMO

Since the late 1950s, an effect of electrical current in addition to joule heating on the deformation of metals called the Electroplastic Effect (EPE) has been known. It is used nowadays in the so-called Electrically Assisted Forming (EAF) processes, but the understanding of the phenomenon is not very clear yet. It has been found that EPE increases the formability of high stacking fault energy (SFE) materials, while low SFE materials reach fracture prematurely. Since Duplex Stainless Steels (DSSs) possess a microstructure consisting of two phases with very different SFE (low SFE austenite and high SFE ferrite) and they are widely used in industry, we investigated EPE on those alloys. Tensile tests at 5 A/mm2, 10 A/mm2 and 15 A/mm2 current densities along with thermal counterparts were conducted on UNS S32101, UNS S32205, UNS S32304 and UNS S32750. The DSS grades were characterized by means of optical microscopy, X-ray diffraction and their mechanical properties (ultimate tensile strength, total elongation, uniform elongation and yield stress). An increase in uniform elongation for the electrical tests compared to the thermal counterparts as well as an increase in total elongation was found. No differences were observed on the yield stress and on the ultimate tensile strength. Un uneven distribution of the current because of the different resistivity and work hardening of the two phases has been hypothesized as the explanation for the positive effect of EPE.

3.
Technol Cancer Res Treat ; 17: 1533033818789693, 2018 01 01.
Artigo em Inglês | MEDLINE | ID: mdl-30045667

RESUMO

Electrochemotherapy is an established treatment option for patients with superficially metastatic tumors, mainly malignant melanoma and breast cancer. Based on preliminary experiences, electrochemotherapy has the potential to be translated in the treatment of larger and deeper neoplasms, such as soft tissue sarcomas. However, soft tissue sarcomas are characterized by tissue inhomogeneity and, consequently, by variable electrical characteristic of tumor tissue. The inhomogeneity in conductivity represents the cause of local variations in the electric field intensity. Crucially, this fact may hamper the achievement of the electroporation threshold during the electrochemotherapy procedure. In order to evaluate the effect of tissue inhomogeneity on the electric field distribution, we first performed ex vivo analysis of some clinical cases to quantify the inhomogeneity area. Subsequently, we performed some simulations where the electric field intensity was evaluated by means of finite element analysis. The results of the simulation models are finally compared to an experimental model based on potato and tissue mimic materials. Tissue mimic materials are materials where the conductivity can be suitably designed. The coupling of computation and experimental results could be helpful to show the effect of the inhomogeneity in terms of variation in electric field distribution and characteristics.


Assuntos
Sarcoma/patologia , Simulação por Computador , Condutividade Elétrica , Eletroquimioterapia/métodos , Eletroporação/métodos , Análise de Elementos Finitos , Humanos , Modelos Teóricos
4.
Technol Cancer Res Treat ; 17: 1533033818764498, 2018 01 01.
Artigo em Inglês | MEDLINE | ID: mdl-29558871

RESUMO

Electrochemotherapy is an emerging local treatment for the management of superficial tumors and, among these, also chest wall recurrences from breast cancer. Generally, the treatment of this peculiar type of tumor requires the coverage of large skin areas. In these cases, electrochemotherapy treatment by means of standard small size needle electrodes (an array of 0.73 cm spaced needles, which covers an area of 1.5 cm2) is time-consuming and can allow an inhomogeneous coverage of the target area. We have previously designed grid devices suitable for treating an area ranging from 12 to 200 cm2. In this study, we propose different approaches to study advantages and drawbacks of a grid device with needles positioned 2 cm apart. The described approach includes a numerical evaluation to estimate electric field intensity, followed by an experimental quantification of electroporation on a cell culture. The electric field generated in a conductive medium has been studied by means of 3-dimensional numerical models with varying needle pair distance from 1 to 2 cm. In particular, the electric field evaluation shows that the electric field intensity with varying needle distance is comparable in the area in the middle of the 2 electrodes. Differently, near needles, the electric field intensity increases with the increasing electrode distance and supply voltage. The computational results have been correlated with experimental ones obtained in vitro on cell culture. In particular, electroporation effect has been assessed on human breast cancer cell line MCF7, cultured in monolayer. The use of 2-cm distant needles, supplied by 2000 V, produced an electroporation effect in the whole area comprised between the electrodes. Areas of cell culture where reversible and irreversible electroporation occurred were identified under microscope by using fluorescent dyes. The coupling of computation and experimental results could be helpful to evaluate the effect of the needle distance on the electric field intensity in cell cultures in terms of reversible or irreversible electroporation.


Assuntos
Eletroquimioterapia/métodos , Eletrodos , Modelos Teóricos , Neoplasias/tratamento farmacológico , Análise de Elementos Finitos , Humanos
5.
Nanomaterials (Basel) ; 7(11)2017 Nov 05.
Artigo em Inglês | MEDLINE | ID: mdl-29113079

RESUMO

Ferrofluids are nanomaterials consisting of magnetic nanoparticles that are dispersed in a carrier fluid. Their physical properties, and hence their field of application are determined by intertwined compositional, structural, and magnetic characteristics, including interparticle magnetic interactions. Magnetic nanoparticles were prepared by thermal decomposition of iron(III) chloride hexahydrate (FeCl3·6H2O) in 2-pyrrolidone, and were then dispersed in two different fluids, water and polyethylene glycol 400 (PEG). A number of experimental techniques (especially, transmission electron microscopy, Mössbauer spectroscopy and superconducting quantum interference device (SQUID) magnetometry) were employed to study both the as-prepared nanoparticles and the ferrofluids. We show that, with the adopted synthesis parameters of temperature and FeCl3 relative concentration, nanoparticles are obtained that mainly consist of maghemite and present a high degree of structural disorder and strong spin canting, resulting in a low saturation magnetization (~45 emu/g). A remarkable feature is that the nanoparticles, ultimately due to the presence of 2-pyrrolidone at their surface, are arranged in nanoflower-shape structures, which are substantially stable in water and tend to disaggregate in PEG. The different arrangement of the nanoparticles in the two fluids implies a different strength of dipolar magnetic interactions, as revealed by the analysis of their magnetothermal behavior. The comparison between the magnetic heating capacities of the two ferrofluids demonstrates the possibility of tailoring the performances of the produced nanoparticles by exploiting the interplay with the carrier fluid.

6.
Nanotechnology ; 27(28): 285104, 2016 Jul 15.
Artigo em Inglês | MEDLINE | ID: mdl-27265726

RESUMO

Magnetic iron oxide nanoparticles (Fe-NPs) can be exploited in biomedicine as agents for magnetic fluid hyperthermia (MFH) treatments and as contrast enhancers in magnetic resonance imaging. New, oleate-covered, iron oxide particles have been prepared either by co-precipitation or thermal decomposition methods and incorporated into poly(lactic-co-glycolic acid) nanoparticles (PLGA-Fe-NPs) to improve their biocompatibility and in vivo stability. Moreover, the PLGA-Fe-NPs have been loaded with paclitaxel to pursue an MFH-triggered drug release. Remarkably, it has been found that the nanoparticle formulations are characterized by peculiar (1)H nuclear magnetic relaxation dispersion (NMRD) profiles that directly correlate with their heating potential when exposed to an alternating magnetic field. By prolonging the magnetic field exposure to 30 min, a significant drug release was observed for PLGA-Fe-NPs in the case of the larger-sized magnetic nanoparticles. Furthermore, the immobilization of lipophilic Fe-NPs in PLGA-NPs also made it possible to maintain Néel relaxation as the dominant relaxation contribution in the presence of large iron oxide cores (diameters of 15-20 nm), with the advantage of preserving their efficiency when they are entrapped in the intracellular environment. The results reported herein show that NMRD profiles are a useful tool for anticipating the heating capabilities of Fe-NPs designed for MFH applications.

7.
Radiol Oncol ; 50(1): 49-57, 2016 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-27069449

RESUMO

BACKGROUND: In recent years, superficial chest wall recurrence from breast cancer can be effectively treated by means of electrochemotherapy, with the majority of patients achieving response to treatment. Nevertheless, tumor spread along superficial lymphatic vessels makes this peculiar type of tumor recurrence prone to involve large skin areas and difficult to treat. In these cases, electroporation with standard, small size needle electrodes can be time-consuming and produce an inhomogeneous coverage of the target area, ultimately resulting in patient under treatment. MATERIALS AND METHODS: Authors designed and developed a prototype of a flexible grid electrode aimed at the treatment of large skin surfaces and manufactured a connection box to link the pulse applicator to a voltage pulse generator. Laboratory tests on potato tissue were performed in order to evaluate the electroporation effect, which was evaluated by observing color change of treated tissue. RESULTS: A device has been designed in order to treat chest wall recurrences from breast cancer. According to preliminary tests, the new flexible support of the electrode allows the adaptability to the surface to be treated. Moreover, the designed devices can be useful to treat a larger surface in 2-5 minutes. CONCLUSIONS: Authors developed the prototype of a new pulse applicator aimed at the treatment of widespread superficial tumors. This flexible grid needle electrode was successfully tested on potato tissue and produced an electroporation effect. From a clinical point of view, the development of this device may shorten electrochemotherapy procedure thus allowing clinicians to administer electric pulses at the time of maximum tumor exposure to drugs. Moreover, since the treatment time is 2-5 min long, it could also reduce the time of anesthesia, thus improving patient recovery.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA