Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
2.
Theriogenology ; 156: 171-180, 2020 Oct 15.
Artigo em Inglês | MEDLINE | ID: mdl-32755716

RESUMO

The objectives of the present study were to: 1) compare the reproductive efficiency of embryo transfer (ET) recipients after synchronization of estrus or a 5-day synchronization of ovulation protocol for fixed time ET (FTET), and 2) determine the effect of reutilization of intravaginal P4 devices (CIDRs), up to four times, in a 5-day FTET protocol. In Experiment 1, 817 dairy heifers were assigned to one of three groups: PGF + estrus detection, 5-d FTET protocol with new (1.38 g P4) or 2nd use CIDR (previously used once for 5 d). Fresh in vitro produced embryos were transferred 7 ± 1 day after estrus (PGF + estrus) or GnRH (5-day FTET). Utilization rate (transferred/treated) was greater (P < 0.001) in heifers submitted to FTET compared to ET after estrus, however pregnancies per ET (P/ET) were not different (P > 0.10). As a result, pregnancy per treated (P/treated) recipient was greater (P < 0.05) in heifers in the 5-day FTET protocol. In Experiment 2, 40 dairy heifers without a corpus luteum (CL) were randomly allocated into one of four groups using new, 2nd use, 3rd use (previously used twice for 5 d/each), or 4th use (previously used thrice for 5 d/each) CIDRs. Circulating P4 was reduced (P < 0.01) with each reutilization. In Experiment 3, ovarian follicular dynamics were evaluated in 238 dairy heifers submitted to a 5-day protocol with either new, 2nd use, 3rd use or 4th use CIDRs at random stages of the estrous cycle. Prostaglandin F2α (PGF) was administered at CIDR removal and again 24 h later. Ovulation was induced by GnRH treatment 72 h after CIDR removal. Preovulatory follicle diameter increased (P < 0.001) progressively with increasing CIDR reutilization. Ovulation rate did not differ between treatments, however, interval from CIDR removal to ovulation decreased (P < 0.001) in heifers receiving 3rd and 4th use CIDRs compared to new or 2nd use. Finally, in Experiments 4 and 5, 1203 heifers submitted to a 5-day FTET protocol were randomly assigned to receive either a new CIDR, a 3rd use CIDR (Experiment 4) or a 4th use CIDR (Experiment 5). Despite the increase in CL volume on D5 in heifers treated with 3rd use (P = 0.03) or 4th use CIDRs (P < 0.01), there were no differences (P > 0.05) in utilization rate, P/ET, or P/treated. Thus, use of a 5-day FTET synchronization protocol improves reproductive efficiency by increasing recipient utilization, and reutilization of CIDRs up to four times in recipient dairy heifers does not compromise reproductive performance.


Assuntos
Sincronização do Estro , Progesterona , Animais , Bovinos , Ensaios Clínicos Veterinários como Assunto , Corpo Lúteo , Dinoprosta/farmacologia , Transferência Embrionária/veterinária , Feminino , Hormônio Liberador de Gonadotropina , Inseminação Artificial/veterinária , Ovulação , Gravidez
3.
Theriogenology ; 76(3): 427-35, 2011 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-21497392

RESUMO

The objective was to evaluate the effects of timing of insemination and type of semen in cattle subjected to timed artificial insemination (TAI). In Experiment 1, 420 cyclic Jersey heifers were bred at either 54 or 60 h after P4-device removal, using either sex-sorted (2.1 × 10(6) sperm/straw) or non-sorted sperm (20 × 10(6) sperm/straw) from three sires (2 × 2 factorial design). There was an interaction (P = 0.06) between time of AI and type of semen on pregnancy per AI (P/AI, at 30 to 42 d after TAI); it was greater when sex-sorted sperm (P < 0.01) was used at 60 h (31.4%; 32/102) than at 54 h (16.2%; 17/105). In contrast, altering the timing of AI did not affect conception results with non-sorted sperm (54 h = 50.5%; 51/101 versus 60 h = 51.8%; 58/112; P = 0.95). There was an effect of sire (P < 0.01) on P/AI, but no interaction between sire and time of AI (P = 0.88). In Experiment 2, 389 suckled Bos indicus beef cows were enrolled in the same treatment groups used in Experiment 1. Sex-sorted sperm resulted in lower P/AI (41.8%; 82/196; P = 0.05) than non-sorted sperm (51.8%; 100/193). In addition, there was a tendency for greater P/AI (P = 0.11) when TAI was performed 60 h (50.8%; 99/195) versus 54 h (42.8%; 83/194) after removing the progestin implant. In Experiment 3, 339 suckled B. indicus cows were randomly assigned to receive TAI with sex-sorted sperm at 36, 48, or 60 h after P4 device removal. Ultrasonographic examinations were performed twice daily in all cows to confirm ovulation. On average, ovulation occurred 71.8 ± 7.8 h after P4 removal, and greater P/AI was achieved when insemination was performed closer to ovulation. The P/AI was greatest (37.9%) for TAI performed between 0 and 12 h before ovulation, whereas P/AI was significantly less for TAI performed between 12.1 and 24 h (19.4%) or >24 h (5.8%) before ovulation. In conclusion, sex-sorted sperm resulted in a lesser P/AI than non-sorted sperm following TAI. However, improvements in P/AI with delayed time of AI were possible (Experiments 1 and 3), and seemed achievable when breeding at 60 h following progestin implant removal, compared to the standard 54 h normally used in TAI protocols.


Assuntos
Bovinos/fisiologia , Inseminação Artificial/veterinária , Animais , Cruzamento/métodos , Feminino , Fertilidade , Inseminação Artificial/métodos , Masculino , Gravidez , Taxa de Gravidez , Progesterona/farmacologia , Análise para Determinação do Sexo , Razão de Masculinidade , Fatores de Tempo
4.
Theriogenology ; 74(9): 1636-42, 2010 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-20833421

RESUMO

The objective was to improve pregnancy per artificial insemination (P/AI; 35-42 d after AI) in virgin Jersey heifers bred by AI of sex-sorted semen after being detected in estrus. Giving 100 µg of GnRH at first detection of estrus, with AI 12 h later, did not affect P/AI in Experiment I [GnRH = 47.2% (100/212) vs. No GnRH = 51.7% (104/201); P = 0.38] or Experiment II [GnRH = 53.1% (137/258) vs. No GnRH = 48.6% (122/251); P = 0.43]. In these two experiments, estrus detection was done with tail-head chalk or a HeatWatch(®) system, respectively. In Experiment III, a single insemination dose (2.1 × 106 sperm) 12 h after estrus detection (n = 193), a double dose at 12 h (n = 193), or a double dose involving insemination 12 and 24 h after estrus detection (n = 190) did not affect P/AI (87/193 = 45.1%, 85/193 = 44.0%, and 94/190 = 49.5%, respectively; P = 0.51). However, P/AI was influenced by the number of AI service (First, 115/208 = 55.3%(a); Second, 94/204 = 46.1%(a); and Third, 57/165 = 34.8%(b); P = 0.004). In Experiment IV, the P/AI of heifers inseminated from 12 to 16 h after the onset of estrus (40/106 = 37.7%) was less (P = 0.03) than those inseminated from 16.1 to 20 h (85/164 = 51.8%), and 20.1 to 24 h (130/234 = 55.6%). However, the P/AI for heifers inseminated from 24.1 to 30 h (61/134 = 45.5%) did not differ from that of any other interval. In conclusion, in Jersey heifers inseminated with sex-sorted semen, P/AI was not significantly affected by giving GnRH at detection of estrus or a double insemination dose, but it was higher with AI 16.1 to 24 h vs. 12 to 16 h after the onset of estrus.


Assuntos
Bovinos , Inseminação Artificial/veterinária , Sêmen/citologia , Animais , Estro , Detecção do Estro/métodos , Feminino , Citometria de Fluxo , Hormônio Liberador de Gonadotropina/farmacologia , Inseminação Artificial/métodos , Gravidez , Taxa de Gravidez , Análise para Determinação do Sexo , Fatores de Tempo
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA