Assuntos
Neoplasias Colorretais , Neoplasias Hepáticas , Humanos , Infusões Intra-Arteriais , Neoplasias Hepáticas/tratamento farmacológico , Neoplasias Hepáticas/secundário , Neoplasias Colorretais/tratamento farmacológico , Neoplasias Colorretais/patologia , Artéria Hepática/patologia , Protocolos de Quimioterapia Combinada Antineoplásica/uso terapêutico , FluoruracilaRESUMO
The integrin αvß6, an epithelium-specific cell surface receptor, is overexpressed on numerous malignancies, including the highly lethal pancreatic ductal adenocarcinomas. Here, we developed and tested a novel αvß6-targeting peptide, DOTA-5G (1) radiolabeled with 68Ga, for PET/CT imaging and 177Lu for treatment. With the goal to develop a radiotheranostic, further modifications were made for increased circulation time, renal recycling, and tumor uptake, yielding DOTA-albumin-binding moiety-5G (2). Methods: Peptides 1 and 2 were synthesized on solid phase, and their affinity for αvß6 was assessed by enzyme-linked immunosorbent assay. The peptides were radiolabeled with 68Ga and 177Lu. In vitro cell binding, internalization, and efflux of 68Ga-1 and 177Lu-2 were evaluated in αvß6-positive BxPC-3 human pancreatic cancer cells. PET/CT imaging of 68Ga-1 and 68Ga-2 was performed on female nu/nu mice bearing subcutaneous BxPC-3 tumors. Biodistribution was performed for 68Ga-1 (1 and 2 h after injection), 68Ga-2 (2 and 4 h after injection), and 177Lu-1 and 177Lu-2 (1, 24, 48, and 72 h after injection). The 177Lu-2 biodistribution data were extrapolated for human dosimetry data estimates using OLINDA/EXM 1.1. Therapeutic efficacy of 177Lu-2 was evaluated in mice bearing BxPC-3 tumors. Results: Peptides 1 and 2 demonstrated high affinity (<55 nM) for αvß6 by enzyme-linked immunosorbent assay. 68Ga-1, 68Ga-2, 177Lu-1, and 177Lu-2 were synthesized in high radiochemical purity. Rapid in vitro binding and internalization of 68Ga-1 and 177Lu-2 were observed in BxPC-3 cells. PET/CT imaging and biodistribution studies demonstrated uptake in BxPC-3 tumors. Introduction of the albumin-binding moiety in 177Lu-2 resulted in a 5-fold increase in tumor uptake and retention over time. Based on the extended dosimetry data, the dose-limiting organ for 177Lu-2 is the kidney. Treatment with 177Lu-2 prolonged median survival by 1.5- to 2-fold versus controls. Conclusion: 68Ga-1 and 177Lu-2 demonstrated high affinity for the integrin αvß6 both in vitro and in vivo, were rapidly internalized into BxPC-3 cells, and were stable in mouse and human serum. Both radiotracers showed favorable pharmacokinetics in preclinical studies, with predominantly renal excretion and good tumor-to-normal-tissue ratios. Favorable human dosimetry data suggest the potential of 177Lu-2 as a treatment for pancreatic ductal adenocarcinoma.
Assuntos
Radioisótopos de Gálio , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Feminino , Humanos , Animais , Camundongos , Radioisótopos de Gálio/farmacocinética , Distribuição Tecidual , Linhagem Celular Tumoral , Peptídeos , Albuminas , Neoplasias PancreáticasRESUMO
Myocardial blood flow (MBF) and flow reserve are usually quantified in the clinic with positron emission tomography (PET) using a perfusion-specific radiotracer (e.g.82Rb-chloride). However, the clinical accessibility of existing perfusion tracers remains limited. Meanwhile,18F-fluorodeoxyglucose (FDG) is a commonly used radiotracer for PET metabolic imaging without similar limitations. In this paper, we explore the potential of18F-FDG for myocardial perfusion imaging by comparing the myocardial FDG delivery rateK1with MBF as determined by dynamic82Rb PET in fourteen human subjects with heart disease. Two sets of FDGK1were derived from one-hour dynamic FDG scans. One was the original FDGK1estimates and the other was the correspondingK1values that were linearly normalized for blood glucose levels. A generalized Renkin-Crone model was used to fit FDGK1with Rb MBF, which then allowed for a nonlinear extraction fraction correction for converting FDGK1to MBF. The linear correlation between FDG-derived MBF and Rb MBF was moderate (r= 0.79) before the glucose normalization and became much improved (r> 0.9) after glucose normalization. The extraction fraction of FDG was also similar to that of Rb-chloride in the myocardium. The results from this pilot study suggest that dynamic cardiac FDG-PET with tracer kinetic modeling has the potential to provide MBF in addition to its conventional use for metabolic imaging.
Assuntos
Fluordesoxiglucose F18 , Imagem de Perfusão do Miocárdio , Circulação Coronária , Humanos , Projetos Piloto , Tomografia por Emissão de Pósitrons , Radioisótopos de Rubídio , Tomografia Computadorizada por Raios XRESUMO
The true impact and long-term damage to organs such as the lungs after severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) infection remain to be determined. Noninvasive molecularly targeted imaging may play a critical role in aiding visualization and understanding of the systemic damage. We have identified αvß6 as a molecular target; an epithelium-specific cell surface receptor that is low or undetectable in healthy adult epithelium but upregulated in select injured tissues, including fibrotic lung. Herein we report the first human PET/CT images using the integrin αvß6-binding peptide (18F-αvß6-BP) in a patient 2 mo after the acute phase of infection. Minimal uptake of 18F-αvß6-BP was noted in normal lung parenchyma, with uptake being elevated in areas corresponding to opacities on CT. This case suggests that 18F-αvß6-BP PET/CT is a promising noninvasive approach to identify the presence and potentially monitor the persistence and progression of lung damage.
Assuntos
Antígenos de Neoplasias/metabolismo , COVID-19/diagnóstico por imagem , COVID-19/metabolismo , Integrinas/metabolismo , Pulmão/diagnóstico por imagem , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Idoso , Humanos , MasculinoRESUMO
Cardiac 18F-FDG PET has been used in clinics to assess myocardial glucose metabolism. Its ability for imaging myocardial glucose transport, however, has rarely been exploited in clinics. Using the dynamic FDG-PET scans of ten patients with coronary artery disease, we investigate in this paper appropriate dynamic scan and kinetic modeling protocols for efficient quantification of myocardial glucose transport. Three kinetic models and the effect of scan duration were evaluated by using statistical fit quality, assessing the impact on kinetic quantification, and analyzing the practical identifiability. The results show that the kinetic model selection depends on the scan duration. The reversible two-tissue model was needed for a one-hour dynamic scan. The irreversible two-tissue model was optimal for a scan duration of around 10-15 minutes. If the scan duration was shortened to 2-3 minutes, a one-tissue model was the most appropriate. For global quantification of myocardial glucose transport, we demonstrated that an early dynamic scan with a duration of 10-15 minutes and irreversible kinetic modeling was comparable to the full one-hour scan with reversible kinetic modeling. Myocardial glucose transport quantification provides an additional physiological parameter on top of the existing assessment of glucose metabolism and has the potential to enable single tracer multiparametric imaging in the myocardium.
RESUMO
PURPOSE: The study was undertaken to develop and evaluate the potential of an integrin αvß6-binding peptide (αvß6-BP) for noninvasive imaging of a diverse range of malignancies with PET. EXPERIMENTAL DESIGN: The peptide αvß6-BP was prepared on solid phase and radiolabeled with 4-[18F]fluorobenzoic acid. In vitro testing included ELISA, serum stability, and cell binding studies using paired αvß6-expressing and αvß6-null cell lines. In vivo evaluation (PET/CT, biodistribution, and autoradiography) was performed in a mouse model bearing the same paired αvß6-expressing and αvß6-null cell xenografts. A first-in-human PET/CT imaging study was performed in patients with metastatic lung, colon, breast, or pancreatic cancer. RESULTS: [18F]αvß6-BP displayed excellent affinity and selectivity for the integrin αvß6 in vitro [IC50(αvß6) = 1.2 nmol/L vs IC50(αvß3) >10 µmol/L] in addition to rapid target-specific cell binding and internalization (72.5% ± 0.9% binding and 52.5% ± 1.8%, respectively). Favorable tumor affinity and selectivity were retained in the mouse model and excretion of unbound [18F]αvß6-BP was rapid, primarily via the kidneys. In patients, [18F]αvß6-BP was well tolerated without noticeable adverse side effects. PET images showed significant uptake of [18F]αvß6-BP in both the primary lesion and metastases, including metastasis to brain, bone, liver, and lung. CONCLUSIONS: The clinical impact of [18F]αvß6-BP PET imaging demonstrated in this first-in-human study is immediate for a broad spectrum of malignancies.