Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
1.
JSES Rev Rep Tech ; 4(3): 413-418, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-39157255

RESUMO

Background: Determine the effect of a novel acellular cannulated dermal allograft on tendon-to-bone healing, retear rates, and clinical outcomes over a 12-month period. Methods: This was a single surgeon prospective nonrandomized case series. Patients with medium sized full-thickness superior and posterosuperior rotator cuff tears, as confirmed by magnetic resonance imaging, were consented. Patients were excluded if they had fatty atrophy indicative of Goutallier grade III or IV. The allograft is a cannulated rectangular prism that has a 5-year shelf life, does not require prehydration, and does not need to be trimmed to size. Outcome metrics included ultrasound assessment at 1-year as well as 6-month patient-reported outcomes (PROs) scores. Results: 31 patients consented and enrolled in this consecutive cohort series. 9 patients were excluded, and statistical analysis was performed on the remaining 22 patients. There were 9 females and 13 males. The average age was 59.27 ± 7.48 year old. The average supraspinatus short axis measurement in males was 0.56 ± 0.12 cm and 0.52 ± 0.09 cm in females (P = .44). The average supraspinatus long axis measurement in males was 0.61 ± 0.18 cm and 0.55 ± 0.14 cm in females (P = .46). The average infraspinatus short axis measurement in males was 0.48 ± 0.10 cm and 0.50 ± 0.13 in females (P = .74). The average infraspinatus long axis measurement in males was 0.44 ± 0.12 cm and 0.43 ± 0.08 cm in females (P = .84). Of the 19 patients who completed baseline and 6-month PRO's, 17 achieved the minimal clinical important difference for American Shoulder and Elbow Surgeons and Patient-Reported Outcomes Measurement Information SystemUE 7a. Retear occurred in 2 cases. The remaining 20 cases have all demonstrated healing or fully healed repairs at their most recent clinical visits with no additional cases of retears. Conclusion: This study is the first to report the results of a novel acellular dermal allograft for rotator cuff repair augmentation. Satisfactory PRO measures and robust tendon healing at 1 year, as measured by ultrasound, demonstrate the utility of a cannulated human acellular dermal allograft as a viable biologic augmentation device for rotator cuff repair.

2.
J Can Dent Assoc ; 77: b132, 2011.
Artigo em Inglês | MEDLINE | ID: mdl-22067067

RESUMO

High-quality radiographs are essential in diagnosing pathology of the jaw. When appropriate radiographs are not submitted to the pathologist along with a biopsy specimen, misdiagnosis and mismanagement may occur. In this case study, we highlight the complementary value of panoramic and intraoral radiographs in allowing a definitive diagnosis of a mixed lesion of the jaw and preventing inappropriate treatment. Although many general dental practitioners tend to refer potential bony pathology, they should acquire and communicate high-quality radiographic information to specialty providers so that a precise diagnosis can be made.


Assuntos
Displasia Fibrosa Óssea/diagnóstico por imagem , Doenças Mandibulares/diagnóstico por imagem , Radiografia Panorâmica , Biópsia , Diagnóstico Diferencial , Displasia Fibrosa Óssea/patologia , Humanos , Doenças Mandibulares/patologia , Adulto Jovem
3.
J Strength Cond Res ; 24(7): 1755-62, 2010 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-20543730

RESUMO

The purpose of this study was to examine relationships between laboratory tests and on-ice skating performance in division I men's hockey athletes. Twenty-one men (age 20.7 +/- 1.6 years) were assessed for body composition, isokinetic force production in the quadriceps and hamstring muscles, and anaerobic muscle power via the Wingate 30-second cycle ergometer test. Air displacement plethysmography was used to determine % body fat (%FAT), fat-free mass (FFM), and fat mass. Peak torque and total work during 10 maximal effort repetitions at 120 degrees .s were measured during concentric muscle actions using an isokinetic dynamometer. Muscle power was measured using a Monark cycle ergometer with resistance set at 7.5% of body mass. On-ice skating performance was measured during 6 timed 89-m sprints with subjects wearing full hockey equipment. First length skate (FLS) was 54 m, and total length skate (TLS) was 89 m with fastest and average skating times used in the analysis. Correlation coefficients were used to determine relationships between laboratory testing and on-ice performance. Subjects had a body mass of 88.8 +/- 7.8 kg and %FAT of 11.9 +/- 4.6. First length skate-Average and TLS-Average skating times were moderately correlated to %FAT ([r = 0.53; p = 0.013] and [r = 0.57; p = 0.007]) such that a greater %FAT was related to slower skating speeds. First length skate-Fastest was correlated to Wingate percent fatigue index (r = -0.48; p = 0.027) and FLS-Average was correlated to Wingate peak power per kilogram body mass (r = -0.43; p = 0.05). Laboratory testing of select variables can predict skating performance in ice hockey athletes. This information can be used to develop targeted and effective strength and conditioning programs that will improve on-ice skating speed.


Assuntos
Desempenho Atlético/fisiologia , Composição Corporal/fisiologia , Hóquei/fisiologia , Perna (Membro)/fisiologia , Força Muscular/fisiologia , Patinação/fisiologia , Anaerobiose/fisiologia , Atletas , Humanos , Masculino , Músculo Quadríceps/fisiologia , Torque , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA