1.
PLoS One ; 19(1): e0295121, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38266033

RESUMO

OBJECTIVES: During the insertion of cochlear implant (CI) electrode arrays, forces occur which may cause trauma and poorer hearing outcomes. Unfortunately, research groups investigating factors influencing insertion forces come to contradicting results, especially regarding insertion speed. This study was conducted to investigate the origin of these contradicting results and to determine how different testing conditions influence experimental findings. METHODS: Repeated, automated insertions with three different FLEX28 CI electrode arrays (MED-EL, Innsbruck, Austria) were performed into a newly developed, anatomically correct and 3D-printed mean scala tympani phantom. The testing protocol for each electrode included variations in insertion speed (v = 0.1-2.0 mm/s) and lubrication (90%, 50%, and 10% liquid soap), resulting in 51 insertions per electrode array and a total of 153 insertions. RESULTS: The test setup and protocol allowed for repeatable insertions with only minimal change in the morphology of the insertion force profiles per testing condition. Strong but varying dependencies of the maximal insertion forces and work were found regarding both lubrication and speed: work-speed dependency is constant for the 10% lubricant, negative for the 50% lubricant and positive for the 90% lubricant. CONCLUSION: Our results can explain part of the contradicting results found within previous studies by translating interrelations known from lubricated rubber friction to the field of CI electrode array insertion. We show that the main driver behind measured bulk forces are most likely the generated friction forces, which are strongly dependent on insertion speed and lubrication. The employed test setup allows for conducting repeatable and comparable insertion studies, which can be recapitulated by other centers due to the detailed explanation of the test setup as well as the developed and freely available insertion phantom. This study hence represents another important step toward standardizing CI array insertion testing.


Assuntos
Implante Coclear , Implantes Cocleares , Lubrificação , Cóclea , Lubrificantes
2.
Pharmaceutics ; 15(3)2023 Feb 22.
Artigo em Inglês | MEDLINE | ID: mdl-36986587

RESUMO

Cochlear implants are well established to treat severe hearing impairments. Despite many different approaches to reduce the formation of connective tissue after electrode insertion and to keep electrical impedances low, results are not yet satisfying. Therefore, the aim of the current study was to combine the incorporation of 5% dexamethasone in the silicone body of the electrode array with an additional polymeric coating releasing diclofenac or the immunophilin inhibitor MM284, some anti-inflammatory substances not yet tested in the inner ear. Guinea pigs were implanted for four weeks and hearing thresholds were determined before implantation and after the observation time. Impedances were monitored over time and, finally, connective tissue and the survival of spiral ganglion neurons (SGNs) were quantified. Impedances increased in all groups to a similar extent but this increase was delayed in the groups with an additional release of diclofenac or MM284. Using Poly-L-lactide (PLLA)-coated electrodes, the damage caused during insertion was much higher than without the coating. Only in these groups, connective tissue could extend to the apex of the cochlea. Despite this, numbers of SGNs were only reduced in PLLA and PLLA plus diclofenac groups. Even though the polymeric coating was not flexible enough, MM284 seems to especially have potential for further evaluation in connection with cochlear implantation.

3.
IEEE Trans Biomed Eng ; 70(1): 390-398, 2023 01.
Artigo em Inglês | MEDLINE | ID: mdl-35939462

RESUMO

OBJECTIVES: Drilling a minimally invasive access to the inner ear is a demanding task in which a computer-assisted surgical system can support the surgeon. Herein, we describe the design of a new micro-stereotactic targeting system dedicated to cochlear implant (CI) surgery and its experimental evaluation in an ex vivo study. METHODS: The proposed system consists of a reusable, bone-anchored reference frame, and a patient-specific drilling jig on top of it. Individualization of the jig is simplified to a single counterbored hole drilled out of a blank. For accurate counterboring, the setup includes a manufacturing device for individual positioning of the blank. The system was tested in a preclinical setting using twelve human cadaver donors. Cone beam computed tomograph (CBCT) scans were obtained and a drilling trajectory was planned pointing towards the basal part of the cochlea. The surgical drill was moved forward manually and slowly while the jig constrained the drill along the predetermined path. RESULTS: Drilling could be performed with preservation of facial nerve in all specimens. The mean error caused by the system at the target point in front of the cochlea was 0.30 mm ± 0.11 mm including an inaccuracy of 0.09 mm ± 0.03 mm for counterboring the guiding aperture into the jig. CONCLUSION: Feasibility of the proposed system to perform a minimally invasive posterior tympanotomy approach was shown successfully in all specimens. SIGNIFICANCE: First evaluation of the new system in a comprehensive ex vivo study demonstrating sufficient accuracy and the feasibility of the whole concept.


Assuntos
Implante Coclear , Implantes Cocleares , Cirurgia Assistida por Computador , Humanos , Procedimentos Cirúrgicos Minimamente Invasivos , Cóclea/diagnóstico por imagem , Cóclea/cirurgia
4.
Front Neurol ; 13: 829478, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35547379

RESUMO

A minimally-invasive surgical (MIS) approach to cochlear implantation, if safe, practical, simple in surgical handling, and also affordable has the potential to replace the conventional surgical approaches. Our MIS approach uses patient-specific drilling templates (positioning jigs). While the most popular MIS approaches use robots, the robotic aspect is literally put aside, because our high-precision parallel kinematics is only used to individualize a positioning jig. This jig can then be mounted onto a bone-anchored mini-stereotactic frame at the patient's skull and used to create a drill-hole through the temporal bone to the patient's cochlea. We present the first clinical experience where we use sham drill bits of different diameters instead of drilling into the bone in order to demonstrate the feasibility and accuracy.

5.
Life (Basel) ; 11(5)2021 Apr 21.
Artigo em Inglês | MEDLINE | ID: mdl-33919445

RESUMO

In the field of cochlear implantation, artificial/physical models of the inner ear are often employed to investigate certain phenomena like the forces occurring during implant insertions. Up to now, no such models are available for the analysis of diffusion processes inside the cochlea although drug delivery is playing an increasingly important role in this field. For easy access of the cochlea along its whole profile, e.g., for sequential sampling in an experimental setting, such a model should ideally be longitudinal/uncoiled. Within this study, a set of 15 micro-CT imaging datasets of human cochleae was used to derive an average representation of the scala tympani. The spiral profile of this model was then uncoiled along different trajectories, showing that these trajectories influence both length and volume of the resulting longitudinal model. A volumetric analysis of the average spiral model was conducted to derive volume-to-length interrelations for the different trajectories, which were then used to generate two tubular, longitudinal scala tympani models with volume and length properties matching the original, spiral profile. These models can be downloaded for free and used for reproducible and comparable simulative and experimental investigations of diffusion processes within the inner ear.

6.
Mol Pharm ; 12(10): 3749-58, 2015 Oct 05.
Artigo em Inglês | MEDLINE | ID: mdl-26310827

RESUMO

tTF-NGR retargets the extracellular domain of tissue factor via a C-terminal peptide GNGRAHA, a ligand of the surface protein aminopeptidase N (CD13) and upon deamidation of integrin αvß3, to tumor vasculature. tTF-NGR induces tumor vascular infarction with consecutive antitumor activity against xenografts and selectively inhibits tumor blood flow in cancer patients. Since random PEGylation resulted in favorable pharmacodynamics of tTF-NGR, we performed site-directed PEGylation of PEG units to the N-terminus of tTF-NGR to further improve the antitumor profile of the molecule. Mono-PEGylation to the N-terminus did not change the procoagulatory activity of the tTF-NGR molecule as measured by Factor X activation. Experiments to characterize pharmacokinetics in mice showed a more than 1 log step higher mean area under the curve of PEG20k-tTF-NGR over tTF-NGR. Acute (24 h) tolerability upon intravenous application for the mono-PEGylated versus non-PEGylated tTF-NGR compounds was comparable. PEG20k-tTF-NGR showed clear antitumor efficacy in vivo against human tumor xenografts when systemically applied. However, site-directed mono-PEGylation to the N-terminus does not unequivocally improve the therapeutic profile of tTF-NGR.


Assuntos
Neoplasias/tratamento farmacológico , Neovascularização Patológica/tratamento farmacológico , Oligopeptídeos/metabolismo , Proteínas Recombinantes de Fusão/uso terapêutico , Tromboplastina/uso terapêutico , Animais , Linhagem Celular Tumoral , Clonagem Molecular , Humanos , Espectrometria de Massas , Camundongos , Camundongos Nus , Transplante de Neoplasias , Neoplasias/irrigação sanguínea , Polietilenoglicóis/metabolismo , Domínios e Motivos de Interação entre Proteínas , Tromboplastina/química
7.
Circ Arrhythm Electrophysiol ; 8(2): 308-17, 2015 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-25744570

RESUMO

BACKGROUND: In the meantime, catheter ablation is widely used for the treatment of persistent atrial fibrillation (AF). There is a paucity of data about long-term outcomes. This study evaluates (1) 5-year single and multiple procedure success and (2) prognostic factors for arrhythmia recurrences after catheter ablation of persistent AF using the stepwise approach aiming at AF termination. METHODS AND RESULTS: A total of 549 patients with persistent AF underwent de novo catheter ablation using the stepwise approach (2007-2009). A total of 493 patients were included (Holter ECGs ≥ every 6 months). Mean follow-up was 59 ± 16 months with 2.1 ± 1.1 procedures per patient. Single and multiple procedure success rates were 20.1% and 55.9%, respectively (80% off antiarrhythmic drug). Antiarrhythmic drug-free multiple procedure success was 46%. Long-term recurrences (n=171) were paroxysmal AF in 48 patients (28%) and persistent AF/atrial tachycardia in 123 patients (72%). Multivariable recurrent event analysis revealed the following factors favoring arrhythmia recurrence: failure to terminate AF during index procedure (hazard ratio [HR], 1.279; 95% confidence interval [CI], 1.093-1.497; P = 0.002), number of procedures (HR, 1.154; 95% CI, 1.051-1.267; P = 0.003), female sex (HR, 1.263; 95% CI, 1.027-1.553; P = 0.027), and the presence of structural heart disease (HR, 1.236; 95% CI, 1.003-1.524; P = 0.047). AF termination was correlated with a higher rate of consecutive procedures because of atrial tachycardia recurrences (P = 0.003; HR, 1.71; 95% CI, 1.20-2.43). CONCLUSIONS: Catheter ablation of persistent AF using the stepwise approach provides limited long-term freedom of arrhythmias often requiring multiple procedures. AF termination, the number of procedures, sex, and the presence of structural heart disease correlate with outcome success. AF termination is associated with consecutive atrial tachycardia procedures.


Assuntos
Fibrilação Atrial/cirurgia , Ablação por Cateter , Frequência Cardíaca , Adulto , Idoso , Idoso de 80 Anos ou mais , Antiarrítmicos/uso terapêutico , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/fisiopatologia , Flutter Atrial/diagnóstico , Flutter Atrial/etiologia , Flutter Atrial/fisiopatologia , Flutter Atrial/terapia , Ablação por Cateter/efeitos adversos , Intervalo Livre de Doença , Eletrocardiografia Ambulatorial , Feminino , Seguimentos , Frequência Cardíaca/efeitos dos fármacos , Humanos , Estimativa de Kaplan-Meier , Masculino , Pessoa de Meia-Idade , Análise Multivariada , Valor Preditivo dos Testes , Recidiva , Reoperação , Estudos Retrospectivos , Fatores de Risco , Fatores Sexuais , Taquicardia Supraventricular/diagnóstico , Taquicardia Supraventricular/etiologia , Taquicardia Supraventricular/fisiopatologia , Taquicardia Supraventricular/terapia , Fatores de Tempo , Resultado do Tratamento , Adulto Jovem
8.
J Med Chem ; 56(6): 2337-47, 2013 Mar 28.
Artigo em Inglês | MEDLINE | ID: mdl-23496322

RESUMO

tTF-NGR consists of the extracellular domain of tissue factor and the peptide GNGRAHA, a ligand of the surface protein aminopeptidase N and of integrin αvß3. Both surface proteins are upregulated on endothelial cells of tumor vessels. tTF-NGR shows antitumor activity in xenografts and inhibition of tumor blood flow in cancer patients. We performed random TMS(PEG)12 PEGylation of tTF-NGR to improve the antitumor profile of the molecule. PEGylation resulted in an approximately 2-log step decreased procoagulatory activity of the molecule. Pharmacokinetic studies in mice showed a more than 1-log step higher mean area under the curve. Comparison of the LD10 values for both compounds and their lowest effective antitumor dose against human tumor xenografts showed an improved therapeutic range (active/toxic dose in mg/kg body weight) of 1/5 mg/kg for tTF-NGR and 3/>160 mg/kg for TMS(PEG)12 tTF-NGR. Results demonstrate that PEGylation can significantly improve the therapeutic range of tTF-NGR.


Assuntos
Antineoplásicos/farmacologia , Vasos Sanguíneos/efeitos dos fármacos , Vasos Sanguíneos/metabolismo , Fibrossarcoma/irrigação sanguínea , Oligopeptídeos/química , Polietilenoglicóis/química , Tromboplastina/metabolismo , Animais , Antineoplásicos/química , Antineoplásicos/metabolismo , Antineoplásicos/farmacocinética , Linhagem Celular Tumoral , Feminino , Humanos , Camundongos , Modelos Moleculares , Conformação Proteica , Tromboplastina/química , Ensaios Antitumorais Modelo de Xenoenxerto
SELEÇÃO DE REFERÊNCIAS