Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 22
Filtrar
1.
Phys Med ; 109: 102574, 2023 May.
Artigo em Inglês | MEDLINE | ID: mdl-37004360

RESUMO

PURPOSE: To assess the impact of the automatic tube current modulation (ATCM) on virtual monoenergetic images (VMIs) quality in dual-source CT(DSCT). MATERIALS AND METHODS: Acquisitions were performed on DSCT using the Mercury phantom. The acquisition parameters for an abdomen-pelvic examination with single-energy CT(SECT) and dual-energy CT(DECT) imaging were used. Acquisitions were performed for each imaging mode using fixed mAs and ATCM. The mAs value was set to obtain a volume CT dose index of 11 mGy in fixed mAs acquisitions. This value was used as the reference mAs in ATCM acquisitions. The noise power spectrum and task-based transfer function at 40,50,60 and 70 keV levels were computed on VMIs and SECT images. The detectability index (d') was calculated for a lesion with an iodine concentration of 10 mg/mL. RESULTS: The noise magnitude on VMIs was higher with the ATCM system than with fixed mAs for all energy levels and section diameters of 21,26 and 31 cm. The noise texture and spatial resolution were similar between the fixed mAs and ATCM acquisitions for both imaging modes. The d' values were lower for all energy levels with ATCM than with fixed mAs acquisitions for 21 and 26 cm diameters by -39.82 ± 9.32%, similar at 31 cm diameter -4.13 ± 0.24% and higher at 36 cm diameter 10.40 ± 6.69%. It was higher on VMIs at all energy levels compared to SECT images. CONCLUSIONS: The ATCM system could be used with DECT imaging to optimize patient exposure without changing the noise texture and spatial resolution of VMIs compared to fixed mAs and SECT.


Assuntos
Iodo , Tomografia Computadorizada por Raios X , Humanos , Tomografia Computadorizada por Raios X/métodos , Imagens de Fantasmas , Tomografia Computadorizada de Feixe Cônico , Doses de Radiação
2.
AJNR Am J Neuroradiol ; 42(6): 1087-1092, 2021 06.
Artigo em Inglês | MEDLINE | ID: mdl-33858823

RESUMO

BACKGROUND AND PURPOSE: Few reports described flow diversion for ICA bifurcation aneurysms. Our aim was to provide further insight into flow diversion for ICA bifurcation aneurysms difficult to treat with other strategies. MATERIALS AND METHODS: Consecutive patients receiving flow diverters for unruptured ICA bifurcation aneurysms were collected. Aneurysm occlusion (O'Kelly-Marotta grading scale) and clinical outcomes were evaluated. RESULTS: Twenty saccular ICA bifurcation aneurysms were treated with the Pipeline Embolization Device deployed from the M1 to the ICA, covering the aneurysm and the A1 segment. All patients presented with an angiographic visualized contralateral flow from the anterior communicating artery. Mean aneurysm size was 6.5 (SD, 3.2) mm (range, 4.5-20 mm). All lesions had an unfavorable dome-to-neck ratio (mean/median, 1.6/1.6; range, 0.8-2.8; interquartile range = 0.5) or aspect ratio for coiling (mean/median = 1.5/1.55; range, 0.8-2.5; interquartile range = 0.6). One was a very large aneurysm (20 mm). Nineteen medium-sized lesions were completely occluded during the angiographic follow-up (13 months). No cases of aneurysm rupture or retreatment were reported. No adverse events were described. Aneurysm occlusion was associated with the asymptomatic flow modification of the covered A1 that was occluded and contralaterally filled among 10 patients (50%), narrowed among 9 patients (45%), and unchanged in 1 subject (5%). There was no difference in the mean initial diameter of the occluded (2.1 [SD 0.4] mm; range, 1.6-3 mm) and narrowed (2 [SD, 0.2] mm; range, 1.7-2.6 mm) A1 segments. CONCLUSIONS: Medium-sized unruptured ICA bifurcation aneurysms with unfavorable morphology for coiling can be treated with M1 ICA flow diversion. Aneurysm occlusion is associated with flow modifications of the covered A1 that seems safe in the presence of a favorable collateral anatomy through the anterior communicating artery complex.


Assuntos
Aneurisma Roto , Embolização Terapêutica , Procedimentos Endovasculares , Humanos , Aneurisma Intracraniano/diagnóstico por imagem , Aneurisma Intracraniano/terapia , Estudos Retrospectivos , Stents , Resultado do Tratamento
3.
Eur Radiol ; 31(7): 5324-5334, 2021 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-33449188

RESUMO

OBJECTIVES: To compare the spectral performance of dual-energy CT (DECT) platforms using task-based image quality assessment based on phantom data. MATERIALS AND METHODS: Two CT phantoms were scanned on four DECT platforms: fast kV-switching CT (KVSCT), split filter CT (SFCT), dual-source CT (DSCT), and dual-layer CT (DLCT). Acquisitions on each phantom were performed using classical parameters of abdomen-pelvic examination and a CTDIvol at 10 mGy. Noise power spectrum (NPS) and task-based transfer function (TTF) were evaluated from 40 to 140 keV of virtual monoenergetic images. A detectability index (d') was computed to model the detection task of two contrast-enhanced lesions as function of keV. RESULTS: The noise magnitude decreased from 40 to 70 keV for all DECT platforms, and the highest noise magnitude values were found for KVSCT and SFCT and the lowest for DSCT and DLCT. The average NPS spatial frequency shifted towards lower frequencies as the energy level increased for all DECT platforms, smoothing the image texture. TTF values decreased with the increase of keV deteriorating the spatial resolution. For both simulated lesions, higher detectability (d' value) was obtained at 40 keV for DLCT, DSCT, and SFCT but at 70 keV for KVSCT. The detectability of both simulated lesions was highest for DLCT and DSCT. CONCLUSION: Highest detectability was found for DLCT for the lowest energy levels. The task-based image quality assessment used for the first time for DECT acquisitions showed the benefit of using low keV for the detection of contrast-enhanced lesions. KEY POINTS: • Detectability of both simulated contrast-enhanced lesions was higher for dual-layer CT for the lowest energy levels. • The image noise increased and the image texture changed for the lowest energy levels. • The detectability of both simulated contrast-enhanced lesions was highest at 40 keV for all dual-energy CT platforms except for fast kV-switching platform.


Assuntos
Imagem Radiográfica a Partir de Emissão de Duplo Fóton , Tomografia Computadorizada por Raios X , Abdome/diagnóstico por imagem , Humanos , Imagens de Fantasmas , Razão Sinal-Ruído
4.
Phys Med ; 77: 36-42, 2020 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-32771702

RESUMO

PURPOSE: To assess the impact of iterative reconstructions on image quality and detectability of focal liver lesions in low-energy monochromatic images from a Fast kV-Switching Dual Energy CT (KVSCT) platform. METHODS: Acquisitions on an image-quality phantom were performed using a KVSCT for three dose levels (CTDIvol:12.72/10.76/8.79 mGy). Raw data were reconstructed for five energy levels (40/50/60/70/80 keV) using Filtered Back Projection (FBP) and four levels of ASIR (ASIR30/ASIR50/ASIR70/ASIR100). Noise power spectrum (NPS) and task-based transfer function (TTF) were measured before computing a Detectability index (d') to model the detection task of liver metastasis (LM) and hepatocellular carcinoma (HCC) as function of keV. RESULTS: From 40 to 70 keV, noise-magnitude was reduced on average by -68% ± 1% with FBP; -61% ± 3% with ASIR50 and -52% ± 6% with ASIR100. The mean spatial frequency of the NPS decreased when the energy level decreased and the iterative level increased. TTF values at 50% decreased as the energy level increased and as the percentage of ASIR increased. The detectability of both lesions increased with increasing dose level and percentage of ASIR. For the LM, d' peaked at 70 keV for all reconstruction types, except for ASIR70 at 12.72 mGy and ASIR100, where d' peaked at 50 keV. For HCC, d' peaked at 60 keV for FBP and ASIR30 but peaked at 50 keV for ASIR50, ASIR70 and ASIR100. CONCLUSIONS: Using percentage of ASIR above 50% at low-energy monochromatic images could limit the increase of noise-magnitude, benefit from spatial resolution improvement and hence enhance detectability of subtle low contrast focal liver lesions such as HCC.


Assuntos
Carcinoma Hepatocelular/diagnóstico por imagem , Neoplasias Hepáticas/diagnóstico por imagem , Fígado/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Humanos , Imagens de Fantasmas , Doses de Radiação , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Tomografia Computadorizada por Raios X/instrumentação
5.
Diagn Interv Imaging ; 101(7-8): 473-479, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32499192

RESUMO

PURPOSE: To compare the evaluation of malignant focal liver lesions (FLLs) using a semi-automated RECIST tool with a standard and an ultra-low dose (ULD) computed tomography (CT) protocol. MATERIALS AND METHODS: Thirty-four patients with malignant FLLs underwent two abdominal-pelvic CT examinations one using a standard protocol and one using an ULD protocol. There were 23 men and 11 women with a mean age 64.3±14.4 (SD) years (range: 22-91 years). Dosimetric indicators were recorded, and effective dose was calculated for both examinations. Mean malignant FLL attenuation, image noise and contrast-to-noise-ratio (CNR) were compared. The largest malignant FLL per patient was evaluated using the semi-automated RECIST tool to determine longest axis length, longest orthogonal axis length, volume and World Health Organisation area. RESULTS: Dosimetric values were significantly reduced by -56% with ULD compared to standard protocol. No differences in mean malignant FLL attenuation values were found between the two protocols. Image noise was significantly increased for all locations (P<0.05) with ULD compared to standard protocol, and CNR was significantly reduced (P<0.05). On the 34 malignant FLLs analyzed, six semi-automated shapes non-concordant with radiologist's visual impression were highlighted with the software, including one FLL (1/34; 3%) with standard CT acquisition only, three FLLs (3/34; 9%) with ULD CT acquisition only and two FLLs (2/34; 6%) with both CT acquisitions. After manual editing, the concordance of the values of the studied criteria between both acquisitions was good and no significant difference was reported. CONCLUSION: Semi-automated RECIST tool demonstrates good performances using ULD CT protocol. It could be used in routine clinical practice with a ULD protocol for follow-up studies in patients with known malignant FLL.


Assuntos
Neoplasias Hepáticas , Tomografia Computadorizada por Raios X , Idoso , Feminino , Humanos , Neoplasias Hepáticas/diagnóstico por imagem , Masculino , Pessoa de Meia-Idade , Doses de Radiação , Critérios de Avaliação de Resposta em Tumores Sólidos , Software
6.
Diagn Interv Imaging ; 101(6): 373-381, 2020 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-32008994

RESUMO

PURPOSE: The purpose of this study was to assess the impact of tin filter (TF) on X-ray beam quality, image quality and radiation dose and its suitability for routine use for chest and lumbar-spine/pelvis-hip ultralow-dose (ULD) CT examination protocols. MATERIALS AND METHODS: The X-ray beam quality was determined by measuring the half-value layer (HVL) and calculating the mean weighted energy for 100, 120, 150kVp (using standard filtration) and for 100 and 150kVp using TF (Sn100kVp and Sn150kVp, respectively). Acquisitions were performed on a phantom at four dose levels for each previously definedkVp. The mean attenuation (NCT), noise-power-spectrum (NPS) and task-based transfer function (TTF) were computed. The detectability index (d') was computed to model the detection of two lesions in spine and pelvic/hip examination and two for chest exploration. Image quality and detectability using a TF were assessed for two routinely used ULD protocols. RESULTS: The HVL and mean weighted energy increased using a TF for the same tube voltage. Using a TF for the same tube voltage changed NCT for bone and acrylic inserts, decreased the NPS peak without changing the NPS spatial frequency and increased the TTF values. The d' values were improved using a TF and with the dose increase. d' values of all modeled lesions were improved using Sn100kVp and Sn150kVp for the lumbar-spine/pelvis-hip and chest ULD protocols except for sclerotic bone lesion using Sn150kVp. CONCLUSION: The use of TF increases the X-ray beam quality and improves the image quality characteristics in phantom images, thus appearing as a promising tool for reducing dose and/or improving the image quality of ULD protocols.


Assuntos
Interpretação de Imagem Radiográfica Assistida por Computador , Estanho , Humanos , Imagens de Fantasmas , Doses de Radiação , Tomografia Computadorizada por Raios X
7.
Eur Radiol ; 30(2): 1075-1078, 2020 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-31506818

RESUMO

OBJECTIVES: To determine the best compromise between low radiation dose and suitable image quality for the detection of lytic and sclerotic bone lesions of the lumbar spine and pelvis. METHODS: A phantom was scanned using the routine protocol (STD, 13 mGy) and six decreasing dose levels. Raw data were reconstructed using level 3 of iterative reconstruction (IR3) with 1-mm slice thickness for the STD protocol and highest IR levels with 3-mm slice thickness for the others. CTDIvol was used for radiation dose assessment. Quantitative criteria (noise power spectrum [NPS], task-based transfer function [TTF], and the detectability index [d']), as well as qualitative analysis, were used to compare protocols. NPS and TTF were computed using specific software (imQuest). d' was computed for two imaging tasks: lytic and sclerotic bone lesions. A subjective analysis was performed to validate the image quality obtained on the anthropomorphic phantom with the different dose values. RESULTS: Similar d' values were found for CTDIvol from 3 to 4 mGy with IR4 and from 1 to 2 mGy for IR5 compared with d' values using the STD protocol. Image quality was validated subjectively for IR4 but rejected for IR5 (image smoothing). Finally, for the same d', the dose was reduced by 74% compared with the STD protocol, with the CTDIvol being 3.4 mGy for the lumbar spine and for the pelvis. CONCLUSION: A dose level as low as 3.4 mGy, in association with high levels of IR, provides suitable image quality for the detection of lytic and sclerotic bone lesions of the lumbar spine and pelvis. KEY POINTS: • A CTDI volof 3.4 mGy, in association with high iterative reconstruction level, provides suitable image quality for the detection of lytic and sclerotic bone lesions, both at objective and subjective analysis. • Compared with the standard protocol, radiation dose can be reduced up to 74% for the lumbar spine and pelvis. • A task-based image quality assessment using  the detectability index represents an objective method for the assessment of image quality and bridges the gap between complex physical metrics and subjective image analysis.


Assuntos
Neoplasias Ósseas/diagnóstico por imagem , Doses de Radiação , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Tomografia Computadorizada por Raios X/métodos , Algoritmos , Humanos , Vértebras Lombares/diagnóstico por imagem , Pelve/diagnóstico por imagem , Imagens de Fantasmas , Reprodutibilidade dos Testes
8.
Eur Radiol ; 30(1): 487-500, 2020 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-31359122

RESUMO

PURPOSE: To assess the dose performance in terms of image quality of filtered back projection (FBP) and two generations of iterative reconstruction (IR) algorithms developed by the most common CT vendors. MATERIALS AND METHODS: We used four CT systems equipped with a hybrid/statistical IR (H/SIR) and a full/partial/advanced model-based IR (MBIR) algorithms. Acquisitions were performed on an ACR phantom at five dose levels. Raw data were reconstructed using a standard soft tissue kernel for FBP and one iterative level of the two IR algorithm generations. The noise power spectrum (NPS) and the task-based transfer function (TTF) were computed. A detectability index (d') was computed to model the detection task of a large mass in the liver (large feature; 120 HU and 25-mm diameter) and a small calcification (small feature; 500 HU and 1.5-mm diameter). RESULTS: With H/SIR, the highest values of d' for both features were found for Siemens, then for Canon and the lowest values for Philips and GE. For the large feature, potential dose reductions with MBIR compared with H/SIR were - 35% for GE, - 62% for Philips, and - 13% for Siemens; for the small feature, corresponding reductions were - 45%, - 78%, and - 14%, respectively. With the Canon system, a potential dose reduction of - 32% was observed only for the small feature with MBIR compared with the H/SIR algorithm. For the large feature, the dose increased by 100%. CONCLUSION: This multivendor comparison of several versions of IR algorithms allowed to compare the different evolution within each vendor. The use of d' is highly adapted and robust for an optimization process. KEY POINTS: • The performance of four CT systems was evaluated by using imQuest software to assess noise characteristic, spatial resolution, and lesion detection. • Two task functions were defined to model the detection task of a large mass in the liver and a small calcification. • The advantage of task-based image quality assessment for radiologists is that it does not include only complicated metrics, but also clinically meaningful image quality.


Assuntos
Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Tomografia Computadorizada por Raios X/métodos , Algoritmos , Calcinose/diagnóstico por imagem , Humanos , Hepatopatias/diagnóstico por imagem , Neoplasias Hepáticas/diagnóstico por imagem , Imagens de Fantasmas , Garantia da Qualidade dos Cuidados de Saúde/métodos , Doses de Radiação , Interpretação de Imagem Radiográfica Assistida por Computador/normas , Radiometria/métodos , Cintilografia , Software , Tomografia Computadorizada por Raios X/normas
9.
Diagn Interv Imaging ; 101(1): 7-14, 2020 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-31324590

RESUMO

PURPOSE: The purpose of this study was to evaluate a cooperation program in order to compare incidence of complications after peripherally inserted central catheter (PICC) placement between radiologists and technicians. MATERIALS AND METHODS: PICC placement technique was standardized with ultrasound-guided puncture and fluoroscopic guidance. Numbers of PICC delegated to technicians, and PICC placement difficulties, were prospectively recorded for the whole study population whereas complications such as PICC infection, deep venous thrombosis and catheter occlusion were prospectively recorded until PICC removal for a subgroup of patients included during one month. RESULTS: A total of 722 patients had PICC placement. There were 382 men and 340 women with a mean age of 66.8±15.8 (SD) years (range: 18-94years); of these, 442/722 patients (61.22%) were included in the cooperation program with 433/722 patients (59.97%) who effectively had PICC placement by technicians and 289/722 (40.03%) by radiologists. Technicians needed radiologists' help for 23/442 patients (5.20%) including 6 failed PICC placement subsequently performed by radiologists. Twenty complications (20/77; 26%) were recorded in the subgroup of 77 patients studied for complications. No differences in complications rate were found between the 33 patients who underwent PICC placement by radiologists (6/33; 18%) and the 44 patients who underwent PICC placement by technicians (14/44; 32%) (P=0.296). Complications included 8 PICC-related infections (8/77; 10.4%), 3 deep venous thromboses (3/77; 3.9%) and 9 catheter occlusions (9/77; 11.7%). CONCLUSION: PICC placement led by technicians is feasible and safe without statistical difference in terms of complications compared to PICC placement made by radiologists.


Assuntos
Cateterismo Periférico/normas , Complicações Pós-Operatórias/epidemiologia , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Pessoal Técnico de Saúde , Cateterismo Periférico/efeitos adversos , Feminino , Humanos , Incidência , Masculino , Pessoa de Meia-Idade , Equipe de Assistência ao Paciente , Complicações Pós-Operatórias/etiologia , Estudos Prospectivos , Radiologia , Adulto Jovem
10.
Diagn Interv Imaging ; 100(12): 763-770, 2019 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-31473164

RESUMO

PURPOSE: To compare the noise-magnitude and noise-texture obtained using strong kernel across two generations of iterative reconstruction (IR) algorithms proposed by three manufacturers. MATERIALS AND METHODS: Five computed tomography (CT) systems equipped with two generations of IR algorithm (hybrid/statistical IR [H/SIR] or full/partial model-based IR [MBIR]) were compared. Acquisitions on Catphan 600 phantom were performed at 120kV and three dose levels (CTDIvol: 3, 7 and 12mGy). Raw data were reconstructed using standard "bone" kernel for filtered back projection and one iterative level of two generations of IR algorithms. Contrast-to-noise ratio (CNR) was computed using three regions of interest placed semi-automatically: two placed in the low-density polyethylene and Teflon inserts and another placed on the solid water. Noise power spectrum (NPS) was computed to assess the NPS-peak and noise-texture. RESULTS: CNR was significantly greater in MBIR compared to H/SIR algorithms for all CT systems (P<0.01). CNR were improved on average from H/SIR to MBIR of 36±14% [SD] (range: 24-57%) for GE-Healthcare, 109±19 [SD] % (range: 89-139%) for Philips Healthcare and 42±5 [SD] % (range: 36-47%) for Siemens Healthineers. The mean NPS peak decreased from H/SIR to MBIR by -41±6 [SD] % (range: -47--35%) for GE Healthcare, -79±3 [SD] % (range: -82--76%) for Philips Healthcare and -52±2 [SD] % (range: -54--51%) for Siemens Healthineers systems. NPS spatial frequencies were greater with MBIR than with H/SIR for Philips Healthcare (20 ± 2 [SD] %; range: 19-22%) and for Siemens Healthineers (9±5 [SD] %; range: 4-14%) but lower for GE Healthcare (-17±3 [SD] %; range: -14--20%). CONCLUSION: Using bone kernel with recent MBIR algorithms reduces the noise-magnitude for all CT systems assessed. Noise texture shifted towards high frequency for Siemens Healthineers and Philips Healthcare but the opposite for GE Healthcare.


Assuntos
Algoritmos , Razão Sinal-Ruído , Tomografia Computadorizada por Raios X , Humanos , Aumento da Imagem , Imagens de Fantasmas , Dosagem Radioterapêutica
11.
Diagn Interv Imaging ; 100(7-8): 401-410, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-31130375

RESUMO

PURPOSE: To compare the noise-magnitude and noise-texture across two generations of iterative reconstruction (IR) algorithms proposed by three manufacturers according to the dose level. MATERIALS AND METHODS: Five computed tomography (CT) systems equipped with two generations of IR algorithms (hybrid/statistical IR [H/SIR] or full/partial model-based IR [MBIR]) were compared. Acquisitions on Catphan 600 phantom were performed at 120kV and three dose levels (3-, 7- and 12-mGy). Raw data were reconstructed using standard "soft tissue" kernel for filtered back projection and one iterative level of two generations of IR algorithms. Contrast to-noise-ratio (CNR) was computed using three regions of interest: two of them placed in the low-density polyethylene (LDPE) and Teflon® inserts and another placed on the solid water. Noise power spectrum (NPS) was computed to assess the noise-magnitude (NPS peak) and noise-texture (NPS spatial frequency). RESULTS: CNR increased significantly in MBIR compared to H/SIR algorithms for General-Electric (GE) Healthcare (45%±12 [SD]) and Philips Healthcare systems (62%±11 [SD]) (P<0.001). Regarding Siemens Healthineers systems, CNR of MBIR was significantly lower than that of H/SIR (mean difference: -4%±5 [SD]) (P<0.001) for Teflon® insert but not for LDPE insert (mean difference: -4%±7 [SD]) (P=N.S.). NPS peaks were lower with MBIR than with H/SIR for GE Healthcare (-42%±8 [SD]) and Philips Healthcare (-75%±4 [SD]) systems, whereas it was greater with MBIR than with H/SIR for Siemens Healthineers (13%±11 [SD]) systems. NPS spatial frequencies were higher with MBIR than with H/SIR for Siemens (14%±10 [SD]) but lower for others (-17%±5 [SD] for GE Healthineers and -55%±3 [SD] for Philips Healthcare systems). CONCLUSION: This study demonstrates that recent MBIR algorithms, by comparison with the preceding generation, differ according to the main manufacturers with respect to noise-magnitude and noise-texture.


Assuntos
Algoritmos , Processamento de Imagem Assistida por Computador , Razão Sinal-Ruído , Tomografia Computadorizada por Raios X , Humanos , Modelos Estatísticos , Imagens de Fantasmas
12.
Diagn Interv Imaging ; 100(5): 269-277, 2019 May.
Artigo em Inglês | MEDLINE | ID: mdl-30709793

RESUMO

PURPOSE: To compare metallic artifact reduction (MAR) algorithms proposed by four vendors according to the delivered dose and iterative level using a phantom study. METHODS: Four CT systems (Revolution GSI®, Ingenuity Elite®, Somatom Edge®, and Aquilion Prime®) equipped with MAR algorithms (Smart MAR®, O-MAR®, iMAR®, and SEMAR®) were compared. Acquisitions were performed with CIRS model 062M Phantom containing a titanium rod core insert using 120kV and two dose levels (3 and 7mGy). Images were reconstructed with and without MAR algorithms using standard "soft tissue" kernel for filtered back projection (FBP) and intermediary iterative level. Artifact propagation was assessed by counting the number of pixels containing a HU outside a defined threshold interval (>100HU and<-80 HU). Artifact correction was evaluated by computing the differences between images with and without MAR. RESULTS: Accuracy of NCT values increased significantly using MAR algorithms, IR, and high dose levels (P<0.001). Image noise reduced -31±15 (SD) % (range: -50%;-14%) with Smart-MAR®, -28±3 (SD) % (range -31%; -25%) with O-MAR®, -32±7 (SD) % (range: -40%; -24%) with iMARCN®, -52±8 (SD) % (range: -60%; -42%) with iMARTH® and -29±6 (SD) % (range: -37%; -23%) with SEMAR®. The number of pixels outside the threshold interval was also reduced using MAR algorithms. Each MAR algorithm corrected in distinct patterns, with satisfactory artifact correction for all MAR algorithms. CONCLUSION: This study demonstrates that artifact correction using MAR algorithms differs according to the main manufacturers, although corrections are satisfactory for all systems. Corrections also improved by using IR and increasing the dose level.


Assuntos
Artefatos , Aumento da Imagem/métodos , Processamento de Imagem Assistida por Computador/métodos , Metais , Imagens de Fantasmas , Tomografia Computadorizada por Raios X/instrumentação , Algoritmos , Humanos , Doses de Radiação , Titânio , Tomografia Computadorizada por Raios X/métodos
13.
Diagn Interv Imaging ; 99(11): 689-698, 2018 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-30262171

RESUMO

PURPOSE: The purpose of this study was to quantify the distribution of trabeculated (T) and compact (C) left ventricular (LV) myocardium masses in a healthy Caucasian population against age, gender and LV parameters, and to provide normal values for T, C and T/C. MATERIALS AND METHODS: One hundred and forty healthy subjects were prospectively recruited and underwent cardiac MRI at 1.5T with a stack of short-axis cine sequences covering the entire LV. End-diastolic volume (EDV), C and T masses were quantified using a semi-automatic method. Ejection fraction (EF) and T/C ratio were computed. RESULTS: We included 70 men and 70 women with a mean age of 44±14 (SD) years (range: 20-69 years). The mean EF was 63.7±6.3 (SD) % (range: 50.7-82.0%), the mean EDV was 75.9±16.2 (SD) mL/m2 (range: 36.4-112.2mL/m2), the mean C mass was 53.9±11.2 (SD) g/m2 (range: 26.5-93.4g/m2) and the mean T mass was 4.9±2.4 (SD) g/m2 (range: 1.1-11.4g/m2). The T/C ratio was 9.2±4.5% (range: 2.0-29.4%). Multivariate ANOVA test showed that the compact mass was influenced by EDV (P<0.0001), EF (P=0.001) and gender (P<0.0001), and the trabeculated mass depended on EDV (P<0.0001), gender (P=0.002) and age (P<0.0001), while the T/C ratio was only influenced by age (P=0.0003). Spearman test showed a correlation between EDV and C (r=0.60; P<0.0001),T (r=0.46; P<0.0001) and T/C ratio (r=0.26; P=0.0023).T and T/C ratio correlated with EF (r=-0.18, P=0.0373; r=-0.18, P=0.0321, respectively). CONCLUSION: While the compact and trabeculated myocardium masses appear to relate separately to the cardiac function, age and gender, their ratio T/C appears to only decrease with age. Furthermore, we propose here normal values for T, C and T/C in a cohort of healthy Caucasians subjects.


Assuntos
Técnicas de Imagem Cardíaca , Ventrículos do Coração/diagnóstico por imagem , Imageamento por Ressonância Magnética , Adulto , Fatores Etários , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Valores de Referência , Fatores Sexuais , População Branca , Adulto Jovem
14.
EJVES Short Rep ; 39: 20-23, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-29988815

RESUMO

INTRODUCTION: The impact of sequential lumbar and intercostal artery occlusion on the risk of spinal cord ischaemia was evaluated; however, an adverse event (paraplegia) was encountered, which resulted in study interruption. Investigations were carried out to understand the reasons for the paraplegia. REPORT: To develop a porcine model of spinal cord ischaemic preconditioning prior to extensive thoraco-abdominal aneurysm endovascular aortic repair, the lumbar arteries were selectively embolised with Onyx 5 days prior to an extended thoracic aortic stent graft. Six pigs were used in this preliminary work. Four cases of paraplegia secondary to accidental migration of Onyx to the anterior spinal artery from the lumbar arteries are reported. Histological analysis confirmed severe spinal ischaemic injury and the presence of Onyx particles in the anterior spinal artery. DISCUSSION: Onyx is used for lumbar artery embolisation in type II endoleak treatment after endovascular aortic repair, and while migration in lumbar arteries is frequent, the risk of spinal cord ischaemia has never been described. The current study demonstrates the risk of paraplegia following Onyx migration to the anterior spinal artery from the lumbar artery in an experimental model. Thus, Onyx treatment for type II endoleaks from lumbar arteries should be used cautiously.

15.
Diagn Interv Imaging ; 99(5): 311-320, 2018 May.
Artigo em Inglês | MEDLINE | ID: mdl-29396085

RESUMO

PURPOSE: The purpose of this study was to evaluate and compare the diagnostic accuracy of ultra-low dose (ULD) computed tomography (CT) with that of standard dose (STD) CT in the detection and characterization of focal liver lesions in neoplastic patients. MATERIALS AND METHODS: A total of 177 neoplastic patients who underwent two abdominopelvic CT examinations (one with STD and one with ULD protocol) for suspected focal liver lesions were included. There were 103 men and 74 women with a mean age of 64.6±14.4 (SD) (range: 19-93 years). Raw data images were reconstructed with iterative reconstruction. Dose length product (DLP) and effective dose for both protocols were compared. Images were independently evaluated by two radiologists for image-quality, diagnostic quality, and confidence level. RESULTS: DLP for STD and ULD were respectively 215.4±92.0 (SD) mGy·cm (range: 76-599mGy·cm) and 90.7±37.2 (SD) mGy·cm (range: 32-254mGy·cm). Effective dose for STD and ULD CT were 3.2±1.4 (SD) mSv (range: 1.1-9.0mSv) and 1.4±0.6 (SD) mSv (range: 0.5 to 3.8mSv). A significant 58% dose reduction was found between the two protocols (P<0.05). Noise, signal-to-noise ratio and contrast-to-noise ratio were higher with the ULD protocol compared to the STD protocol. No differences in subjective image quality were found between the two protocols. STD CT revealed focal liver lesions in 80 patients and ULD CT in 70 patients (P<0.05). ULD protocol resulted in a sensitivity of 83.8% and a specificity of 96.9% for the diagnosis of focal liver lesions although it was not able to characterize them properly (Se 62.5%). CONCLUSION: STD CT helps detect and characterize focal liver lesions. ULD CT offers good performance to detect focal liver lesions but with lower performances for lesion characterization.


Assuntos
Neoplasias Hepáticas/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Doses de Radiação , Reprodutibilidade dos Testes
16.
Diagn Interv Imaging ; 99(5): 321-329, 2018 May.
Artigo em Inglês | MEDLINE | ID: mdl-29396087

RESUMO

PURPOSE: To assess the value of the routine use of radiochromic films in abdominopelvic embolization procedures to improve patient follow-up. METHODS: A total of 55 patients who underwent transcatheter abdominopelvic embolization were prospectively included. Six types of procedures were evaluated including hepatic chemoembolization (HCE), gonadal veins embolization (GVE), uterine elective embolization (UEE), uterine urgent embolization (UUE), abdominal elective embolization (AEE), and abdominal urgent embolization (AUE). Dosimetric indicators (DIs) such as air-kerma (AK) and kerma-area-product (KAP) were collected and peak skin dose (PSD) was measured with radiochromic films. Correlations between PSD and DIs were searched for. RESULTS: The mean (±standard deviation [SD]) PSD for the various procedures were: 1033±502 mGy for HCE; 476±271 mGy for GVE; 460±171 mGy for UEE; 531±263 mGy for UUE; 708±896 mGy for AEE; 683±392 mGy for AUE. Strong correlations were observed between PSD and DIs (r=0.974 for AK and r=0.925 for KAP). PSD was>2Gy in one procedure and all procedures (7/132) procedures resulted in AK>2Gy, mostly for HCE and AEE. CONCLUSION: Dosimetry using radiochromic film is only appropriate for HCE, AEE and AUE, whereas dose-mapping systems present a more suitable solution for all embolizations including those with AK that occasionally exceed 2Gy.


Assuntos
Embolização Terapêutica/métodos , Doses de Radiação , Radiografia Intervencionista/métodos , Abdome , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Pelve , Estudos Prospectivos , Radiometria/métodos , Pele/efeitos da radiação
18.
J Visc Surg ; 153(4 Suppl): 25-31, 2016 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-27374109

RESUMO

Abdominal trauma accounts for nearly 20% of all traumatic injuries. It often involves young patients sustaining multiple injuries, with a high associated mortality rate. Management should begin at the scene of injury and relies on a structured chain of care in order to transport the trauma patient to the appropriate hospital center. Management is multi-disciplinary, involving intensive care specialists, surgeons and radiologists. Imaging to precisely define injury is best performed with whole body dual phase computed tomography, which can also identify the source of bleeding. Non-operative management has developed considerably over the years: this includes selective embolization in case of active bleeding or vascular anomalies in stable or stabilized patients after resuscitation. Embolization has become one of the corner stones of abdominal trauma management and interventional radiologists must play an active role on the trauma team. This overview details the different embolization procedures according to the involved organ and embolic agent used.


Assuntos
Embolização Terapêutica/métodos , Traumatismos Abdominais/terapia , Adolescente , Adulto , França , Humanos , Rim/lesões , Fígado/lesões , Mesentério/lesões , Pelve/lesões , Baço/lesões , Tomografia Computadorizada por Raios X , Centros de Traumatologia , Triagem
20.
Diagn Interv Imaging ; 96(7-8): 707-15, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-26206744

RESUMO

In multiple injuries, features of bleeding from solid organs mostly involve the liver, spleen and kidneys and may be treated by embolization. The indications and techniques for embolization vary between organs and depend on the pathophysiology of the injuries, type of vascularization (anastomotic or terminal) and type of embolization (curative or preventative). Interventional radiologists should have a full understanding of these indications and techniques and management algorithms should be produced within each facility in order to define the respective place of the different treatment options.


Assuntos
Injúria Renal Aguda/diagnóstico , Injúria Renal Aguda/terapia , Embolização Terapêutica/métodos , Serviços Médicos de Emergência , Procedimentos Endovasculares/métodos , Hemorragia/diagnóstico , Hemorragia/terapia , Fígado/lesões , Traumatismo Múltiplo/diagnóstico , Traumatismo Múltiplo/terapia , Ruptura Esplênica/diagnóstico , Ruptura Esplênica/terapia , Angiografia , Comportamento Cooperativo , Humanos , Comunicação Interdisciplinar , Síndrome
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA