RESUMO
BACKGROUND AND AIMS: Glycoprotein (GP) IIb/IIIa inhibitors are recommended in acute myocardial infarction (AMI) for bailout treatment in case of angiographic microvascular obstruction (MVO), also termed no-reflow phenomenon, after percutaneous coronary intervention (PCI) with, however, lacking evidence (class IIa, level C). METHODS: The investigator-initiated, international, multicenter REVERSE-FLOW trial randomized 120 patients with AMI and Thrombolysis In Myocardial Infarction flow grade ≤2 after primary PCI to optimal medical therapy with or without GP IIb/IIIa inhibitor. The primary endpoint was infarct size (%LV) assessed by cardiac magnetic resonance (CMR). Secondary endpoints included CMR-derived MVO and 30-day adverse clinical events. The trial is registered with ClinicalTrials.gov: NCT02739711. RESULTS: The population was predominantly male (76.7%) with a median age of 66 years and ST-elevation myocardial infarction in 73.3% of patients. Clinical and angiographic characteristics were well balanced between the cohorts. Patients in the treatment group (n=62) received eptifibatide (n=41) or tirofiban (n=21). Infarct size assessed by CMR imaging was similar in both study groups (25.4% of left ventricular mass [LV] vs. 25.2%LV; p=0.386). However, the number of patients with evidence of CMR-derived MVO (74.5% vs. 92.2%; p=0.017) and the extent of MVO (2.1%LV vs. 3.4%LV; p=0.025) were significantly reduced in the GP IIb/IIIa inhibitor group compared to controls. Thirty-day outcome showed an increased bleeding risk after GP IIb/IIIa inhibitor administration restricted to non-life-threatening bleedings (22.6% vs. 6.9%; p=0.016) without differences in all-cause mortality (4.8% vs. 3.4%; p=0.703). CONCLUSIONS: Bailout GP IIb/IIIa inhibition in AMI patients with angiographic MVO failed to reduce the primary endpoint infarct size but decreased CMR-derived MVO and led to an increase in non-fatal bleeding events.
RESUMO
OBJECTIVES: Right heart catheterization (RHC) is a common diagnostic tool and of special importance in the diagnosis of pulmonary hypertension (PH). Until today, there have been no clear instructions or guidelines on which venous access to prefer. This meta-analysis assessed whether the choice of the venous access site for elective RHC has an impact on procedural or clinical outcomes. METHODS: A structured literature search was performed. Single-arm reports and controlled trials reporting event data were eligible. The primary endpoint was a composite of access-related and overall complications. RESULTS: Nineteen studies, including 6509 RHC procedures, were eligible. The results were analyzed in two groups. The first group compared central venous access (CVA; n = 2072) with peripheral venous access (PVA; n = 2680) and included only multi-arm studies (n = 12, C/P comparison). In the second group, all studies (n = 19, threeway comparison) were assessed to compare the three individual access ways. The overall complication rate was low at 1.0% (n = 68). The primary endpoint in the C/P comparison occurred significantly less for PVA than for CVA (0.1% vs. 1.2%; p = 0.004). In the threeway comparison, PVA had a significantly lower complication rate than femoral access (0.3% vs. 1.1%; p = 0.04). Jugular access had the numerically highest complication rate (2.0%), but the difference was not significant compared to peripheral (0.3%; p = 0.29) or femoral access (1.1%; p = 0.32). CONCLUSION: This meta-analysis showed that PVA for RHC has a significantly lower complication rate than CVA. There was a low level of certainty and high heterogeneity. This pooled data analysis indicated PVA as the primary venous access for RHC.
RESUMO
Background: Besides transcatheter edge-to-edge repair (TEER), there are new interventional treatment options for mitral and tricuspid regurgitation in evaluation, such as a complete replacement of the valve through a prosthesis. Case summary: A 78-year-old previous coronary artery bypass graft-operated patient with symptomatic severe mitral regurgitation and tricuspid regurgitation was sequentially treated by a transfemoral transcatheter mitral and tricuspid valve prosthesis (Cardiovalve; Cardiovalve Ltd, Israel) due to unfavourable mitral valve anatomy. The transcatheter mitral valve implantation (TMVI) was performed first and after progression of the tricuspid regurgitation, a second transcatheter valve prosthesis was implanted in tricuspid position (TTVI) 1.5 years later. Imaging showed a twin look-alike picture of a mitral and tricuspid prosthesis and showing the possibility of a complete transcatheter based replacement of the mitral and tricuspid valve. Discussion: This case shows the possibility of a Cardiovalve prosthesis being used for TMVI and TTVI in a single patient. Especially in TEER ineligible patients, it might be a good treatment option after device approval.
RESUMO
BACKGROUND: There is a lack of comparative data on transcatheter aortic valve implantation (TAVI) in degenerated surgical prostheses (valve-in-valve [ViV]). AIMS: We sought to compare outcomes of using two self-expanding transcatheter heart valve (THV) systems for ViV. METHODS: In this retrospective multicentre registry, we included consecutive patients undergoing transfemoral ViV using either the ACURATE neo/neo2 (ACURATE group) or the Evolut R/PRO/PRO+ (EVOLUT group). The primary outcome measure was technical success according to Valve Academic Research Consortium (VARC)-3. Secondary outcomes were 30-day all-cause mortality, device success (VARC-3), coronary obstruction (CO) requiring intervention, rates of severe prosthesis-patient mismatch (PPM), and aortic regurgitation (AR) ≥moderate. Comparisons were made after 1:1 propensity score matching. RESULTS: The study cohort comprised 835 patients from 20 centres (ACURATE n=251; EVOLUT n=584). In the matched cohort (n=468), technical success (ACURATE 92.7% vs EVOLUT 88.9%; p=0.20) and device success (69.7% vs 73.9%; p=0.36) as well as 30-day mortality (2.8% vs 1.6%; p=0.392) were similar between the two groups. The mean gradients and rates of severe PPM, AR ≥moderate, or CO did not differ between the groups. Technical and device success were higher for the ACURATE platform among patients with a true inner diameter (ID) >19 mm, whereas a true ID ≤19 mm was associated with higher device success - but not technical success - among Evolut recipients. CONCLUSIONS: ViV TAVI using either ACURATE or Evolut THVs showed similar procedural outcomes. However, a true ID >19 mm was associated with higher device success among ACURATE recipients, whereas in patients with a true ID ≤19 mm, device success was higher when using Evolut.
Assuntos
Insuficiência da Valva Aórtica , Bioprótese , Oclusão Coronária , Substituição da Valva Aórtica Transcateter , Humanos , Catéteres , Insuficiência da Valva Aórtica/etiologia , Insuficiência da Valva Aórtica/cirurgia , Valvas Cardíacas , Sistema de Registros , Substituição da Valva Aórtica Transcateter/efeitos adversosRESUMO
BACKGROUND: In patients not suitable for transfemoral transcatheter aortic valve implantation (TAVI), several access strategies can be chosen. AIM: To evaluate the use and patient outcomes of transaxillary (TAx), transapical (TA), and transaortic (TAo) as alternative access for TAVI in Germany; to further evaluate surgical cutdown vs. percutaneous TAx access. METHODS: All patients entered the German Aortic Valve Registry (GARY) between 2011 and 2019 who underwent non-transfemoral TAVI were included in this analysis. Patients with TA, TAo, or TAx TAVI were compared using a weighted propensity score model. Furthermore, a subgroup analysis was performed for TAx regarding the percutaneous or surgical cutdown approach. RESULTS: Overall, 9686 patients received a non-transfemoral access. A total of 8918 patients (92.1%) underwent TA, 398 (4.1%) TAo, and 370 (3.8%) TAx approaches. Within the TAx subgroup, 141 patients (38.1%) received subclavian cutdown, while 200 (54.1%) underwent a percutaneous approach. The TA patients had a significantly lower 30-day survival than TAx patients (TA 90.92% vs. TAx 95.59%, p = 0.006; TAo 92.22% vs. TAx 95.59%, p = 0.102). Comparing percutaneous and cutdown TAx approaches, no significant differences were seen. However, more vascular complications occurred (TA 1.8%, TAo 2.4%, TAx 12.2%; p < .001), and the hospital length of stay was shorter (TA 12.9 days, TAo 14.1 days, TAx 12 days; p < .001) after TAx access. CONCLUSION: It may be reasonable to consider TAx access first in patients not suitable for TF-TAVI, because the 30-day survival was higher compared with TA access and the 1-year survival was higher compared with TAo access. It remains important for the heart teams to offer alternative access modalities for patients not amenable to the standard TF-TAVI approaches.
Assuntos
Implante de Prótese de Valva Cardíaca , Substituição da Valva Aórtica Transcateter , Insuficiência da Valva Tricúspide , Humanos , Valva Tricúspide/diagnóstico por imagem , Valva Tricúspide/cirurgia , Resultado do Tratamento , Implante de Prótese de Valva Cardíaca/efeitos adversos , Insuficiência da Valva Tricúspide/diagnóstico por imagem , Insuficiência da Valva Tricúspide/cirurgia , Cateterismo Cardíaco/efeitos adversosRESUMO
OBJECTIVES: The association of pulmonary hypertension (PH) with the outcome after mitral transcatheter edge-to-edge repair (M-TEER) focusing on the new ESC/ERS guidelines definition for PH. BACKGROUND: PH is frequently found in patients with mitral regurgitation and is associated with lower survival rates. Recent studies were based on echocardiographic parameters, but results based on invasive haemodynamics differentiating distinct types of PH using the new definition for PH are missing. METHODS: 449 consecutive M-TEER-treated patients from December 2009 to February 2015 were included in this retrospective analysis. All patients were stratified by the distinct types of PH (no PH, precapillary PH, isolated postcapillary PH, combined post-PH and precapillary PH) according to the definitions of the ESC/ERS guidelines for the diagnosis of PH from 2015 (meanPA cut-off <25 mm Hg, pulmonary capillary wedge pressure (PCWP) cut-off ≤15 mm Hg, diastolic pulmonary gradient cut-off ≥7 mm Hg or pulmonary vascular resistance (PVR) >3 WU) and 2022 (meanPA cut-off ≤20 mm Hg, PCWP cut-off ≤15 mm Hg, PVR cut-off ≥3 WU). RESULTS: Patients with any type of PH (2015: meanPA cut-off 25 mm Hg; 2022: meanPA cut-off >20 mm Hg) showed a higher risk of death after M-TEER compared with patients with no PH (2015: HR 1.61 (95% CI 1.25 to 2.07); p<0.001 and 2022: HR 2.09 (95% CI 1.54 to 2.83); p<0.001). Based on the new PH definition, each PH subgroup showed a lower survival after M-TEER compared with patients with no PH. Echocardiographic estimated systolic PAP showed a correlation with invasively measured mean pulmonary artery pressure (mPAP) (r=0.29, p<0.001) and systolic pulmonary arterial pressure (r=0.34,p<0.001). Cox-regression analysis showed higher invasive diastolic, systolic and mean pulmonary pressures were associated with higher all-cause mortality (p<0.001). In addition, invasive measured higher right atrial pressure, lower pulmonary arterial compliance, higher PVR and higher wedge pressure were identified as predictors of all-cause mortality after M-TEER. CONCLUSIONS: The new PH definition discriminates PH groups and mortality better than the old definition. The lower threshold of mPAP of 20mmHg improved prognostication in this cohort of patients.
Assuntos
Cateterismo Cardíaco , Hipertensão Pulmonar , Insuficiência da Valva Mitral , Humanos , Hipertensão Pulmonar/fisiopatologia , Hipertensão Pulmonar/mortalidade , Hipertensão Pulmonar/diagnóstico , Feminino , Masculino , Estudos Retrospectivos , Insuficiência da Valva Mitral/cirurgia , Insuficiência da Valva Mitral/fisiopatologia , Insuficiência da Valva Mitral/mortalidade , Insuficiência da Valva Mitral/diagnóstico , Insuficiência da Valva Mitral/complicações , Idoso , Cateterismo Cardíaco/métodos , Resultado do Tratamento , Valva Mitral/diagnóstico por imagem , Valva Mitral/fisiopatologia , Valva Mitral/cirurgia , Pressão Propulsora Pulmonar/fisiologia , Pessoa de Meia-Idade , Fatores de Risco , Hemodinâmica/fisiologiaRESUMO
BACKGROUND: Various second-generation transcatheter heart valve (THV) prostheses with high clinical efficacy and safety are available, but there is limited large-scale data available comparing their hemodynamic performance and clinical implications. OBJECTIVE: To compare the hemodynamic performance and short-term clinical outcome of four second-generation THV prostheses. METHODS: 24,124 patients out of the German Aortic Valve Registry who underwent transfemoral transcatheter aortic valve implantation (TAVI) (Evolut™ R n = 7028, Acurate neo™ n = 2922, Portico n = 878 and Sapien 3 n = 13,296) were included in this analysis. Propensity-score weighted analysis was performed to control for differences in age, left ventricular function, STS score and sex. Primary endpoint was survival at one-year, secondary endpoints were 30 days survival, pre-discharge transvalvular gradients, paravalvular leakage and peri-procedural complications. RESULTS: Thirty-day and one-year survival were not significantly different between the four patient groups. Transvalvular gradients in Evolut™ R and Acurate neo™ were significantly lower as compared to Portico and Sapien 3 at hospital discharge. This difference exists across all annulus sizes. Paravalvular leakage ≥ II occurred significantly less often in the Sapien 3 group (1.2%, p < 0.0001). Rate of severe procedural complications was low and comparable in all groups. Permanent pacemaker implantation rate at one year was lowest in the ACUARATE neo group (13.0%) and highest in the Evolut™ R group (21.9%). CONCLUSION: Albeit comparable short-term clinical outcomes there are certain differences regarding hemodynamic performance and permanent pacemaker implantation rate between currently available THV prostheses which should be considered for individual prosthesis selection.
Assuntos
Estenose da Valva Aórtica , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Humanos , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/cirurgia , Desenho de Prótese , Resultado do Tratamento , Sistema de RegistrosRESUMO
BACKGROUND: Aortic valve (AV) repair is an evolving surgical strategy in the treatment of nonelderly adults with aortic regurgitation. We aimed to determine the 1-year outcome after AV repair vs surgical AV replacement (sAVR) using real-world data from the German Aortic Valve Registry. METHODS: A total of 8076 aortic regurgitation patients (mean age, 59.1 ± 15.0 years; 76% men; mean The Society of Thoracic Surgeons score, 1.3 ± 1.1), who underwent AV surgical procedures between 2011 and 2015, were identified from German Aortic Valve Registry. The AV was repaired in 2327 patients (29%), and the remaining 5749 patients (71%) underwent sAVR. A weighted propensity score model, including the variables of age, sex, and The Society of Thoracic Surgeons score, was used to correct for baseline differences between AV repair and sAVR cohorts. The primary end point was 1-year survival after AV repair vs sAVR. Secondary end points were freedom from cardiac events and AV reinterventions. RESULTS: Survival at 1 year was 97.7% (95% CI, 97.0%-98.5%) in the AV repair cohort vs 96.4% (95% CI, 95.9%-96.9%) in the propensity score-weighted sAVR cohort (log-rank P < .001). Cox regression revealed a significant advantage of AV repair vs sAVR (hazard ratio, 0.68; 95% CI, 0.51-0.90; P < .0001) on 1-year survival, which was independent of age. Cardiac event-free survival at 1 year was 85.7% (95% CI, 483.8%-87.7%) in the AV repair group vs 81.7% (95% CI, 80.7%-82.9%) in the sAVR group (log-rank P < .001). AV reintervention was required in 38 AV repair patients (1.6%) compared with 1.6% in the sAVR cohort (P = .59). CONCLUSIONS: AV repair surgery, whenever intraoperatively feasible, is associated with a significantly better 1-year survival and 1-year cardiac event-free survival compared with sAVR.
Assuntos
Insuficiência da Valva Aórtica , Estenose da Valva Aórtica , Implante de Prótese de Valva Cardíaca , Substituição da Valva Aórtica Transcateter , Masculino , Humanos , Adulto , Pessoa de Meia-Idade , Idoso , Feminino , Valva Aórtica/cirurgia , Substituição da Valva Aórtica Transcateter/métodos , Implante de Prótese de Valva Cardíaca/métodos , Insuficiência da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/cirurgia , Resultado do Tratamento , Fatores de Risco , Sistema de RegistrosRESUMO
Tricuspid transcatheter edge-to-edge repair (T-TEER) for severe tricuspid regurgitation (TR) emerged as a novel treatment option for patients not amenable to surgery. However, knowledge regarding independent risk factors for a worse prognosis is rarely available. The study sought to investigate the impact of right ventricular cardiac power index (RVCPi) on 1-year outcomes in patients with severe symptomatic TR who underwent T-TEER. Consecutive patients with severe TR who underwent T-TEER from August 2020 to March 2022 were included and followed prospectively. Baseline clinical and invasive hemodynamic variables, changes in echocardiographic parameters and New York Heart Association functional class, and periprocedural and in-hospital major adverse events were assessed. Primary end point was defined as a composite of all-cause mortality and heart failure hospitalization at 1 year after T-TEER. A multivariable Cox proportional-hazards regression analysis was performed to identify independent risk factors for combined primary end point. RVCPi was calculated as: (cardiac index × mean pulmonary pressure) × K (conversion factor 2.22 × 10-3) = W/m². Receiver operator characteristic analysis was used to determine discriminative capacity of RVCPi. The prognostic value of RVCPi threshold was tested using Kaplan-Meier analysis. In total, 102 patients (mean age 81 ± 6 years, 51% women) at high operative risk underwent T-TEER for severe TR. Primary end point occurred in 30 patients (32%). Receiver operator characteristic curve analysis demonstrated that RVCPi was associated with an area under the curve of 0.69 (95% confidence interval 0.56 to 0.82; p = 0.003). With a RVCPi threshold of 0.17 W/m² (maximally selected rank statistics), the event-free survival was significantly higher in the RVCPi <0.17 W/m² group compared with those with RVCPi ≥0.17 W/m² (71% vs 35%, log-rank p <0.001). In the multivariable Cox regression analysis, RVCPi was an independent predictor for the combined primary end point (hazard ratio 2.6, 95% confidence interval 1.4 to 5.1, p = 0.003). In conclusion, RVCPi is associated with outcome in patients who underwent T-TEER for severe TR and this hemodynamic predictor is useful in risk stratification of T-TEER candidates.
Assuntos
Implante de Prótese de Valva Cardíaca , Insuficiência da Valva Tricúspide , Humanos , Feminino , Idoso , Idoso de 80 Anos ou mais , Masculino , Valva Tricúspide/diagnóstico por imagem , Valva Tricúspide/cirurgia , Resultado do Tratamento , Implante de Prótese de Valva Cardíaca/efeitos adversos , Cateterismo Cardíaco/efeitos adversosRESUMO
BACKGROUND: The exact incidence and predictors of new-onset atrial fibrillation (AF) after percutaneous closure of patent foramen ovale (PFO) are unknown. OBJECTIVE: We sought to find post-procedural AF incidence rates and differences due to different screening strategies and devices. METHODS: A systematic search was conducted in Cochrane, MEDLINE and EMBASE. Controlled trials fulfilling the inclusion criteria were included into this meta-analysis. The incidence of new-onset AF was the primary outcome. Further parameters were surveillance strategy, device type, AF treatment and neurological events. New AF was determined as early onset within one month after implantation and late thereafter. RESULTS: 8 controlled trials and 16 cohort studies were eligible for quantitative analysis. 7643 patients received percutaneous PFO closure after cryptogenic stroke or transient ischaemic attack, 117 with other indications, whereas 1792 patients formed the control group. Meta-analysis of controlled trials showed an AF incidence of 5.1% in the interventional and 1.6% in the conservative arm, respectively (OR 3.17, 95% CI 1.46-6.86, P = 0.03, I2 = 55%). 4.7% received high-quality surveillance strategy with Holter-ECG or Loop recorder whereby AF incidence was overall higher compared to the low-quality group with 12-lead ECG only (3.3-15% vs. 0.2-4.3%). Heterogeneous results on time of AF onset were found, limited by different follow-up strategies. CardioSEAL and Starflex seemed to have higher AF incidences in early and late onset with 4.5% and 4.2%, respectively. CONCLUSION: Percutaneous PFO closure led to higher AF post-procedural incidence compared to the conservative strategy. Heterogeneity in surveillance and follow-up strategy limited the generalizability. TRIAL REGISTRATION: Registered on PROSPERO (CRD42022359945).
Assuntos
Fibrilação Atrial , Forame Oval Patente , Ataque Isquêmico Transitório , AVC Isquêmico , Dispositivo para Oclusão Septal , Acidente Vascular Cerebral , Humanos , Acidente Vascular Cerebral/epidemiologia , Acidente Vascular Cerebral/etiologia , Acidente Vascular Cerebral/prevenção & controle , Forame Oval Patente/complicações , Forame Oval Patente/diagnóstico , Forame Oval Patente/epidemiologia , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/epidemiologia , Fibrilação Atrial/complicações , Prevenção Secundária/métodos , Resultado do Tratamento , Cateterismo Cardíaco/efeitos adversos , Dispositivo para Oclusão Septal/efeitos adversosRESUMO
OBJECTIVE: After transcatheter aortic valve implantation (TAVI), the optimal regimen of anticoagulant therapy in patients with an additional indication for oral anticoagulation remains a matter of debate. This study investigates the efficacy of direct oral anticoagulants (DOACs) versus vitamin K antagonists (VKAs) in patients after TAVI in a real-world population. METHODS: The German Aortic Valve RegistrY (GARY) is a prospective, multicentre registry enrolling patients undergoing invasive treatment for aortic valve disease. From January 2011 to December 2019, 1 41 790 patients from 92 hospitals in Germany were enrolled. Anticoagulatory treatment regimens were assessed at hospital discharge for patients after TAVI procedures. All-cause mortality and the combined endpoint 'cardiac and cerebrovascular events' containing myocardial infarction, stroke, transient ischaemic attack, aortic prosthesis reintervention and all-cause mortality in the first year after TAVI were examined by treatment regimen. RESULTS: Of 45 598 patients (mean age 80.7±5.7 years, 49.3% males) undergoing TAVI, 16 974 patients (37.2%) received an anticoagulant regimen that included VKA or DOAC. Hereof, the majority of patients were prescribed VKA (n=11 333, 66.8%) compared with DOAC (n=5641, 33.2%) with an increase of DOAC use from 9.4% in 2011 to 69.9% in 2019. During the 1-year follow-up, the absolute event rates per 100 person-years for all-cause mortality and the combined endpoint cardiac and cerebrovascular events were 1.9 and 1.3 for VKA-treated and 1.7 and 1.2 for DOAC-treated patients, respectively. After adjustment for baseline confounders, all-cause mortality (HR 0.95, 95% CI 0.88 to 1.01, p=0.114) and cardiac and cerebrovascular event-free survival (HR 0.93, 95% CI 0.86 to 1.01, p=0.071) did not differ significantly between VKA and DOAC groups. CONCLUSIONS: This study supports evidence of the efficacy of DOAC use after TAVI in patients with an indication for oral anticoagulation.
Assuntos
Estenose da Valva Aórtica , Substituição da Valva Aórtica Transcateter , Masculino , Humanos , Idoso , Idoso de 80 Anos ou mais , Feminino , Substituição da Valva Aórtica Transcateter/efeitos adversos , Estudos Prospectivos , Anticoagulantes/efeitos adversos , Valva Aórtica/cirurgia , Fibrinolíticos , Vitamina K , Resultado do Tratamento , Fatores de RiscoRESUMO
Aims: Identification of high-risk patients and individualized decision support based on objective criteria for rapid discharge after transcatheter aortic valve implantation (TAVI) are key requirements in the context of contemporary TAVI treatment. This study aimed to predict 30-day mortality following TAVI based on machine learning (ML) using data from the German Aortic Valve Registry. Methods and results: Mortality risk was determined using a random forest ML model that was condensed in the newly developed TAVI Risk Machine (TRIM) scores, designed to represent clinically meaningful risk modelling before (TRIMpre) and in particular after (TRIMpost) TAVI. Algorithm was trained and cross-validated on data of 22 283 patients (729 died within 30 days post-TAVI) and generalisation was examined on data of 5864 patients (146 died). TRIMpost demonstrated significantly better performance than traditional scores [C-statistics value, 0.79; 95% confidence interval (CI)] [0.74; 0.83] compared to Society of Thoracic Surgeons (STS) with C-statistics value 0.69; 95%-CI [0.65; 0.74]). An abridged (aTRIMpost) score comprising 25 features (calculated using a web interface) exhibited significantly higher performance than traditional scores (C-statistics value, 0.74; 95%-CI [0.70; 0.78]). Validation on external data of 6693 patients (205 died within 30 days post-TAVI) of the Swiss TAVI Registry confirmed significantly better performance for the TRIMpost (C-statistics value 0.75, 95%-CI [0.72; 0.79]) compared to STS (C-statistics value 0.67, CI [0.63; 0.70]). Conclusion: TRIM scores demonstrate good performance for risk estimation before and after TAVI. Together with clinical judgement, they may support standardised and objective decision-making before and after TAVI.
RESUMO
BACKGROUND: Takotsubo syndrome (TTS) is a reversible form of heart failure with incompletely understood pathophysiology. OBJECTIVES: This study analyzed altered cardiac hemodynamics during TTS to elucidate underlying disease mechanisms. METHODS: Left ventricular (LV) pressure-volume loops were recorded in 24 consecutive patients with TTS and a control population of 20 participants without cardiovascular diseases. RESULTS: TTS was associated with impaired LV contractility (end-systolic elastance 1.74 mm Hg/mL vs 2.35 mm Hg/mL [P = 0.024]; maximal rate of change in systolic pressure over time 1,533 mm Hg/s vs 1,763 mm Hg/s [P = 0.031]; end-systolic volume at a pressure of 150 mm Hg, 77.3 mL vs 46.4 mL [P = 0.002]); and a shortened systolic period (286 ms vs 343 ms [P < 0.001]). In response, the pressure-volume diagram was shifted rightward with significantly increased LV end-diastolic (P = 0.031) and end-systolic (P < 0.001) volumes, which preserved LV stroke volume (P = 0.370) despite a lower LV ejection fraction (P < 0.001). Diastolic function was characterized by prolonged active relaxation (relaxation constant 69.5 ms vs 45.9 ms [P < 0.001]; minimal rate of change in diastolic pressure -1,457 mm Hg/s vs -2,192 mm Hg/s [P < 0.001]), whereas diastolic stiffness (1/compliance) was not affected during TTS (end-diastolic volume at a pressure of 15 mm Hg, 96.7 mL vs 109.0 mL [P = 0.942]). Mechanical efficiency was significantly reduced in TTS (P < 0.001) considering reduced stroke work (P = 0.001), increased potential energy (P = 0.036), and a similar total pressure-volume area compared with that of control subjects (P = 0.357). CONCLUSIONS: TTS is characterized by reduced cardiac contractility, a shortened systolic period, inefficient energetics, and prolonged active relaxation but unaltered diastolic passive stiffness. These findings may suggest decreased phosphorylation of myofilament proteins, which represents a potential therapeutic target in TTS. (Optimized Characterization of Takotsubo Syndrome by Obtaining Pressure Volume Loops [OCTOPUS]; NCT03726528).
Assuntos
Cardiomiopatia de Takotsubo , Humanos , Cardiomiopatia de Takotsubo/diagnóstico , Hemodinâmica , Função Ventricular Esquerda/fisiologia , Volume Sistólico/fisiologia , Contração Miocárdica/fisiologiaRESUMO
BACKGROUND: Data regarding the impact of the tricuspid valve gradient (TVG) after tricuspid transcatheter edge-to-edge repair (TEER) are scarce. OBJECTIVES: This study sought to evaluate the association between the mean TVG and clinical outcomes among patients who underwent tricuspid TEER for significant tricuspid regurgitation. METHODS: Patients with significant tricuspid regurgitation who underwent tricuspid TEER within the TriValve (International Multisite Transcatheter Tricuspid Valve Therapies) registry were divided into quartiles based on the mean TVG at discharge. The primary endpoint was the composite of all-cause mortality and heart failure hospitalization. Outcomes were assessed up to the 1-year follow-up. RESULTS: A total of 308 patients were included from 24 centers. Patients were divided into quartiles of the mean TVG as follows: quartile 1 (n = 77), 0.9 ± 0.3 mm Hg; quartile 2 (n = 115), 1.8 ± 0.3 mm Hg; quartile 3 (n = 65), 2.8 ± 0.3 mm Hg; and quartile 4 (n = 51), 4.7 ± 2.0 mm Hg. The baseline TVG and the number of implanted clips were associated with a higher post-TEER TVG. There was no significant difference across TVG quartiles in the 1-year composite endpoint (quartiles 1-4: 35%, 30%, 40%, and 34%, respectively; P = 0.60) or the proportion of patients in New York Heart Association class III to IV at the last follow-up (P = 0.63). The results were similar after adjustment for clinical and echocardiographic characteristics (composite endpoint quartile 4 vs quartile 1-quartile 3 adjusted HR: 1.05; 95% CI: 0.52-2.12; P = 0.88) or exploring post-TEER TVG as a continuous variable. CONCLUSIONS: In this retrospective analysis of the TriValve registry, an increased discharge TVG was not significantly associated with adverse outcomes after tricuspid TEER. These findings apply for the explored TVG range and up to the 1-year follow-up. Further investigations on higher gradients and longer follow-up are needed to better guide the intraprocedural decision-making process.
RESUMO
BACKGROUND: Residual mitral regurgitation (MR) is thought to be an important predictor of long-term survival following transcatheter edge-to-edge repair (TEER). Intraprocedural MR assessment using transesophageal echocardiography could be limited by image quality, hemodynamics, and patient sedation. The MitraScore is a validated multimodal approach for intraprocedural MR assessment during TEER. OBJECTIVES: This study aimed to assess the impact of residual MR using the MitraScore on 1-year mortality. METHODS: Patients undergoing mitral TEER were eligible for inclusion in the prospective, multicenter MITRA-PRO registry (A Prospective Registry Study on 1-Year Mortality and the Prognostic Significance of MitraScore After MitraClip Implantation in Patients With Mitral Regurgitation). Patients with a MitraScore ≤3 were defined as patients with mild residual MR after mitral TEER, whereas a MitraScore ≥4 was considered as relevant residual MR. Mortality, rehospitalization, and major adverse events were assessed 1 year after TEER. RESULTS: A MitraScore ≤3 was found in 1,059 patients (71.0%), whereas 432 patients revealed a MitraScore ≥4 (29.0%). One-year mortality was significantly lower in patients with nonrelevant residual MR (MitraScore ≤3 14.6% vs MitraScore≥4 22.1%). An almost linear relationship between intraprocedural MitraScore after TEER and mortality was observed. The combined clinical endpoint of mortality and rehospitalization within the 1-year follow-up was also significantly lower in the MitraScore ≤3 group (31.5%) than in the MitraScore ≥4 group (40.8%). A subgroup analysis confirmed the predictive value of the MitraScore in patients with primary, secondary, or mixed MR etiologies. CONCLUSIONS: Residual MR assessed by intraprocedural MitraScore after TEER predicts 1-year mortality and rehospitalization. Therefore, the multimodal MitraScore improves MR assessment during mitral TEER and might improve patient survival.(A Prospective Registry Study on 1-Year Mortality and the Prognostic Significance of MitraScore After MitraClip Implantation in Patients With Mitral Regurgitation [MITRA-PRO]; DRKS00012288).
Assuntos
Implante de Prótese de Valva Cardíaca , Insuficiência da Valva Mitral , Humanos , Insuficiência da Valva Mitral/diagnóstico por imagem , Insuficiência da Valva Mitral/cirurgia , Insuficiência da Valva Mitral/etiologia , Valva Mitral/diagnóstico por imagem , Valva Mitral/cirurgia , Resultado do Tratamento , Sistema de Registros , Cateterismo Cardíaco/métodosRESUMO
BACKGROUND: The need for permanent pacemaker (PPM) implantation is a common complication after transcatheter aortic valve replacement (TAVR). Deep implantation position is a risk factor for PPM implantation. Thus, in the field of self-expandable (SE) transcatheter heart valves (THV) cusp overlap projection (COP) technique was implemented to reduce parallax, allowing a more precise guidance of implantation depth. AIMS: This meta-analysis aims to report the outcome of patients undergoing TAVR with SE THV using COP versus conventional implantation technique (CIT). METHODS: Systematical search in MEDLINE and EMBASE yielded five observational controlled studies comparing both implantation techniques for the SE Evolut prosthesis (Medtronic Intern. Ltd., CA, USA) and fulfilling the inclusion criteria for meta-analysis. RESULTS: Totally, 1227 patients were included, comprising 641 who underwent COP and 586 CIT TAVR. Incidence of post-procedural need for PPM implantation was significantly lower in COP group (9.8% vs 20.6%; OR = 0.43; p < 0.00001). This was accompanied by significantly higher implantation position in COP group (mean difference distance from distal end of the intraventricular portion of the THV to the non-coronary cusp (NCC): - 1.03 mm; p = 0.00001). Incidence of new-onset left bundle branch block did not differ. Regarding procedural and 30-day mortality, technical success, post-procedural aortic regurgitation, and rates of multiple device implantation, no difference between COP and CIT was found. CONCLUSION: COP is an effective and safe implantation technique to reduce the need for a permanent pacemaker implantation during TAVR with SE Evolut prosthesis.
Assuntos
Estenose da Valva Aórtica , Próteses Valvulares Cardíacas , Marca-Passo Artificial , Substituição da Valva Aórtica Transcateter , Humanos , Estenose da Valva Aórtica/cirurgia , Resultado do Tratamento , Próteses Valvulares Cardíacas/efeitos adversos , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Fatores de Risco , Desenho de PróteseRESUMO
AIMS: The impact of sexuality in patients with significant tricuspid regurgitation (TR) undergoing transcatheter tricuspid valve intervention (TTVI) is unknown. The aim of this study was to investigate sex-specific outcomes in patients with significant TR treated with TTVI vs. medical therapy alone. METHODS AND RESULTS: The Transcatheter Tricuspid Valve Therapies (TriValve) registry collected data on patients with significant TR from 24 centres who underwent TTVI from 2016 to 2021. A control cohort was formed by medically managed patients with ≥severe isolated TR diagnosed in 2015-18. The primary endpoint was freedom from all-cause mortality. Secondary endpoints were heart failure (HF) hospitalization, New York Heart Association (NYHA) functional status, and TR severity. One-year outcomes were assessed for the TriValve cohort and compared with the control cohort with the inverse probability of treatment weighting (IPTW). A total of 556 and 2072 patients were included from the TriValve and control groups, respectively. After TTVI, there was no difference between women and men in 1-year freedom from all-cause mortality 80.9% vs. 77.9%, P = 0.56, nor in HF hospitalization (P = 0.36), NYHA Functional Classes III and IV (P = 0.17), and TR severity >2+ at last follow-up (P = 0.42). Multivariable Cox-regression weighted by IPTW showed improved 1-year survival after TTVI compared with medical therapy alone in both women (adjusted hazard ratio 0.45, 95% confidence interval 0.23-0.83, P = 0.01) and men (adjusted hazard ratio 0.42, 95% confidence interval 0.18-0.89, P = 0.03). CONCLUSION: After TTVI in high-risk patients, there were no sex-related differences in terms of survival, HF hospitalization, functional status, and TR reduction up to 1 year. The IPTW analysis shows a survival benefit of TTVI over medical therapy alone in both women and men.