J Biophotonics ; 13(6): e201960196, 2020 06.
Artigo em Inglês | MEDLINE | ID: mdl-32057188

RESUMO

Compression optical coherence elastography (OCE) typically requires a mechanical actuator to impart a controlled uniform strain to the sample. However, for handheld scanning, this adds complexity to the design of the probe and the actuator stroke limits the amount of strain that can be applied. In this work, we present a new volumetric imaging approach that utilizes bidirectional manual compression via the natural motion of the user's hand to induce strain to the sample, realizing compact, actuator-free, handheld compression OCE. In this way, we are able to demonstrate rapid acquisition of three-dimensional quantitative microelastography (QME) datasets of a tissue volume (6 × 6 × 1 mm3 ) in 3.4 seconds. We characterize the elasticity sensitivity of this freehand manual compression approach using a homogeneous silicone phantom and demonstrate comparable performance to a benchtop mounted, actuator-based approach. In addition, we demonstrate handheld volumetric manual compression-based QME on a tissue-mimicking phantom with an embedded stiff inclusion and on freshly excised human breast specimens from both mastectomy and wide local excision (WLE) surgeries. Tissue results are coregistered with postoperative histology, verifying the capability of our approach to measure the elasticity of tissue and to distinguish stiff tumor from surrounding soft benign tissue.


Assuntos
Neoplasias da Mama , Técnicas de Imagem por Elasticidade , Feminino , Humanos , Mastectomia , Imagens de Fantasmas , Tomografia de Coerência Óptica
2.
Biomed Opt Express ; 10(8): 4034-4049, 2019 Aug 01.
Artigo em Inglês | MEDLINE | ID: mdl-31452993

RESUMO

Optical coherence elastography (OCE) has been proposed for a range of clinical applications. However, the majority of these studies have been performed using bulky, lab-based imaging systems. A compact, handheld imaging probe would accelerate clinical translation, however, to date, this had been inhibited by the slow scan rates of compact devices and the motion artifact induced by the user's hand. In this paper, we present a proof-of-concept, handheld quantitative micro-elastography (QME) probe capable of scanning a 6 × 6 × 1 mm volume of tissue in 3.4 seconds. This handheld probe is enabled by a novel QME acquisition protocol that incorporates a custom bidirectional scan pattern driving a microelectromechanical system (MEMS) scanner, synchronized with the sample deformation induced by an annular PZT actuator. The custom scan pattern reduces the total acquisition time and the time difference between B-scans used to generate displacement maps, minimizing the impact of motion artifact. We test the feasibility of the handheld QME probe on a tissue-mimicking silicone phantom, demonstrating comparable image quality to a bench-mounted setup. In addition, we present the first handheld QME scans performed on human breast tissue specimens. For each specimen, quantitative micro-elastograms are co-registered with, and validated by, histology, demonstrating the ability to distinguish stiff cancerous tissue from surrounding soft benign tissue.

3.
Opt Lett ; 42(7): 1233-1236, 2017 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-28362737

RESUMO

Depth-encoded optical coherence elastography (OCE) enables simultaneous acquisition of two three-dimensional (3D) elastograms from opposite sides of a sample. By the choice of suitable path-length differences in each of two interferometers, the detected carrier frequencies are separated, allowing depth-ranging from each interferometer to be performed simultaneously using a single spectrometer. We demonstrate depth-encoded OCE on a silicone phantom and a freshly excised sample of mouse liver. This technique minimizes the required spectral detection hardware and halves the total scan time. Depth-encoded OCE may expedite clinical translation in time-sensitive applications requiring rapid 3D imaging of multiple tissue surfaces, such as tumor margin assessment in breast-conserving surgery.


Assuntos
Imageamento Tridimensional/métodos , Tomografia de Coerência Óptica/métodos , Animais , Técnicas de Imagem por Elasticidade , Fígado/citologia , Fígado/diagnóstico por imagem , Camundongos , Imagens de Fantasmas , Fatores de Tempo