Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 53
Filtrar
2.
EClinicalMedicine ; 62: 102114, 2023 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-37560257

RESUMO

The concept of primary healthcare is now regarded as crucial for enhancing access to healthcare services in low-income and middle-income countries (LMICs). Technological advancements that have made many medical imaging devices smaller, lighter, portable and more affordable, and infrastructure advancements in power supply, Internet connectivity, and artificial intelligence, are all increasing the feasibility of POCI (point-of care imaging) in LMICs. Although providing imaging services at the same time as the clinic visit represents a paradigm shift in the way imaging care is typically provided in high-income countries where patients are typically directed to dedicated imaging centres, a POCI model is often the only way to provide timely access to imaging care for many patients in LIMCs. To address the growing burden of non-communicable diseases such as cancer and heart disease, bringing advanced imaging tools to the POCI will be necessary. Strategies tailored to the countries' specific needs, including training, safety and quality, will be of the utmost importance.

3.
PLoS One ; 18(7): e0288359, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37498898

RESUMO

OBJECTIVE: To describe a methodological approach to explore the concordance of recommendations across guidelines and its application to the case of the WHO recommendations on chest imaging for the diagnosis and management of COVID-19. STUDY DESIGN AND SETTING: We followed a methodological approach applied to a case study that included: defining the 'reference guideline' (i.e., the WHO guidance) and the 'reference recommendations'; searching for 'related guidelines' and identifying 'related recommendations'; constructing the PICO for the recommendations; assessing the matching of the PICO of each related recommendation to the PICO corresponding reference recommendation; and assessing the concordance between the PICO-matching recommendations. RESULTS: We identified a total of 89 related recommendations from 22 related guidelines. Out of the 89 related recommendations, 43 partly matched and 1 entirely matched one of the reference recommendations, and out of these, 8 were concordant with one of the reference recommendations. When considering the seven reference recommendations, they had a median of 12 related recommendations (range 3-17), a median of 7 PICO-matching recommendations (range 0-13), and a median of 1 concordant recommendation (range 0-4). CONCLUSION: Following a detailed methodological approach, we were able to explore the concordance between our reference recommendations and related recommendations from other guidelines. A relatively low percentage of recommendations was concordant.


Assuntos
COVID-19 , Humanos , COVID-19/diagnóstico por imagem , Diagnóstico por Imagem , Teste para COVID-19
4.
Insights Imaging ; 14(1): 108, 2023 Jun 19.
Artigo em Inglês | MEDLINE | ID: mdl-37336849

RESUMO

OBJECTIVES: Contact shielding (CS) of patients during X-ray studies has been used for decades to protect radiosensitive organs. This practice has not changed much despite increasing evidence that CS is not useful in many cases. The Gonad And Patient Shielding (GAPS) group-founded by representatives of the main European bodies involved in radiology-promoted this survey to assess the current practice of CS among European radiology departments and the attitude towards a non-shielding policy. METHODS: Over a four-month period (15 May-15th September 2021) European Society of Radiology and European Society of Paediatric Radiology radiologist members were invited to respond to a web-based questionnaire consisting of 59 questions. RESULTS: 225 centres from 35 countries responded to this survey. CS was routinely applied in at least one radiological modality in 49.2% of centres performing studies in adults, 57.5% of centres performing studies in children, and 47.8% of centres performing studies on pregnant women. CS was most frequently used in conventional radiography, where the most frequently shielded organs were the gonads, followed by thyroid, female breasts, and eye lens. 83.6% respondents would follow European recommendations on the use of CS when provided by the main European bodies involved in radiology. CONCLUSIONS: This review shows that CS is still largely used across Europe. However, a non-shielding policy could be adopted in most departments if European professional societies provided recommendations. In this regard, a strong commitment by European and national professional societies to educate and inform practitioners, patients and carers is paramount. CLINICAL RELEVANCE STATEMENT: According to this survey expectations of patients and carers, and skepticism among professionals about the limited benefits of CS are the most important obstacles to the application of a no-shielding policy. A strong commitment from European and national professional societies to inform practitioners, patients and carers is fundamental.

5.
Insights Imaging ; 14(1): 55, 2023 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-37005914

RESUMO

PURPOSE: To analyse the existing radiation protection (RP) education and training (E&T) capabilities in the European Union and identify associated needs, problems and challenges. METHOD: An online survey was disseminated via the EURAMED Rocc-n-Roll consortium network and prominent medical societies in the field of radiological research. The survey sections analyse the RP E&T during undergraduate, residency/internship and continuous professional development; RP E&T problems and legal implementation. Differences were analysed by European geographic regions, profession, years of professional experience and main area of practice/research. RESULTS: The majority of the 550 respondents indicated that RP topics are part of undergraduate curricula in all courses for their profession and country (55%); however, hands-on practical training is not included according to 30% of the respondents. The lack of E&T, practical aspects in current E&T, and mandatory continuing E&T were considered the major problems. The legal requirement that obtained higher implementation score was the inclusion of the practical aspects of medical radiological procedures on education (86%), and lower score was obtained for the inclusion of RP E&T on medical and dental school curriculums (61%). CONCLUSIONS: A heterogeneity in RP E&T during undergraduate, residency/internship and continuous professional development is evident across Europe. Differences were noted per area of practice/research, profession, and European geographic region. A large variation in RP E&T problem rating was also obtained.

7.
ERJ Open Res ; 9(1)2023 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-36628270

RESUMO

This review article addresses the role of lung ultrasound in patients with coronavirus disease 2019 (COVID-19) for diagnosis and disease management. As a simple imaging procedure, lung ultrasound contributes to the early identification of patients with clinical conditions suggestive of COVID-19, supports decisions about hospital admission and informs therapeutic strategy. It can be performed in various clinical settings (primary care facilities, emergency departments, hospital wards, intensive care units), but also in outpatient settings using portable devices. The article describes typical lung ultrasound findings for COVID-19 pneumonia (interstitial pattern, pleural abnormalities and consolidations), as one component of COVID-19 diagnostic workup that otherwise includes clinical and laboratory evaluation. Advantages and limitations of lung ultrasound use in COVID-19 are described, along with equipment requirements and training needs. To infer on the use of lung ultrasound in different regions, a literature search was performed using key words "COVID-19", "lung ultrasound" and "imaging". Lung ultrasound is a noninvasive, rapid and reproducible procedure; can be performed at the point of care; requires simple sterilisation; and involves non-ionising radiation, allowing repeated exams on the same patient, with special benefit in children and pregnant women. However, physical proximity between the patient and the ultrasound operator is a limitation in the current pandemic context, emphasising the need to implement specific infection prevention and control measures. Availability of qualified staff adequately trained to perform lung ultrasound remains a major barrier to lung ultrasound utilisation. Training, advocacy and awareness rising can help build up capacities of local providers to facilitate lung ultrasound use for COVID-19 management, in particular in low- and middle-income countries.

8.
J Am Coll Radiol ; 20(2): 251-264, 2023 02.
Artigo em Inglês | MEDLINE | ID: mdl-36130692

RESUMO

US physicians in multiple specialties who order or conduct radiological procedures lack formal radiation science education and thus sometimes order procedures of limited benefit or fail to order what is necessary. To this end, a multidisciplinary expert group proposed an introductory broad-based radiation science educational program for US medical schools. Suggested preclinical elements of the curriculum include foundational education on ionizing and nonionizing radiation (eg, definitions, dose metrics, and risk measures) and short- and long-term radiation-related health effects as well as introduction to radiology, radiation therapy, and radiation protection concepts. Recommended clinical elements of the curriculum would impart knowledge and practical experience in radiology, fluoroscopically guided procedures, nuclear medicine, radiation oncology, and identification of patient subgroups requiring special considerations when selecting specific ionizing or nonionizing diagnostic or therapeutic radiation procedures. Critical components of the clinical program would also include educational material and direct experience with patient-centered communication on benefits of, risks of, and shared decision making about ionizing and nonionizing radiation procedures and on health effects and safety requirements for environmental and occupational exposure to ionizing and nonionizing radiation. Overarching is the introduction to evidence-based guidelines for procedures that maximize clinical benefit while limiting unnecessary risk. The content would be further developed, directed, and integrated within the curriculum by local faculties and would address multiple standard elements of the Liaison Committee on Medical Education and Core Entrustable Professional Activities for Entering Residency of the Association of American Medical Colleges.


Assuntos
Proteção Radiológica , Radiologia , Humanos , Faculdades de Medicina , Multimídia , Radiologia/educação , Currículo
9.
Insights Imaging ; 13(1): 142, 2022 Sep 04.
Artigo em Inglês | MEDLINE | ID: mdl-36057698

RESUMO

BACKGROUND: A Strengths, weaknesses, opportunities and threats analysis was performed to understand the status quo of education and training in radiation protection (RP) and to develop a coordinated European approach to RP training needs based on stakeholder consensus and existing activities in the field. Fourteen team members represented six European professional societies, one European voluntary organisation, two international healthcare organisations and five professions, namely: Medical Physicists; Nuclear Medicine Physicians; Radiologists; Radiation Oncologists and Radiographers. Four subgroups analysed the "Strengths", "Weaknesses", "Opportunities" and "Threats" related to E&T in RP developed under previous European Union (EU) programmes and on the Guidelines on Radiation Protection Education and Training of Medical Professionals in the EU. RESULTS: Consensus agreement identified four themes for strengths and opportunities, namely: (1) existing structures and training recommendations; (2) RP training needs assessment and education & training (E&T) model(s) development; (3) E&T dissemination, harmonisation, and accreditation; (4) financial supports. Weaknesses and Threats analysis identified two themes: (1) awareness and prioritisation at a national/global level and (2) awareness and prioritisation by healthcare professional groups and researchers. CONCLUSIONS: A lack of effective implementation of RP principles in daily practice was identified. EuRnR strategic planning needs to consider processes at European, national and local levels. Success is dependent upon efficient governance structures and expert leadership. Financial support is required to allow the stakeholder professional agencies to have sufficient resources to achieve a pan European radiation protection training network which is sustainable and accredited across multiple national domains.

10.
Front Oncol ; 12: 883679, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35837099

RESUMO

Background: In the case of breast cancer (BC), radiotherapy (RT) helps reduce locoregional recurrence and BC-related deaths but can lead to cardiotoxicity, resulting in an increased risk of long-term major cardiovascular events. It is therefore of primary importance to early detect subclinical left ventricular (LV) dysfunction in BC patients after RT and to determine the dose-response relationships between cardiac doses and these events. Methods: Within the frame of the MEDIRAD European project (2017-2022), the prospective multicenter EARLY-HEART study (ClinicalTrials.gov Identifier: NCT03297346) included chemotherapy naïve BC women aged 40-75 years and treated with lumpectomy and adjuvant RT. Myocardial strain analysis was provided using speckle-tracking echocardiography performed at baseline and 6 months following RT. A global longitudinal strain (GLS) reduction >15% between baseline and follow-up was defined as a GLS-based subclinical LV dysfunction. Individual patient dose distributions were obtained using multi-atlas-based auto-segmentation of the heart. Dose-volume parameters were studied for the whole heart (WH) and left ventricle (LV). Results: The sample included 186 BC women (57.5 ± 7.9 years, 64% left-sided BC). GLS-based subclinical LV dysfunction was observed in 22 patients (14.4%). These patients had significantly higher cardiac exposure regarding WH and LV doses compared to patients without LV dysfunction (for mean WH dose: 2.66 ± 1.75 Gy versus 1.64 ± 0.96 Gy, p = 0.01). A significantly increased risk of subclinical LV dysfunction was observed with the increase in the dose received to the WH [ORs from 1.13 (V5) to 1.74 (Dmean); p <0.01] and to the LV [ORs from 1.10 (V5) to 1.46 (Dmean); p <0.01]. Based on ROC analysis, the LV-V5 parameter may be the best predictor of the short-term onset of subclinical LV dysfunction. Conclusion: These results highlighted that all cardiac doses were strongly associated with the occurrence of subclinical LV dysfunction arising 6 months after BC RT. Whether measurements of GLS at baseline and 6 months after RT combined with cardiac doses can early predict efficiently subclinical events occurring 24 months after RT remains to be investigated.

11.
Eur Radiol ; 32(8): 5525-5531, 2022 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-35294584

RESUMO

The terms "notifications" and "alerts" for medical exposures are used by several national and international organisations. Recommendations for CT scanners have been published by the American Association of Physicists in Medicine. Some interventional radiology societies as well as national authorities have also published dose notifications for fluoroscopy-guided interventional procedures. Notifications and alerts may also be useful for optimisation and to avoid unintended and accidental exposures. The main interest in using these values for high-dose procedures (CT and interventional) is to optimise imaging procedures, reducing the probability of stochastic effects and avoiding tissue reactions. Alerts in X-ray systems may be considered before procedures (as in CT), during procedures (in some interventional radiology systems), and after procedures, when the patient radiation dose results are known and processed. This review summarises the different uses of notifications and alerts to help in optimisation for CT and for fluoroscopy-guided interventional procedures as well as in the analysis of unintended and accidental medical exposures. The paper also includes cautions in setting the alert values and discusses the benefits of using patient dose management systems for the alerts, their registry and follow-up, and the differences between notifications, alerts, and trigger levels for individual procedures and the terms used for the collective approach, such as diagnostic reference levels. KEY POINTS: • Notifications and alerts on patient dose values for computed tomography (CT) and fluoroscopy-guided interventional procedures (FGIP) allow to improve radiation safety and contribute to the avoidance of radiation injuries and unintended and accidental exposures. • Alerts may be established before the imaging procedures (as in CT) or during and after the procedures as for FGIP. • Dose management systems should include notifications and alerts and their registry for the hospital quality programmes.


Assuntos
Proteção Radiológica , Fluoroscopia/métodos , Humanos , Doses de Radiação , Proteção Radiológica/métodos , Radiografia Intervencionista , Radiologia Intervencionista/métodos , Tomografia Computadorizada por Raios X/métodos
13.
Phys Med ; 96: 198-203, 2022 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-34955383

RESUMO

Patient contact shielding has been in use for many years in radiology departments in order to reduce the effects and risks of ionising radiation on certain organs. New technologies in projection imaging and CT scanning such as digital receptors and automatic exposure control (AEC) systems have reduced doses and improved image consistency. These changes and a greater understanding of both the benefits and the risks from the use of shielding have led to a review of shielding use in radiology. A number of professional bodies have already issued guidance in this regard. This paper represents the current consensus view of the main bodies involved in radiation safety and imaging in Europe: European Federation of Organisations for Medical Physics, European Federation of Radiographer Societies, European Society of Radiology, European Society of Paediatric Radiology, EuroSafe Imaging, European Radiation Dosimetry Group (EURADOS), and European Academy of DentoMaxilloFacial Radiology (EADMFR). It is based on the expert recommendations of the Gonad and Patient Shielding (GAPS) Group formed with the purpose of developing consensus in this area. The recommendations are intended to be clear and easy to use. They are intended as guidance, and they are developed using a multidisciplinary team approach. It is recognised that regulations, custom and practice vary widely on the use of patient shielding in Europe and it is hoped that these recommendations will inform a change management program that will benefit patients and staff.


Assuntos
Serviço Hospitalar de Radiologia , Radiologia , Criança , Consenso , Humanos , Doses de Radiação , Radiografia , Radiologia/métodos , Tomografia Computadorizada por Raios X/métodos
14.
Insights Imaging ; 12(1): 194, 2021 Dec 23.
Artigo em Inglês | MEDLINE | ID: mdl-34939154

RESUMO

Patient contact shielding has been in use for many years in radiology departments in order to reduce the effects and risks of ionising radiation on certain organs. New technologies in projection imaging and CT scanning such as digital receptors and automatic exposure control systems have reduced doses and improved image consistency. These changes and a greater understanding of both the benefits and the risks from the use of shielding have led to a review of shielding use in radiology. A number of professional bodies have already issued guidance in this regard. This paper represents the current consensus view of the main bodies involved in radiation safety and imaging in Europe: European Federation of Organisations for Medical Physics, European Federation of Radiographer Societies, European Society of Radiology, European Society of Paediatric Radiology, EuroSafe Imaging, European Radiation Dosimetry Group (EURADOS), and European Academy of DentoMaxilloFacial Radiology (EADMFR). It is based on the expert recommendations of the Gonad and Patient Shielding (GAPS) Group formed with the purpose of developing consensus in this area. The recommendations are intended to be clear and easy to use. They are intended as guidance, and they are developed using a multidisciplinary team approach. It is recognised that regulations, custom and practice vary widely on the use of patient shielding in Europe and it is hoped that these recommendations will inform a change management program that will benefit patients and staff.

15.
EClinicalMedicine ; 38: 101034, 2021 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-34337368

RESUMO

Imaging has become key in the care pathway of communicable and non-communicable diseases. Yet, there are major shortages of imaging equipment and workforce in low- and middle-income countries (LMICs). The International Society of Radiology outlines a plan to upscale the role of imaging in the global health agenda and proposes a holistic approach for LMICs. A generic model for organising imaging services in LMICs via regional Centres of Reference is presented. The need to better exploit IT and the potential of artificial intelligence for imaging, also in the LMIC setting, is highlighted. To implement the proposed plan, involvement of professional and international organisations is considered crucial. The establishment of an International Commission on Medical Imaging under the umbrella of international organisations is suggested and collaboration with other diagnostic disciplines is encouraged to raise awareness of the importance to upscale diagnostics at large and to foster its integration into the care pathway globally.

16.
Insights Imaging ; 12(1): 99, 2021 Jul 13.
Artigo em Inglês | MEDLINE | ID: mdl-34255191

RESUMO

This review presents basic information on the dosimetric quantities used in medical imaging for reporting patient doses and establishing diagnostic reference levels. The proper use of the radiation protection quantity "effective dose" to compare doses delivered by different radiological procedures and different imaging modalities with its uncertainties and limitations, is summarised. The estimates of population doses required by the European Directive on Basic Safety Standards is commented on. Referrers and radiologists should be familiar with the dose quantities to inform patients about radiation risks and benefits. The application of effective dose on the cumulative doses from recurrent imaging procedures is also discussed. Patient summary: Basic information on the measurement units (dosimetric quantities) used in medical imaging for reporting radiation doses should be understandable to patients. The Working Group on "Dosimetry for imaging in clinical practice" recommended that a brief explanation on the used dosimetric quantities and units included in the examination imaging report, should be available for patients. The use of the quantity "effective dose" to compare doses to which patients are exposed to from different radiological procedures and its uncertainties and limitations, should also be explained in plain language. This is also relevant for the dialog on to the cumulative doses from recurrent imaging procedures. The paper summarises these concepts, including the need to estimate the population doses required by the European Directive on Basic Safety Standards. Referrers and radiologists should be familiar with the dose quantities to inform patients about radiation risks and benefits.

17.
Eur Radiol ; 31(12): 9346-9360, 2021 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-33991223

RESUMO

OBJECTIVES: To assess information reflecting radiation dose and define diagnostic reference levels (DRL) on a European basis for four interventional radiology (IR) procedures considering clinical indication, anatomical region, and procedure. METHODS: A prospective European study was performed to provide data on the IR procedures percutaneous recanalization of iliac arteries, percutaneous recanalization of femoropopliteal arteries, transarterial chemoembolization of hepatocellular carcinoma, and percutaneous transhepatic biliary drainage. Hospitals were asked to complete a questionnaire giving information on procedure, equipment, and protocol. Patient size and weight, experience of the operator graded in number of procedures performed, and complexity level of each procedure were reported. Sixteen hospitals from 13 countries could be surveyed. The percentiles of the kerma-area product, fluoroscopy time, cumulative air kerma at the interventional reference point, and number of images were determined. The impact of equipment, year of installation, and complexity level of the procedure on dose were analyzed. RESULTS: DRLs based on clinical indication were defined. Dose values varied considerably within hospitals, between them, and within each subgroup of complexity level. The use of state-of-the-art equipment reduced dose significantly by 52%. Although dose also varied within each subgroup of complexity level, for transarterial chemoembolization of hepatocellular carcinoma and percutaneous transhepatic biliary drainage, dose significantly correlated with complexity. CONCLUSIONS: This was the first study reporting exposure practice and defining DRLs based on clinical indication for four IR procedures on a European basis. These DRLs can serve as a baseline for comparison with local practice, the study as a guideline for future surveys. KEY POINTS: • The use of state-of-the-art angiographic equipment reduces dose significantly. • A significant correlation between radiation dose and complexity level is found. • Dose values vary considerably, both within and between individual hospitals, and within each complexity level of interventional radiology procedure.


Assuntos
Carcinoma Hepatocelular , Quimioembolização Terapêutica , Neoplasias Hepáticas , Níveis de Referência de Diagnóstico , Humanos , Estudos Prospectivos , Doses de Radiação , Radiologia Intervencionista , Inquéritos e Questionários
18.
Eur Radiol ; 31(8): 5514-5523, 2021 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-33710370

RESUMO

In recent years, the issue of cumulative effective dose received from recurrent computed tomography examinations has become a subject of increasing concern internationally. Evidence, predominantly from the USA, has shown that a significant number of patients receive a cumulative effective dose of 100 mSv or greater. To obtain a European perspective, EuroSafe Imaging carried out a survey to collect European data on cumulative radiation exposure of patients from recurrent computed tomography examinations. The survey found that a relatively low percentage of patients (0.5%) received a cumulative effective dose equal to or higher than 100 mSv from computed tomography, most of them having an oncological disease. However, there is considerable variation between institutions as these values ranged from 0 to 2.72%, highlighting that local practice or, depending on the institution and its medical focus, local patient conditions are likely to be a significant factor in the levels of cumulative effective dose received, rather than this simply being a global phenomenon. This paper also provides some practical actions to support the management of cumulative effective dose and to refine or improve practice where recurrent examinations are required. These actions are focused around increasing awareness of referring physicians through encouraging local dialogue, actions focused on optimisation where a team approach is critical, better use of modern equipment and the use of Dose Management and Clinical Decision Support Systems together with focused clinical audits. The proper use of cumulative effective dose should be part of training programmes for referrers and practitioners, including what information to give to patients. Radiation is used to the benefit of patients in diagnostic procedures such as CT examinations, and in therapeutic procedures like the external radiation treatment for cancer. However, radiation is also known to increase the risk of cancer. To oversee this risk, the cumulative effective dose (CED) received by a patient from imaging procedures over his or her life is important. In this paper, the authors, on behalf of EuroSafe Imaging, report on a survey carried out in Europe that aims to estimate the proportion of patients that undergo CT examinations and are exposed to a CED of more than 100 mSv. At the same time, the survey enquires about and underlines radiologists' measures and radiology departments' strategies to limit such exposure. Over the period of 2015-2018, respondents reported that 0.5% (0-2.72%) of patients were exposed to a CED of ≥ 100 mSv from imaging procedures. The background radiation dose in Europe depends on the location, but it is around 2.5 mSv per year. It is obvious that patients with cancer, chronic diseases and trauma run the highest risk of having a high CED. However, even if the number of patients exposed to ≥ 100 mSv is relatively low, it is important to lower this number even further. Measures could consist in using procedures that do not necessitate radiation, using very low dose procedures, being very critical in requiring imaging procedures and increasing awareness about the issue. KEY POINTS: • A relatively low percentage of patients (0.5%) received a cumulative effective dose from CT computed tomography equal to or greater than 100 mSv, in Europe, most of them having an oncological disease. • There is a wide range in the number of patients who receive cumulative effective dose equal to or greater than 100 mSv (0-2.72%) and optimisation should be improved. • Increasing the awareness of referring physicians through encouraging local dialogue, concrete actions focused on optimisation and development of dose management systems is suggested.


Assuntos
Exposição à Radiação , Europa (Continente) , Feminino , Humanos , Masculino , Doses de Radiação , Inquéritos e Questionários , Tomografia Computadorizada por Raios X
19.
Lancet Oncol ; 22(4): e136-e172, 2021 04.
Artigo em Inglês | MEDLINE | ID: mdl-33676609

RESUMO

The diagnosis and treatment of patients with cancer requires access to imaging to ensure accurate management decisions and optimal outcomes. Our global assessment of imaging and nuclear medicine resources identified substantial shortages in equipment and workforce, particularly in low-income and middle-income countries (LMICs). A microsimulation model of 11 cancers showed that the scale-up of imaging would avert 3·2% (2·46 million) of all 76·0 million deaths caused by the modelled cancers worldwide between 2020 and 2030, saving 54·92 million life-years. A comprehensive scale-up of imaging, treatment, and care quality would avert 9·55 million (12·5%) of all cancer deaths caused by the modelled cancers worldwide, saving 232·30 million life-years. Scale-up of imaging would cost US$6·84 billion in 2020-30 but yield lifetime productivity gains of $1·23 trillion worldwide, a net return of $179·19 per $1 invested. Combining the scale-up of imaging, treatment, and quality of care would provide a net benefit of $2·66 trillion and a net return of $12·43 per $1 invested. With the use of a conservative approach regarding human capital, the scale-up of imaging alone would provide a net benefit of $209·46 billion and net return of $31·61 per $1 invested. With comprehensive scale-up, the worldwide net benefit using the human capital approach is $340·42 billion and the return per dollar invested is $2·46. These improved health and economic outcomes hold true across all geographical regions. We propose actions and investments that would enhance access to imaging equipment, workforce capacity, digital technology, radiopharmaceuticals, and research and training programmes in LMICs, to produce massive health and economic benefits and reduce the burden of cancer globally.


Assuntos
Países em Desenvolvimento/economia , Diagnóstico por Imagem/economia , Neoplasias/economia , Medicina Nuclear/economia , Efeitos Psicossociais da Doença , Custos de Cuidados de Saúde , Humanos , Neoplasias/diagnóstico , Pobreza , Radiografia/economia
20.
Eur Radiol ; 31(7): 4459-4469, 2021 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-33449177

RESUMO

OBJECTIVES: The objective of this study was to investigate the feasibility of defining diagnostic reference levels (DRLs) on a European basis for specific clinical indications (CIs), within the context of the European Clinical DRLs (EUCLID) European Commission project. METHODS: A prospective, multicenter, industry-independent European study was performed to provide data on 10 CIs (stroke, chronic sinusitis, cervical spine trauma, pulmonary embolism, coronary calcium scoring, coronary angiography, lung cancer, hepatocellular carcinoma, colic/abdominal pain, and appendicitis) via an online survey that included information on patient clinical, technical, and dosimetric parameters. Data from at least 20 patients per CI were requested from each hospital. To establish DRLs, a methodology in line with the International Commission on Radiological Protection (ICRP) Report 135 good practice recommendations was followed. RESULTS: Data were collected from 19 hospitals in 14 European countries on 4299 adult patients and 10 CIs to determine DRLs. DRLs differ considerably between sites for the same CI. Differences were attributed mainly to technical protocol and variable number of phases/scan lengths. Stroke and hepatocellular carcinoma were the CIs with the highest DRLs. Coronary calcium scoring had the lowest DRL value. Comparison with published literature was limited, as there was scarce information on DRLs based on CI. CONCLUSIONS: This is the first study reporting on feasibility of establishing CT DRLs based on CI using European data. Resulting values will serve as a baseline for comparison with local radiological practice, national authorities when DRLs are set/updated, or as a guideline for local DRL establishment. KEY POINTS: • First study reporting on the feasibility of establishing CT diagnostic reference levels based on clinical indication using data collected across Europe. • Only one-fourth of the hospitals had CT machines less than 5 years old. • Large dose variations were observed among hospitals and CT protocols were quite different between hospitals.


Assuntos
Níveis de Referência de Diagnóstico , Tomografia Computadorizada por Raios X , Adulto , Pré-Escolar , Europa (Continente) , Humanos , Estudos Prospectivos , Doses de Radiação , Valores de Referência
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA