Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 24
Filtrar
4.
Transfus Apher Sci ; 32(3): 287-97, 2005 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-15944115

RESUMO

Multicomponent apheresis (MCA) begun in Genoa in 1985 in autologous terms. Named "sequestration" it was the preoperative collection of autologous components (RBC-plasma-platelets) using the same apparatus and harness ready for intraoperative blood salvage. In 1986 the technique was applied to donor platelet apheresis with the goal of reducing the costs of platelet collection and concurrently reducing the risks of viral disease transmission to haematological patients who did receive, in the same transfusion event, the necessary blood components obtained from the same donor. The results of this application were maximized by the so called aggressive MCA by which in selected donors, it is possible to collect 2 units of platelets along with 1 or 2 units of PRBCs. These applications were made possible by the development of the concept of dry-platelet collection according to which platelets are collected in only 20-25 mL of plasma and subsequently resuspended in non-plasma solutions such as T-Sol. A last development of MCC is for RBC apheresis, with the collection of 1-2 units of RBC independently of platelet collection. This is going to be the first step of apheresis as the unique modality of collecting blood leaving the bags to history of blood transfusion. Interestingly it took 15 years to MCC to be rediscovered and appreciated worldwide both for its intrinsic cost saving capabilities offered along with an increasing safety for patients. In terms of donor acceptance it is our experience that, since 1989 no donor has refused MCC, consisting at least in the concurrent collection of plasma along with platelets, but also RBC and or a second unit of platelets.


Assuntos
Doadores de Sangue , Citaferese , Doadores de Sangue/estatística & dados numéricos , Transfusão de Sangue Autóloga/estatística & dados numéricos , Citaferese/economia , Citaferese/estatística & dados numéricos , Humanos , Itália
6.
Int J Artif Organs ; 19(7): 431-4, 1996 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-8841858

RESUMO

A new CFC apparatus for intraoperative blood salvage (CATS) has been introduced by Fresenius and submitted to preliminary evaluation at our hemapheresis unit. The volume of shed blood submitted to washing was 1714 +/- 496 with a hematocrit of 19% and the volume of PRBC ready for transfusion 297.9 ml with hematocrit of 64.3%. Elimination of contaminant activated platelets and WBC was 92% and 74% respectively. Elimination of contaminants such as protein, free hemoglobin, LDH and K ions was always over 95%. Regular application of CATS is warrented after our study.


Assuntos
Transfusão de Sangue Autóloga , Eritrócitos/citologia , Leucócitos/citologia , Tamanho Celular/fisiologia , Hematócrito , Humanos , Complicações Intraoperatórias , Ativação Plaquetária , Estudos Retrospectivos
7.
Int J Artif Organs ; 18(3): 136-42, 1995 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-7499016

RESUMO

Optimal blood supply is critical to modern medical practice. Among the different possibilities of improving the quality and safety of blood, it is generally felt that autologous donation has played an important role and has contributed to changing transfusional practices, mainly since the appearance of HIV and HCV on the blood transfusion scene. At the San Martino Hospital Immunohematology Service, the autotransfusion era began in 1985. Autologous predeposit donation was the first to be introduced, followed by intentional perioperative hemodilution, intraoperative blood salvage with DFC apparatuses and lastly post-operative blood salvage. From about 200 autologous donations in 1985 we reached 5,372 in 1993 and more than 6,000 autologous donations are expected for 1994. Only 189 intraoperative blood salvages, were carried out in 1986, 593 in 1989, 1,207 in 1993 and more than 1,500 blood salvage sessions are anticipated for 1994. In the meantime, the total number of homologous RBC units employed in the Hospital dropped from 45,000 in 1985 to 18,000 in 1994, with the Onco-hematological Divisions using approximately 10,000 units of packed RBC.


Assuntos
Transfusão de Sangue Autóloga/normas , Controle de Infecções , Plaquetas/citologia , Plaquetas/fisiologia , Transfusão de Sangue Autóloga/efeitos adversos , Transfusão de Sangue Autóloga/métodos , Eritrócitos/citologia , Eritrócitos/fisiologia , Hemodiluição , Hemofiltração , Humanos , Complicações Intraoperatórias/etiologia , Fatores de Risco , Transplante Homólogo/normas
8.
Int J Artif Organs ; 18(1): 39-44, 1995 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-7607757

RESUMO

The last five years have been characterized by the presentation of new cell separators the main task of which is the collection of high yield-high quality platelets. The CS3000 is an old apparatus which has undergone rejuvenation to sustain the assault of its new competitors. The CS3000 Plus Omnix system is the latest version to be offered along with a combination of TNX-6 separation/PLT30 collection chambers for optimal platelet collection. In this paper we present our results with this apparatus and configuration after its adaptation to the collection and storage of platelets in a non-plasma medium, the Baxter Plasma-Lyte A. After separation the platelet product (PC) was left in the collection chamber and resuspended with 200 ml of Plasma-Lyte A instead of being resuspended in autologous plasma as usual. Plasma was collected in a separate bag (400-450 ml) for transfusion or fractionation purposes. PC quality was assessed by evaluating the platelet yield (4.17 +/- 1.8 x 10(11), and the WBC contamination (4.8 +/- 2.6 x 10(5)). The presence of platelet aggregates (platelet count after aggregate fixation with formalin/platelet count after disaggregation in EDTA), the aggregation induced by ADP, collagen and ristocetin, the hypotonic shock response and the stability of membrane glycoproteins (CD 62 - 62 - 63 - 36- 42b - 51) were measured in the preapheresis samples and in the PC immediately after, 24 and 72 hours after collection. These results were totally satisfactory as was the post-transfusion survival measured as corrected count increment in 10 transfusions to non refractory patients.(ABSTRACT TRUNCATED AT 250 WORDS)


Assuntos
Plaquetas/citologia , Separação Celular/normas , Plaquetoferese , Difosfato de Adenosina/farmacologia , Adulto , Contagem de Células , Membrana Celular/metabolismo , Fracionamento Químico , Colágeno/farmacologia , Feminino , Humanos , Leucócitos/citologia , Masculino , Glicoproteínas de Membrana/metabolismo , Glicoproteínas de Membrana/fisiologia , Pessoa de Meia-Idade , Agregação Plaquetária/efeitos dos fármacos , Controle de Qualidade , Ristocetina/farmacologia
10.
J Clin Apher ; 9(3): 195-9, 1994.
Artigo em Inglês | MEDLINE | ID: mdl-7706202

RESUMO

There has been an increasing interest in recent years over the qualitative superiority of single-donor platelets in the management of hemato-oncologic patients. The reasonable desire of both patients and physicians to limit the risks of transfusion along with the need for limiting the costs involved in this kind of therapy have led to application of multicomponent donations both in terms of double platelet concentrates and double products such as red blood cells (RBC) and platelets from the same donor. Single donor platelets and RBC have been collected in a semi-automated mode and only the very recent introduction of the Haemonetics MCS 3p with its SDP/RBC protocol provides a totally closed-system automated protocol for this combined collection. Twenty procedures have been carried out so far at our unit. In a mean of 87 minutes (6-7 passes), a mean of 3.1 x 10(11) platelets were collected along with approximately 220 mL of packed RBC. The leukocyte contamination of the platelet product was in the range of 0.4-1.1 x 10(7) (99% lymphocytes), and the quality of platelets was very satisfactory as measured by the hypotonic shock response, aggregation induced by ADP, collagen and ristocetin, morphology score, and membrane glycoproteins modifications. Equally satisfactory was the quality of the RBC concentrate, suspended in 80 mL of SAG-M, with a total hemoglobin (Hb) content approaching 55 g as compared to the normal Hb content of a standard RBC concentrate that is approximately 62 g.(ABSTRACT TRUNCATED AT 250 WORDS)


Assuntos
Remoção de Componentes Sanguíneos/instrumentação , Eritrócitos , Plaquetoferese , Adulto , Doadores de Sangue , Feminino , Humanos , Masculino
11.
Int J Artif Organs ; 16 Suppl 5: 119-24, 1993 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-8013968

RESUMO

An exciting, fast moving and promising field remains the use of plasma-free synthetic medium for platelet storage (10, 11), that along with the potential for getting more plasma for therapeutic needs, might also improve the quality of stored platelets. Addition of acetate to solution, may be the way to obtain these results. An astonishing fact is that citrate remains the only anticoagulant for platelet collection, and remains as well the only real cause of donor discomfort during thrombocytapheresis.


Assuntos
Plaquetoferese/instrumentação , Doadores de Sangue , Humanos , Plaquetoferese/métodos , Controle de Qualidade
12.
Int J Artif Organs ; 16 Suppl 5: 173-6, 1993 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-8013981

RESUMO

The number of conditions that can benefit from Plasma-Exchange (PE) continues to grow. We have recently added to the list the Cyclosporin-A induced hypertrygliceridemia and myoglobinuric acute renal insufficiency. Such as any therapeutic measure for PE, four evolutive phases can be recognized: the discovery and research, the confirmation of indications, the routine applications and the decline, when new more powerful tools are offered by culture or technology. We have participated in the first three phases during the last 20 years. Not necessarily all experiences were favourable. Nonetheless, we feel that, for the time being, a hemapheresis unit is an absolute necessity for a medium - sized hospital even if only therapeutic procedures are carried out. The phase four, decline of interest and applications, cannot be foreseen. Finally the ability of PE to shorten substantially the length of hospital stays along with the ease with which procedure can be performed on ambulatory patients, substantiate a favourable cost/benefit ratio for this therapeutic modality.


Assuntos
Troca Plasmática , Plasmaferese , Humanos , Troca Plasmática/efeitos adversos , Plasmaferese/efeitos adversos
13.
Int J Artif Organs ; 16 Suppl 5: 257-9, 1993 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-8014001

RESUMO

Autologous transfusion is playing an important role in modern transfusion medicine. At San Martino hospital we use a combination of manual and mechanical techniques in order to improve autotransfusion procedures, control the hypertransfusion and avoid waste. Our autotransfusion program has determined a 55% reduction in the red cell concentrates used (from 42,000 in 1985 down to 19,400 in 1992). Proper training, cultural improvements and new applications on autotransfusion procedures will permit a better use of blood with less transfusion related complications, until a suitable substitute for blood will be available.


Assuntos
Transfusão de Sangue Autóloga/métodos , Perda Sanguínea Cirúrgica , Hemodiluição , Humanos
14.
Infusionsther Transfusionsmed ; 20(1-2): 11-3, 1993 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-8504235

RESUMO

BACKGROUND: The evolution of technology has been one of the most interesting features that has accompanied thrombocytapheresis throughout the years. In this presentation we report on the preliminary results obtained with Excel, a third-generation cell separator that is presently in its early experimental phase. MATERIAL AND METHODS: So far only 15 thrombocytapheresis procedures, 2 of which of the single-needle type, were carried out on 15 healthy donors processing 4 liters of blood (2.8 liters in single needle). RESULTS AND CONCLUSIONS: The results were satisfactory since the average platelet yield was 4.7 x 10(11). The leukocyte contamination was 0.8 x 10(6) and the RBC contamination 0.4 x 10(7). The platelet efficiency per minute was 6.5 x 10(9), and the run time average 72 min. As to the quality of the product the very first results of platelet aggregation, relative to pre-apheresis, were 78% in response to ADP 6 microM; 106 and 102% in response to collagen 4.5 micrograms/ml and ristocetin 1.5 mg/ml, respectively. Essentially no platelet aggregates were found in the platelet products (Wu-Hoak ratio: 0.91).


Assuntos
Computadores , Plaquetoferese/instrumentação , Adulto , Animais , Velocidade do Fluxo Sanguíneo/fisiologia , Volume Sanguíneo/fisiologia , Bovinos , Contagem de Eritrócitos , Feminino , Humanos , Contagem de Leucócitos , Masculino , Agulhas , Contagem de Plaquetas
15.
Infusionsther Transfusionsmed ; 20(1-2): 8-10, 1993 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-8504244

RESUMO

BACKGROUND: The Fresenius AS 104 cell separator has recently met some popularity in European apheresis units for the quality of the platelets obtained with the totally automated double-needle procedure. MATERIALS AND METHODS: Taking advantage of the machine's flexibility we have developed a new automated procedure for single-needle thrombocytapheresis (SNP). So far 61 SNP were carried out. From donors having a platelet precount of 2.74 x 10(5) an average of 3.8 x 10(11) cells were collected by processing 2.5 liters of blood in a run time of 83 min. RESULTS AND CONCLUSIONS: The leukocyte and erythrocyte contaminations were 2.7 x 10(7) and 3.5 x 10(7), respectively. Only 2 products did contain less than 3.5 x 10(11) platelets, and 7 procedures were complicated by minor signs of hypocalcemia. With minor modifications this SNP is presently offered on a routine basis to our platelet donors.


Assuntos
Computadores , Agulhas , Plaquetoferese/instrumentação , Adulto , Volume Sanguíneo/fisiologia , Desenho de Equipamento , Contagem de Eritrócitos , Feminino , Humanos , Contagem de Leucócitos , Masculino , Contagem de Plaquetas
17.
J Clin Apher ; 6(3): 158-60, 1991.
Artigo em Inglês | MEDLINE | ID: mdl-1787133

RESUMO

A case of severe cyclosporin-induced hypertriglyceridemia that prompted plasma exchange therapy is reported. Hyperlipemic retinitis, headache, stupor, and peripheral paresthesias became apparent when the level of triglycerides exceeded the 1,500 mg/dL level. Two plasma exchanges were required to halt disease progression. This is the second time that plasma exchange was used in a bone marrow transplanted patient on cyclosporin-A therapy. In both cases hypertriglyceridemia became apparent and symptomatic after approximately 7 months of therapy with cyclosporin.


Assuntos
Transplante de Medula Óssea , Ciclosporina/efeitos adversos , Hipertrigliceridemia/terapia , Troca Plasmática , Complicações Pós-Operatórias/terapia , Adolescente , Bezafibrato/uso terapêutico , Terapia Combinada , Feminino , Doença Enxerto-Hospedeiro/tratamento farmacológico , Humanos , Hipertrigliceridemia/induzido quimicamente , Hipertrigliceridemia/tratamento farmacológico , Imunoglobulinas Intravenosas/administração & dosagem , Complicações Pós-Operatórias/induzido quimicamente , Complicações Pós-Operatórias/tratamento farmacológico , Prednisona/uso terapêutico
18.
J Clin Apher ; 6(2): 84-7, 1991.
Artigo em Inglês | MEDLINE | ID: mdl-1938995

RESUMO

Among the many blood cell separators introduced into the international market in these last few years, the Fresenius AS 104 represents an advanced and safe thrombocytapheresis machine whose development took advantage of extensive worldwide experience with blood cell separation. Nonetheless the AS 104 has generated most interest in West Germany and most, if not all, the studies published on its platelet collection efficiency have been carried out in that country. It is normally reported that from 2.7 to 3.5 x 10(11) platelets can be collected in approximately 80 minutes. Since these results could not be duplicated routinely in our hemapheresis unit, we set up a study by modifying the standard procedure. It was possible to reduce the procedure time and to collect platelet concentrates containing more than 4 x 10(11) cells on a routine basis by using the following procedure: ACD-A/blood ratio 1:10; Interface position 6:2; blood flow rate always exceeding 65 mL/min; rpm 1750; cell collection from 4 to 7 mL/min; volume of blood processed 3.6 L followed by the rinsing of the system with 200 ml of saline; extraction of the content of the secondary separation chamber by the action of the plasma pump working at 20 mL/min for 2 min. With this procedure the platelet yield in 34 collections exceeded 3.1 x 10(11) and averaged 4.06 x 10(11). The procedure time was reduced to 56.5 minutes with a mean blood flow rate of 62.3 mL/min. The leukocyte and erythrocyte contamination of the products were in the range of 1 x 10(7) and 1 x 10(8) respectively.(ABSTRACT TRUNCATED AT 250 WORDS)


Assuntos
Plaquetoferese/instrumentação , Estudos de Avaliação como Assunto , Humanos , Agregação Plaquetária , Contagem de Plaquetas , Fatores de Tempo
20.
Int J Artif Organs ; 11(3): 209-11, 1988 May.
Artigo em Inglês | MEDLINE | ID: mdl-3042634

RESUMO

The authors report a case of hypertriglyceridemia complicating the course of a patient receiving cyclosporin A after bone marrow transplantation. When the patient was seen at the hemapheresis unit the clinical picture was characterized by headache, increasing visual and neurological disturbances. Plasma triglyceride level was 3215 mg/dl. Two plasma exchange sessions reduced triglycerides to 486 mg/dl and halted the disease progression. This may represent the first plasma exchange treatment of cyclosporin A-induced hypertriglyceridemia.


Assuntos
Ciclosporinas/efeitos adversos , Hiperlipidemias/terapia , Troca Plasmática , Plasmaferese , Triglicerídeos/sangue , Adulto , Transplante de Medula Óssea , Humanos , Leucemia Mieloide/terapia , Masculino
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA