Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
1.
Heliyon ; 10(2): e24482, 2024 Jan 30.
Artigo em Inglês | MEDLINE | ID: mdl-38293484

RESUMO

The research object is diorite in the Lingbei TBM section of the Hanjiang-To-Weihe River Qinling tunnel, with a buried depth of over 1 km. Using MTS-2000 microcomputer-controlled electro-hydraulic servo universal testing machine and DS5-16b acoustic emission (AE) monitoring system, uniaxial compression and acoustic emission monitoring tests were carried out on rock samples, to study the uniaxial compression mechanical properties and acoustic emission characteristics of the deep diorite. The results of the study indicate that: (1) During uniaxial compression, diorite undergoes four stages: initial compaction, elasticity, yield and failure, in which the curve of the initial compaction stage is significantly smoother. The uniaxial compressive strength is 41.95 MPã102.42 MPa, with an average of 74.07 Mpa; The axial peak strain ranges from 1 % to 1.4 %, and the failure mode belongs to brittle ductile splitting failure. (2) The cumulative ringing count and energy showed a very slow increase trend during the calm period; After entering a surge period (with the appearance of Kaiser points), both show a significant transition state; During the slow increase period, the overall growth rate of the two slowed down and remained almost silent. (3) On the basis of the analysis of RA-AF values during the deformation and rupture process of diorite, it can be seen that the damage type of diorite is tensile damage by the significant low RA value and high AF value characteristics, which coincides with the actual damage fracture characteristics of the rocks in the sample. (4) During the compaction stage, there are few acoustic emission location points, which correspond to low energy and are mainly distributed at the higher and lower ends of the sample; After entering the elasticity stage, the number of positioning points significantly increases and gradually expands towards the middle; Near Kaiser point, the number of location points and corresponding energy are both in a sharp increase state, and this trend is in good agreement with the changes in the ringing count-time and energy-time curves. (5) The damage time mainly starts at the end of the calm period, and the pattern of change in the damage curve coincides with the localization point and energy evolution. The results of the research can be used as a referential basis for the development of the excavation, protection and other construction plans for the Lingbei TBM section of the Hanjiang-To-Weihe River Qinling tunnel or similar surrounding rock tunnels, as well as for further conducting triaxial unloading tests on diorite.

2.
Guang Pu Xue Yu Guang Pu Fen Xi ; 35(5): 1409-13, 2015 May.
Artigo em Chinês | MEDLINE | ID: mdl-26415469

RESUMO

Temperature drift will be brought to Micro-Spectrometer used for demodulating the Varied Line-Space(VLS) grating position sensor on aircraft due to high-low temperature shock. We successfully made a Micro-Spectrometer, for the VLS grating position sensor on aircraft, which still have stable output under temperature shock enviro nment. In order to present a real time temperature compensation scheme, the effects temperature change has on Micro-Spectrometer are analyzed and the traditional cross Czerny-Turner (C-T)optical structure is optimized. Both optical structures are analyzed by optics design software ZEMAX and proved that comparedwithtraditional cross C-T optical structure, the newone can accomplish not only smaller spectrum drift but also spectrum drift with better linearity. Based on the new optical structure. The scheme of using reference wavelength to accomplish real time temperature compensation was proposed and a Micro-fiber Spectrometer was successfully manufactured, whith is with Volume of 80 mm X 70 mmX 70 mm, integration time of 8 ~1 000 ms and FullWidthHalfMaximum(FWHM) of 2 nm. Experiments show that the new spectrometer meets the design requirement. Under high temperature in the range of nearly 60 °C, the standard error of wavelength of this new spectrometer is smaller than 0. 1 nm, and the maximum error of wavelength is 0. 14 nm, which is much smaller than required 0. 3 nm. Innovations of this paper are the schemeof real time temperature compensation, the new cross C-T optical structure and a Micro-fiber Spectrometer based on it.

3.
Guang Pu Xue Yu Guang Pu Fen Xi ; 24(3): 372-5, 2004 Mar.
Artigo em Chinês | MEDLINE | ID: mdl-15760004

RESUMO

The quartz depolarizer consisting of two wedge-shaped quartz crystals was designed based on the Lyot depolarizer. The quartz depolarizer is used to reduce the polarization response of spectral instruments. The residual degree of polarization of the quartz depolarizer was derived by the method of matrix optics, so the variation regularity of its depolarization characteristic was analysed concerning its center thickness and the status of the incident radiation in the UV-VUV spectral range. Its depolarization effect was obvious for the radiation with some spectral bandwidth. Also, the depolarization characteristic of the quartz depolarizer was studied experimentally with 1-meter Seya-Namioka UV-VUV spectrometer, using LiF crystals as the polarizer and analyzer. The residual degree of polarization of the quartz depolarizer was less than 1%. Both the theoretical analysis and experimental results show that the quartz depolarizer we designed is appropriate to the spectral measurement with high accuracy.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA