RESUMO
Matrix-assisted laser desorption/ionization time-of-flight mass spectrometryï¼ MALDI-TOF MSï¼ is a bacterial typing tool that was approved as a medical device in 2011. However, external accuracy control examination of bacterial typing using mass spectrometry is still only performed on a small scale. In this study, E. faecium and S. maltophilia were selected and tested according to established procedures using Score Values at 228 institutions. The Score Values for MALDI Biotyper were 2.43±0.08 for E. faecium and 2.38±0.08 for S. maltophilia; and those for VITEK MS/PRIME were 99.9±0.0 for E. faecium and S. maltophilia. These results suggest that it is useful to evaluate external accuracy control with Score Values using the procedures we have developed.
Assuntos
Lasers , Espectrometria de Massas por Ionização e Dessorção a Laser Assistida por Matriz/métodos , Técnicas de Tipagem Bacteriana/métodosRESUMO
Matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF MS) was approved for medical use in 2011 and is currently used as a rapid, accurate and lowcost technique for bacterial identification. External quality control for medical analysis is monitored using tests of the Japanese Association of Medical Technologists and Prefectural Association of Clinical Laboratory Technologists and through user surveys of reagent and equipment manufacturers. However, external quality control of bacterial typing using MS is not performed. Therefore, we examined procedures for evaluating quality control of bacterial typing using an identification reliability index at 38 facilities.
Assuntos
Lasers , Técnicas de Tipagem Bacteriana/métodos , Controle de Qualidade , Reprodutibilidade dos Testes , Espectrometria de Massas por Ionização e Dessorção a Laser Assistida por Matriz/métodosRESUMO
Matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF MS) was approved for medical use in 2011, and is currently used as a rapid, accurate and low-cost technique for bacterial identification. Microbiological testing and internal accuracy control in Japan are mainly implemented in accordance with the standards of the Clinical and Laboratory Standards Institute (CLSI). However, few facilities perform internal accuracy control of bacterial identification by MALDI-TOF MS. Therefore, we examined the procedures for internal accuracy control of bacterial identification using MALDI-TOF MS in daily work at clinical laboratories in the seven hospitals.