Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
1.
Shokuhin Eiseigaku Zasshi ; 64(4): 154-160, 2023.
Artigo em Japonês | MEDLINE | ID: mdl-37673605

RESUMO

An inter-laboratory study involving 24 laboratories was conducted to validate the modified analytical method for the migration solution of heptane for the determination of bisphenol A migrating from polycarbonate food processing materials. In this study, two concentrations of samples were blindly coded. Each laboratory determined the analyte (bisphenol A, phenol and p-tert-butylphenol) concentration in each sample according to the established protocol. The obtained values were analyzed statistically using internationally accepted guidelines. Horwitz ratios were calculated based on the reproducibility relative standard deviation (RSDR), which was estimated from the inter-laboratory study, and predicted RSDR, which was calculated using the Horwitz/Thompson equation. Horwitz ratios of the two samples ranged from 0.15 to 0.37 for the three compounds, meeting the performance criteria of less than 2 set by the Codex Alimentarius for analytical method approval. These results showed that this modified analytical method shows good performance as an analytical method for the migration solution of heptane.


Assuntos
Heptanos , Fenóis , Reprodutibilidade dos Testes
2.
Artigo em Inglês | MEDLINE | ID: mdl-31242064

RESUMO

A survey of the contamination of foods by sterigmatocystin (STC) was performed by an analytical method based on LC-MS/MS. STC was extracted from samples with acetonitrile/water (85/15, v/v) and then purified with immunoaffinity columns. The method was validated by a small-scale inter-laboratory study using spiked wheat samples. Mean recoveries of STC were 100.3% and 92.5% from two samples spiked at 0.5 and 5.0 µg/kg, respectively. A total of 583 samples were analysed between 2016 and 2018, and STC was detected in 19.9% of all samples at >0.05 µg/kg (limit of quantification). The foods that were contaminated by STC were wheat flour, Job's tears products, rye flour, rice, buckwheat flour, white sorghum, barley products, azuki bean and corn flour. STC was not found in beer or wine. The occurrence of STC in domestic wheat flour (44.4%), Job's tears products (41.7%) and rye flour (29.9%) accounted for the three highest values. The highest mean concentrations were obtained for Job's tears products (0.3 µg/kg) and rye flour (0.3 µg/kg). The maximum contamination level was present in a sample of rye flour (7.1 µg/kg). Although the contamination levels were low, these results indicate that STC frequently contaminates Japanese retail foods. A continuous survey is required to assess exposure to STC in Japan.


Assuntos
Análise de Alimentos , Contaminação de Alimentos/análise , Esterigmatocistina/análise , Cromatografia Líquida , Japão , Reprodutibilidade dos Testes , Espectrometria de Massas em Tandem
3.
Food Chem ; 240: 386-390, 2018 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-28946287

RESUMO

The preservatives benzoic acid and sorbic acid are generally quantified with separation techniques, such as HPLC or GC. Here we describe a new method for determining these compounds in processed food samples based on a narrowness of the UV-visible spectral band width with derivative processing. It permits more selective identification and determination of target analytes in matrices. After a sample is purified by micro dialysis, UV spectra of sample solutions were measured and fourth order derivatives of the spectrum were calculated. The amplitude between the maximum and minimum values in a high-order derivative spectrum was used for the determination of benzoic acid and sorbic acid. Benzoic acid and sorbic acid levels in several commercially available processed foods were measured by HPLC and the proposed spectrometry method. The levels obtained by the two methods were highly correlated (r2>0.97) for both preservatives.


Assuntos
Ácido Benzoico/análise , Ácido Sórbico/análise , Conservantes de Alimentos , Conservantes Farmacêuticos , Diálise Renal , Espectrofotometria
4.
J Chromatogr A ; 1434: 136-41, 2016 Feb 19.
Artigo em Inglês | MEDLINE | ID: mdl-26810804

RESUMO

The consequences of matrix effects in GC are a major issue of concern in pesticide residue analysis. The aim of this study was to evaluate the applicability of an analyte protectant generator in pesticide residue analysis using a GC-MS system. The technique is based on continuous introduction of ethylene glycol into the carrier gas. Ethylene glycol as an analyte protectant effectively compensated the matrix effects in agricultural product extracts. All peak intensities were increased by this technique without affecting the GC-MS performance. Calibration curves for ethylene glycol in the GC-MS system with various degrees of pollution were compared and similar response enhancements were observed. This result suggests a convenient multi-residue GC-MS method using an analyte protectant generator instead of the conventional compensation method for matrix-induced response enhancement adding the mixture of analyte protectants into both neat and sample solutions.


Assuntos
Etilenoglicol/química , Análise de Alimentos/métodos , Contaminação de Alimentos/análise , Cromatografia Gasosa-Espectrometria de Massas/métodos , Resíduos de Praguicidas/análise , Calibragem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA