Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
1.
Radiol Case Rep ; 19(10): 4260-4265, 2024 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-39135676

RESUMO

Primary racemose hemangioma of the bronchial artery (RHBA) is a rare congenital condition characterized by enlarged and convoluted bronchial arteries, often forming fistulas between the pulmonary artery or vein. Herein, we report a case of balloon-assisted embolization using N-butyl-2-cyanoacrylate (NBCA) performed for a primary RHBA in an asymptomatic 57-year-old woman. There were 2 tortuous and dilated branches of the right bronchial artery (RBA) (arising from the left subclavian artery and the descending thoracic aorta) which merged in the right pulmonary hilar region, forming multiple aneurysms that short-circuited the right pulmonary artery. Embolization was performed via the RBA arising from the subclavian artery using a triaxial system (a 5-Fr guiding catheter, a 2.7-Fr microballoon catheter, and a 1.9-Fr microcatheter). The guiding catheter was inserted into the peripheral side of the RBA using the microballoon catheter as an anchor; the balloon was slightly inflated and advanced further into the peripheral side using blood flow. The microcatheter was inserted as close to the aneurysms as possible and embolization was done using an NBCA-iodized oil mixture under blood flow control by the microballoon catheter. Bronchial artery embolization is the treatment of choice for primary RHBA because of the risk of rupture, and balloon-assisted techniques can help guide the catheter distally while also controlling blood flow.

2.
Radiol Case Rep ; 19(8): 2984-2987, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-38737185

RESUMO

Epipericardial fat necrosis is a rare cause of acute pleuritic chest pain and is a benign and self-limiting condition. It is important to distinguish epipericardial fat necrosis from other diseases that cause acute chest pain, such as acute myocardial infarction, pulmonary embolism, and acute pericarditis, because conservative treatment is recommended for epipericardial fat necrosis. This report presents the case of a 25-year-old man with severe pleuritic chest pain located on the left anterior side that was associated with dyspnea. Electrocardiogram and laboratory data were normal, except for a slight elevation of C-reactive protein level. Contrast-enhanced chest computed tomography revealed a fatty ovoid lesion surrounded by a thick rim on the left side of the pericardial fat. Fat stranding was observed both inside and adjacent to the fatty ovoid lesion. A slight contrast enhancement of the thick rim and a slight linear enhancement inside the lesion were observed. Furthermore, a small amount of left pleural effusion was observed. The patient was diagnosed with epipericardial fat necrosis and treated with analgesics, and the symptoms improved 1 week after the emergency department visit. Radiologists should be familiar with epipericardial fat necrosis to prevent overlooking and misdiagnosing the condition.

3.
Radiol Case Rep ; 19(3): 876-880, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38188963

RESUMO

Transcatheter arterial embolization is a useful treatment for postpancreatectomy hemorrhage, a severe complication of pancreatic surgery. N-butyl cyanoacrylate is a liquid and permanent embolic material that is widely used in transcatheter arterial embolization. However, its use can lead to the adherence of the catheter to the vessel wall and occlusion of the catheter lumen. This case report presents the case of a 63-year-old man with a postpancreatectomy posterior superior pancreaticoduodenal artery pseudoaneurysm, which ruptured and bled into a drain tube. The patient underwent transcatheter arterial embolization using N-butyl cyanoacrylate and a gelatin sponge without the incidence of adherence or occlusion of the drain tube. Gelatin sponge, which was used as a temporary embolic material, was effective in preventing the drain tube from adhering and occluding.

4.
Jpn J Radiol ; 42(5): 460-467, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38148339

RESUMO

PURPOSE: To evaluate the diagnostic performance and feasibility of a modified computed tomography (CT) scan protocol, we performed a serial assessment of the computed tomography angiography for pulmonary artery (CTA-P) and systemic artery (CTA-S) (CTA-PS) using a reduced contrast agent dose to diagnose systemic artery-to-pulmonary artery shunts (SPSs). MATERIALS AND METHODS: Twenty-five patients who underwent multiphase contrast-enhanced chest CT and conventional chest angiography were included. Three image sets (CTA-P, CTA-S, and CTA-PS) were evaluated by two board-certified radiologists. The visualization of the CT image findings associated with SPSs, such as filling defects and enhancement in the pulmonary arteries, was evaluated using a 5-point scale. RESULTS: The diagnostic performance (sensitivity, specificity, and accuracy) of CT imaging findings associated with SPSs in CTA-P and CTA-PS were as follows: CTA-P, 57.1%, 87.5%, and 62.0%; CTA-PS, 81.0%, 100.0%, and 84.0%. CT findings associated with SPSs in CTA-P were significantly sensitive to the CTA-PS protocol. There were no significant differences between the CTA-S and CTA-PS protocols. The area under the curve (AUC) of the CT imaging findings associated with SPSs in the CTA-P and CTA-PS groups was 0.835 and 0.911, respectively (P = 0.191). The AUC of the CT imaging findings associated with SPSs in CTA-S and CTA-PS were 0.891 and 0.926, respectively (P = 0.373). CONCLUSION: CTA-PS using a reduced contrast agent dose protocol could improve the overall diagnostic confidence of SPSs, owing to better visualization of CT imaging findings associated with SPSs compared to individual assessments of CTA-P or CTA-S. Therefore, CTA-PS can be used as an alternative preembolization evaluation modality to conventional angiography in patients with hemoptysis suspected of having SPSs.


Assuntos
Angiografia por Tomografia Computadorizada , Meios de Contraste , Estudos de Viabilidade , Artéria Pulmonar , Sensibilidade e Especificidade , Humanos , Meios de Contraste/administração & dosagem , Masculino , Feminino , Artéria Pulmonar/diagnóstico por imagem , Angiografia por Tomografia Computadorizada/métodos , Pessoa de Meia-Idade , Idoso , Adulto , Estudos Retrospectivos , Idoso de 80 Anos ou mais , Reprodutibilidade dos Testes
5.
Radiol Case Rep ; 18(7): 2385-2390, 2023 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-37179814

RESUMO

N-butyl cyanoacrylate, one of embolic materials, is usually used as a mixture with Lipiodol (N-butyl cyanoacrylate-Lipiodol mixture). N-butyl cyanoacrylate-Lipiodol-Iopamidol was developed by adding a nonionic iodine contrast agent (Iopamiron) to N-butyl cyanoacrylate-Lipiodol mixture. N-butyl cyanoacrylate-Lipiodol-Iopamidol has lower adhesiveness than N-butyl cyanoacrylate-Lipiodol mixture and the ability to form a single large droplet. We report the case of a 63-year-old man with a ruptured splenic artery aneurysm treated by transcatheter arterial embolization using N-butyl cyanoacrylate-Lipiodol-Iopamidol. He was referred to the emergency room because of sudden onset of upper abdominal pain. A diagnosis was established using contrast-enhanced computed tomography and angiography. Emergency transcatheter arterial embolization was performed, and the ruptured splenic artery aneurysm was successfully embolized using a combination of coil framing and N-butyl cyanoacrylate-Lipiodol-Iopamidol packing. This case demonstrates the usefulness of a combination of coil framing and N-butyl cyanoacrylate-Lipiodol-Iopamdol packing for the embolization of aneurysms.

6.
BJR Open ; 3(1): 20210018, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34877452

RESUMO

OBJECTIVE: To optimize the scan protocol for high temporal resolution magnetic resonance (MR) imaging of the liver under single breath-holding, using compressed sensing (CS) and parallel imaging (PI) techniques in a 1.5 T MR system. METHODS: 31 healthy volunteers who underwent fat-suppressed gradient-echo T 1 weighted imaging using a 1.5 T MR system were included. Image quality was evaluated on altering various imaging parameters in CS and PI so that the scan time was adjusted to 10 and 6 s within a single breath-holding. Normalized standard deviation (nSD = SD/mean value) and signal-to-noise ratio (SNR = mean value/SD) of liver signal intensity were measured. Visual scores for the outline of the liver and inferior right hepatic vein (IRHV) were evaluated using a 4-point scale and compared with that of the reference standard (20 s scan without CS). RESULTS: The nSD and SNR were not significantly different when the 10 s scan with CS factor 2.0 and the 6 s scan with CS factor 2.0 and 2.5 were compared to the 20 s scan. Overall visual score (mean score of the outline of the liver and IRHV) was significantly better (p < 0.05) with the 10 s scan with CS factor 2.0 compared to the other scan protocols. CONCLUSION: The 10 s scan with CS factor 2.0 should be recommended for high temporal resolution MR imaging of the liver using CS and PI in a 1.5 T MR system. ADVANCES IN KNOWLEDGE: This study conducts a novel MR imaging of the liver using CS and PI in a 1.5 T MR system.

7.
Jpn J Radiol ; 36(11): 649-660, 2018 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-30173283

RESUMO

PURPOSE: To assess whether the modified reading system "Triage Reader" (TR) can improve the radiological reading work environment. MATERIALS AND METHODS: This retrospective, single-center study analyzed two reading systems for 26,786 computed tomography and magnetic resonance imaging examinations. In the conventional system (January 1-May 31, 2016), all reading work was mostly completed within the day. In the TR system (January 1-May 31, 2017), a radiology resident (TR) first read every image immediately after the examination and tagged each examination according to actual image findings and clinical demands. Routine reading work was finished when all high-priority cases were completed. Low-priority cases were assessed the following day. RESULTS: When using the TR system, the mean reading number in the evening decreased (P = 0.009). The mean elapsed time to finalize report of case with actual urgent image finding shortened from 4.26 to 1.97 h (P < 0.0001). The mean number of cases experienced per resident increased from 5.4 to 28.7 (P < 0.001). Subjective evaluation revealed a significant improvement in "Reading efficiency" and "Contribution to clinical practice." CONCLUSION: Introduction of the TR system can improve the reading efficiency and quality, educational effect among residents by increasing the number of experienced cases and work satisfaction.


Assuntos
Erros de Diagnóstico/prevenção & controle , Internato e Residência/métodos , Imageamento por Ressonância Magnética/métodos , Radiologia/educação , Tomografia Computadorizada por Raios X/métodos , Triagem/métodos , Humanos , Estudos Retrospectivos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA