Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
1.
Turk J Phys Med Rehabil ; 68(3): 426-429, 2022 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-36475108

RESUMO

One of the most important perceptual function disorders following a cerebrovascular accident (CVA) is the unilateral hemispatial neglect phenomenon (UHNP). In this case report, we present a 73-year-old male patient with UHNP accompanying right hemiplegia, which was identified with detailed examination. Clinical picture was characterized by right-sided hemiparesis in the upper right shoulder and relative weakness in the right leg. Patient was tested on hemineglect (HN) with star cancellation test and detailed neuropsychological evaluation. This article highlight the latest findings regarding the cognitive-behavioral syndrome of neglect for hemiplegia that occur following left hemisphere stroke.

2.
Turk J Phys Med Rehabil ; 67(3): 357-364, 2021 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-34870124

RESUMO

OBJECTIVES: This study aims to assess the sciatic nerve (SN), common peroneal nerve (CPN), and tibial nerve (TN) by ultrasound in patients with traumatic lower limb amputation (LLA) and to examine the possible relationship between ultrasonographic and clinical findings. PATIENTS AND METHODS: This cross-sectional study included a total of 33 male patients (mean age: 36.6±8.7 years; range, 21 to 48 years) who had LLA due to traumatic injury between May 2019 and April 2020. Amputation and prosthesis use and functional K level of activity were recorded. Ultrasound examinations were performed to measure the cross-sectional areas (CSAs) of the SN, CPN, and TN bilaterally at the same levels. The values from the normal sides were accepted as controls. RESULTS: The CSA values were greater on the amputated sides than the non-amputated sides for SN (p=0.001), TN (p=0.001), and CPN (p=0.015), regardless of the activity level. The amputated side SN (p=0.001), TN (p=0.001), and CPN (p=0.016) were thicker in patients with level of K4 activity than the non-amputated side. For the patients with K3 activity level, larger TN CSA values were determined on the amputated side, compared to those at the K4 level (p=0.035). The SN was found to be greater in patients using microprocessor-controlled knee prosthesis (p=0.032) and TN was larger in hypobaric sealing membrane users on the amputated sides (p=0.041). CONCLUSION: The SN, CPN, and TN were found to be larger in all patients on the amputated sides and in patients with K4 activity level. Based on these findings, the K3 activity level and the use of hypobaric sealing membrane seems to affect the CSA values of TN. Additionally, the use of microprocessor knee prosthesis affects the CSA values of SN. We believe that these results may be essential for the analysis or prediction of lower extremity nerve involvement according to the K activity level and the use of prosthesis in patients with traumatic LLA.

3.
Eur J Cancer Care (Engl) ; 30(2): e13376, 2021 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-33219612

RESUMO

OBJECTIVE: To determine the role of ultrasonography in the follow-up of effectiveness of complex decongestive therapy (CDT) in different subgroups of patients with breast cancer-related lymphoedema (BCRL). METHODS: Forty-seven patients with unilateral upper BCRL were enrolled in the study. The patient group was divided into two subgroups according to body mass index (BMI) as obese and non-obese and three subgroups according to International Society of Lymphology staging. All patients underwent CDT, the circumference measurements and ultrasonographic soft tissue thicknesses evaluations were performed at two anatomic sites, and upper extremity limb volumes were calculated using the truncated cone formula before and after CDT. RESULTS: There were significant decreases in both circumferential measurements and ultrasonographic soft tissue thicknesses in non-obese patients and stage 2 lymphoedema patients after 15 sessions of CDT. The ultrasonographic soft tissue thickness values were correlated with the upper arm and forearm circumference values before (r = 0.491, p < .001, r = 0.841, p < .001, respectively) and after (r = 0.535, p < .001, r = 0.714, p < .001, respectively) CDT. CONCLUSIONS: Ultrasonography presents as a reliable method to measure the soft tissue thickness and treatment efficacy after CDT in only non-obese and stage 2 patients with BCRL.


Assuntos
Linfedema Relacionado a Câncer de Mama , Neoplasias da Mama , Linfedema , Linfedema Relacionado a Câncer de Mama/diagnóstico por imagem , Linfedema Relacionado a Câncer de Mama/terapia , Neoplasias da Mama/complicações , Neoplasias da Mama/diagnóstico por imagem , Neoplasias da Mama/terapia , Feminino , Seguimentos , Humanos , Linfedema/diagnóstico por imagem , Linfedema/etiologia , Linfedema/terapia , Ultrassonografia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA