Int J Mol Sci ; 24(21)2023 Oct 28.
Artigo em Inglês | MEDLINE | ID: mdl-37958688

RESUMO

COVID-19 has highlighted challenges in the measurement quality and comparability of serological binding and neutralization assays. Due to many different assay formats and reagents, these measurements are known to be highly variable with large uncertainties. The development of the WHO international standard (WHO IS) and other pool standards have facilitated assay comparability through normalization to a common material but does not provide assay harmonization nor uncertainty quantification. In this paper, we present the results from an interlaboratory study that led to the development of (1) a novel hierarchy of data analyses based on the thermodynamics of antibody binding and (2) a modeling framework that quantifies the probability of neutralization potential for a given binding measurement. Importantly, we introduced a precise, mathematical definition of harmonization that separates the sources of quantitative uncertainties, some of which can be corrected to enable, for the first time, assay comparability. Both the theory and experimental data confirmed that mAbs and WHO IS performed identically as a primary standard for establishing traceability and bridging across different assay platforms. The metrological anchoring of complex serological binding and neuralization assays and fast turn-around production of an mAb reference control can enable the unprecedented comparability and traceability of serological binding assay results for new variants of SARS-CoV-2 and immune responses to other viruses.


Assuntos
COVID-19 , SARS-CoV-2 , Humanos , Anticorpos Monoclonais , Bioensaio , Análise de Dados , Anticorpos Antivirais , Anticorpos Neutralizantes
2.
Int J Mol Sci ; 24(15)2023 Aug 02.
Artigo em Inglês | MEDLINE | ID: mdl-37569707

RESUMO

COVID-19 is an ongoing, global pandemic caused by the novel, highly infectious SARS-CoV-2 virus. Efforts to mitigate the effects of SARS-CoV-2, such as mass vaccination and development of monoclonal therapeutics, require precise measurements of correlative, functional neutralizing antibodies that block virus infection. The development of rapid, safe, and easy-to-use neutralization assays is essential for faster diagnosis and treatment. Here, we developed a vesicular stomatitis virus (VSV)-based neutralization assay with two readout methods, imaging and flow cytometry, that were capable of quantifying varying degrees of neutralization in patient serum samples. We tested two different spike-pseudoviruses and conducted a time-course assay at multiple multiplicities of infection (MOIs) to optimize the assay workflow. The results of this assay correlate with the results of previously developed serology and surrogate neutralization assays. The two pseudovirus readout methods produced similar values of 50% neutralization titer values. Harvest-free in situ readouts for live-cell imaging and high-throughput analysis results for flow cytometry can provide unique capabilities for fast evaluation of neutralization, which is critical for the mitigation of future pandemics.


Assuntos
COVID-19 , SARS-CoV-2 , Humanos , Citometria de Fluxo , Anticorpos Antivirais , Testes de Neutralização/métodos , Anticorpos Neutralizantes
3.
Nanomaterials (Basel) ; 12(18)2022 Sep 08.
Artigo em Inglês | MEDLINE | ID: mdl-36144906

RESUMO

The number of techniques to measure number concentrations and size distributions of submicrometer particles has recently increased. Submicrometer particle standards are needed to improve the accuracy and reproducibility of these techniques. The number concentrations of fluorescently labeled polystyrene submicrometer sphere suspensions with nominal 100 nm, 200 nm and 500 nm diameters were measured using seven different techniques. Diameter values were also measured where possible. The diameter values were found to agree within 20%, but the number concentration values differed by as much as a factor of two. Accuracy and reproducibility related with the different techniques are discussed with the goal of using number concentration standards for instrument calibration. Three of the techniques were used to determine SI-traceable number concentration values, and the three independent values were averaged to give consensus values. This consensus approach is proposed as a protocol for certifying SI-traceable number concentration standards.

4.
Int J Mol Sci ; 22(15)2021 Jul 31.
Artigo em Inglês | MEDLINE | ID: mdl-34361020

RESUMO

A stochastic model of the flow cytometer measurement process was developed to assess the nature of the observed coefficient of variation (CV%) of the mean fluorescence intensity (MFI) from a population of labeled microspheres (beads). Several sources of variability were considered: the total number of labels on a bead, the path through the laser beam, the optical absorption cross-section, the quantum yield, the numerical aperture of the collection optics, and the photoelectron conversion efficiency of the photomultiplier (PMT) cathode. The variation in the number of labels on a bead had the largest effect on the CV% of the MFI of the bead population. The variation in the path of the bead through the laser beam was minimized using flat-top lasers. The variability in the average optical properties of the labels was of minor importance for beads with sufficiently large number of labels. The application of the bead results to the measured CV% of labeled B cells indicated that the measured CV% was a reliable measure of the variability of antibodies bound per cell. With some modifications, the model can be extended to multicolor flow cytometers and to the study of CV% from cells with low fluorescence signal.


Assuntos
Linfócitos B/citologia , Citometria de Fluxo/normas , Microesferas , Análise de Variância , Citometria de Fluxo/métodos , Humanos , Reprodutibilidade dos Testes , Processos Estocásticos
5.
Int J Mol Sci ; 22(5)2021 Mar 08.
Artigo em Inglês | MEDLINE | ID: mdl-33800363

RESUMO

Quantitative and robust serology assays are critical measurements underpinning global COVID-19 response to diagnostic, surveillance, and vaccine development. Here, we report a proof-of-concept approach for the development of quantitative, multiplexed flow cytometry-based serological and neutralization assays. The serology assays test the IgG and IgM against both the full-length spike antigens and the receptor binding domain (RBD) of the spike antigen. Benchmarking against an RBD-specific SARS-CoV IgG reference standard, the anti-SARS-CoV-2 RBD antibody titer was quantified in the range of 37.6 µg/mL to 31.0 ng/mL. The quantitative assays are highly specific with no correlative cross-reactivity with the spike proteins of MERS, SARS1, OC43 and HKU1 viruses. We further demonstrated good correlation between anti-RBD antibody titers and neutralizing antibody titers. The suite of serology and neutralization assays help to improve measurement confidence and are complementary and foundational for clinical and epidemiologic studies.


Assuntos
Teste Sorológico para COVID-19/métodos , Teste Sorológico para COVID-19/normas , COVID-19/sangue , COVID-19/imunologia , Testes de Neutralização/métodos , Testes de Neutralização/normas , SARS-CoV-2/imunologia , Anticorpos Neutralizantes/sangue , Anticorpos Neutralizantes/imunologia , Anticorpos Antivirais/sangue , Anticorpos Antivirais/imunologia , Reações Cruzadas , Citometria de Fluxo/métodos , Fluorescência , Humanos , Imunoglobulina G/sangue , Imunoglobulina G/imunologia , Imunoglobulina M/sangue , Imunoglobulina M/imunologia , Microesferas , Receptores Virais/química , Receptores Virais/imunologia , Glicoproteína da Espícula de Coronavírus/química , Glicoproteína da Espícula de Coronavírus/imunologia
6.
Int J Mol Sci ; 21(17)2020 Aug 24.
Artigo em Inglês | MEDLINE | ID: mdl-32846978

RESUMO

A stochastic reaction-diffusion model was developed to describe the binding of labeled monoclonal antibodies (mAbs) to CD4 receptors on the surface of T cells. The mAbs diffused to, adsorbed on, and underwent monovalent and bivalent binding to CD4 receptors on the cell surface. The model predicted the time-dependent nature of all populations involved in the labeling process. At large time, the populations reached equilibrium values, giving the number of antibodies bound to the T cell (ABC) defined as the sum of monovalently and bivalently bound mAbs. The predicted coefficient of variation (CV%) of the (ABC) values translated directly to a corresponding CV% of the measured mean fluorescence intensity (MFI). The predicted CV% was about 0.2% from the intrinsic fluctuations of the stochastic reaction process, about 5% after inclusion of the known fluctuations in the number of available CD4 receptors, and about 11% when fluctuations in bivalent binding affinity were included. The fluorescence detection process is expected to contribute approximately 7%. The abovementioned contributions to CV% sum up to approximately 13%. Work is underway to reconcile the predicted values and the measured values of 17% to 22%.


Assuntos
Anticorpos Monoclonais/metabolismo , Antígenos CD4/metabolismo , Modelos Teóricos , Linfócitos T/metabolismo , Afinidade de Anticorpos , Células Cultivadas , Difusão , Humanos , Ligação Proteica , Processos Estocásticos , Especificidade por Substrato
7.
Cytometry B Clin Cytom ; 96(6): 508-513, 2019 11.
Artigo em Inglês | MEDLINE | ID: mdl-30790450

RESUMO

BACKGROUND: Over 2,000 people a year in the United Kingdom need a bone marrow or blood stem cell transplant. It is important to accurately quantify the hematopoietic stem cells to predict whether the transplant will be successful in replenishing the immune system. However, they are present at low frequency, which complicates accurate quantification. The current gold standard method is single-platform flow cytometry using internal reference counting beads to determine the concentration of CD34 cells. However, volumetric flow cytometers have the ability to measure the acquisition volume, which removes the need for reference beads for calculation of cell concentrations. METHOD: In this study, we compared both methods for calculating CD34 cell concentrations in volumetric cytometers, using either the volume reading or the number of reference beads for calculation. In addition, the uncertainty of measurement for each method was estimated. RESULTS: The results show that both methods have similar uncertainties of measurement. Regression analysis showed low to no statistical difference in CD34 cell concentrations obtained with each method. CONCLUSIONS: Overall, this study suggests that the volumetric method is a valid approach but that the adoption of this technology may be hindered without some form of external calibration of volume readings to increase confidence in the measurement. © 2019 The Authors. Cytometry Part B: Clinical Cytometry published by Wiley Periodicals, Inc. on behalf of International Clinical Cytometry Society.


Assuntos
Antígenos CD34/análise , Citometria de Fluxo , Células-Tronco Hematopoéticas/citologia , Contagem de Células , Humanos , Análise de Regressão
8.
Artigo em Inglês | MEDLINE | ID: mdl-34877142

RESUMO

The CD4 glycoprotein is a component of the T cell receptor complex which plays an important role in the human immune response. This manuscript describes the measurement and modeling of the binding of fluorescently labeled anti-human CD4 monoclonal antibodies (mAb; SK3 clone) to CD4 receptors on the surface of human peripheral blood mononuclear cells (PBMC). CD4 mAb fluorescein isothiocyanate (FITC) and CD4 mAb allophycoerythrin (APC) conjugates were obtained from commercial sources. Four binding conditions were performed, each with the same PBMC sample and different CD4 mAb conjugate. Each binding condition consisted of the PBMC sample incubated for 30 min in labeling solutions containing progressively larger concentrations of the CD4 mAb-label conjugate. After the incubation period, the cells were re-suspended in PBS-based buffer and analyzed using a flow cytometer to measure the mean fluorescence intensity (MFI) of the labeled cell populations. A model was developed to estimate the equilibrium concentration of bound CD4 mAb-label conjugates to CD4 receptors on PBMC. A set of parameters was obtained from the best fit of the model to the measured MFI data and the known number of CD4 receptors on PBMC surface. Divalent and monovalent binding had to be invoked for the APC and FITC CD4 mAb conjugates, respectively. This suggests that the mAb binding depends on the size of the label, which has significant implications for quantitative flow cytometry. The study supports the National Institute of Standards and Technology program to develop quantitative flow cytometry measurements.

9.
Methods Mol Biol ; 1678: 93-110, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-29071677

RESUMO

Multicolor flow cytometer assays are routinely used in clinical laboratories for immunophenotyping, monitoring disease and treatment, and determining prognostic factors. However, existing methods for quantitative measurements have not yet produced satisfactory results independent of flow cytometers used. This chapter details a procedure for quantifying surface and intracellular protein biomarkers by calibrating the output of a multicolor flow cytometer in units of antibodies bound per cell (ABC). The procedure includes the following critical steps: (a) quality control (QC) and performance characterization of the multicolor flow cytometer, (b) fluorescence calibration using hard dyed microspheres assigned with fluorescence intensity values in equivalent number of reference fluorophores (ERF), (c) compensation for correction of fluorescence spillover, and (d) application of a biological reference standard for translating the ERF scale to the ABC scale. The chapter also points out current efforts for implementing quantification of biomarkers in a manner which is independent of instrument platforms and reagent differences.


Assuntos
Citometria de Fluxo/métodos , Anticorpos , Linfócitos T CD4-Positivos/metabolismo , Calibragem , Citometria de Fluxo/normas , Corantes Fluorescentes , Humanos , Imunofenotipagem , Microesferas , Controle de Qualidade , Padrões de Referência
10.
Curr Protoc Cytom ; 75: 1.29.1-1.29.14, 2016 Jan 06.
Artigo em Inglês | MEDLINE | ID: mdl-26742654

RESUMO

Multicolor flow cytometer assays with fluorescently labeled antibodies are routinely used in clinical laboratories to measure the cell number of specific immunophenotypes and to estimate expression levels of specific receptors/antigens either on the cell surface or intracellularly. The cell number and specific receptors/antigens serve as biomarkers for pathological conditions at various stages of a disease. Existing methods and cell reference materials for quantitative expression measurements have not yet produced results that are of wide clinical interest or are instrument-independent across all fluorescence channels. This unit details a procedure for quantifying surface and intracellular biomarkers by calibrating the output of a multicolor flow cytometer in units of antibody bound per cell (ABC). The procedure includes (1) quality control of the flow cytometer, (2) fluorescence intensity calibration using hard dyed microspheres assigned with fluorescence intensity values, (3) compensation for fluorescence spillover between adjacent fluorescence channels, and (4) application of a biological reference calibrator to establish an ABC scale. The unit also points out current efforts for quantifying biomarkers in a manner that is independent of instrument platforms and reagent differences.


Assuntos
Anticorpos/química , Antígenos CD4/análise , Linfócitos T CD4-Positivos/citologia , Linfócitos T CD4-Positivos/imunologia , Citometria de Fluxo/métodos , Imunofenotipagem/métodos , Antígenos CD20/análise , Biomarcadores/análise , Linfócitos T CD8-Positivos/citologia , Calibragem , Cor , Humanos , Antígenos Comuns de Leucócito/análise , Controle de Qualidade , Espectrometria de Fluorescência
11.
J Res Natl Inst Stand Technol ; 121: 264-281, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-34434623

RESUMO

A procedure will be described to assign to each dyed microsphere a number called the Equivalent number of Reference Fluorophores (ERF). The ERF unit gives the number of reference fluorophores in solution which produce the same fluorescence signal as a single dyed microsphere. In the first step, fluorescence measurements were carried out on serial dilutions of a solution of reference fluorophores. The resulting fluorescence intensities and the corresponding concentrations were used to calibrate the response of the fluorometer. The calibration consisted of establishing a linear relation between the intensities and concentrations. In the second step, the fluorescence intensity from a suspension of microspheres was measured in order to determine the equivalent concentration of reference fluorophores which gave the same fluorescence intensity as the suspension of microspheres. This was performed by utilizing the calibration line obtained in the first step. In the third step, a flow cytometer and a light obscuration apparatus were used to measure the total concentration of microspheres in the suspensions used for the fluorescence measurements. In addition to the total microsphere concentration, the flow cytometer also enabled the measurement of the concentration of a sub population of microspheres which are used to calibrate the fluorescence scale of a flow cytometer. The fourth step utilized the data collected in steps one, two, and three to assign a value of ERF to individual microspheres. The set of microspheres with assigned ERF values will be used to establish a linear fluorescence scale in each channel of a flow cytometer. The discussion will emphasize the estimate of uncertainties in each step of the assignment process.

12.
Cytometry B Clin Cytom ; 90(2): 159-67, 2016 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-26013593

RESUMO

Detecting changes in the expression levels of cell antigens could provide critical information for the diagnosis of many diseases, for example, leukemia, lymphoma, and immunodeficiency diseases, detecting minimal residual disease, monitoring immunotherapies and discovery of meaningful clinical disease markers. One of the most significant challenges in flow cytometry is how to best ensure measurement quality and generate consistent and reproducible inter-laboratory and intra-laboratory results across multiple cytometer platforms and locations longitudinally over time. In a previous study, we developed a procedure for instrument standardization across four different flow cytometer platforms from the same manufacturer. CD19 quantification was performed on three of the standardized instruments relative to CD4 expression on T lymphocytes with a known amount of antibody bound per cell (ABC) as a quantification standard. Consistent and reliable measures of CD19 expression were obtained independent of fluorochrome used demonstrating the utility of this approach. In the present investigation, quantification of CD20 relative to CD4 reference marker was implemented within a single tube containing both antibodies. Relative quantification of CD20 was performed using anti-CD20 antibody (clone L27) in three different fluorochromes relative to anti-CD4 antibody (clone SK3). Our results demonstrated that cell surface marker quantification can be performed robustly using the single tube assay format with novel gating strategies. The ABC values obtained for CD20 expression levels using PE, APC, or PerCP Cy5.5 are consistent over the five different instrument platforms for any given apparently healthy donor independent of the fluorochrome used.


Assuntos
Anticorpos Monoclonais/uso terapêutico , Antígenos CD20/isolamento & purificação , Antígenos CD4/isolamento & purificação , Citometria de Fluxo , Anticorpos Monoclonais/imunologia , Antígenos CD19/imunologia , Antígenos CD19/isolamento & purificação , Antígenos CD20/imunologia , Antígenos CD4/imunologia , Linfócitos T CD4-Positivos/imunologia , Corantes Fluorescentes , Humanos , Contagem de Linfócitos , Ligação Proteica/imunologia
13.
Cytometry A ; 87(3): 244-53, 2015 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-25655255

RESUMO

A surface-labeled lyophilized lymphocyte (sLL) preparation has been developed using human peripheral blood mononuclear cells prelabeled with a fluorescein isothiocyanate conjugated anti-CD4 monoclonal antibody. The sLL preparation is intended to be used as a reference material for CD4+ cell counting including the development of higher order reference measurement procedures and has been evaluated in the pilot study CCQM-P102. This study was conducted across 16 laboratories from eight countries to assess the ability of participants to quantify the CD4+ cell count of this reference material and to document cross-laboratory variability plus associated measurement uncertainties. Twelve different flow cytometer platforms were evaluated using a standard protocol that included calibration beads used to obtain quantitative measurements of CD4+ T cell counts. There was good overall cross-platform and counting method agreement with a grand mean of the laboratory calculated means of (301.7 ± 4.9) µL(-1) CD4+ cells. Excluding outliers, greater than 90% of participant data agreed within ±15%. A major contribution to variation of sLL CD4+ cell counts was tube to tube variation of the calibration beads, amounting to an uncertainty of 3.6%. Variation due to preparative steps equated to an uncertainty of 2.6%. There was no reduction in variability when data files were centrally reanalyzed. Remaining variation was attributed to instrument specific differences. CD4+ cell counts obtained in CCQM-P102 are in excellent agreement and show the robustness of both the measurements and the data analysis and hence the suitability of sLL as a reference material for interlaboratory comparisons and external quality assessment.


Assuntos
Linfócitos T CD4-Positivos , Fluoresceína-5-Isotiocianato , Leucócitos Mononucleares , Fenótipo , Anticorpos/análise , Contagem de Linfócito CD4/métodos , Contagem de Linfócito CD4/normas , Linfócitos T CD4-Positivos/química , Fluoresceína-5-Isotiocianato/análise , Liofilização/métodos , Humanos , Leucócitos Mononucleares/química , Projetos Piloto
14.
J Res Natl Inst Stand Technol ; 119: 610-28, 2014.
Artigo em Inglês | MEDLINE | ID: mdl-26601047

RESUMO

Measurements are presented of the absorbance, fluorescence emission, fluorescence quantum yield, and fluorescence lifetime of CdSe/ZnS nanocrystals, also known as quantum dots (QDs). The study included three groups of nanocrystals whose surfaces were either passivated with organic molecules, modified further with carboxyl groups, or conjugated with CD14 mouse anti-human antibodies. The surface modifications had observable effects on the optical properties of the nanocrystals. The oscillator strength (OS) of the band edge transition was about 1.0 for the nanocrystals emitting at 565 nm, 605 nm, and 655 nm. The OS could not be determined for QDs with emission at 700 nm and 800 nm. The fluorescence lifetimes varied from 26 ns for nanocrystals emitting near 600 nm to 150 ns for nanocrystals emitting near 800 nm. The quantum yield ranged between 0.4 and 0.9 for the nanocrystals in this study. A brightness index (BI) was used to evaluate the suitability of the nanocrystal labels for flow cytometer measurements. Most QD labels are at least as bright as fluorescein for applications in flow cytometer assays with 488 nm excitation. For optimal brightness the QDs should be excited with 405 nm light. We observed a strong dependence of the QD absorbance at 250 nm on the surface modification of the QD.

15.
Artigo em Inglês | MEDLINE | ID: mdl-26401422

RESUMO

Measurements of absorbance and fluorescence emission were carried out on aqueous suspensions of polystyrene (PS) microspheres with a diameter of 2.5 µm using a spectrophotometer with an integrating sphere detector. The apparatus and the principles of measurements were described in our earlier publications. Microspheres with and without green BODIPY(@) dye were measured. Placing the suspension inside an integrating sphere (IS) detector of the spectrophotometer yielded (after a correction for fluorescence emission) the absorbance (called A in the text) due to absorption by BODIPY(@) dye inside the microsphere. An estimate of the absorbance due to scattering alone was obtained by subtracting the corrected BODIPY(@) dye absorbance (A) from the measured absorbance of a suspension placed outside the IS detector (called A1 in the text). The absorption of the BODIPY(@) dye inside the microsphere was analyzed using an imaginary index of refraction parameterized with three Gaussian-Lorentz functions. The Kramer-Kronig relation was used to estimate the contribution of the BODIPY(@) dye to the real part of the microsphere index of refraction. The complex index of refraction, obtained from the analysis of A, was used to analyze the absorbance due to scattering ((A1 - A) in the text). In practice, the analysis of the scattering absorbance, A1-A, and the absorbance, A, was carried out in an iterative manner. It was assumed that A depended primarily on the imaginary part of the microsphere index of refraction with the other parameters playing a secondary role. Therefore A was first analyzed using values of the other parameters obtained from a fit to the absorbance due to scattering, A1-A, with the imaginary part neglected. The imaginary part obtained from the analysis of A was then used to reanalyze A1-A, and obtain better estimates of the other parameters. After a few iterations, consistent estimates were obtained of the scattering and absorption cross sections in the wavelength region 300 nm to 800 nm.

16.
Cytometry A ; 81(7): 567-75, 2012 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-22539147

RESUMO

To transform the linear fluorescence intensity scale obtained with fluorescent microspheres to an antibody bound per cell (ABC) scale, a biological cell reference material is needed. Optimally, this material should have a reproducible and tight ABC value for the expression of a known clinical reference biomarker. In this study, we characterized commercially available cryopreserved peripheral blood mononuclear cells (PBMCs) and two lyophilized PBMC preparations, Cyto-Trol and PBMC-National Institute for Biological Standard and Control (NIBSC) relative to freshly prepared PBMC and whole blood samples. It was found that the ABC values for CD4 expression on cryopreserved PBMC were consistent with those of freshly obtained PBMC and whole blood samples. By comparison, the ABC value for CD4 expression on Cyto-Trol is lower and the value on PBMC-NIBSC is much lower than those of freshly prepared cell samples using both conventional flow cytometry and CyTOF™ mass cytometry. By performing simultaneous surface and intracellular staining measurements on these two cell samples, we found that both cell membranes are mostly intact. Moreover, CD4(+) cell diameters from both lyophilized cell preparations are smaller than those of PBMC and whole blood. This could result in steric interference in antibody binding to the lyophilized cells. Further investigation of the fixation effect on the detected CD4 expression suggests that the very low ABC value obtained for CD4(+) cells from lyophilized PBMC-NIBSC is largely due to paraformaldehyde fixation; this significantly decreases available antibody binding sites. This study provides confirmation that the results obtained from the newly developed mass cytometry are directly comparable to the results from conventional flow cytometry when both methods are standardized using the same ABC approach.


Assuntos
Antígenos/metabolismo , Linfócitos T CD4-Positivos/metabolismo , Citometria de Fluxo , Calibragem , Membrana Celular/metabolismo , Separação Celular , Fixadores/química , Formaldeído/química , Humanos , Permeabilidade , Polímeros/química , Coloração e Rotulagem , Fixação de Tecidos
17.
Methods Mol Biol ; 699: 53-65, 2011.
Artigo em Inglês | MEDLINE | ID: mdl-21116978

RESUMO

Multicolor flow cytometer assays are routinely used in clinical laboratories for immunophenotyping, -monitoring disease and treatment, and determining prognostic factors. However, existing methods for quantitative measurements have not yet produced satisfactory results. This chapter details a procedure for quantifying surface and intracellular protein biomarkers by calibrating the output of a multicolor flow cytometer in units of antibodies bound per cell (ABC). The procedure includes the following critical steps (a) quality control (QC) of the multicolor flow cytometer, (b) fluorescence calibration using hard dyed microspheres assigned with fluorescence intensity values in equivalent number of reference fluorophores (ERF), (c) compensation for correction of fluorescence spillover, and (d) application of a biological reference standard for translating the ERF scale to the ABC scale. The chapter also points out current efforts for implementing quantification of biomarkers in a manner which is independent of instrument platforms and reagent differences.


Assuntos
Citometria de Fluxo/métodos , Anticorpos/imunologia , Células Sanguíneas/imunologia , Calibragem , Separação Celular/métodos , Fluorescência , Humanos , Controle de Qualidade , Padrões de Referência , Reprodutibilidade dos Testes
18.
J Res Natl Inst Stand Technol ; 116(3): 671-83, 2011.
Artigo em Inglês | MEDLINE | ID: mdl-26989591

RESUMO

A procedure is described for assigning the number of equivalent reference fluorophores (ERF) values to microspheres labeled with a fluorophore designed to produce a fluorescence response in a given fluorescence channel of a multicolor flow cytometer. A fluorimeter was calibrated by a series of solutions of the reference fluorophores. The fluorimeter was used to obtain the microsphere fluorescence intensity, and a multicolor flow cytometer was used to obtain the microsphere concentration. The microsphere fluorescence intensity and the concentration were used to obtain the value of ERF for each model microsphere calibration standard. The procedure is described in detail only for microspheres with allophycocyanin (APC) immobilized on the surface. ERF values were also determined for microsphere calibrators for three other fluorescence channels: fluorescein isothiocyanate (FITC), phycoerythrin (PE), and Pacific Blue(PB). The four model microsphere calibrators provide a one point calibration for the four channels of a flow cytometer. By using software controls and changing the photomultiplier voltages, it is possible to obtain a multipoint calibration for each fluorescence channel using each microsphere calibrator.

19.
Clin Chem Lab Med ; 46(7): 1033-45, 2008.
Artigo em Inglês | MEDLINE | ID: mdl-18605964

RESUMO

BACKGROUND: Immunoassays allow the specific detection and quantitation of biological molecules in complex samples at physiologically relevant concentrations. However, there are concerns over the comparability of such techniques when the same assay is performed by different operators or laboratories. An international intercomparison study was performed to assess the uncertainty involved in the estimation of a protein cytokine concentration using a fluorescent ELISA. METHODS: The intercomparison study method was based on a non-competitive sandwich immunoassay with an enhancement step to generate a fluorescent readout. The intercomparison was performed in two phases, with the uncertainty of the instrument determined separately from that of the assay. The 11 laboratories participating in the study represented national metrology institutes or nominated expert laboratories. RESULTS: Participants were asked to determine an undisclosed concentration of interferon using a supplied standard. The mean participant estimate and experimental standard deviation of the mean was 3.54+/-0.22 mg/L, with the spread of data ranging around +/-35% of the mean. The quantitation range of the ELISA and of participants' instruments displayed large variation that contributed to the overall uncertainty. CONCLUSIONS: Identified sources of uncertainty within the ELISA methodology included pipetting, data fitting, model selection and instrument/plate variation.


Assuntos
Ensaio de Imunoadsorção Enzimática/métodos , Interferon-alfa/análise , Humanos , Interferon alfa-2 , Proteínas Recombinantes/análise , Sensibilidade e Especificidade , Incerteza
20.
Cytometry A ; 73(4): 279-88, 2008 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-18163471

RESUMO

A procedure is presented for calibrating the output of a multicolor flow cytometer in units of antibodies bound per cell (ABC). The procedure involves two steps. First, each of the fluorescence channels of the flow cytometer is calibrated using Ultra Rainbow beads with assigned values of equivalent number of reference fluorophores (ERF). The objective of this step is to establish a linear relation between the fluorescence signal in a given fluorescence channel of multicolor flow cytometers and the value of ERF. The second step involves a biological standard such as a lymphocyte with a known number of antibody binding sites (e.g., CD4 binding sites). The biological standard is incubated with antibodies labeled with one type of fluorophores for a particular fluorescence channel and serves to translate the ERF scale to an ABC scale. A significant part of the two-step calibration procedure involves the assignment of ERF values to the different populations of Ultra Rainbow beads. The assignment of ERF values quantifies the relative amount of embedded fluorophore mixture in each bead population. It is crucial to insure that the fluorescence signal in a given range of fluorescence emission wavelengths is related linearly to the assigned values of ERF. The biological standard has to poses a known number of binding sites for a given antibody. In addition, this antibody has to be amenable to labeling with different types of fluorophores associated with various fluorescence channels. The present work suggests that all of the requirements for a successful calibration of a multicolor flow cytometer in terms of ABC values can be fulfilled. The calibration procedure is based on firm scientific foundations so that it is easy to envision future improvements in accuracy and ease of implementation.


Assuntos
Citometria de Fluxo/métodos , Sítios de Ligação , Calibragem , Separação Celular/métodos , Desenho de Equipamento , Fluorescência , Corantes Fluorescentes , Microesferas , Reprodutibilidade dos Testes , Espectrometria de Fluorescência/métodos