Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 102
Filtrar
1.
J Invasive Cardiol ; 2024 May 20.
Artigo em Inglês | MEDLINE | ID: mdl-38776474

RESUMO

An 87-year-old man with a history of heart failure and a modified bio-Bentall Mitroflow 23-mm bioprosthesis (Sorin) was referred to our institution for critical aortic stenosis, which was confirmed by transesophageal echocardiography. Pre-procedural computed tomography revealed slightly calcified bioprosthesis leaflets, adequate coronary ostia height, and a slightly angled Bentall tube graft measuring 29 mm in diameter at the aortic anastomosis .

2.
J Clin Med ; 13(10)2024 May 09.
Artigo em Inglês | MEDLINE | ID: mdl-38792321

RESUMO

Background: The usefulness of drug-eluting balloons (DEBs) has not been fully elucidated in calcified coronary lesions (CCLs). This meta-analysis aimed to evaluate the efficacy of DEBs compared to a drug-eluting stent (DES) in this setting. Methods: PubMed, EMBASE and Cochrane were searched through December 2023. The primary endpoint was 12 months major adverse cardiac events (MACE). Secondary endpoints included clinical outcomes and angiographic results after PCI and at a 12-month follow-up. Results: Five studies and a total of 1141 patients with 1176 coronary lesions were included. Overall, the DEB was comparable to DES in MACE (RR = 0.86, 95% CI: 0.62-1.19, p = 0.36), cardiac death (RR = 0.59, 95% CI: 0.23-1.53, p = 0.28), myocardial infarction (RR = 0.89, 95% CI: 0.25-3.24, p = 0.87) and target lesion revascularization (RR = 1.1, 95% CI: 0.68-1.77, p = 0.70). Although the DEB was associated with worse acute angiographic outcomes (acute gain; MD = -0.65, 95% CI: -0.73, -0.56 and minimal lumen diameter; MD = -0.75, 95% CI: -0.89, -0.61), it showed better results at 12 months follow-up (late lumen loss; MD = -0.34, 95% CI: -0.62, -0.07). Conclusions: This meta-analysis showed that the DEB strategy is comparable to DES in the treatment of CCLs in terms of clinical outcomes. Although the DEB strategy had inferior acute angiographic results, it may offer better angiographic results at follow-up.

3.
Catheter Cardiovasc Interv ; 103(6): 1015-1022, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38577931

RESUMO

BACKGROUND: Previous studies have documented a high rate of implantation success with the ACURATE neo2 valve, as well as a reduction in paravalvular leak (PVL) compared to its predecessor, the ACURATE neo. However, there are no studies that have reviewed and compared the long-term clinical and hemodynamic outcomes of these patients. AIMS: This study aimed to evaluate the results of the ACURATE neo transcatheter aortic valve in a real-world context, and to compare the results of the outcomes of both generations of this device (ACURATE neo and ACURATE neo2), with a specific focus on procedural success, safety, and long-term effectiveness. METHODS: A prospective study including all consecutive patients treated with the ACURATE neo device in seven hospitals was conducted (Clinical Trials Identification Number: NCT03846557). The primary endpoint consisted of a composite of adverse events, including mortality, aortic insufficiency, and other procedural complications. As the second-generation device (ACURATE neo2) replaced the ACURATE neo during the study period, hemodynamic and clinical results before admission, at 30 days, and at 1 year of follow-up were compared between the two generations. RESULTS: A total of 296 patients underwent transcatheter aortic valve implantation with the ACURATE device, with 178 patients receiving the ACURATE neo and 118 patients receiving the ACURATE neo2. In the overall population, the absence of device success occurred in 14.5%. The primary reason for the absence of device success was the presence of para-valvular regurgitation ≥ 2. There were no instances of coronary occlusions, valve embolization, annulus rupture, or procedural deaths. ACURATE neo2 was associated with a significantly higher device success rate (91.7% vs. 82%, p = 0.04), primarily due to a significantly lower rate of para-valvular regurgitation, which remained significant at 1 year. CONCLUSION: The use of ACURATE neo and neo2 transcatheter aortic valves is associated with satisfactory clinical results and an extremely low rate of complications. The ACURATE neo2 enables a significantly higher device success rate, primarily attributed to a significant reduction in the rate of PVL.


Assuntos
Estenose da Valva Aórtica , Valva Aórtica , Próteses Valvulares Cardíacas , Hemodinâmica , Desenho de Prótese , Sistema de Registros , Substituição da Valva Aórtica Transcateter , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Valva Aórtica/cirurgia , Valva Aórtica/fisiopatologia , Valva Aórtica/diagnóstico por imagem , Insuficiência da Valva Aórtica/fisiopatologia , Insuficiência da Valva Aórtica/etiologia , Insuficiência da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/fisiopatologia , Estenose da Valva Aórtica/diagnóstico por imagem , Complicações Pós-Operatórias , Estudos Prospectivos , Recuperação de Função Fisiológica , Fatores de Risco , Espanha , Fatores de Tempo , Substituição da Valva Aórtica Transcateter/instrumentação , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento
4.
J Invasive Cardiol ; 2024 Mar 22.
Artigo em Inglês | MEDLINE | ID: mdl-38517884

RESUMO

Dynamic road-mapping (DRM) (Dynamic Coronary Roadmap; Philips) offers a real-time, dynamic overlay of the coronary tree on fluoroscopy.

5.
J Endovasc Ther ; : 15266028241233994, 2024 Feb 22.
Artigo em Inglês | MEDLINE | ID: mdl-38385241

RESUMO

CLINICAL IMPACT: Mechanical thrombectomy using a thromboaspiration catheter can be an effective alternative in the treatment of subacute pulmonary embolism.

6.
Catheter Cardiovasc Interv ; 103(3): 482-489, 2024 02.
Artigo em Inglês | MEDLINE | ID: mdl-38204382

RESUMO

OBJECTIVES: The aim of this study was to analyze the efficacy and safety of percutaneous balloon pericardiotomy (PBP) in oncological patients who present with a malignant pericardial effusion (MPE). BACKGROUND: The use of PBP as a treatment for MPE is not standardized due to the limited evidence. Furthermore, the performance of a second PBP for a recurrence after a first procedure is controversial. METHODS: The BALTO Registry (BALloon pericardioTomy in Oncological patients) is a prospective, single-center, observational registry that includes consecutive PBP performed for MPE from October 2007 to February 2022. Clinical and procedural, characteristics, as well as clinical outcome were analyzed. RESULTS: Seventy-six PBP were performed in 61 patients (65% female). Mean age was of 66.4 ± 11.2 years. In 15 cases, a second PBP procedure was performed due to recurrence despite the first PBP. The procedure could be performed effectively in all cases with only two serious complications. Ninety-five percent of cases were discharged alive from the hospital. During a median follow-up of 6.3 months (interquartile range [IQR], 0.9-10.8), MPE recurred in 24.5% cases although no recurrences were reported after the second procedure. No evidence of malignant pleural effusion developed on follow-up. The median overall survival time was 5.8 months (IQR, 0.8-10.2) and the time to recurrence after the first PBP was 2.4 months (IQR, 0.7-4.5). CONCLUSIONS: PBP is a safe and effective treatment for MPE. It could be considered an acceptable therapy in most MPE, even in those who recur after a first procedure.


Assuntos
Oclusão com Balão , Derrame Pericárdico , Humanos , Feminino , Pessoa de Meia-Idade , Idoso , Masculino , Pericardiectomia/efeitos adversos , Resultado do Tratamento , Estudos Prospectivos , Derrame Pericárdico/diagnóstico por imagem , Derrame Pericárdico/etiologia , Derrame Pericárdico/terapia , Oclusão com Balão/efeitos adversos
7.
Microvasc Res ; 150: 104598, 2023 11.
Artigo em Inglês | MEDLINE | ID: mdl-37633337

RESUMO

In the 20th century, research focused on cholesterol and lipoproteins as the key mechanism in establishing atherosclerotic cardiovascular disease (ASCVD). Given that some studies demonstrated subclinical atherosclerosis in subjects without conventional cardiovascular risk factors, the elevated low-density lipoprotein (LDL) levels alone cannot account for the entire burden of atherosclerosis. Hence, large-scale clinical trials demonstrated the operation of immune and inflammatory pathways in ASCVD. In this regard, the evidence establishes that cells of the immune system, both the innate (neutrophils, macrophages) and adaptive (T cell and other lymphocytes) limbs, contribute to atherosclerosis and atherothrombosis. Besides, basic science studies have identified proatherogenic cytokines such as interleukin (IL)-1, IL-12, and IL-18. In this regard, some studies showed that antiinflammatory therapy targeting the immune system by modulating or blocking interleukins, also known as anti-cytokine therapy, can reduce the risk of major cardiovascular adverse events. The neutrophils play a key role in the innate immune system, representing the acute phase of an inflammatory response. In contrast, lymphocytes represent the adaptive immune system and promote the induction of autoimmune inflammation, especially in the chronic inflammatory response. Through the literature review, we will highlight the inflammatory pathway for the physiopathology of ASCVD, HF, and COVID-19. In this regard, the neutrophil-to-lymphocyte ratio (NLR) integrates the innate immune and adaptive immune systems, making the NLR a biomarker of inflammation. In addition, we provided an update on the evidence showing that high NLR is associated with worse prognosis in heart failure (HF), ASCVD, and COVID-19, as well as their clinical applications showing that the normalization of NLR after anti-cytokine therapy is a potential predictor of therapy responsiveness and is associated with reduction of major adverse cardiovascular events.


Assuntos
Aterosclerose , COVID-19 , Doenças Cardiovasculares , Insuficiência Cardíaca , Humanos , Doenças Cardiovasculares/diagnóstico , Neutrófilos , Prognóstico , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/tratamento farmacológico , Linfócitos , Biomarcadores , Doença Crônica
8.
J Invasive Cardiol ; 35(4): E223-E224, 2023 04.
Artigo em Inglês | MEDLINE | ID: mdl-37029998

RESUMO

Cardiac computed tomography (CT) scan was performed in a 69-year-old male with atrial fibrillation radiofrequency ablation who was admitted for transcatheter angioplasty of left inferior pulmonary vein (LIPV) stenosis due to recurrent hemoptysis. CT showed complete ostial occlusion in the area of the LIPV. Occlusion of the pulmonary vein ostium is a rare complication. We describe the successful use of chronic occlusion techniques in the treatment of this patient.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Doenças Vasculares , Masculino , Humanos , Idoso , Veias Pulmonares/diagnóstico por imagem , Veias Pulmonares/cirurgia , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Fibrilação Atrial/complicações , Angioplastia/efeitos adversos , Doenças Vasculares/cirurgia , Constrição Patológica/diagnóstico , Constrição Patológica/etiologia , Constrição Patológica/cirurgia , Ablação por Cateter/efeitos adversos
10.
J Invasive Cardiol ; 35(2): E103-E105, 2023 02.
Artigo em Inglês | MEDLINE | ID: mdl-36735872

RESUMO

To the best of our knowledge, this case represents the first patient with Mitraclip, Amplatzer, and TricValve devices with a profound clinical improvement and long-term follow-up. In addition, this case illustrates how the treatment of high-risk patients with polyvalvular disease has changed in the last few years.


Assuntos
Implante de Prótese de Valva Cardíaca , Insuficiência da Valva Mitral , Humanos , Valva Mitral/diagnóstico por imagem , Valva Mitral/cirurgia , Insuficiência da Valva Mitral/diagnóstico , Insuficiência da Valva Mitral/cirurgia , Insuficiência da Valva Mitral/etiologia , Cateterismo Cardíaco/efeitos adversos , Implante de Prótese de Valva Cardíaca/efeitos adversos , Resultado do Tratamento
11.
J Invasive Cardiol ; 35(2): E110-E111, 2023 02.
Artigo em Inglês | MEDLINE | ID: mdl-36735875

RESUMO

An 86-year-old patient with non-valvular atrial fibrillation was referred to our institution to undergo a left atrial appendage (LAA) closure for recurrent gastrointestinal bleeding on direct oral anticoagulants. The transesophageal echocardiogram (TEE) performed the previous day evaluated the morphology and dimensions of the LAA and ruled out any thrombus. During the procedure, a pigtail catheter was inserted into the LAA, observing an unusual image we describe as a culde- sac, without an anomalous connection with any drainage in other vessel or cavity. After additional imaging studies, we concluded that it was morphology related to LAA, which we have termed the "water-gun" morphology. Four morphologies have been described based on the shape of the central and secondary lobes. To the best of our knowledge, this is the first description of a fifth type, which was shown to be effectively closed with current closure devices.


Assuntos
Apêndice Atrial , Fibrilação Atrial , Procedimentos Cirúrgicos Cardíacos , Trombose , Humanos , Idoso de 80 Anos ou mais , Apêndice Atrial/diagnóstico por imagem , Apêndice Atrial/cirurgia , Fibrilação Atrial/complicações , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Ecocardiografia Transesofagiana , Resultado do Tratamento
13.
Catheter Cardiovasc Interv ; 101(3): 651-654, 2023 02.
Artigo em Inglês | MEDLINE | ID: mdl-36691874

RESUMO

Coronary fistulas are not common in patients undergo coronary angiography. It is described, even less frequently, that coronary fistulas may be associated with giant aneurysms along their course. These cases classically are treated surgically. We present a case treated fully percutaneously in a novel fashion.


Assuntos
Aneurisma Coronário , Seio Coronário , Fístula , Humanos , Aneurisma Coronário/complicações , Aneurisma Coronário/diagnóstico por imagem , Aneurisma Coronário/terapia , Resultado do Tratamento , Angiografia Coronária , Fístula/complicações
14.
Minerva Cardiol Angiol ; 71(3): 284-293, 2023 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-35420282

RESUMO

BACKGROUND: It is unknown whether the availability of long drug-eluting stents modify the PCI strategy of long CTO. To describe the contemporary PCI strategy of long chronic total occlusions (CTO) using overlapping (OS) or single long stents (SS) and to analyze its results. METHODS: 2842 consecutive CTO PCIs were included. Those with an occlusion length ≥20 mm in which ≥1 drug eluting stent (DES) was implanted were analyzed. We compared procedural characteristics and clinical outcomes of CTO treated with OS or SS. RESULTS: 1088 CTO PCIs were analyzed (79.9% males; 64.7±10.6 years). Mean J-score was 2.8±0.9. A SS was used in 38.5% of cases and OS in 61.5%. Total stent length was 64.1±29.9 mm; it was higher in the OS group (OS: 79.9±25.5 mm vs. SS: 38.3±14.7 mm; P<0.0001). Mean number of stents in the OS group was 2.3±1. Very long stents (≥40 mm) were used in 27.4% of cases, more frequently in the OS group (OS:32.4% vs. SS:19.3%; P<0.0001). After a mean follow-up of 19±15.9 months, the rate of adverse events (MACE) was 2% (cardiac death: 1.6%, myocardial infarction: 1.6%, target lesion revascularization: 1.9% and stent thrombosis: 0.18%) with no significant differences between both groups. Overlapping was not an independent predictor of MACE. CONCLUSIONS: In long CTO PCIs, OS is more frequently used than single stenting, especially in more complex procedures. Clinical outcomes at a mid-term follow-up are favorable. Using newer generation DES, overlapping was not an independent predictor of MACE; however, a trend toward a higher event rate was observed in the OS group.


Assuntos
Oclusão Coronária , Stents Farmacológicos , Intervenção Coronária Percutânea , Masculino , Humanos , Feminino , Oclusão Coronária/cirurgia , Oclusão Coronária/etiologia , Stents Farmacológicos/efeitos adversos , Intervenção Coronária Percutânea/efeitos adversos , Resultado do Tratamento , Doença Crônica , Stents , Sistema de Registros
16.
Catheter Cardiovasc Interv ; 100(7): 1286-1290, 2022 12.
Artigo em Inglês | MEDLINE | ID: mdl-36273418

RESUMO

OBJECTIVES: The aim of this study was to describe the procedural and early outcomes of patients with mechanical mitral valve prosthesis (MVP) undergoing transcatheter aortic valve replacement (TAVR) with a novel self-expandable retrievable device. BACKGROUND: TAVR in patients with prior MVP may have an increased risk of complications related to device positioning and interference between both prosthetic valves. METHODS: An observational study was conducted, including eight patients with severe symptomatic aortic stenosis and prior mechanical MVP who underwent TAVR with the novel device AllegraTM (Biosensors). No transesophageal monitoring was used. RESULTS: The mean age of the study population was 75 years. The mean distance between MVP and aortic annulus was 3.8 mm. Procedural success was achieved in all patients with no major intraprocedural, in-hospital, or follow-up complications. CONCLUSIONS: TAVR with Allegra TAVI system in patients with prior MVP offers good procedural and clinical outcomes.


Assuntos
Estenose da Valva Aórtica , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Humanos , Idoso , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/complicações , Valva Mitral/diagnóstico por imagem , Valva Mitral/cirurgia , Desenho de Prótese , Complicações Pós-Operatórias/etiologia , Resultado do Tratamento , Próteses Valvulares Cardíacas/efeitos adversos , Substituição da Valva Aórtica Transcateter/efeitos adversos
18.
Int J Surg Case Rep ; 99: 107659, 2022 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-36116308

RESUMO

INTRODUCTION AND IMPORTANCE: Various artifacts mimicked aortic dissection, such as streak artifacts generated by high-attenuation material, high-contrast interfaces, cardiac motion, periaortic structures, aortic wall motion, and normal aortic sinuses, have been described in the literature. Most artifacts that simulate ascending aortic dissection occur frequently on conventional CT. Their position is predictable and is related to systolic aortic motion. However, so far, to the best of our knowledge, this is the first pseudo-aortic dissection reported during coronary angiography in cardiac arrest. CASE PRESENTATION: We report a case of a middle-aged man transferred to our hospital after an out-of-hospital cardiac arrest. The coronary angiography revealed non-obstructive coronary arteries and an image of probable aortic dissection was observed. Given the persistent asystole despite a prolonged advance cardiopulmonary resuscitation and the possibility of aortic dissection, a prompt in-room heart team discussion was performed. It was decided to stop and withdraw potentially life-sustaining treatment due to futility. The necropsy study revealed the aorta with some mild atherosclerotic plaques but without either aneurysm or thrombosis. The coronary arteries were reported as with patency, but in the proximal left anterior descending artery (LAD), the intima layer presented a thickness that decreased 50 % of the luminal area without signs of complicated acute plaques. CLINICAL DISCUSSION: In this case, the systolic aortic motion theory cannot explain the false-aortic dissection image in the coronary angiography because the patient was under cardiac arrest. Studies with arterial and venous pressures devices recording in cardiac arrest, demonstrated an abnormal hemodynamic flow, suggesting that the hemodynamic flow might be backward during cardiopulmonary resuscitation Therefore, in the setting of this abnormal hemodynamic flow, the injection of contrast may have an abnormal distribution and flow in the aorta creating an image of pseudo-aortic dissection. CONCLUSION: Although the exact mechanism of this false-positive aortic dissection in cardiac arrest remains unknown, operators should be aware of this entity during coronary angiography in the setting of cardiac arrest with mechanical chest compressions to avoid diagnostic errors in clinical practice.

19.
Ann Noninvasive Electrocardiol ; 27(6): e12998, 2022 11.
Artigo em Inglês | MEDLINE | ID: mdl-35904538

RESUMO

BACKGROUND: Since the last century, the electrocardiogram (ECG) remains the non-invasive test, that is, most easily accessible, feasible, and inexpensive for cardiology assessment. In past years, many novel ECG indexes and patterns have been published that allow for a more advanced evaluation of what is currently being done, especially based on subtle QRS changes and patterns. OBJECTIVE: The objective of the study was to provide an update on the evidence and clinical applications of these ECG subtle QRS changes and patterns associated with heart disease. METHODS: Through the literature review, we will highlight the subtle QRS changes and patterns associated with heart disease, mainly focusing on QRS duration, voltage, morphology, axis, and QT interval. RESULTS: Small increases in QRS duration are associated with a reduction in left ventricular ejection fraction (EF), increased cardiac chamber dimensions, and risk for incident heart failure (HF). Moreover, fragmentation of the QRS complex is associated with myocardial fibrosis and is a substrate for developing arrhythmic events. Besides, low amplitude QRS voltage is associated with congestive HF, and an increase in the voltage of the QRS complexes is associated with the effectiveness of diuresis treatment. Furthermore, small increases in QT interval are associated with diastolic dysfunction due to impaired sarcoplasmic reticulum calcium handling as occurs in myocardial ischemia, hypertension, or diabetes. On the other hand, in patients with left ventricular dysfunction, the QRS area is associated with clinical and echocardiographic response to cardiac resynchronization therapy regardless of the type of bundle branch block. In addition, subtle ECG changes and patterns in the left bundle branch block are associated with concomitant right ventricular dilation, mostly based on the QRS axis and voltage. Notwithstanding, to identify these subtle changes in QRS require exact manual measurements that can take time. In this regard, applying artificial intelligence (AI) to the ECG can make a quicker and more complete assessment, as well as provide a low cost when applied to large populations. CONCLUSION: We provided an update on the evidence and clinical applications of these subtle QRS changes and patterns associated with diastolic dysfunction, reduced EF, and HF development and therapy responsiveness, as well as their applications for AI to ECG.


Assuntos
Insuficiência Cardíaca , Disfunção Ventricular Esquerda , Humanos , Volume Sistólico/fisiologia , Eletrocardiografia/métodos , Função Ventricular Esquerda/fisiologia , Inteligência Artificial , Insuficiência Cardíaca/complicações , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/terapia , Bloqueio de Ramo , Disfunção Ventricular Esquerda/complicações , Disfunção Ventricular Esquerda/diagnóstico , Disfunção Ventricular Esquerda/terapia , Arritmias Cardíacas
20.
Int J Cardiol ; 362: 128-136, 2022 09 01.
Artigo em Inglês | MEDLINE | ID: mdl-35550389

RESUMO

BACKGROUND: High degree cardiac conduction disturbances (HDCD) remain a major complication after transcatheter aortic valve replacement (TAVR), especially with self-expandable valves (SEV). Our aim was to investigate peri-procedural and in-hospital modification of atrioventricular and intracardiac conduction associated to new generation SEV implantation, and the development of new HDCD resulting in permanent pacemaker implantation (PPM) in patients undergoing TAVR. METHODS AND RESULTS: Three-hundred forty-four consecutive patients with severe aortic stenosis who underwent TAVR with a new generation SEV [Evolut-R/Pro (n = 130), Acurate-neo (n = 79), Portico (n = 75) and Allegra (n = 60)] were included. An analysis of baseline, post-TAVR and pre-discharge ECG and procedural aspects were centrally performed. A significant increase in baseline PR interval (169.6 ± 28.2 ms) and QRS complex width (101.7 ± 25.9 ms) was noted immediately post-TAVR (188.04 ± 34.49; 129.55 ± 30.02 ms), with a partial in-hospital reversal (179.4 ± 30.1; 123.06 ± 30.94 ms), resulting in a net increase at hospital discharge of 12.6 ± 38.8 ms and 21.4 ± 31.6 ms (p < 0.001), respectively. The global incidence of new onset persistent HDCD at hospital discharge was 46.3%, with 17.7% of patients requiring PPM. Independent predictors of new onset HCDC at hospital discharge were valve recapture (OR: 2.8; 95% IC: 1.1-7.2, p = 0.033) and implantation depth ≥ 6 mm (OR: 1.9 05% IC 1.1-3.3, p = 0.015), while higher implantation (<3 mm (OR: 0.3, 95% IC 0.1-0.7, p = 0.014) and use of Acurate-Neo valve (OR: 0.4; 95% IC 0.2-0.8, p = 0.009) were protective factor. CONCLUSIONS: New generation self-expanding aortic valves were associated with a significant increase in PR and QRS interval at hospital discharge leading to a very high rate of HDCD. While valve recapture and implantation depth were independent predictors for the occurrence of HDCD, use of Accurate-Neo valve was a protective factor.


Assuntos
Substituição da Valva Aórtica Transcateter , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/cirurgia , Doença do Sistema de Condução Cardíaco/diagnóstico , Doença do Sistema de Condução Cardíaco/epidemiologia , Próteses Valvulares Cardíacas/efeitos adversos , Humanos , Desenho de Prótese , Fatores de Risco , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA