Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
1.
Pediatr Res ; 91(7): 1754-1761, 2022 06.
Artigo em Inglês | MEDLINE | ID: mdl-34285352

RESUMO

BACKGROUND: Endothelial microparticles (EMPs) act as early biomarkers of endothelial activation and damage. No studies have investigated EMPs in preterm-born individuals. METHODS: Sixty-three preterm-born children and 52 children born full-term (controls) were studied. Circulating CD62E(+), CD144(+), and CD31(+)/CD42b(-) EMPs were measured in preterm-born children compared to controls; possible associations with cardiovascular risk factors and endothelial function parameters were also assessed. RESULTS: Circulating CD62E(+), CD144(+), and CD31(+)/CD42b(-) EMPs were significantly higher in preterm-born children compared to controls (p = 0.003, p < 0.001, and p < 0.001, respectively). Preterm birth was recognized as an independent predictor of each EMP subpopulation studied; moreover, the mean pressure and velocity of pulmonary artery were independently correlated with CD62E(+) (ß = 0.20, p = 0.04) and CD144(+) EMPs (ß = 0.22, p = 0.02), respectively, whereas age (ß = 0.21, p = 0.03) and being born SGA (ß = 0.26, p = 0.01) correlated independently with CD31(+)/CD42b(-) EMPs in the study population. Furthermore, diastolic blood pressure (ß = 0.24, p = 0.04), being born SGA (ß = 0.24, p = 0.04) and the hyperemic peak velocity of the brachial artery (ß = -0.65, p = 0.02) were independently associated with CD31(+)/CD42b(-) EMPs in the preterm-born group. CONCLUSION: Circulating EMPs were higher in preterm-born children compared to children born full-term. Whether EMPs could act, in clinical practice, as a complementary tool for non-invasive evaluation of endothelium in preterm-born children, remains under investigation. IMPACT: Circulating endothelial microparticles (EMPs) are small membrane vesicles released from endothelial cells and they act as novel biomarkers of endothelial activation and damage. No studies have investigated circulating EMPs in preterm-born individuals. Circulating EMPs were significantly higher in prepubertal preterm-born children compared to children born at term. In the preterm-born group, the hyperemic peak velocity of the brachial artery was independently associated with CD31(+)/CD42b(-) EMPs. Whether assessment of circulating EMPs could act, in clinical practice, as a complementary tool for non-invasive evaluation of endothelium in preterm-born children, remains to be defined in future investigations.


Assuntos
Micropartículas Derivadas de Células , Nascimento Prematuro , Biomarcadores , Criança , Células Endoteliais/fisiologia , Endotélio Vascular , Feminino , Humanos , Recém-Nascido
2.
Pediatr Radiol ; 51(8): 1358-1368, 2021 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-33755748

RESUMO

BACKGROUND: Although fibrosis is the main determinant of liver stiffness, other disease-related factors usually disregarded in studies on liver elastography, such as inflammation and cholestasis, may influence liver stiffness. OBJECTIVE: To evaluate the accuracy of two-dimensional (2-D) shear wave elastography in assessing liver fibrosis in children with chronic liver disease by controlling for the confounding role of several disease- and patient-related factors. MATERIALS AND METHODS: Three disease groups were studied: 1) various chronic liver diseases, 2) autoimmune hepatitis and 3) biliary atresia. The METAVIR (meta-analysis of histological data in viral hepatitis) score was used for fibrosis staging and grading of necroinflammatory activity. Multiple linear regression was used to evaluate the relationship between liver stiffness measurements and disease-related factors. The diagnostic accuracy of elastography for predicting fibrosis stages was assessed by calculating the area under the receiver operating characteristic curves. RESULTS: The various chronic liver diseases group (n=32; 7.1±4.9 [mean±standard deviation] years) showed liver stiffness of 8.9±5.0 (mean±standard deviation) kPa, the autoimmune hepatitis group (n=33; 8.1±4.4 years) of 7.1±2.7 kPa, and the biliary atresia group (n=19; 0.2±0.1 years) of 19.7±15.2 kPa. Liver stiffness measurements differed across METAVIR fibrosis categories in all disease groups. The highest values were found in biliary atresia, at fibrosis stages ≥F2 (F2: 12.4±1.6 kPa, F3: 17.8±2 kPa, F4: 41.5±12.4 kPa). Liver stiffness was strongly associated only with fibrosis (P<0.0001) in various chronic liver diseases, but with necroinflammatory activity (P<0.0001) and fibrosis (P=0.002) in autoimmune hepatitis, and with age (P<0.0001), fibrosis (P<0.0001) and cholestasis (P=0.009) in biliary atresia. Optimal cutoffs for detecting advanced fibrosis (≥F3) were 16 kPa (area under curve: 0.98; sensitivity: 87.5%; specificity: 96.7%) in biliary atresia and 8.7 kPa (area under curve: 0.98; sensitivity: 93.8%; specificity: 96.1%) in other chronic liver diseases. CONCLUSION: Two-dimensional shear wave elastography is reliable in assessing liver fibrosis in children with chronic liver diseases.


Assuntos
Atresia Biliar , Técnicas de Imagem por Elasticidade , Hepatite Autoimune , Hepatopatias , Atresia Biliar/complicações , Atresia Biliar/diagnóstico por imagem , Criança , Hepatite Autoimune/complicações , Hepatite Autoimune/diagnóstico por imagem , Humanos , Fígado/diagnóstico por imagem , Fígado/patologia , Cirrose Hepática/diagnóstico por imagem , Cirrose Hepática/patologia , Hepatopatias/diagnóstico por imagem , Hepatopatias/patologia
3.
Pediatr Res ; 90(1): 156-165, 2021 07.
Artigo em Inglês | MEDLINE | ID: mdl-33038874

RESUMO

BACKGROUND: Endothelial progenitor cells (EPCs) ensure vascular integrity and neovascularization. No studies have investigated EPCs in preterm-born children beyond infancy. METHODS: One hundred and thirty-six prepubertal children were enrolled: 63 preterm and 73 born at term (controls). Circulating CD34(+)/VEGFR-2(+)/CD45(-) and CD34(+)/VEGFR-2(+)/CD45dim EPCs were measured in preterm-born children compared to controls. Body mass index (BMI), waist-to-hip ratio (WHR), neck circumference, systolic and diastolic blood pressure (SBP and DBP, respectively), fasting glucose, insulin, lipid profile, common carotid and abdominal aortic intima-media thickness (cIMT and aIMT, respectively), endothelium-dependent brachial artery flow-mediated dilation (FMD), and echocardiographic parameters were also assessed. RESULTS: Circulating CD34(+)/VEGFR-2(+)/CD45(-) and CD34(+)/VEGFR-2(+)/CD45dim EPCs were significantly higher in preterm-born children compared to controls (p < 0.001 and p < 0.001, respectively). In total study population and in the preterm-born group, EPCs were significantly lower in children born to mothers with gestational diabetes compared to non-diabetic mothers. Prematurity was associated with higher WHR, neck circumference, SBP, DBP, cIMT, aIMT, mean pressure, and velocity of pulmonary artery; the peak velocity of the brachial artery was significantly lower in children born prematurely. In multiple regression analysis, preterm birth and maternal gestational diabetes were recognized as independent predictors of EPCs. CONCLUSIONS: Circulating EPCs were increased in prepubertal preterm-born children in comparison with peers born full-term. Maternal gestational diabetes was associated with a decrease in EPCs. IMPACT: Mounting evidence supports the adverse effect of prematurity on cardiovascular health. However, the underlying mechanisms that could lead to endothelial dysfunction in preterm-born individuals are not fully understood. Endothelial progenitor cells (EPCs) ensure vascular integrity, normal endothelial function and neovascularization. No studies have investigated the EPCs counts in peripheral blood beyond infancy in children born prematurely. Circulating EPCs were significantly higher in preterm-born prepubertal children compared to controls, thus indicating that prematurity is possibly associated with endothelial damage. In total study population and in the preterm-born group, maternal gestational diabetes was associated with decreased EPCs concentrations.


Assuntos
Células Progenitoras Endoteliais/citologia , Fatores de Risco de Doenças Cardíacas , Nascimento Prematuro/fisiopatologia , Antígenos CD34/sangue , Artéria Braquial/fisiopatologia , Artérias Carótidas/fisiopatologia , Estudos de Casos e Controles , Criança , Células Progenitoras Endoteliais/imunologia , Feminino , Humanos , Antígenos Comuns de Leucócito/sangue , Masculino , Receptor 2 de Fatores de Crescimento do Endotélio Vascular/sangue , Relação Cintura-Quadril
4.
Pediatr Radiol ; 49(1): 91-98, 2019 01.
Artigo em Inglês | MEDLINE | ID: mdl-30267166

RESUMO

BACKGROUND: Two-dimensional (2-D) shear wave elastography is a new sonographic elastography method for noninvasive measurement of liver stiffness. OBJECTIVE: The aim of this study was to establish reference values of normal liver stiffness on 2-D shear wave elastography in children. MATERIALS AND METHODS: Two-dimensional shear wave elastography values were measured in 202 children with no liver disease from the neonatal period to puberty, who were divided into 4 age groups: newborns and infants, preschoolers, elementary school children and adolescents. We investigated the effects of age, depth of elastography measurement, transducer, number of measurements per child, liver size and Doppler parameters of hepatic blood flow on liver elasticity values. RESULTS: The mean normal liver elasticity value in the study population was: 4.29±0.59  kilopascals (kPa). In neonates and infants, mean liver elasticity value was 4.63 (± 0.6) kPa, in preschoolers and elementary school children, 4.05 (± 0.57) kPa and 4.15 (± 0.52) kPa, respectively, and in adolescents, 4.39 (± 0.55) kPa. Values in neonates and infants as well as adolescents were significantly higher than in preschoolers and elementary school children (Kruskal-Wallis, P<0.001; Mann-Whitney U tests, P<0.05). There was no significant association between liver elasticity values and size of the right lobe or Doppler parameters of hepatic blood flow. Different depths and the number of elastography measurements had no effect on liver elasticity values. CONCLUSION: Two-dimensional shear wave elastography is achievable in a wide range of age in children. We established the reference values of normal liver stiffness on 2-D shear wave elastography in children.


Assuntos
Técnicas de Imagem por Elasticidade/métodos , Fígado/diagnóstico por imagem , Adolescente , Criança , Pré-Escolar , Módulo de Elasticidade/fisiologia , Feminino , Humanos , Lactente , Recém-Nascido , Masculino , Valores de Referência
5.
Pediatr Radiol ; 45(11): 1661-71, 2015 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-26104655

RESUMO

BACKGROUND: Little attention has been given to the sonographic appearances of the epididymis in testicular torsion. OBJECTIVE: To describe the position and morphology of the epididymis in childhood acute testicular torsion when testicular flow is present on color Doppler sonography. MATERIALS AND METHODS: We studied the sonographic findings in boys with clinically and surgically proven acute testicular torsion who were examined sonographically from May 2013 to May 2014 and who had preserved intratesticular flow on color Doppler sonography. We retrospectively evaluated the sonograms with emphasis on the epididymal findings. RESULTS: In all nine boys with confirmed torsion but with preserved intratesticular flow on color Doppler sonography, the epididymal head had an unexpected configuration and size, and no close relationship with the upper pole of the testis. In five of these children the spermatic cord appeared twisted on the affected side. In the remaining four boys the spermatic cord appeared straight. CONCLUSION: The position and morphology of the head of the epididymis were abnormal in all boys with acute testicular torsion but with preserved testicular flow.


Assuntos
Epididimo/diagnóstico por imagem , Torção do Cordão Espermático/complicações , Torção do Cordão Espermático/diagnóstico por imagem , Testículo/diagnóstico por imagem , Ultrassonografia Doppler em Cores/métodos , Adolescente , Velocidade do Fluxo Sanguíneo , Criança , Epididimo/fisiopatologia , Humanos , Masculino , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Torção do Cordão Espermático/fisiopatologia , Testículo/irrigação sanguínea , Testículo/fisiopatologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA